LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies

Similar documents
LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

Manson Engineering Industrial Ltd. Power Supply Control Software. User manual

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Laboratory Switch Mode Power Supply Series. Instruction Manual

NTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL

LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies. SDP Series SDP 2210 / 2405 / 2603 User Manual

HCS-USB Series PC Interface Software

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply PSC-6916 PSC-6932 PSC A 30A 15A

Programmable Switching DC Power Supply

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

Model DCP42 160W Laboratory Grade Constant Power, Switching Mode Power Supply

Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this

CIRCUIT-TEST. Switching Mode Power Supply with USB Remote Control PSC VDC / 5A PSC VDC / 3A PSC VDC / 1.

Model DCP60 and Model DCP Switching Mode DC Power Supplies 60V / 10A Adjustable USER GUIDE

High Precision Quad Output DC Power Supply

User's Guide. Model W 3-in-1 Switching DC Power Supply

Programmable DC Power Supplies XLN Series

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

1-36V, 0-3A DC Power Supply

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

80W (16V/5A) Power Supply with USB Output. User Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

USER S MANUAL Linear Programmable DC Power Supply APS

Multiple Output Linear DC Power Supply

Remote Programmable Linear Regulated Power Supply User Manual INSTRUCTION MANUAL

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply PSC-6118 PSC-6136 PSC A 5A 2.5A

3700 SERIES USER MANUAL

User Guide. TP3016M Series Switching Mode DC Power Supply

BENCHTOP INSTRUMENT. Programmable Switching DC Power Supply Operation Manual V1.0

User's Guide. Model High Precision Quad Output DC Power Supply

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

ODP Series Dual Output Linear Programmable DC Power Supply User Manual

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

DC Power Supply Models AX501, AX502 & AX503

USER MANUAL. RND 320-KA3000 Series

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Universal AC Power Source + AC Power Analyzer

Pro II. Sound Level Meter V-9992

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

User s Manual PROGRAMMABLE DC POWER SUPPLY

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

DATA-CONTROLLED POWER SUPPLY 3645A-TYPE. Operating Manual

USER S MANUAL DC REGULATED POWER SUPPLY

Programmable Digital Controlled DC Power Supplies

An ISO 9001 Company. KLP POWER SUPPLY

AIM & THURLBY THANDAR INSTRUMENTS

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent E3632A DC Power Supply

EPS Power Supply

TSX SERIES High power laboratory DC Power Supplies

AIM & THURLBY THANDAR INSTRUMENTS

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet

AIM & THURLBY THANDAR INSTRUMENTS

PS2328 Integrated Power. System

RIGOL. User s Guide. DP1116A Programmable DC Power Supply. Mar RIGOL Technologies, Inc.

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

Series 8000 RF Signal Switch Solution

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

USER S MANUAL DC REGULATED POWER SUPPLY DIGITAL CONTROL DC REGULATED POWER SUPPLY

PS U Series W to 3000 W. Programmable DC Power Supplies THE POWER TEST EXPERTS.

BENCHTOP INSTRUMENT. Programmable DC Power Supply Operation Manual V1.0

Multiple Channel Digital Control and Programmable DC Power Supply Model: , , and

PS-3005P Programmable DC Power Supply

User s Manual PROGRAMMABLE DC POWER SUPPLY APS-7303/7303L/7305/7305L

Swift Responses with Accurate Measurement

NEW! ZERO-UP. Control Flexibility for Worldwide Applications 200W/400W/800W. Built-in RS232 & RS485 Interface with GPIB optional.

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

RIGOL. User s Guide. DP1308A Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

User s Manual. Sound Level Meter. FSM 30Plus. Lo/Hi MAX HOLD S/F. S F db BAT. SOUND LEVEL: Lo=35~100dB Hi=65~130dB. 94dB

MT /12-Slot Digital MultiTasker

SSW06. Soft Starters.

Control system for rotary heat exchanger EQRB, L=3,4

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

REGULATED DC POWER SUPPLIES

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

1 INSTRUCTION 2 SPECIFICATIONS 3 USER GUIDE 1. Output voltage 0-32V Output current. 0-1A( CA19101DH) 0-3A( CA19103DH) 0-5A( CA19105DH) Source effect

R&S HMC804x Power Supply 100 W and 1, 2 or 3 Channels

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

DMX Tool Splitter 1 to 5 User Manual

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

Variable Regulated DC Power Supplies PAD-LA Series

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

E36300 Series Triple Output Bench Power Supply DATA SHEET

PS-5030 (5A) OPERATION MANUAL

Transcription:

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies SDP Series SDP-361836363660 User Manual

Table of Contents Table of Contents 1 2 3 4 Safety Instructions...3 Technical Specification of SDP Series Power Supply...4 Introduction...5 Front panel...6 4.1 Annotation...6 5 Operation with Main screen...8 5.1 Enter and exit Output Setting screen...8 5.2 Change output Voltage and Current setting...8 5.2.1 Use JOG to change output setting...8 5.2.2 Use Keypad to change output setting...8 5.3 Change output by recalling Preset value...9 6 Main Setup MENU...10 6.1 Main Setup MENU...10 6.2 System Setting MENU...10 6.2.1 LAN Setting...11 6.2.2 Language Setting...12 6.2.3 Date Time Setting...12 6.2.4 System Parameter Setting...13 6.3 Internal program setup...14 6.3.1 Edit steps for internal program...14 6.3.2 Internal program startstop...15 6.4 Display power supply information...16 6.5 Datalog operation...17 7 PC Interface Control User Manual...19 7.1 Main Display...19 7.2 Connect to Power supply...20 7.3 Display panel...23 7.4 Set output voltage value, current value and ONOFF status...23 7.5 Internal Timed Program...24 7.6 External Timed Program...26 7.7 Set Upper limited of Voltage and Current...27 7.8 Firmware upgrade...27

1 Safety Instructions The following safety precaution must be observed during all phase of operation and service of this equipment. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. General Safety Instructions Do not use the unit near water. Do not install unit near heating sources and heating emitting devices. Clean only with dry cloth. Do not block the fan ventilation. Prevent the power cord from being walked andor pinched. Unplug this unit when not use. Unplug this unit during lighting and storms. Do not open the cover of the unit during operation. Never replace components when the power cable is connected. Always disconnect power, discharge circuit and remove external voltage before touching components. Only use optional accessories with this unit. Please contact qualified service personnel for repair. Supply Input Range The unit is of universal input : 100 240 Vac, 50Hz 60Hz.

2 Technical Specification of SDP Series Power Supply Models SDP-3618 SDP-3636 SDP-3660 Variable Output Voltage 1 18 VDC 1 36 VDC 1 60VDC Variable Output Current 0 20 A 0 10 A 0 5A Output Rated Power 360W 360W 300W Output Voltage Regulation Load (10-100% Rated Current) 50mV Line (90-264Vac Variation) 20mV Current Regulation Load (10-90% Rated Voltage) 50mA Line (90-264V Variation) 50mA Ripple & Noise Ripple & Noise (r.m.s) Voltage 5mV Ripple & Noise (peak-peak) Voltage 50mV Output Tracking OVP OP 1-5V : set voltage +2V OP 5-18V : set Voltage +3V OP 1-5V : set voltage +2V OP 5-20V : set Voltage +3V OP 20-36V : set Voltage +4V OP 1-5V : set voltage +2V OP 5-20V : set Voltage +3V OP 20-36V : set Voltage +4V Meter Type & Accuracy Display Meter Color LCD (4 digit - Ammeter, Voltmeter & Power meter) Meter Accuracy ±1% +5counts for V<5V, I<0.5A ; ±1% +2counts for V<5V, I<0.5A LCD Dimension 48 x 66mm Input Voltage 90-264VAC 5060Hz~ Full Load Input Current (230VAC100VAC) 2.14.6A 2.14.6A 1.73.8A Efficiency (230VAC) 85% 86% 86% Power Factor Control Power factor correction >0.95 at optional load Cooling Method Thermostatic Control Fan from Zero to full speed Operating Temperature 0-40 C Protections Overload, Short Circuit by Constant Current, Output Tracking Over Voltage, Over Temperature Approvals CE EMC: EN 55011, 55022 LVD: EN 60950, 61010 Dimensions 193x98x215 mm Weight Approx. 2.4 kgs 5.2lbs Accessories User Manual 7.6x3.9x8.5 inch Remote Programmable Specifications Communication Interface USB 2.0, RS-485, 10 100Mb Ethernet Remote Programming Functionality Full Control of Power Supply Functions and Data Read-back Data Logging Yes, with supplied software All values are based on the Standard ambient Temperature 25 C and Pressure 0.1Mpa.

3 Introduction The SDP series of high performance programmable with new advanced microprocessor technology allow programming and setting of all parameters on the unit's key pad without the use of PC. The color LCD display facilitates settings of multiple parameters and real time output VIW wave form. The convenient closed housing firmware upgrade and calibration procedure allow up keeping of the optimal state of the power supply. The power supplies come with Ethernet, USB and RS-485 ports for remote control, Programming, Monitoring and Data Logging via PC interface through SCPI commands. Groups of control settings and cyclic sequence can be stored in the PC and input to the selected power supply via Ethernet, RS-485 and USB. When using RS-485, one PC can control and data log as many as 31 power supplies of the same series. There are features in this new series that are only found in higher price category power supplies. This series of power supplies have obtained the safety approval EN-61010 and EN55011 EMC approval for scientific, industrial equipment of the CE directives. Features 360W single output laboratory grade programmable switching mode PS. Color LCD displays multiple parameters & real time output V I W graph. Full Panel setting of cyclic Program and all System parameters including LAN. Full Remote Programming, monitoring and data logging. One PC can control, monitor and data log up to 31 power supplies via RS-485. One PC can control, monitor and data log any number of power supplies via Ethernet. Built in Ethernet, RS-485 and two USB ports. One device USB port for remote programming, control and data logging. Local and Remote programmable cyclic run of 20 sets V, I, Time and up to 999 cycles. Supplied with control software, SCPI command sets, and LabView driver. Convenient close housing calibration and firmware upgrade. 4 digit ammeter, voltmeter and power meter. Tracking OVP plus user defined max. output voltage. 9 user presets of voltage and current limit at the key pad.

4 Front panel 4.1 Annotation 1. Power Supply Identity : It can assign a number, which from 1 to 254, for Power Supply to identify it. 2. Output Voltage display : Showing the output voltage. 3. Output Current display : Showing the output current. 4. Output Power display : Showing the output power. 5. Status bar : Show this status of power supply. It included - The power supply operating in Constant Current mode - The power supply operating in Constant Voltage mode The power supply is in Over Voltage Protection The power supply is in Over Current Protection The power supply is in calibration mode - The power supply is in remote control, all keypad is locked in the mode. - The output is ON - The output is OFF - The keypad is locked - The keypad is unlocked - The power supply is running internal program

6. Keypad definition Keypad Function thru Press to select numerical values Press to ascend numerical values Press to move highlight upward Press to descend numerical values Press to move highlight downward In Main screen, use to enter program step menu. In Setup Menu screen, exit to one level up. In Main screen, use to enter Menu. In Setup Menu screen, use to confirm setting In Main screen, use to lock and unlock keypad. In numerical input area, use to enter decimal point. Setting output ONOFF 7. JOG The JOG has 5 functions. - During the setting of Voltage or Current, rotate to increasereduce value of setting. - In Voltage or Current setting, press to move to different digit for setting. - In menu screen, press to select all. - In menu screen, rotate to move selection to rightleft. - Reset during input value

5 Operation with Main screen Power Supply 01 Power Supply 01 12.15 V 5.25 A 63.78 W 12.15 V 5.25 A 63.78 W Basic screen 1.Preset : 0 Output Setting: 2.Volt: 12.15V 3.Curr: 8.00A Output setting screen The Main screen of SDP has two parts. - Basic screen shows actual output status of power supply. - Output Setting screen shows actual output status as well as output setting area. You can recall Preset setting, set output Voltage and Current in this screen. 5.1 Enter and exit Output Setting screen Rotating JOG anti-clockwise to pull out Output Setting screen. You can rotate JOG clockwise or press to exit Output Setting screen. The Output Setting screen will automatically exit after ideal for 2 minutes. 5.2 Change output Voltage and Current setting It has 2 ways to change output setting for Voltage and Current. 5.2.1 Use JOG to change output setting By using JOG to change output setting, the actual output will effective immediately when you are rotating the JOG. i. Enter Output Setting screen. ii. Highlight VoltageCurrent by using. iii. Rotate JOG clockwiseanti-clockwise to increase and decease setting. iv. Press JOG highlight to different decimal place for cross and fine adjustment. v. Press to exit 5.2.2 Use Keypad to change output setting You can direct key-in value in setting area to change output setting. The output will only effective after press to confirm. i. Enter Output Setting screen. ii. Highlight VoltageCurrent by using.

iii. iv. v. Direct key-in value. e.g. To set 12.34V, then key-in 1234 Press to confirm setting. If you make mistake during key-in, press to clear and restart key-in. 5.3 Change output by recalling Preset value You can recall Preset 1 to 9 to set output value quickly. i. Enter Output Setting screen. ii. Highlight Preset by using. iii. Enter number 1 to 9 for step you prefer. (If you forget the setting, press JOG once to show all of them.) iv. Press to confirm. * The first 9 step is commonly used with Preset 1 to 9.

6 Main Setup MENU SETUP MENU SYSTEM SETTING INTERNAL PROGRAM DISPLAY INFORMATION DATALOG OPERATION This model of SDP is using Menu Base operation. The Setup Menu can preform following 4 things. - Configure System Setting - Configure Internal Program - Show system information - Perform Datalog operation 6.1 Main Setup MENU Press can use in basic screen to enter main SETUP MENU. It content 4 sub-menus. You key to move to different menu. You can also press number 1 to 4 to quick move between menus. 6.2 System Setting MENU Select SYSTEM SETTING in main SETUP MENU then press to enter System Setting menu. You can configure LAN setting, Language setting, Date Time setting and System Parameter in this sub-menu. SYSTEM SETTING 1.LAN SETTING 2.LANGUAGE SETTING 3.DATE TIME 4.SYSTEM PARAM

6.2.1 LAN Setting LAN SETTING 1.Lan Type: DHCPSTATIC 2.IPAddr: 192. 168. 1. 250 3.LanMask: 255. 255. 255. 0 4.Gateway: 192. 168. 1. 5 In SYSTEM SETTING menu, use to move to LAN SETTING. Then press. ii. Configure LAN type You can configure power LAN card use DHCP or Static. Use to move to Lan Type setting. The rotate JOG to select between DHCP and Static. Then press to confirm setting. i. iii. Configure IPv4 address To configure IPv4 address of power supply. Use to move to IPAddr line. Direct key-in IP address. Use JOG to move between 4 segments of IP address. If you input incorrect number, the number will highlight in red color. You can press JOG once to start over input another value. iv. Configure LAN mask Use to move to LanMask line. Direct key-in Netmask of your network using. Use JOG to move between 4 segments of netmask setting. v. Configure default gateway Use to move to Gateway line. Direct key-in IP address of your network default gateway. Use JOG to move between 4 segments of default gateway setting. vi. Finally press to confirm and exit LAN setting.

6.2.2 Language Setting LANGUAGE SETTING 1.English 2. 简体中文 3. 繁體中文 This power supply support multi-language setting for MENU. i. In SYSTEM SETTING menu, use to move to LANGUAGE SETTING. Then press. ii. Then press to enter language setting menu. iii. Select your prefer language for menu. iv. Press to confirm and exit setting. Then menu will change to language you selected. 6.2.3 Date Time Setting DATE TIME 1.Date: 2015-02 - 16 2.Time: 15 : 29 : 37 You can configure date and time i. In SYSTEM SETTING menu, use to move to DATE TIME. Then press ii. Then Use to move to Date configuration line. iii. Direct key-in date. The date format is yyyy-mm-dd. iv. Use to move to Time configuration line. v. Direct key-in time. vi. Press to store and exit..

6.2.4 System Parameter Setting SYSTEM PARAM SYSTEM PARAM 1.KeySound: OFF ON 5.UVL Setting: 60.00 V 2.Alarm: OFF ON 6.UCL Setting: 5.00 A 3.SystemID 254 4.Lan Port 8888 You can set KeySound ONOFF, Alarm ONOFF, System ID number, LAN Port for remote control, UVL and UCL in this sub-menu. i. In SYSTEM SETTING menu, use to move to SYSTEM PARAM. Then press. ii. Use to move to KeySound setting line, then rotate JOG to select ONOFF. iii. Use to move to Alarm setting line, then rotate JOG to select ONOFF. iv. Use to move to SystemID line, then direct key-in number 1 to 254. The number will turn to red if you input invalid number. Press to confirm the input. v. Use to move to Lan Port line, direct key-in port number for remote control. e.g. IP address is 192.168.1.100 and port number is 8888. The remote control software can be connect to system through 192.168.1.100:8888. vi. Use to move to UVL setting, direct key-in upper voltage limit which range is between 1V to maximum rating voltage for model. vii. Use to move to UCL setting, direct key-in upper current limit which range is between 0.01A to to maximum rating current for model.

6.3 Internal program setup INTERNAL PROGRAM Step Volt [V] Curr [A] Dura [s] 01 6.60 2.00 10 02 5.00 1.51 5 03 12.00 3.25 3 04 13.00 2.75 20 05 20.00 6.55 7 The internal program has 20 steps for user to define voltage, current and duration of each step to be running. * The first 9 step is commonly used with Preset 1 to 9. 6.3.1 Edit steps for internal program i. Select INTERNAL PROGRAM in Setup Menu, then press screen. to enter above menu ii. Rotate JOG to show steps you would like to edit. iii. Press once, the Voltage setting area of the step will be highlighted for edit. iv. Direct key-in value you would like to set. Use Press 1 2 3 4) for input dot. (e.g. 12.34 v. Rotate JOG to Current setting area to edit current. vi. Rotate JOG to Duration setting area to edit running duration. vii. If finish the editing, press twice to exit. If continuous to edit other step, rotate JOG to highlight Voltage setting area. Then press to move to nextprevious steps to edit. viii. If you would like to exit without save the change, press to exit editing.

6.3.2 Internal program startstop The above internal program running menu content 4 parts. Part 1 Indicate program is running or stopped Part 2 Indicate and edit start running step, end running step and number of cycles to be run. Part 3 Reminder for Exit key, Start key and Stop key. Part 4 Steps review windows i. Press in Main screen to pull up above internal program running menu. ii. Rotate JOG to review steps. iii. Press to move between Start, End and Cycles input space. iv. Enter setting use keypad. (e.g. The above example is run from 1 to 9 for 8 cycles) v. Press to start running. When vi. If the program is running, press again to stop. When the internal program is running. The screen will show following stepping view. It shows voltage, current and duration of step. As well as cycle and step are running. Power Supply 01 12.15 V 5.25 A 63.78 W Stepping View: Volt: Curr: Timer: 12.15 V 6.00 A 3 Current Cycle: 7 Current Step: 8

6.4 Display power supply information DISPLAY INFORMATION 1.SYSTEM INFORMATION 2.LAN INFORMATION You can check system information and LAN setting information in Display Information sub-menu. i. Select DISPLAY INFORMATION in Setup Menu, then press to enter above menu screen. ii. Use to select system information, then press information. to show system SYSTEM INFORMATION System ID: 254 Serial Number: G131504554 HW Version : 1.0.0 SW Version : 1.1.3 iii. Use to select LAN information, then press information. to show LAN setting LAN INFORMATION addr:192.168.1.100 Bcast: 192.168.1.255 Mask: 255.255.255.0 Hwaddr: 1E:A1:1A:9A:AD:BF

6.5 Datalog operation DATALOG OPERATION 1.LOG CONFIGURE 2.CHART DISPLAY The datalog operation menu allow you to setup sampling time in second and display output graph for Voltage, Current and Power of power supply. i. Select DATALOG OPERATION in Setup Menu, then press menu screen. ii. Use to enter above to select Log Configure sub-menu. LOG CONFIGURE Sample Time Sample Length 1 300 iii. Press to highlight Sample Time setting. The Sample Length is maximum data logging time in second. (The maximum time is limited due to memory size of storage used to to store data.) iv. Press to exit.

v. Use to select Chart display. The following output Chart will come up. (You can also press key 1 in basic main screen to quick access to this display.) CHART DISPLAY vi. It allow you to change display scale for Voltage, Current, Power and Time. Press JOG to select between V:, C:, P: and T: on the top of chart display. Then rotate the JOG to adjust display scale for selected display. vii. You can press to exit.

7 PC Interface Control User Manual Support OS: Windows XPVista78 USB Driver: Silicon Lab CP210x USB driver (Included in CDROM folder USB CP210x Drivers V6.6.1 for Win_XP_2003_Vista_7_8 ) Execute Program: run <CDROM Drive>:\pscs\pscs.bat 7.1 Main Display The Main interface divided into 6 panels. 1. 2. 3. 4. 5. 6. Display panel use to display real-time information of power supply. Main configuration and data log display panel use to change general setting of program and display data log. Setting panel use to set incident voltage value, current value and output OnOff. Data handling panel use to save, load and print data. Description input panel use to enter description for wave form Information panel use to display Maximum voltage current, Sampling time, upper voltage current limit and software version.

7.2 Connect to Power supply Before edit any connection setting, the software will not connect to power supply. It just show following display. The first thing you need to do is to edit correct connection for your system. If there are saved connection setting in software. The software will search power supply and connect automatically. Connection editing steps i. Select Setting tab

ii. Click on to start edit connection. The connection edit panel come up. iii. Enter connection name for this connection setting and select your power supply model. e.g. SDP-3660 iv. Enter Description of system.

v. Select connection type for your system. It allow configure for USB, Ethernet and RS485. Select USB in this case. vi. Select COM port for your system e.g. COM3 vii. Then Click to save setting then click to exit the edit page. The final setting for this page is like this. After save configuration, the power supply connect automatically. The display change as follow.

7.3 Display panel C.V. and C.C. mode display Voltage and Current Setting values display C.V. and C.C. mode display Display actual output value of Voltage, Current and Power The display show following information - Output Voltage value - Output Current value - Output Power value - Output OnOff status - C.V. C.C. Model - Setting values 7.4 Set output voltage value, current value and ONOFF status Voltage Setting Current Setting Output ONOFF setting Confirm It allow direct input voltage value and current value in setting area or use slide bar to adjust value. After adjust the value, then click button to confirm setting.

7.5 Internal Timed Program Select Internal Timed Program tab to operate with 20 internal steps program. It can define Voltage, Current and running time for each step. User can setting running cycle for the Timed Program for specified steps range. It has an Internal Timed Program Description space for user to enter description for the setting. The description will be saved when user select to save setting into CSV file. - Click to read internal setting from power supply. - Double click on the cell that you would like to set value. For example Step 1 voltage. - Slide the bar to configure the value. - Set time for this step to be running. The time range is between 0 to 9hours 59 minutes 59 seconds. You can click updown button to change value or directly input value. If the time value is set to 0, this step will be skipped. Slide the bar to configure the value. - Click to save the setting back to power supply. - Input range of steps and cycle you would like to run from internal timed program.

- Click - Click to execute the selected range and number of cycle. to clear the setting.

7.6 External Timed Program Select External Timed Program tab to operate with 20 user define steps program. It can define Voltage, Current, running time and Output ONOFF for each step. User can setting running cycle for the Timed Program. External Timed Program is completely controlled by PC, PC counts the time and changes voltage and current of power supply. It has an External Timed Program Description space for user to enter description for the setting. The description will be saved when user select to save setting into CSV file. - Double click on the cell that you would like to set value. For example Step 2 voltage. - Slide the bar to configure the value. - Set time for this step to be running. The time range is between 0 to 9hours 59 minutes 59 seconds. You can click updown button to change value or directly input value. If the time value is set to 0, this step will be skipped.

Select running cycle between 0-999. You can use slide bar to select or directly input value in text box. Input 0 means run the program forever. - Click button to start running cycle. In between program running cycle, click - Click button to stop program. to clear the setting. 7.7 Set Upper limited of Voltage and Current Select Setting tab to configure Voltage Upper Limit (UVL) and Current Upper Limit (UCL). If you set the UVL and UCL, all setting in General Output setting, Internal Timed Program and External Timed Program cannot higher than this limit. You will find the setting become red to alert you it is over the UVL or UCL. In the setting tab, - Direct input your setting value or using slide bar to configure for the UVL an UCL. - Click button to save the setting to power supply 7.8 Firmware upgrade * WARNING : PLEASE DO NOT POWER OFF POWER SYSTEM OR DISCONNECT POWER SUPPLY FROM PC OR CLOSE PC SOFTWARE DURING FIRMWARE UPDATE PROCESS. OTHERWISE, THE POWER SUPPLY WILL BE DAMAGED. SDP power supply allow user to upgrade firmware through Manson provided software. - Select Setting tab - Click to enter follow firmware upgrade page

- Click to load firmware image file - Select the image file in Open File interface - After load firmware image file, then click update. - After update success, the power supply will reboot. to start transfer image to power supply and