Sfera Keypad Module. Installer manual 07/12-01 PC

Similar documents
05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual

Sfera Display Module. Installer manual 05/16-01 PC

Vandal-resistant entrance panel. Installer manual RA00054AA_I_EN01PC-12W16

Vandal-resistant entrance panel

Video Display Eteris. Installation manual 01GF-28W10

TiSferaDesign. Instructions for use.

L4561N Stereo Control. Installation manual.

F Basic gateway. Installation Manual.

F Installation manual.

2 WIRE video door entry system

TiMonoblocEntrancePanel

D45 System. Digital colour entrance panel with addresses list

item Instruction sheet PART. T6101D - 05/05-01 PC

Temperature control unit

D45 System. 3.5 Colour handsfree internal unit. Front view

AS Keypad User Manual

TiSecurityPolyx user manual

2 WIRE Video Door Entry system

Front view. Internal view. Legend

RFID/Digital Access Control Keypad

BMSO1001. Virtual Configurator. User guide 01/10-01 PC

HOMETOUCH HOMETOUCH flush mounted box Additional power supply. Rear view

F450. Gateway OpenBacnet. Software Manual.

CLASSE 300 THE CONNECTED VIDEO INTERNAL UNIT

DG-800 Stand-Alone Proximity Reader Instruction Manual

Video Display Eteris User guide 01GF-28W10

MH201. Software Manual.

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

D45 System. 7 touch screen handsfree internal unit. Front & side views

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

TiLocalDisplayNew. Software Manual 07/12-01 PC

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Pulse PRO. High security lock for safes USER INSTRUCTIONS

VIDEO DOOR ENTRY SYSTEM OFFER

3001D Smart Safe Manual

User s manual Primor 1000 / 3000 / 3010/ Level 5

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM

Digital Keypad Introduction

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

D45. High performance door entry system CATALOGUE A Group Brand

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

CLASS I CLASS I AUTONOMOUS PROXIMITY READER INSTALLATION MANUAL AUTONOMOUS PROXIMITY READER INSTALLATION MANUAL ENGLISH ENGLISH

D1265. Installation Guide. Touchscreen Keypad

EN TECHNICAL MANUAL. Audio module Art and Art. 1622L

212iL Rev. 1.1

BIO-PRO Standalone / Weigand fingerprint reader

8-wire Digital. Audio/Video Intercom Systems. Catalogue

Updating Reader Firmware

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

3001D Smart Safe Manual

User Manual. PCKeypad Wireless Keypad

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Lens of the access control (Optional) Camera: pick up the image. PP NN TS : configurator. ISP: entrance panel software upgrade connector

User s manual Primor 1000 / 3000 / 3010 / Level 15

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

KP2000E/EM Series Style Keypad

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

180 Series Keypad. Handbook. Revision 2.1

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

SK-1011-SDQ Access Control Keypad. Manual

YourBell INEXPENSIVE, RELIABLE USB PRODUCTS.

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

DYB2200 INEXPENSIVE, RELIABLE USB PRODUCTS.

VIDEO DOOR ENTRY SYSTEM OFFER

NX-588E USB Flash Programmer Instructions v1.1

EL-ST100 KEYPAD CONTROLLER

EN TECHNICAL MANUAL. ViP Mini hands-free monitor art. 6721W. Passion.Technology.Design.

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

K44 Code lock. Technical manual

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

YourBell INEXPENSIVE, RELIABLE USB PRODUCTS. 1

Keypad Lock. Operation and Service Manual. Order parts online

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. backlit touch keypad

M A C 3 Wind Speed Alarm & Controller

SK-1131-SPQ Access Control Keypad with Proximity Card Reader. Manual

39E Electronic Combination Lock SETUP INSTRUCTIONS

2000 Series e/em Style Keypad Installation and Programming Manual

Single Door Standalone Access Control User Manual

EN TECHNICAL MANUAL. Handsfree door entry phone Mini 6750W, Mini 6751W. Passion.Technology.Design.

Proximity Card and Pin Reader Installation Manual

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Tel Fax: Toll free:

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

EN TECHNICAL MANUAL. Door-entry phone art. 2738W

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Outdoor Stand-Alone Weatherproof Keypads

EAR 1000 / ADRA 1000 / Installation and Programming Manual

CATALOGUE D45 High performance door entry system

Setup Instructions. LA GARD ComboGard Pro 39E Electronic Lock

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

MAC3 Wind Speed Alarm & Controller. Installation Instructions

Transcription:

353000 Sfera Keypad Module Installer manual 07/12-01 PC

2

Contents Sfera Keypad Module Installer manual 1 Introduction 4 1.1 Warnings and recommendations 4 2 Description 5 2.1 Main functions 5 2.2 Front view 6 2.3 Back view 7 3 Configuration 8 3.1 Master code 8 3.1.1 New master code 8 3.1.2 Deleting master codes 10 3.2 Passepartout code 11 3.2.1 New passepartout code 11 3.2.2 Deleting passepartout codes 13 3.2.3 Replacing the passepartout code 14 3.3 Resident code 16 3.3.1 New resident code 16 3.3.2 Deleting the resident code 19 3.3.3 Replacing the resident code 20 4 Advanced configuration 22 4.1 Connection to the PC 22 4.2 Door lock control 23 4.3 Reset 24 5 Appendix 25 5.1 Technical data 25 3

1.1 Warnings and recommendations 1 Introduction Before proceeding with the installation we recommend that you read the content of this manual very carefully. The warranty will automatically become void in case of negligence, improper use, and tampering by unauthorised personnel. The Sfera Keypad Module must only be used with BTicino 2 wire digital systems. Front covers that may be used with the Sfera BTicino Keypad Module: Front cover 353005 Front cover 353001/02/03 4

2 Description 2.1 Main functions Sfera Keypad Module The BTicino Sfera Keypad Module can be used by residents to open a door lock using previously stored numerical codes. The device consists of a backlit pushbutton panel with 12 keys and luminous indicators, for controlling that the code has been entered correctly. Installer manual If installing the Sfera Keypad Module in conjunction with the display module (352500) refer to its manual. Programming can be performed in two ways: - using the TiSferaDesign software supplied with the product (chapter 4); - following specific procedures, performed directly on the keypad (chapter 3). In order to configure the master codes remove the front cover and press the programming pushbutton indicated in the legend (chapter 2.2). The secret code must consist of minimum 4 and maximum 9 digits. Three different types of codes may be programmed: - MASTER Code providing access to the programming of other codes. It can only be used for programming, not for access.. - Passepartout It can be used to open the door lock the entrance panel is associated to. It s not linked with any apartments. It can only be used for access, not for programming. - RESIDENT It can be used to open the door lock the entrance panel is associated to. It s linked to an apartment of the system. It can only be used for access, not for programming. 5

2 Description 2.2 Front view 1 2 3 4 5 1 - Digital keypad + key illumination LED. key for the selection of the door lock release code. key for the replacement of the codes. 2 - Mini-USB programming connector. 3 - Programming pushbutton. 4 - Red LED on steady: access denied, or programming error. 5 - Green LED on steady: access granted, or programming successful. 6

2.3 Back view Sfera Keypad Module Installer manual 6 5 4 3 2 1 1 - Connection of door lock pushbutton (CP-P1) and tamper (CP-P2 future application). 2 - Local relay contacts. 3 - Connection to the BUS. 4 - Connector for the connection to subsequent modules. 5 - Connector for the connection to previous modules. 6 - Configurator sockets. 7

3 Configuration 3.1 Master code For safety reasons, the system gives the installer the possibility of programming a MASTER code. This can be used to access the programming of the other codes (passepartout and resident codes). To access programming mode, a master code must be assigned to the device.; up to 20 master codes may be saved. The keypad module will indicate that the code has been accepted or deleted by means of audible signals and the switching on of the green LED. If an unrecognised code is entered, programming will stop. This interruption is confirmed by a long beep, and the red LED coming on. 3.1.1 New master code 1 Press the programming pushbutton until the green LED flashes and a confirmation beep is heard. 2 Press the key. 3 Enter the code (4 4 Press the key. to 9 digits). A short beep confirms the programming of the new master code 8

Sfera Keypad Module Installer manual 5 Re-enter the code to confirm. OK NO Correct code: green LED on and short beep. Wrong code: red LED on and long beep If the procedure has been successful, the green LED stays on for approximately 1 second before starting to flash again. Enter another code, or finish. 6 Press the programming pushbutton, or wait 30 seconds to exit the procedure. A short beep and the LEDs switching off indicate that the programming procedure has been terminated. The Sfera Keypad Module is now ready for normal operation. During programming, some rules must be followed: - keys must be pressed consecutively (maximum 2 seconds between pressures); - the programming sequence must be started within 30 seconds from the moment the programming pushbutton has been pressed and must be completed in one stage. 9

3 Configuration 3.1.2 Deleting master codes 1 Press and hold down the programming pushbutton; the green LED flashes. 2 Continue holding down the pushbutton; the device emits 1 beep per second, and a long beep after ten seconds 3 The red LED flashes and then switches off to confirm that the deletion has been performed. - The procedure will delete all the stored Master codes. - During the procedure press the programming pushbutton. - To stop the deletion procedure release the programming pushbutton. - To only delete a specific code use the TiSferaDesign software. 10

3.2 Passepartout code Sfera Keypad Module Installer manual To access the programming of a Passepartout code, a master code is necessary. up to 20 passepartout codes may be saved. The keypad module will indicate that the code has been accepted or deleted by means of audible signals and the switching on of the green LED. If an unrecognised code is entered, programming will stop. This interruption is confirmed by a long beep, and the red LED coming on. 3.2.1 New passepartout code 1 Enter the master code. The device emits a beep, and the green LED starts flashing. The programming procedure starts. 2 Press the key. 3 Enter the 4 Press the key; passepartout code (4 to 9 digits). a short beep confirms the programming of the new passepartout code. 11

3 Configuration 5 Re-enter the code to confirm. OK NO Correct code: green LED on and short beep. Wrong code: Red LED on and long beep. If the procedure has been successful the green LED stays on for approximately 1 second, before starting to flash again. Enter another code, or finish. 6 Press the pushbutton, or wait 30 seconds to exit the procedure. A short beep and the LEDs switching off indicate that the programming procedure has been terminated. The Sfera Keypad Module is now ready for normal operation. During programming, some rules must be followed: - keys must be pressed consecutively (maximum 2 seconds between pressures); - the programming sequence must be started within 30 seconds from the moment the programming pushbutton has been pressed and must be completed in one stage. 12

Sfera Keypad Module Installer manual 3.2.2 Deleting passepartout codes 1 Enter the master codes three times in succession. Three times 2 The device emits a long confirmation beep. 3 The red LED flashes and then switches off to confirm that the deletion has been performed. - The procedure will delete all the stored Passepartout codes. - To only delete a specific code use the TiSferaDesign software. 13

3 Configuration 3.2.3 Replacing the passepartout code 1 Press the key until the green LED starts flashing. 2 The green LED flashes. 3 Enter the passepartout code. 4 Press the key. 5 Enter the new code. 6 Press the key. A short beep confirms the programming of the new passepartout code. 14

Sfera Keypad Module Installer manual 7 Re-enter the code to confirm. 8 The device emits a long confirmation beep. 9 If the procedure has been successful the green LED stays on for approximately 1 second before switching off. During programming, some rules must be followed: - keys must be pressed consecutively (maximum 2 seconds between pressures); - the programming sequence must be started within 30 seconds from the moment the programming pushbutton has been pressed and must be completed in one stage. 15

3 Configuration 3.3 Resident code To access the programming of a RESIDENT code a master code is necessary. Up to 4000 codes may be saved, one for each apartment. The keypad module will indicate that the code has been accepted or deleted by means of audible signals and the switching on of the green LED. If an unrecognised code is entered, programming will stop. This interruption is confirmed by a long beep, and the red LED coming on. If installing the Sfera Keypad Module in conjunction with the display module (352500) refer to its manual. 3.3.1 New resident code 1 Enter the master code. The device emits a beep, and the green LED starts flashing. The programming procedure starts. Apartment 1 Apartment 2 Apartment 3 2 Use the pushbutton module (352041,42,43) to select the apartment the resident code must be associated to. Apartment 4 352041/42/43 16

Sfera Keypad Module Installer manual 3 Press the key. 4 Enter the resident code (4 to 9 digits). 5 Press the key; a short beep confirms the programming of the new resident code. 6 Re-enter the code to confirm. OK NO Correct code: green LED on and short beep. Wrong code: red LED on and long beep. 17

3 Configuration If the procedure has been successful the green LED stays on for approximately 1 second before switching off. A short beep and the LEDs switching off indicate that the programming procedure has been terminated. The Sfera Keypad Module is now ready for normal operation. During programming, some rules must be followed: - keys must be pressed consecutively (maximum 2 seconds between pressures); - the programming sequence must be started within 30 seconds from the moment the programming pushbutton has been pressed and must be completed in one stage. 18

Sfera Keypad Module Installer manual 3.3.2 Deleting the resident code 1 Enter the master code. The device emits a beep, and the green LED starts flashing. The programming procedure starts. Apartment 1 Apartment 2 2 Use the pushbutton module (352041,42,43) to select the apartment for which the resident code must be deleted. Apartment 3 Apartment 4 352041/42/43 3 Re-enter the master code. 4 The device emits a long confirmation beep. 5 The red LED flashes and then switches off to confirm that the deletion has been performed. 19

3 Configuration 3.3.3 Replacing the resident code 1 Press the key until the green LED starts flashing 2 The green LED flashes. 3 Enter the resident code. 4 Press the key. 5 Enter the new code. 6 Press the key; a short beep confirms the programming of the new resident code. 20

Sfera Keypad Module Installer manual 7 Re-enter the code to confirm. 8 The device emits a long confirmation beep. 9 If the procedure has been successful the green LED stays on for approximately 1 second before switching off. During programming, some rules must be followed: - keys must be pressed consecutively (maximum 2 seconds between pressures); - the programming sequence must be started within 30 seconds from the moment the programming pushbutton has been pressed and must be completed in one stage. 21

4.1 Connection to the PC 4 Advanced configuration To transfer the configuration performed using the TiSferaDesign software, or to update the firmware, connect the Sfera Keypad Module to the PC using a USB-miniUSB cable. mini USB - USB BUS When updating the software the device must be powered. The Sfera Keypad Module connected using a USB cable is recognised by the PC as a virtual port (VIR- TUAL COM). 22

4.2 Door lock control Sfera Keypad Module Installer manual The TiSferaDesign software may be used to set the maximum number of digits to use when composing the code (4 to 9 digits). If the length of the code, selected during manual programming, is less than the length set by the software, in order to open the door lock the following must be entered: or to open the door lock using a code with the same length as the maximum length set enter: 23

4.3 Reset 4 Advanced configuration It is also possible to reset the Sfera Keypad Module and delete all the previously set codes; this will bring the module back to all the default settings. OFF ON 1 Disconnect the power supply (BUS), press and hold down the programming pushbutton and reconnect the power supply. 2 Holding down the pushbutton until an extended beep is heard. 3 The red LED comes on for 4 seconds and then switches back off. In entrance panels with keypad and speaker module, wait one minute after the reset procedure before starting the programming procedure again. 24

5 Appendix 5.1 Technical data Sfera Keypad Module Installer manual Power supply from BUS 18 27 Vdc 10 Ma (Stand-by with LEDs off) Absorption 20 Ma (Stand-by with LEDs on) 45Ma (max in operation) 8 A, 30 Vdc Load of local relay contacts 8 A, 30 Vac cosφ = 1 3,5 A, 30 Vac cosφ = 0,4 Operating temperature (-25) (+70) C Technical After-Sales Service BTicino only accepts responsibility for perfect device operation if it is installed to the state of the art respecting the indications of the product installation manual. www.bticino.com 25

26

Sfera Keypad Module Installer manual 27

BTicino SpA Via Messina, 38 20154 Milano - Italy www.bticino.com BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality, the changes brought to the same.