DTM Distributed Transmitter Monitor

Similar documents
DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor

Electronic, Digital and Mechanical Vibration Switches

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

VS102 Electronic Vibration Switch

Proximity Transducers, Seismic Sensors and Accessories

Proximity Transducers, Seismic Sensors and Accessories

TR Series Vibration Transmitter. User Manual. Installation, operation, maintenance

Vibration Switches viib

DM200 Dual-Channel A/V/D Vibration Monitor

Proximity Transducers, Seismic Sensors and Accessories

MGate MB3170/MB3270 Quick Installation Guide

LAUREL ELECTRONICS, INC.

Vibration Switches. kmo turbo GmbH Friedrichstr Friedrichshafen Germany

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

3500/22M Transient Data Interface Module

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Features and Benefits. Certifications

Features and Benefits. Certifications

Product Description Page. Remote user interface and communications device 409

gigabit industrial ethernet user manual Models , ,

LCp-100 Weight Indicator/Transmitter

PT2060 Monitor. kmo turbo GmbH Friedrichstr Friedrichshafen Germany

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

Features and Benefits. Certifications

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Serial/Ethernet Converter

MGate 4101-MB-PBS Series

Proximity Transducers, Seismic Sensors and Accessories

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Stride Industrial Ethernet Switches

8mm, 5mm Proximity Probe TM0180 and TM0105 Systems

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

4TX + 1MMFX Unmanaged Ethernet Switch

iologik E1200H Series

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide

Features and Benefits. Certifications

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

MGate 5102-PBM-PN Series

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

MGate 5111 Quick Installation Guide

MGate 5105-MB-EIP Series

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Industrial Serial Device Server

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

3500/32M 4-Channel Relay Module

Neon pr. ph/ ORP measurement. Applications. Description

Features and Benefits. SNMP MIB-II for network management. Certifications

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

General Specifications

PTU300 Combined Pressure, Humidity and Temperature Transmitter

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

LAUREL ELECTRONICS, INC.

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

3500/22M Transient Data Interface

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

TM258LD42DT4L compact base M I/O - 24 V DC

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax:

3500/23E Transient Data Interface

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

MGate 5105-MB-EIP Quick Installation Guide

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM258LF42DT compact base M I/O - 24 V DC - CANopen

Industrial Media Converters

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Multifunction Transducer MT440

microblox I/O Modules w/ Bluetooth Wireless Technology Introduction to the microblox Module Family

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

4 Port Industrial RS-232 / 422 / 485 Serial to IP Ethernet Device Server - PoE-Powered - 2x 10/100Mbps Ports

YTM Series Digital-Transmitter-Monitor

Multi-Point Gas Detection and Control System

3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring

CPU module for zone 2 Series 9442/35

Level-Lance Model 5400A

Intrinsically Safe Temperature Concentrator System

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

Multi-Point Gas Detection and Control System

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

PCM360. Plant Condition Management System. ProvibTech, Inc Brooklet Drive, Suite 300, Houston, Texas 77099, USA

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

Technical Datasheet #TDAXTC20 Thermocouple Scanner 20 Thermocouple Channels CAN, SAE J1939 with Electronic Assistant P/N: AXTC20 Description:

TM241CE40R controller M IO relay Ethernet

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

FSM-510G Series Ethernet Management Switch Quick Start Guide

UNIVERSAL CURRENT CONVERTER

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4

Proximity Vibration / Position / Phase Reference Transmitters

/8 DIN Universal Process Indicator

TM258LD42DT4L compact base M I/O - 24 V DC

Transcription:

Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration software, the 96 truly provides a distributed vibration system. The Modbus interface enables users to remotely monitor, configure, and calibrate the s. 96 Features Direct Modbus RTU interface Optically isolated RS485, RS422, and RS232 communications Communicate with the using your computers RS232 connection Provides galvanic isolation between PC and Physical Dimension: Height: below. Weight: 75mm (2.95 ) see figure 0.7lb (0.3kg). POWER TX RX Rail Mounting Specifications Electrical Power Supply: 22-30VDC, 150mA Galvanic isolation POWER TX RX 96 Modbus: Modbus RTU RS485 and RS232 Galvanically Isolated Modbus TCP RJ45 Ethernet connection Galvanically Isolated Plate Mounting Environmental Temperature: Operation: -40 ~ +85. Storage: -50 ~ +0. Humidity: 90% non-condensing. Case: Aluminum sales@pvtvm.com www.pvtvm.com 35

R R Distributed Transmitter Monitor Certification CE certified with EMI compliance CSA: Class I, Div. 2,Grps A,B,C&D,T4 ATEX: II 3 G Ex na II T4 **TR CU: 2Ex na IIT4 X ТС RU C- US.ГБ05.В.00476 NANIO CCVE Hazardous area Marking: 6 5 4 3 2 1 12 11 9 8 7 C US 13 14 15 16 17 18 D+/485-A D-/485-B RX-/422 RX+/422 TX-/422 TX+/422 19 21 22 23 24 24V(+)(1) GND 24V(+)(2) COM TX/232 RX/232 Ordering Information 96-AX-BX-SX interface module with RS485 and RS232. AX: Output A0*: Modbus RS485, RS232, RS422 BX: Mounting B0*: DIN rail mounting B1: Plate mounting SX: Approvals S0*: CE S1: CE certified with EMI compliance CSA: Class I, Div. 2,Grps A,B,C&D,T4 ATEX: II 3 G Ex na II T4 TR CU: 2Ex na II T4 X ТС RU C- US.ГБ05.В.00476 NANIO CCVE * Denotes factory default. ** TR CU certificate is pending Optional Accessories ATEX Standards : EN 60079-0 EN 60079-15 Special condition in hazardous area: The ambient temperature range is: -40 Ta 70 s must be placed inside an enclosure that is in accordance with EN 60079-15:05. Provisions must be made externally to prevent the rated voltage from being exceeded by transient disturbances of more than 40 %. TM900A Din Rail Mounted Power Supply. It converts 0-240VAC into 24VDC and is capable of powering up to five modules. sales@pvtvm.com www.pvtvm.com 36

Distributed Transmitter Monitor Installation field-wiring diagram 96 System Installation //30 //30 //30 BUS3( +) BUS3 (-) BUS2( +) D+485-A D-/485-B RX-/422 BUS2 (-) RX+/422 TX-/422 BUS1( +) TX+/422 BUS1 (-) //30 //30 //30 BUS4( +) BUS4 (-) BUS5( +) BUS5 (-) BUS6( +) BUS6 (-) POWER The 96 has 6 connections. To wire additional modules the communications should be wired in parallel. TX RX PL C DCS Only one connection ( RS422, RS485 or RS232) can be used at one time 24V+(1) GND Power Supply 1 24V+(2) Power Supply 2 24V+(1) GND 24V+(2) COM TX/232 RX/232 sales@pvtvm.com www.pvtvm.com 37

Distributed Transmitter Monitor -CFG Configuration and Calibration Software -CFG is the configuration and calibration software used to configure all modules. -CFG works with Windows XP or Windows 00 operating system. -CFG can be connected to the modules with the interface of a RS485-USB cable kit. -CFG combined with the 96 allows the user to remotely interface with 32 s networked together in the field. -CFG Features Order Information Configuration Calibration -CFG-K configuration and calibration software kit includes: Specifications Module Configuration: Module type selection Modbus ID address, Range Communication baud rate Auto manual search of communication port English or metric selection Password and security Operation Configuration: Sensor and sensitivity selection Measurement unit selection Full-scale Dual-alarm set-points, time delay, latching Relay energized/de-energized. Relay programmed to Alert or OK OK set-points Maintenance Calibration: ZERO calibration, SPAN calibration Probe linearization calibration Real-time overall and status display Record of overall and status Configuration parameter save as file -CFG configuration and calibration software CD RS485-USB converter with cable User manual -CFG configuration and calibration software includes: -CFG configuration and calibration software CD User manual -CAL The field calibration kit with probe calibration capability with any 5mm, 8mm and 11mm probe system. The kit includes: -CFG configuration and calibration software CD RS485-USB converter with cable TM0540 proximity probe field calibration kit User manual Optional Accessories RS485-USB: RS485 to USB converter with cable RS232-USB: RS232 to USB converter with cable 96: Isolated communication module TM0540: Proximity probe field calibration kit sales@pvtvm.com www.pvtvm.com 38

Distributed Transmitter Monitor networking and on-line condition monitoring Ethernet DAQ Server 96 96 96 reference reference reference 0 0 0 Machine Train1 Machine Train2 Machine TrainN sales@pvtvm.com www.pvtvm.com 41

Distributed Transmitter Monitor Ethernet DB Server SWITCH TCP CONVERTER Reference TCP CONVERTER Reference TCP CONVERTER Reference 0 0 0 Machine Train 1 Machine Train 2 Machine Train N sales@pvtvm.com www.pvtvm.com 42