Olympus IX-70 Imaging Protocol

Similar documents
Olympus IX-70 Imaging Protocol

Spinning Disk Protocol

Zeiss AxioImager.Z2 Fluorescence Protocol

Start-up system. Nikon Wide Field Microscope Ee1078. Complete manual

ANDOR/OLYMPUS SPINNING DISK USER GUIDE

DSU Start-Up instructions

Use of the Binocular Microscope

Nikon A1-B Confocal Operating Manual. Start-up. Microscope

Confocal 6 Guide. Switching On Components of the system should be switched on in the following order: 1. Lasers Argon laser (488nm and 514nm)

LSM510 Confocal Microscope Standard Operation Protocol Basic Operation

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

Lab 5 Microscopy. Introduction. Carrying the Microscope. Depth of Focus. Parts of the Compound Microscope. Magnification

Olympus DeltaVision Microscope Start-Up and Shut-Down Instructions.

Cell Imaging Unit UIC Bárbara Fekete ZEISS AXIOIMAGER MICROSCOPE MANUAL

Heit/Kerfoot/Dikeakos. Leica DMI6000 B. User Manual

Basic Users Guide for the LSM 510 Confocal Microscope

LEXT 3D Measuring LASER Microscope

The Microscope. Lab Exercise. Contents. Light Microscope. Objectives. Scanning Electron Microscope. Introduction. Transmission Electron Microscope

Olympus BX51 on Aura. Introduction to the NRI-MCDB Microscopy Facility BX51 Upright Microscope

Hand sectioning a mushroom

Primary Use. Operating Principle

I. Use and Care of the Microscope:

Indiana Center for Biological Microscopy. BioRad MRC 1024 MP Confocal & Multi-Photon Microscope

Zeiss Z.1 Lightsheet. Quick-Start Guide

Introduction to the Microscope. Hanan Jafar BDS.MSc.PhD

Manual ANGSTROM grid confocal microscope

Zeiss Elyra Microscope Standard Operation Protocol Basic Operation

Introduction to the Microscope. Types of Microscopes Care Parts Focusing

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

Introduction to the Microscope. Types of Microscopes Care Parts Focusing

Richter Optica. Instructions for Model F-1 Compound Microscope

Lab 4 - The Microscope

Multi-Photon Training

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

INTRODUCTION - VetScan HDmicroscope

Visitron Spinning Disk Unit 1

Binocular Compound Microscope Instruction Manual

PCIC Plant Cell Imaging Center (BTI, room 104B) CONFOCAL LEICA SP5 user manual

Compound Microscope Instruction Manual

Biology 105 Laboratory 1: Microscope

Samples Carolina sample slides (pollen, algae, ). Clean off oil with lens paper then OpticPad around lens (metal not glass) when done.

Quick Set-up Guide for the Biomedx Configured Olympus CX43

Polarization Microscope. Omano OM349P Series. User Guide

Microscope Introductory Lab Series

Richter Optica. Instructions for Model: MDS1 Compound Microscope

OIC. User Guide to Confocal Microscope: Zeiss LSM Pascal

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Teaching Microscope Instruction Manual OMTM85 and OMTM85L

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

Why were cells not discovered before the 17th century?

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

ABM's High Resolution Mask Aligner Features:

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

LSM 5 MP, LSM 510 and LSM 510 META Laser Scanning Microscopes

Comprehensive Scope 2. Instruction Manual T-19011C - Monocular T-19021C - Dual Viewing T-19031C - Binocular T-19041C - Trinocular

All-In-One. digital inverted microscope. High-quality Imaging Has Never Been Easier. evos-ca.com

Instruction Manual. B3 Series. Copyright 02/02 Motic Microscopes, European Division

BIOLOGICAL MICROSCOPE

Confocal Microscope - Radiance. Basic Instructions. (Stefanie Reichelt) The Radiance. Confocal Scanning Microscope. designed and developed by

M20 Metallurgical Microscope User s Manual. Fein.

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

Wide Guy: Inverted Widefield Microscope

User Manual. Binocular Compound LED Microscope. MicroscopeNet.com

Biology Shared Instrumentation Facility Olympus IX70 Inverted Microscope and Simple PCI Imaging System

Renishaw invia Raman Microscope (April 2006)

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE. TECHSPEC Optical Cage System

TN425: A study of fluorescence standards confirms that OptiGrid confocal images are suitable for quantitative microscopy

Bell Work: Brainstorm: What s the smallest thing that can be seen with current microscope technology? Please raise your hand when you have your idea!

University of Minnesota Nano Fabrication Center Standard Operating Procedure

Quick Start Guide - cellsens

CoSMoS Starter Guide 1.4 Hoskins Lab Last Modified 03/03/2017 Chris DeCiantis

Transmission Polarizing Microscope OM239

Culture Microscope CKX53. CKX3 Series. The Cell Culture Laboratory Solution

For documentation, both instruments are available with a trinocular head which permits mounting of a video or digital camera system.

Richter Optica. Instructions for Model: HSX1 High School Microscope

Zeiss LSM 510 Meta inverted confocal manual

User Manual. Trinocular Stereo Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Operation Instruction

CoSMoS Starter Guide 1.6 Hoskins Lab Last Modified 03/30/2017 Chris DeCiantis

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

EXPERIMENT. Microscopy for Microbiology Use and Function

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

USE OF THE MICROSCOPE

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope

Mi50 Inverted Microscope User s Manual. Fein.

1. Getting Started: Brief Step-By-Step Guide (PDF File)

Olympus cellsens TIRF Guide

System Microscope CX41. CX2 Series. Optics and Performance Outstanding in its Class

Leica TCS SP8 X Confocal Microscope and Leica Application Suite X software DRAFT VERSION Room B123b

Oxion. Microscopes for Life Sciences ENGLISH

3-D. Here red spheres show the location of gold nanoparticles inside/around a cell nucleus.

Great Bay Community College Document Number: Corporate Drive Revision Number: 3

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Olympus cellsens Live/TIRF Unit

3025 MICROSCOPE SERIES INSTRUCTIONS

INVERTED MICROSCOPE CKX41/CKX31. A new advance in routine inspections UNIVERSAL INFINITY SYSTEM

Operating Procedure for Horiba Raman Microscope

Cordless Comprehensive Dual Purpose Scope. Instruction Manual T-1931C T-1932C T-1933C

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Transcription:

Olympus IX-70 Imaging Protocol 1) System Startup F Please note our sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time. The facility will allow for extenuating circumstances (cells dying, sick day, etc.) if you inform us in a timely fashion. F Follow each step of the startup poster, log into your account, and open Metamorph software. 2) Lens Cleaning F If necessary, please lift the condenser by its centering screws (highlighted in red) as shown below: F Please clean all of the lenses (used and unused) before your session and afterwards if you use the 60x oil immersion lens. Refer to the lens cleaning poster if you need any help recalling the rules and steps. 3) Microscope control and loading your sample F To load your slide, plate, or dish and take care for the following issues: Make sure that the stage adapter that correctly matches your sample fits securely and flush with the stage. For slides: Select and inspect each slide. If it is dirty, gently clean with a KimWipe and/or cotton swab. You should do this with all of your slides before you come. F Use the stage movement joystick to position your specimen over the lens. For faster movement, hold down button Joystick for X & Y stage movement Page 1 of 8

F Set the microscope into viewing mode: Filter Turn Camera dial: turn to Camera dial Filter wheel: set to A F Use the illumination control menu in the software to select your channel: Click the magnification drop down menu: Select your channel from this menu. Click the channel dropdown menu: Use this button to open and close the fluorescence light shutter: Page 2 of 8

F Focus on your sample and center your region of interest using the following controls: Coarse Focus Fine Focus Do not use! Do not use! Take care not to use the focus knobs with X s. F Check all of your fluorophores in your specimen. You need to have an idea of what to expect before you start your scan. F Close the reflected light shutter to prevent photobleaching of your sample. Page 3 of 8

F Take note of the fluorescence light path: A. Fluorescence imaging light source B. Direction through microscope C. Filter D. Lens E. Stage and specimen F. Lens G. Eyepiece/Camera Dial F Take note of the transmitted light path: H. Transmitted light imaging light source I. Direction through microscope J. Condenser K. Stage and Specimen L. Lens M. Filter N. Eyepiece/Camera Dial Page 4 of 8

4) Your first image F Set the microscope into camera mode: Camera dial: turn to Filter wheel Camera dial Set the filter wheel to the position that best matches your experiment: B. DAPI, GFP, TxRed, Trans C. CFP, YFP D. GFP, TxRed, Cy5 F Use the Multi Dimensional Acquisition Menu: Page 5 of 8

1. Click the tab within the window. a. Select you data folder in the Select Directory b. Create a base name 2. Click to set the number of wavelengths; set each wavelength illumination Page 6 of 8

F Use the Acquire window to acquire your images: Make sure the gain is above 1; you can use a recommended starting point of 3 1. Select a channel from 2. Click to view the image. 3. Click to calculate an exposure time or calculate your own exposure time; note remember to check in the Display tab to see the full range of intensity. a. Red pixels = saturation; Blue green pixels= black b. Use the histogram to help you find the best exposure: 4. Click after calculating the exposure. Page 7 of 8

Repeat the above steps for each channel. 5) Returning to the microscope To return to the microscope to find another field, and set the camera dial and filter wheel for viewing. Focus and center another region of interest. You also can perform the following operations after returning to the microscope: Using the oil immersion lens If you need to switch to the 60x oil immersion lens, first use the course focus to drop the lenses. Apply one drop of oil to the center of the lens. Carefully raise the lenses and stop when you see oil contact between the lens and slide. Focus & center your specimen. Please remember to use the fine focus control! 6) Multichannel Imaging 7) System Shutdown Back up all your data. If you used the 60x oil lens, please clean all the lenses. Check the microscope calendar to see when the next user has an appointment. If the user comes within 2 hours, log off your account. Otherwise, follow the shutdown poster steps. Page 8 of 8