MDA-8000 DIO User Manual

Similar documents
DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Warranty. Warning. Copyright. Contact Us

8520/8520R. User Manual

SST-2450 Wireless Modem User s Manual

Industrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual

FR-2057iT. 16-channel Sink Type Isolated Output Module With Isolated Communication line. User Manual

GTM-204M-4G Industrial 4G LTE Modem User s Manual V1.0 High Quality, Industrial Data Acquisition, and Control Products

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

MODBUS-IN. Modbus Card. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

I-7000 and M-7000 DIO User Manual

I-7000 and M-7000 DIO User Manual

NetBiter I/O Extender User Manual

Features and Benefits. Certifications

I-7021, I-7022, I-7024, M-7022, M-7024 and M-7028 Series User Manual

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Serial to Ethernet Converter

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

Technical specification

RS 485 Mini Modbus 1AO

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RS485 MODBUS Module 6RO

Winsonic MODBUS Remote IO user manual Rev. 1.0

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Powered Roller Controller for DeviceNet

The I-7530A RS-232/485/422 to CAN Converter

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

I-7570 Serial To HART Converter

iologik R1200 Series User s Manual

ZigBee Converter User s Manual

GW-7228 J1939/Modbus RTU Slave Gateway

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

iothinx 4500 Series (45MR) Modules

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

iologik R1200 Series User s Manual

SCB-C08 USB to RS232/422/485 Converter

SER-4485-SI-M USER S MANUAL

TRP-C28 User s Manual

General. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6

General Specifications

General Specifications

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

ISO-DA16/DA8. Hardware Manual

RS485 MODBUS Module 16I-M

Signal Isolators & Conditioners

iologik R1200 Series User s Manual

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Remote I/O Product Specification

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

RS-485 I/O Modules: ADAM-4000

tsh-700 Series User Manual

Signal Isolators & Conditioners

RS485 MODBUS Module 8I8O

Technical Manual for RT-EX-9017

Remote I/O Product Specification

Product Manual. USB to RS232 TTL CMOS Adapter Cable with Terminal Block. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-232TTLMOS

ZigBee Products. ICP Electronics Australia Pty Ltd Overview P ZigBee Converters P5-2-1

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

INTELLIGENT I/O MODULE

Features and Benefits. Certifications

RS485 MODBUS Module 8I8RO

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

ZigBee Products 5.1 Overview P ZigBee Converters P ZigBee I/O Modules P5-3-1

BusBlock Digital I/O Module for the Smart Distributed System

The I-7530A-MR Modbus RTU to CAN Converter

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks

Analog signal to RS485 or RS232 Converter, A/D Converter

BACnet Controller for General-purpose Building Applications

BusBlock Digital I/O Module for the Smart Distributed System

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

JSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,

Signal Isolators & Conditioners

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

RS485 MODBUS Module 8AO

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

DATA ACQUISITION PRODUCT-ETHERNET

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Moxa TCC-100 Series User s Guide

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BusBlock Digital I/O Module for the Smart Distributed System

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions

Measurement Systems Datascan Installation and User Guide

TRP-C07 User s Manual

10 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-485. T Total Alarm x 1 + FRONT PANEL & KEY FUNCTIONS

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

ZLAN5443A. User Manual

Signal Isolators & Conditioners

Programmable Relay ZEN V2 Units

Transcription:

MDA-8000 DIO User Manual Warranty All products manufactured by Maxthermo-Gitta are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser. Warning Maxthermo-Gitta assumes no liability for damages resulting from the use of this product. Maxthermo-Gitta reserves the right to change this manual at any time without notification. The information furnished by Maxthermo-Gitta is believed to be accurate and reliable. However, no responsibility is assumed by Maxthermo-Gitta for its use, or for any infringements of patents or other rights of third parties resulting from its use. Copyright Copyright 2010-2011 MAXTHERMO-GITTA GROUP CORPORATION. All rights reserved. Trademark The names used for identification only may be registered trademarks of their respective companies. Table of Contents 1. 1.1 1.2 Introduction -------------------------------------------------------------------------------------- 2 Pin Assignment ----------------------------------------------------------------------------------------------- 2 Specifications -------------------------------------------------------------------- --------------- 3 1.3 Internal I/O Struction --------------------------------------------------------------------------------------- 4 1.4 Wire Connections ------------------------------------------------------------------------------------------- 5 1.5 Dimensions ---------------------------------------------------------------------------------------------------- 7 2. Communication Protocol ------------------------------------------------------------------------------------ 7 A.1 INIT Mode ----------------------------------------------------------------------------------------------------- 9 1

Introduction The MDA-8000 series is a family of network data acquisition and control modules, providing analog-to-digital, digital-to-analog, digital input/output and other functions. The modules can be remotely controlled using a set of commands, which we call the MODBUS protocol. Communication between the module and the host is in RTU format via an RS-485 bi-directional serial bus standard. Baud Rates are software programmable and transmission speeds of up to 115.2 Kbps can be selected. The MDA-8000 DIO modules support photo-isolated digital input, photo-isolated digital input and relay contact output. For details of INIT mode operation, please refer to Section A.1 INIT Mode. 1.1 Pin Assignment MDA-8316: MDA-8416: MDA-8508: MDA-8708: 2

1.2 Specifications System Specification: Model MDA-8316 MDA-8416 MDA-8508 MDA-8708 Communication Interface RS-485 Format N, 8, 1 Baud Rate 9600~115200 bps Protocol Modbus RTU LED Indicator Power Indicator 1 Communication Indicator 1 I/O Indicator 16 8 Isolation Voltage 3000V DC Power Input Range 24V DC ±10% Consumption Approx. 1W Reverse Polarity Protection With Environment Operating Temperature -25~+75 C Storage Temperature -40~+85 C Humidity 10~95% RH, Non-condensing I/O Specification: Model MDA-8316 Digital Input Channels 16 (Sink / Source) Input Type Isolated with Common Power or Ground Off Voltage Level +1V Max. On Voltage Level +4V to +30V Input Impedance 3KΩ Model MDA-8416 Digital Output Channels 16 (Sink) Output Type Open Collector (NPN) Load Voltage +3.5V to +50V Max Load Current 100mA per Channel Surge Protection ±3KΩ for Power Input 3

Model MDA-8508 Digital Input Channels 8 (Sink / Source) Input Type Isolated with Common Power or Ground Off Voltage Level +1V Max. On Voltage Level +4V to +30V Input Impedance 3KΩ Digital Output Channels 8 (Sink) Output Type Open Collector (NPN) Load Voltage +3.5V to +50V Max Load Current 100mA per Channel Surge Protection ±3KΩ for Power Input Model MDA-8708 Relay Output Channels RL0~RL2 RL3~RL7 Contact Type 1 Form C 1 Form A Rated Voltage 250V AC 250V AC Rated Current 5A 3A Mechanical Endurance 15 x 10 6 ops. 10 x 10 6 ops. Electrical Endurance 10 5 ops. 10 5 ops. 1.3 Internal I/O Struction MDA-8316: MDA-8416: 4

MDA-8508: MDA-8708: 1.4 Wire Connections MDA-8316: Dry Contact TTL / CMOS 5

MDA-8416: Drive Relay Resistance Load MDA-8508: Dry Contact Signal Input Resistance Load MDA-8708: Relay Output in RL0~RL2 Relay Output in RL3~RL7 6

1.5 Dimensions The dimensions of the MDA-8316 / MDA-8416 / MDA-8508 / MDA-8708 are as shown below. Unit : mm 2. Communication Protocol Interface RS-485 Baud Rate 9600 57600 19200 115200 38400 Data Frame Data bits = 8 Parity = None Start bit = 1 Stop bit = 1 Data Format MODBUS RTU Protocol 0 B0 B1 B2 B3 B4 B5 B6 B7 1 1 Start bit 8 Data bits 1 Stop bit PARA INDEX Description Attribute Address 00 Range : 1~255 R/W Baud Rate 01 0: 9600 / 1: 19200 / 2: 38400 / 3: 57600 / 4: 115200 R/W DI0~DI15 02 MDA-8316 MDA-8508 R DO0~DO15 03 MDA-8416 (DI0~DI7 / DO0~DO7) R/W RL0~RL7 04 MDA-8708 R/W 7

MDA-8316: PARA INDEX Description Attribute TIMER01 0005 Delay timer for DI0,Range:0.0~10.0 seconds R/W TIMER02 0006 Delay timer for DI1,Range:0.0~10.0 seconds R/W TIMER03 0007 Delay timer for DI2,Range:0.0~10.0 seconds R/W TIMER04 0008 Delay timer for DI3,Range:0.0~10.0 seconds R/W TIMER05 0009 Delay timer for DI4,Range:0.0~10.0 seconds R/W TIMER06 000A Delay timer for DI5,Range:0.0~10.0 seconds R/W TIMER07 000B Delay timer for DI6,Range:0.0~10.0 seconds R/W TIMER08 000C Delay timer for DI7,Range:0.0~10.0 seconds R/W TIMER09 000D Delay timer for DI8,Range:0.0~10.0 seconds R/W TIMER10 000E Delay timer for DI9,Range:0.0~10.0 seconds R/W TIMER11 000F Delay timer for DI10,Range:0.0~10.0 seconds R/W TIMER12 0010 Delay timer for DI11,Range:0.0~10.0 seconds R/W TIMER13 0011 Delay timer for DI12,Range:0.0~10.0 seconds R/W TIMER14 0012 Delay timer for DI13,Range:0.0~10.0 seconds R/W TIMER15 0013 Delay timer for DI14,Range:0.0~10.0 seconds R/W TIMER16 0014 Delay timer for DI15,Range:0.0~10.0 seconds R/W 8

MDA-8508: PARA INDEX Description Attribute TIMER01 0005 Delay timer for DI0,Range:0.0~10.0 seconds R/W TIMER02 0006 Delay timer for DI1,Range:0.0~10.0 seconds R/W TIMER03 0007 Delay timer for DI2,Range:0.0~10.0 seconds R/W TIMER04 0008 Delay timer for DI3,Range:0.0~10.0 seconds R/W TIMER05 0009 Delay timer for DI4,Range:0.0~10.0 seconds R/W TIMER06 000A Delay timer for DI5,Range:0.0~10.0 seconds R/W TIMER07 000B Delay timer for DI6,Range:0.0~10.0 seconds R/W TIMER08 000C Delay timer for DI7,Range:0.0~10.0 seconds R/W A.1 INIT Mode INIT mode: To return to the ex-factory parameters. When users forgot the previous settings and is unable to use the module, it is able to use this mode to return to the initial setting. Ex-factory settings as below: Address: 1 / Baud Rate: 9600 Operation: When the module is powered on, please short 13 (B)GND pin and " 9 INIT pin" then power off the module. When the module is powered on again, it will return to the ex-factory setting. 9