Master room unit for RRV controllers

Similar documents
Temperature controller Ducted systems

Temperature controller Multi-zone ducted systems

Temperature Controller

Temperature controller for multi-zone ducted systems

Room Temperature Controller

Semi flush-mounted room temperature controllers with LCD

Room unit with PPS2 interface

Room Temperature Controllers

Semi flush-mounted room temperature controllers with LCD

Semi Flush-mount Room Temperature Controllers with LCD

Room unit with PPS2 interface

Room Temperature Controller

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Room unit with PPS2 interface

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Room unit with PPS2 interface

7-day room temperature controller

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

7-day room temperature controller

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Universal Controller

Weekday / weekend room temperature controller

Temperature Controller (Heat Pumps)

Heating Circuit Controller

Non-communicating room controllers

Room thermostat with KNX communications For VAV heating and cooling systems

Weekday / weekend room temperature controller

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Heating Circuit Controller

Immersion Temperature Sensors

Product and Application Description

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room thermostats with KNX communications

Non-communicating room controllers

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room thermostats with KNX communications

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

Electrical Actuators

24-hour room temperature controller

Compact Universal Controllers

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

RDF Series Room Temperature Controllers

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

ERF910. RF Repeater. Synco living

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

STRA-17 Room controller. Installation and maintenance manual. Content

Communicative controller for VAV systems

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Pre-programmed room controller with display and communication

OZW V3.0. Web server. For Synco TM, Synco TM living

Extension module for lighting control

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Compact universal controllers

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

Electrical Actuators

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Electrical Actuators

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

FCU-4 FAN COIL CONTROLLER

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Wall-mounted room thermostats with LCD

Status display unit with P-bus connection

HLS34 Modbus FCU/VAV Controllers installation instructions

7-day room temperature controller

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

FCU-MULTI Modbus Fan Coil Unit Controller

Rotary version, three-position control

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

FCU-4 FAN COIL CONTROLLER

TC-8900 Controller Units with PM-8900 Power Modules

Field selectable application type and room module series, via dip-switches on controller

PXR11 PXR12. System controllers DESIGO PX

Room controller STRA-17

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

M-Bus Central Unit. Use

VAV modular controller

Power supply module, bus connection module

Freely configurable flush-mounted room operator unit for KNX PL-Link

Transponder card reader

AIAS. Technical description

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Technical data sheet

VAV compact controller KNX / PL-Link

OP10. Pre-programmed, configurable controller for simple applications

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Transcription:

2 722 Master room unit for RRV controllers 2 wire bus connection QAX850 Multifunctional, digital room unit for installer and end-user interface with RRV controllers. Use Use Application Room unit in combination with an RRV controller for HVAC plants in: Residential apartments Residential single house Autonomous light commercial applications For use with RRV controllers in air based plants including heating, cooling and ventilation (HVAC) equipment. Suitable for Standard, Duo-zone, Duo-switch and Multizone applications. Functions Primary functions Operator functions Remote control and monitoring of an RRV controller Parameter adjustments by installer Room temperature measurement Time clock operation Comfort temperature setpoint adjustment Energy saving temperature setpoints adjustment Auto timer selection Fan speed selection Zone selection and settings (only for RRV controllers with zone outputs) Display of operating mode, temperature, time, fan speed and zone values. AP1N2722en Siemens Building Technologies 26.01.2005 HVAC Products

Type summary ASN Type reference Compatible with QAX850 Room unit RRV851, RRV852, RRV856, QAW850 Note: Not usable with Desigo RX range of controllers. Mechanical design Type of unit The QAX850 is the installer/oem/end-user master MMI for RRV controllers. The unit consists of the following components: Room unit with integrated electronics and operating elements Internal temperature sensor Base for wall mounting with the connection terminals Operator interface buttons (high use) Operator interface buttons behind door (low use) Operating elements 1 2 5 3 6 7 8 9 10 11 Legend 1 LED for heat/cool output status 2 LCD display with EL backlight for control and monitoring of modes, setpoints, zone conditions etc 3 Operating mode selection Comfort, energy saving and auto timer (RRV852 Day/Night zone selection for Duo-zone application) Temporary setpoint and value increase/decrease 5 System off and fan speed control 6 Heat, cool, heat/cool changeover and ventilation only selection 7 Time and weekday setting 8 Auto timer schedule setting 9 Zone output selection (RRV856 and RRV852 for Duo-switch application) 10 Permanent comfort and energy saving setpoints (Day/Night/Both setpoints for RRV852 Duo-zone application) 11 Button for confirming values and scrolling through parameter sets 2/7

LCD display 1 2 3 6 7 5 1 8 9 13 12 10 11 Legend 1 Day indication 2 Actual temperature 3 Fahrenheit/Celsius Zone indication (RRV856 and RRV852 for Duo-switch application) 5 AM/PM indication 6 Time display 7 System off 8 Comfort mode (Day zone in Duo-zone application) 9 Energy saving mode (Night zone in Duo-zone application) 10 Auto timer mode 11 Heating mode 12 Cooling mode 13 Fan speed indication (low, medium and high) 1 Auto fan mode Commissioning notes Response on start-up Sensor calibration Commissioning When powering up, the QAX850 will display all LCD icons for approximately 3 seconds and then the software version number for another 3 seconds. It will then revert to normal display. The time segments will be blinking if time needs to be set. Set time as per operation instructions. There will be a delay before operation commences due to polling of all values. Generally there is no need to calibrate sensor; however the displayed room temperature on the LCD can be calibrated if there is any discrepancy from the actual temperature measured with a certified thermometer. Calibration function can be accessed by pressing the and buttons simultaneously for 5 seconds. Displayed value can then be adjusted via the same buttons in 0.1K steps. Range is +/- 3K. Initial application set-up of RRV controller to match the connected HVAC equipment is made by the selection of dip switch positions. Dip switches are located on the top of the RRV controller. Further settings can be made via the QAX850 by modifying parameters as per list below. Default values are dependant on application selected and RRV controller model. Refer to installation/commissioning guide for set-up details and application sheets for default parameter values. To access parameters press the and buttons simultaneously for 3 seconds, then within 2 seconds press the button for 3 seconds and release. Parameters cannot be accessed if system is in off mode. 3/7

Set-up parameters No Parameter Range P00 Temperature scale C/ F P01 Frost protection limit in OFF mode Off/5 8 C P02 Over-temperature limit in OFF mode Off/30 35 C P03 Min. OFF time delay 0...600s P0 Min. ON time delay 0 600s P05 Dead band between cool and heat OFF points 0.5 6K P06 RV ON in heat or cool mode Heat/Cool P07 Fan run ON after heat output turns Off 0 300s P08 Fan run ON after cool output turns Off 0 300s P09 FCU flush pipe time 120 600s P10 Zone Heat / Cool Inhibit Heat/Cool/No P11 Water temp. heat mode changeover 22...32 C P12 Water temp. cool mode changeover 10...21 C P13 Fan auto-speed high range H:80...100% P1 Fan auto-speed medium range M:30 75% P15 Fan auto-speed low range L:1...15% P16 Window contact NO/NC P17 2-p or 3-p control selection 2-p/3-p P18 P-band in heat mode /Switching differential 0.5 10K P19 P-band in cool mode /Switching differential 0.5 10K P20 Integration time 0...60.0 min in 0.5 min steps P21 3-p valve actuator running time 50 300s P22 Zone capacity weight None Small Medium Large P23 Ventilation in dead zone Off, H/C, C only Internal sensor QAX850 internal sensor can be replaced by connecting an external NTC resistor sensor (QAA32 or QAH11) to the RRV controller B1 input. In this case the QAX850 automatically recognizes and displays the external sensor value. Mounting and installation notes The QAX850 should be mounted in a location where the air temperature can be measured as accurately as possible without getting adversely affected by direct solar radiation or other heating or cooling sources. There is no need to consider air temperature conditions if external sensor is connected to the RRV controller. In this case the QAX850 would serve as a master control unit only. /7

Mounting height is about 1.5 m above the floor. QAX850 must not be located in the direct path of air conditioning air flow. The unit can be fitted to a recessed conduit box. The specified ambient conditions must be complied with. Only authorized staff may disconnect the QAX850 unit from base plate. Do not mount in recesses, shelves, behind curtains or doors. Refer to mounting instructions included in packaging box. When mounting the unit, fix the base-plate first and then make the electrical connections. To avoid any damage during construction works only install QAX850 unit when all construction works have been completed. The QAX850 must be mounted on a flat surface and in compliance with local regulations. Local installation regulations must be observed. STOP Note! The room unit is not protected against connection to AC 230 V. Technical data Interfaces Protection Environmental conditions Standards HCC bus Baud rate Permissible cable length Cable type Proprietary 9.6 kbit/s Max. 60m where A 0.5mm² Max. 100m where A 1mm² 2-wire standard installation cable (unshielded) Note: Twisted pair (unshielded) is recommended for enhanced immunity to external electromagnetic interference, for example, in the vicinity of radio transmitters or frequency inverters Safety class III to EN 60730 (when mounted correctly) Degree of protection IP 30 to EN 60529 Operation IEC 721-3-3 class 3K 5 Temperature 0 50 C Humidity < 85 % r.h. (non condensing) Transport IEC 721-3-2 class 2K 3 Temperature -25 60 C Humidity < 95 % r.h. (non condensing) Storage IEC 721-3-1 class 1K 3 Temperature -25 60 C Humidity < 95 % r.h. (non condensing) -conformity EMC directive 89/336/EEC Immunity and Emissions EN 60730-1, EN 50081-1, EN 61000-6-2 Low-voltage directive 73/23/EEC Electrical safety EN 60730-1, EN 60730-2-9 N7 conformity to Room temperature measurement Australian EMC Framework Radio communication act 1992 Radio Interference Emission AS/NZS 251.1 Standard Measuring range 0 9 C Setpoint range 5 35 C Maximum power 2VA Accuracy at 20 C ± 0.5K max. 5/7

HB+ HB+ HB- HB- Other features Temperature calibration range ± 3.0K max in step of 0.1K. Room temperature 0.5K display resolution Software class A to EN 60 730 Weight Approx. 0.1 Kg Notes Product liability The products may only be used in building services plant and applications as described above. When using the products, all requirements specified under Technical data must be observed. The local regulations for electrical installation must be complied with. Connection diagram N1 N2 N1 N2 HB+ HB- RRV... controller QAX850 master room unit Communication bus 6/7

Dimensions 119 3035M01 96 23,8 28 28 11,8 30 28 112,3 35 28 26 30 89,5 3031M02 Dimensions in mm 200Siemens 2005 Building Technologies HVAC Products 7/7