The Agilent 5975 inert MSD: New Tools for the Forensic Analyst

Similar documents
5975 inert MSD. Chris Sandy European GC-MS Product Specialist Agilent Technologies

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

New Features of Deconvolution Reporting Software Revision A.02 Technical Note

Fatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

Agilent GC/MSD Instructions

GC-MS ChemStation Reference Guide. Last Updated July 2014

5973 Network Mass Selective Detectors

Retention Time Locking Operation

Agilent 5977 MSD Overview

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

Getting Started. Environmental Analysis Software

Agilent G1732AA MSD Security ChemStation

Agilent G1701DA MSD ChemStation

Samples Preparing the GC to run samples Running samples - Manual Injection Running samples - GC ALS or Valve Injection

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

Agilent 5977 Series MSD System

Steps for LCMS-8040 Triple Quadrupole

Agilent G2070BA GC ChemStation

Agilent MassHunter GCMS Data Acquisition for the 5977 Series MSD System

Agilent 6400 Series Triple Quadrupole LC/MS System

Agilent Intuvo 9000 Gas Chromatograph

Agilent 6100 Series Quad LC/MS System

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

UPDATING PESTICIDE RETENTION TIME LIBRARIES FOR THE AGILENT INTUVO 9000 GC

Agilent SP in-1 GC/MSD DRS Analyzer

SIM Direct Inlet Probe. Agilent 5975 MSD. Agilent 7000 Triple Quadrupole

Agilent G6855AA MassHunter Personal

True Blue Performance

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Agilent G1732AA MSD Security ChemStation

Agilent 7890 Series Gas Chromatograph

Agilent G1701DA GC/MSD ChemStation

Application Note. Abstract. Authors. Forensic Toxicology

Toxicology Gas Chromatography-Mass Spectrometry (GC-MS)

Agilent G1732BA MSD Security ChemStation

Agilent G1701DA GC/MSD ChemStation

Agilent MassHunter Qualitative Data Analysis

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

Agilent GC, MS, and ALS

How to Run the CASPiE GCMS

Customers should provide all necessary operating supplies upon request of the engineer.

Thermo Xcalibur Getting Started (Quantitative Analysis)

Quick Guide to the Star Bar

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

TraceFinder Analysis Quick Reference Guide

5973N and 5973 inert Mass Selective Detector

Chromeleon software orientation

SIMAT: GC-SIM-MS Analayis Tool

Introduction to Time-of-Flight Mass

Agilent Instrument Control Framework for Agilent LC/CE and GC instruments in Non-Agilent Chromatography Data Systems A.02.

Xcalibur Library Browser

Agilent MassHunter Easy Access Software

Partner; Democritus University of Thrace (UTHR.DEE.APL) Workpackage; WP 4 and WP 1

Isolera. User Manual

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

Agilent 7820A Gas Chromatograph

Agilent G2727AA LC/MS Data Browser Quick Start

Bio Compatibility Kit

Agilent 7890B Gas Chromatograph

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Supporting Information

Chromatography Software Training Materials. Contents

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

OpenLynx User's Guide

Manual HPLC-4 Alliance-UV

Agilent 1290 Infinity 2D-LC Solution

Release Note for Agilent LC and CE Drivers Revision A.02.15

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Quick Reference. 5973N and 5973 inert Mass Selective Detector Local Control Panel (LCP)

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

Andreas Reimann Berlin im Juli 2009

Sniffer 9100 Series. GC-O GC/MS-O, State of the art... GC-Olfactometry Method for Food, Flavor and Fragrances. Principle

REVIEW. MassFinder 3. Navigation of the Chromatogram

Automated Fraction Re-Analysis Does it really make sense?

Agilent Splitter Kits

Release Note for Agilent LC and CE Drivers Revision A.02.16

Agilent GC Drivers A

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Agilent G1978B Multimode Source for 6100 Series Single Quad LC/MS

NOTICE: This document contains references to Varian. Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to

MassHunter Pesticides PCD or PCDL Quick Start Guide

Chemical Analysis Group Gas Chromatograph Common Cabling \ Pin-outs Document A15707

SPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Introduction to the HPLC ChemStation and Acquisition

Release Note for Agilent LC and CE Drivers Revision A.02.17

Installing and Understanding Your GC-AED ChemStation. Agilent GC-AED ChemStation

Release Note for Agilent LC and CE drivers Revision A.02.14

Hardware Guide. AB SCIEX QTRAP 5500 System

Update on Data Acquisition Software Improvements Since Last Year. Additional Critical Orifices

Soprane II Documentation

Cat. # Lot #'s A & A058670

Tutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa

Agilent 6300 Ion Trap LC/MS Systems Quick Start Guide

Transcription:

The Agilent 5975 inert MSD: New Tools for the Forensic Analyst Chemical Analysis Group Bruce D. Quimby, Ph.D. Senior Applications Chemist Agilent Technologies Wilmington, Delaware March 2,2006 Page 1

The Speaker Dr. Bruce Quimby is a Senior Applications Chemist in the Chemical Analysis Solutions unit of Agilent Technologies in Wilmington, Delaware. He received a Ph.D. in analytical chemistry from the University of Massachusetts (Amherst) in 1980 and a batchelors degree in chemistry from Mansfield State College (PA) in 1974. He has been at Agilent Technologies (formerly Hewlett-Packard) since 1979, working the first 10 years in research and development. He has authored or co-authored 18 journal articles and 10 patents in the field of gas chromatography. He is currently working in Forensic and Homeland Security applications. R&D ID Photo Marketing ID Photo Page 2

Introducing the 5975 inert MSD Page 3

What s Different? Does everything a 5973 does, plus Synchronous SIM/Scan Extended mass range AutoCI and EI with CI source 6850 GC control QuickSwap MSD interface Permanent Effluent Splitters Deconvolution Reporting Software Page 4

Functional Front Window Ease of Use Wire connections Filament operation Column insertion CI Source identification Page 5

Quick Access Ease of Use Easy analyzer access hinged side cover Page 6

Extended Mass Range Performance 1050 m/z for 5975 inert MSD Quadrupole modified New electronics 800 m/z for all 5973 MSDs (Software upgrade does not enable 1050 m/z) Page 7

AutoCI Performance No external manual control Fully automated setup/tuning Flexible Configuration EI capability with CI Source AutoCI as easy as EI Page 8

AutoCI Electronic Flow Control Ease of Use Reagent gas automatically adjusted by tune Ammonia compatibility Ensures easy reproduction of application A B Electronic Flow Transferline Gas A & B PFDTD Page 9

Ion Source Improved Response Data from a production forensic drug lab Inert Ion source Improved response 50pg LSD SS Source Inert Source Extracted Ion 253 m/z ~6x improvement! LSD S/N 2.9 LSD S/N 16 6.10 6.20 6.30 6.40 6.50 6.60 6.70 6.80 6.90 7 6.10 6.20 6.30 6.40 6.50 6.60 6.70 6.80 6.90 7.00 7.10 7.20 7.30 7.40 7.50 Page 10

Faster Scan Speeds and 5 msec SIM Dwell Standard Electronics 100 2 2 2 3 ~ 781 amu/sec 2 1 Fall off with increasing scan speed 100 Performance Electronics 2 1 2 3 ~ 781 amu/sec 2 0 ~ 6250 amu/sec Nearly no fall off with increasing scan speed 2 2 50 50 2 0 ~ 6250 amu/sec Moving from 2 3 to 2 2 doubles scans Phenanthrene Phenanthrene Page 11

Opiates, 38 ions (5 msec dwell) in 1 group, 10 SIM cycles/peak 280 C 1.75 min 200 C 0 min 20 C/min 3 min Page 12 For Research Use Only. Not for use in diagnostic procedures.

Synchronous SIM/Scan What is Synchronous SIM/Scan? Agilent s Synchronous SIM/Scan allows for the continuous collection of both SIM and Scan data in the SAME acquisition. More data without sacrificing sensitivity or library searching capability Great for target analysis (SIM) and identifying unknowns (Scan) SIM data for quantitation of targets Scan data for confirmation of unknowns Page 13

Agilent Synchronous SIM/Scan Alternating SIM (black) and scan (magenta) data collection 11.20 11.40 11.60 11.80 12.00 12.20 12.40 12.60 12.80 13.00 13.20 13.40 SIM + scan in one cycle, alternating rapidly High sensitivity + high information throughout the whole chromatogram Page 14

Agilent Instrumentation Used Gas Chromatograph 6890N with Autosampler (tray & injector) and split/splitless inlet Capillary NPD with extended jet G3180B - Microfluidic Splitter with Makeup Gas Mass Spectrometer 5975 inert MSD with EI source Software GC/MSD Chemstation G1701 DA version D.02.00 or higher (includes RTL and Screener) Column DB-17MS 15m x 250µm x 0.25µm part # 122-4712 Page 15

Method Parameters GC Oven Ramp Initial Ramp 1 Runtime Inlet Temp Mode Pressure Purge Flow Purge time Total Flow Agilent 6890N 'C/min 20 17 min 'C 80 320 Split/Splitless 280 'C Splitless 23.16 psi 50 ml/min 2.00 min 56.3 ml/min Hold min 0.00 5.00 MSD Solvent Delay Scan Range Threshold Sampling Quad Temp Source Temp Transfer Line Agilent 5975inert 2.5 min 42 to 450 0 2 2 for scan, 2 1 for SIMSCAN 150 'C 280 'C 280 'C Column Mode Pressure Initial Flow Outlet Outlet Pressure Injector Sample Washes Sample Pumps Injection volume Solv A washes Solv B washes Viscosity Delay Plunger Speed 0 6 2 ul 4 4 3 DB-17MS part # 122-4712 Constant pressure 23.16 psi 3.8 ml/min Splitter 3.8 psig Fast Page 16

Benzodiazepines 0.63 ng each to MSD Abundance 95000 90000 85000 80000 75000 70000 65000 60000 55000 50000 45000 40000 35000 30000 25000 TIC: _5uL_Scan_2.D\DATA.MS 20000 15000 10000 5000 0 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 1 2 3 4 1 Oxazepam 2 Lorazepam 3 Diazepam 4 Flunitazepam 5 Nitrazepam 6 Clonazepam 7 Alprazolam 5 6 7 Page 17 For Research Use Only. Not for use in diagnostic procedures.

Flunitrazepam- Scan Only Mode 0.63 ng Ion 312 Ion 286 Ion 285 S/N pk-pk 25.7 Ion 266 11.1 11.2 11.3 11.4 11.5 11.6 11.7 Page 18 For Research Use Only. Not for use in diagnostic procedures.

Flunitrazepam- SIM From SIM Only Run 0.63 ng Ion 312 Ion 286 Ion 285 S/N pk-pk 511 Ion 266 11.1 11.2 11.3 11.4 11.5 11.6 11.7 Page 19 For Research Use Only. Not for use in diagnostic procedures.

Synchronous Data Scan data file SIM data file Page 20

Comparison of Scan Only and Scan from SIM/Scan Ion 312 Extracted Ions From Scan Mode Ion 286 Ion 285 S/N pk-pk 26 3.51 Scans/sec Ion 266 Extracted Scan Ions From SIM/Scan Mode Ion 312 Ion 286 Ion 285 S/N pk-pk 32 3.59 Scans/sec Ion 266 11.1 11.2 11.3 11.4 11.5 11.6 11.7 Page 21 For Research Use Only. Not for use in diagnostic procedures.

Comparison of SIM Only and SIM from SIM/Scan Ion 312 Extracted SIM Ions From Scan Mode 25 msec dwell Ion 286 Ion 285 Ion 266 S/N pk-pk 511 6.20 Scans/sec Ion 312 Extracted SIM Ions From SIM/Scan Mode 25 msec dwell Ion 286 Ion 285 Ion 266 S/N pk-pk 327 3.59 Scans/sec Page 22 11.1 11.2 11.3 11.4 11.5 11.6 11.7 For Research Use Only. Not for use in diagnostic procedures.

Flunitrazepam-Advantage for Quant with SIM/Scan 0.63 ng Ion 312 Scan Extracted Ions From Scan Ion 286 Scan Mode Ion 285 Scan S/N pk-pk 25.7 Ion 266 Scan Ion 312 SIM Extracted SIM Ions From SIM/Scan Mode Ion 286 SIM Ion 285 SIM Ion 266 SIM S/N pk-pk 327 11.1 11.2 11.3 11.4 11.5 11.6 11.7 Page 23 For Research Use Only. Not for use in diagnostic procedures.

Synchronous SIM/Scan Library Searchable Spectra Abundance 1100 1000 Average of 11.343 to 11.366 min.: _5uL_Scan_1.D\DATA.MS (-) 285 312 Flunitrazepam 900 800 700 600 500 400 300 200 100 0 Abundance m/z--> 1100 1000 900 800 700 44 76 109 133 183 210 238 266 158 346 377 406 439 40 60 80 100120140160180200220240260280300320340360380400420440 Average of 11.335 to 11.365 min.: _5uL_SIMScan_2.D\DATA.MS (-) 286 312 Scan Only Spectra NIST Forward Match 837 Spectra from SIM/Scan 600 500 400 300 91 183 238 266 NIST Forward Match 826 m/z--> Page 24 200 100 0 109 50 133 74 165 210 377 331 440 358 405 40 60 80 100120140160180200220240260280300320340360380400420440 For Research Use Only. Not for use in diagnostic procedures.

Signal to Noise Improvement with SIM/Scan Ret Time Compound Tgt Ion A B Scan Only S/N pk-pk SIM/Scan Scan S/N pk-pk C D D/A SIM SIM/Scan Improvement only SIM factor S/N pk-pk S/N pk-pk # ions in SIM 9.940 10.338 10.490 11.353 12.327 12.733 13.168 Oxazepam Lorazepam Diazepam Flunitazepam Nitrazepam Clonazepam Alprazolam 267 239 256 285 280 280 308 43 87 242 50 6 8 18 49 60 388 42 12 11 24 687 787 2002 461 115 128 173 676 1098 2638 597 116 123 192 16 13 11 12 18 15 11 4 7 7 4 8 4 4 avg SIM and Scan performance of SIM/Scan is comparable to SIM only and Scan only modes 13.6 Page 25 For Research Use Only. Not for use in diagnostic procedures.

Permanent Splitter System GC/NPD/MSD 1:1 split NPD:MSD Auto-sampler AUX EPC 3.8 psig NPD Effluent Splitter with Makeup 0.532 m X 0.18 mm id 6890N GC Column 30 m X 0.25 mm id X 0.25 um HP-5MS 1.44 m X 0.18 mm id 5975 Inert MSD Page 26

ufluidic Splitter Hardware Deactivated microfluidic splitter operates to 350 C. Uses metal ferrules to eliminate leaks and retightening Column in To NPD To MSD Makeup from EPC Page 27

Three Signals from 1 Injection: Scan, SIM, and NPD 1.25 ng Each Compound 3 1 2 4 5 6 7 Scan TIC SIM TIC 1 Oxazepam 2 Lorazepam 3 Diazepam 4 Flunitazepam 5 Nitrazepam 6 Clonazepam 7 Alprazolam NPD 9 10 11 12 13 14 Page 28 For Research Use Only. Not for use in diagnostic procedures. TIC: _5uL_SIMScan_2.D\DATA.MS

Flunitrazepam Ion 312 Scan Extracted Ions From Scan Mode Ion 286 Scan Ion 285 Scan Ion 266 Scan S/N pk-pk 32 Ion 312 SIM Extracted SIM Ions From SIM/Scan Mode Ion 286 SIM Ion 285 SIM S/N pk-pk 327 Ion 266 SIM NPD S/N pk-pk 766 Page 29 11.1 11.2 11.3 11.4 11.5 11.6 11.7 For Research Use Only. Not for use in diagnostic procedures.

Flunitrazepam 1.25 ng Abundance 1100 1000 900 800 Average of 11.335 to 11.365 min.: _5uL_SIMScan_2.D\DATA.MS (-) 286 312 700 Scan from SIM/Scan Use for confirmation m/z--> 600 500 400 300 200 100 0 91 109 50 133 74 165 183 210 238 266 377 331 440 358 405 40 60 80 100120140160180200220240260280300320340360380400420440 Ion 312 SIM Extracted SIM Ions From SIM/Scan Mode Use for quant Ion 286 SIM Ion 285 SIM Ion 266 SIM S/N pk-pk 327 Page 30 NPD Use for confirmation and/or quant S/N pk-pk 766 11.1 11.2 11.3 11.4 11.5 11.6 11.7 For Research Use Only. Not for use in diagnostic procedures.

Why Does My NPD Peakshape Look So Good? NPD 9 10 11 12 13 14 Page 31 For Research Use Only. Not for use in diagnostic procedures. TIC: 25_NPDSIMScan2a.D\DATA.MS

NPD Jets, Standard vs Extended Tip Extended Tip extends ~ 9mm Analytes are positioned closer to the bead, minimizing tailing. G1531-80560 Standard Capillary Jet G1534-80580 Optional Capillary Jet with extended tip Page 32

Drug Standard by NPD using Different Jets pa 1000 *NPD1 B, (NPD\0202003.D) *NPD1 B, (NPD\0201001.D) 800 600 400 200 Blue is Extended Tip, less tailing Red is Standard Tip, more tailing 0 7.05 7.1 7.15 7.2 7.25 7.3 7.35 7.4 7.45 min Page 33

NPD Jet For Improved Nitrogen on 6890 There is a much better jet for nitrogen detection with the NPD: G1534-80580 NPD Jet Capillary Det G1534-80590 NPD Jet Universal Det G1530A-29 Service Note that describes best practices for optimal NPD operation [note: disregard suggested use of narrower collector] Page 34

QuickSwap MSD Interface Ease of Use Remove column w/o venting Backflush mode Inlet maintenance reverse flow Removes heavies from column Maintain constant flow to MSD Column EPC inlet MS Transferline Microfluidic technology Requires performance turbo for flow rates > 2 cc/min Page 35

3x Speed, 15m, Lemon Oil TIC, no spike Longer than normal run to elute heavies, another opportunity to save time using backflush Elution time of last pesticide =14 min 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 10 min at 320C needed after last target compound to elute oil 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 Page 36

Permanent Splitter System GC/NPD/MSD 1:1 split NPD:MSD Auto-sampler AUX EPC 3.8 psig NPD Effluent Splitter with Makeup 0.532 m X 0.18 mm id 6890N GC Column 30 m X 0.25 mm id X 0.25 um HP-5MS 1.44 m X 0.18 mm id 5975 Inert MSD Page 37

How Do You Backflush? Program inlet pressure to ~1.0 psi (may have to fine tune) Program make-up pressure to calculated value after last target peak elution time Use flow calculator to get pressure for make-up to splitter (aux EPC or PCM). MS restrictor flow < 10 ml/min at backflush temp Try a 3 void-times backflush, then run a blank for an extended time to make sure system is clean Shorten this time if blank is clean, in 0.5 min steps Performance Turbo a must Page 38

3x Speed, 15m, Lemon Oil TIC, no spike Blank before backflush run Backflush for 2.5 min at 300C instead of running an extra 10 min at 320C 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 Blank after backflush run Page 39

Spectral Deconvolution Extracts cleaner mass spectra from overlap situations easier, reliable identification Faster data review, a free second opinion from a mass spec expert When coupled with RTL and NPD data, gives higher quality identifications Can run searches of data not restricted by RT to find spectral brethren like designer drugs Page 40

AMDIS Deconvolution Pulls Out Individual Components and their Spectra TIC & Spectrum TIC Deconvoluted peaks and spectra Component 1 Component 2 matrix Component 3 Deconvolution interference target Page 41

Deconvolution Removes Spectral Interferences 3-Chloro-1,2-dibromopropane overlapped with fuel components 100 44 100 50 50 0 0 100 50 0 50 30 60 90 120 150 180 210 240 270 300 157 39 49 39 49 55 38 58 61 75 75 75 81 97 30 60 90 120 150 180 210 240 270 300 157 95 117 115 132 132 85 93 136 93 105 119 129 141 155 188 Raw Spectrum 70 th hit in NIST search 188 211 230 246 261 282 300 188 187199 211 227 246 261 280 300 Manual Subtraction 2 nd hit in NIST search Deconvolved Spectrum 1 st hit in NIST search NIST 05 Library 100 75 157 30 50 70 90 110 130 150 170 190 Page 42

DRS: 3 Integrated Processes Total ion chromatogram Targets are identified by locked R.T.s and 3 qualifier ions, then quantified using target ion area vs ISTD cal table Quant Results AMDIS 32 deconvolutes spectra and searches target MS database using locked RT as a qualifier Confirmed AMDIS hits Deconvoluted Target spectra confirmed by AMDIS, searched against NIST02 MS database Confirmed NIST05 hits Combined quantitative and qualitative HTML Summary report Page 43

DRS Report Page 44

Summary The 5975 and associated new products bring several new tools to the forensic analyst: Auto-CI SIMScan Splitters DRS Page 45