Ultrasonic Transmitter SONAPHONE T Version 2.0

Similar documents
Flow Sensor SONOFLOW CO.55

SONOFLOW Monitor Short Instructions. For SONOFLOW Sensors of the Series CO.55 V2.0

Ultrasonic Leak Detector and Leakage Tester SONAPHONE M

SHORT INSTRUCTIONS ULTRASONIC TESTING DEVICE

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Ultrasonic Testing Device for Preventive Maintenance

Operation Manual Locator Wöhler L 200

Thank you for your purchase USER MANUAL

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Dialock DT Lite. Operating instructions...2. Operating instructions

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

PX Series Balances. Quick Start Guide. Please download the user manual from

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

USER MANUAL Video Particle Counter with built in Camera Model VPC300

HI HI N HI HI

Operating Instructions for Orderman Sol & Sol+

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

B63/ NS MS. EtherNet/IP LINK

Variable-Speed Vortex Mixer

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

Wall-Mounted Laptop Cabinet NOR-HNA1000-SO

SPK User Manual. 900MHz Wireless Stereo Headphones INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Documentation. Mains filter AX2090-NF50. Version: Date:

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

InControl INCONTROL OVERVIEW

icore Kiosk system Installation Guide

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Ultrasonic Leak Detector and Leakage Tester SONAPHONE E

Assembly and Operating Instructions. NFC module for BDC-i440 control units

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

GMH Operating Manual for Digital Quick-Response Thermometer

NOTICES NOTICE OF INTENDED USE

User Manual Revised 1-July-2015

Classic Flanger effects pedal. user manual

Version-E Manual PR1a. Photocell. Manual. Page 1

DuoFern Multiple Wall Controller

FengMi Wemax One Laser Projection TV

HMEC 250 Headset for general aviation

i-reader User manual

HMEC Instructions for use

Assembly and Operating Instructions. M2 module for BDC-i440 control units

DC-D2212R / DC-D2212WR

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

Operation and Installation Manual

DIN T. Dh 2094

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Living. Keyfree Connected Smart Lock Manual. smart. The smarter way to protect your home

HD829THD USER MANUAL

UHF WIRELESS MICROPHONE WM-4310A WM-4310H

Operating instructions

INTRODUCTION CT87E FEATURES AND CONTROLS

VORON. Concealed micro video cameras detector. Version: March 2013 OPERATION MANUAL. TS-Market

MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL. Be sure to read this manual for safe and proper operation. Store this manual carefully after use.

Vibration Meter Instruction Manual

User manual. paper moisture meter humimeter RH5 with sword sensor

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

DECT CLIP UC-01 USER GUIDE

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

HP4 headphone amplifier. user manual

NE400 - LED MOTION LIGHT WITH VIDEO CAMERA

Model UT371/372 OPERATING MANUAL

Installation Instruction. HART Add-On Module

SPOTTER the multipurpose sensor

HI HI N HI HI

Disclaimers. Important Notice

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

DVI Extender over Fiber with EMI Shielding

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

JXHDBT1. Owner s Manual

Weatherproof IR Color Day/Night Cameras

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Troubleshooting Manual

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

testo 175 Data loggers Instruction manual

Quick Start USER GUIDE

SHUTTERBOSS VERSION II USER MANUAL

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

2CKA001473B Technical Reference Manual Movement detector/switch actuator, 1gang, wireless MSA-F

User's Guide. Digital Multimeter. Model MN42

High Definition VideoScope

Q U I C K S T A R T G U I D E

Dual channel temperature logger with display Instruction Manual

Instruction manual Wattmeter CLM1000 Home

HD 46 HME 46. Instructions for use

Greenline-Laser 3P / 5P

Temperature logger with display Instruction Manual

UP-1-1 Channel Dimmer. User manual. dimmer pack

Temperature logger with internal sensor Instruction manual

PA12 DSP active speaker. user manual

5001 Letter Opener Operators Instructions

Transcription:

Ultrasonic Transmitter SONAPHONE T Version 2.0 Operating Manual

Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Ultrasonic transmitter SONAPHONE T Version 2.0 SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Straße 2 D - 06112 Halle (Saale) Phone: +49 (0)345 133 17-0 Fax: +49 (0)345 133 17-99 E-mail: Internet: sonotec@sonotec.de www.sonotec.de 2013 SONOTEC Ultraschallsensorik Halle GmbH All rights reserved The content of this manual is the property of SONOTEC Ultraschallsensorik Halle GmbH and is protected by copyright. Duplication and distribution in any form, particularly reprinting, photographic, mechanical or electronic reproduction, or in the form of storage in data processing systems or data networks, is prohibited without the consent of the copyright holder. Version: 2 Revised: 2013-05-02

Contents 1 Notes on the operating manual... 4 1.1 General... 4 1.2 Symbols used... 4 2 Safety... 5 2.1 Safety information... 5 2.2 User qualifications... 5 3 Device description... 6 3.1 Designated use... 6 3.2 Measuring method and functioning... 6 3.3 Device construction... 6 3.4 Display and operating buttons... 7 3.5 L50 ultrasonic air transducer... 8 3.6 SONOSPHERE spherical transmitter (optional)... 8 4 Commissioning and installing... 10 4.1 Inserting the batteries... 10 4.2 Connecting the power supply unit... 10 4.3 Installing probes... 10 4.4 Uninstalling probes... 11 5 Operating the SONAPHONE T... 12 5.1 Switching the SONAPHONE T on and off... 12 5.2 Setting the sound intensity... 12 5.3 Switching on modulation... 12 5.4 Switching on the light... 12 5.5 Setting the display contrast and time... 13 6 Cleaning and care... 14 7 Maintenance and troubleshooting... 14 8 Technical data... 15

1 Notes on the operating manual 1 Notes on the operating manual 1.1 General Thank you for choosing the SONAPHONE T. This manual forms part of the SONAPHONE T and should therefore be stored in its immediate vicinity where it can be accessed by all operators at any time. It contains all the information needed to ensure proper and efficient use, along with all the instructions to ensure safe operation of the SONAPHONE T. 1.2 Symbols used Hazards or special information can be indicated in the following ways: Warning! This information warns of possible personal injury and damage to property. Caution! This information warns of possible damage to property. Note This symbol provides information or draws attention to special features. SONAPHONE T 4

2 Safety 2 Safety 2.1 Safety information The SONAPHONE T is a state of the art product that complies with all applicable safety regulations. The manufacturer has taken every possible action to guarantee safe operation. The user must ensure that safe use is not impaired. The device is factory tested and was delivered in a safe operating condition. Warning! Incorrect operation and use of the SONAPHONE T ultrasonic transmitter and its accessories can present a hazard for the user. The SONAPHONE T may only be operated with power sources in the operating voltage range specified in the technical data. Operation and storage of the SONAPHONE T outside the temperature ranges specified in the technical data is not permitted. The SONAPHONE T may not be immersed. The SONAPHONE T may only be exposed to a minimal risk of mechanical hazard. If there is visible damage, the SONAPHONE T must be taken out of operation immediately. It is not permitted to open the SONAPHONE T or accessories or to undertake repair work on them without authorisation. This may only be carried out by the manufacturer. 2.2 User qualifications Warning! The SONAPHONE T ultrasonic transmitter may only be installed and operated by users who have read and understood the entire operating manual. SONAPHONE T 5

3 Device description 3 Device description 3.1 Designated use The SONAPHONE T is a special ultrasonic transmitter and serves as an auxiliary device for ultrasonic detectors in the SONAPHONE series for leak testing. The device provides detection of seal failures in windows, doors, cabins, climatic cabinets, vehicles or containers, which have sealing surfaces or rubber profile seals. 3.2 Measuring method and functioning The SONAPHONE T transmits high-frequency signals in the ultrasonic range. If you place the ultrasonic transmitter for leak detection in a closed system, the ultrasonic signals escape via leaks in the system and can be identified there using an ultrasonic detector in the SONAPHONE series. Modulation of the signal is used in cases where it is expected that background noise will interfere with the sounds being analysed. The sound intensity can be set individually, so that both small and large leaks can be located. 3.3 Device construction 1 2 3 Figure 1: SONAPHONE T ultrasonic transmitter 4 Item number Function 1 Slot for ultrasonic probes 2 Display and operating buttons 3 Connection for power supply unit 4 Battery compartment Table 1: SONAPHONE T device elements SONAPHONE T 6

3 Device description 3.4 Display and operating buttons Description of the display elements: 1 2 3 4 Figure 2: Display 5 Function/view on the display 1 Device: On/Off button : 2 Signal type view: Modulation On ~ or Off = 3 View of the current sound intensity 4 Battery status view 5 Function of the enter key in the menu Table 2: Description of the display elements Description of the operating buttons: 1 2 3 Figure 3: Operating buttons 4 Function 1 Settings in the menu: Increase or decrease value 2 Modulation: On/Off 3 Enter key: Switch to menu or confirm value 4 Light: On/Off Table 3: Description of the operating buttons SONAPHONE T 7

3 Device description 3.5 L50 ultrasonic air transducer 1 2 3 Figure 4: L50 airborne sound probe and extension Function 1 Button for unlocking 2 Connector 3 Extension (optional) Table 4: Elements of the airborne sound probe 3.6 SONOSPHERE spherical transmitter (optional) The SONOSPHERE spherical transmitter is used to test large and contorted areas. Depending on requirements, it can be used as a semi-sphere with 7 transmitters or as a full sphere with 14 transmitters. 1 2 3 4 Figure 5: SONOSPHERE spherical transmitter Function 1 Connecting cable 2 Plug-in connector for the sphere halves 3, 4 Fixing: with suction cup, magnet or stand (without fig.) SONAPHONE T 8

3 Device description Table 5: Elements of the spherical transmitter SONAPHONE T 9

4 Commissioning and installing 4 Commissioning and installing 4.1 Inserting the batteries Caution! Make sure you install the batteries in the correct position. The device may be damaged if they are not properly fitted. The correct position for installing the batteries is shown on the device. Unscrew the battery compartment cover. Insert the batteries into the battery compartment according to the illustration on the bottom of the device. When the device is operational, the battery (1.5 V) status is shown on the display. Appropriate accumulators can also be used to operate the device. The charge status for the accumulators (1.2 V) is then shown approximately. 4.2 Connecting the power supply unit The power supply unit has no charging function. Unscrew the protective cover for the power supply connection. Connect the power supply unit. The device recognises the connection of the power supply unit even when it is operating and automatically switches over to mains power operation. 4.3 Installing probes Caution! Make sure the probe connector is in the correct position. The device and the probe may be damaged during installation. The slot for probes is provided with a notch which indicates the correct position for insertion. Install the required probe in the specified position. You must feel the connector click into place. The probe is installed and ready to use. SONAPHONE T 10

4 Commissioning and installing 4.4 Uninstalling probes Press the button to unlock the connector. Pull the probe carefully and straight to remove it from the slot. SONAPHONE T 11

5 Operating the SONAPHONE T 5 Operating the SONAPHONE T 5.1 Switching the SONAPHONE T on and off Switch the device on or off by pressing the On/Off button. The screen shows the device name and version number for a short time. The device is ready to use and during operation displays the current sound intensity. 5.2 Setting the sound intensity The sound intensity can be varied between 0 and 120 in regular steps of 5. 40 is the standard setting. Press the arrow buttons to increase the sound intensity decrease it. or to The current sound intensity is shown on the display. 5.3 Switching on modulation To dissociate the transmission signal from potential background noise, the signal type can be changed. Press the modulation button and off. to switch the modulation of the signal on The current setting is always shown on the display. ~ Modulation On = Modulation Off 5.4 Switching on the light Press the light button to switch the light on and off. The light automatically switches off after approx. 20 seconds. SONAPHONE T 12

5 Operating the SONAPHONE T 5.5 Setting the display contrast and time Note Contrast and time can be selected individually. The points are dealt with one after the other via the menu navigation. To adapt the view to individual ambient conditions, the display contrast can be altered. The preset value is 50 %. Press the enter key once to go to the "contrast" menu option. Press the arrow buttons between 0 and 100 %. Confirm the value with the enter key to set the display contrast value to go to the "time" menu option. To save energy, you can define the time period after which the device will switch itself off via the settings. Via the arrow keys Minimum running time the following times can now be set: = 1 minute to Maximum running time = 10 minutes = Continuous running Confirm the setting with the enter key to quit the menu. SONAPHONE T 13

6 Cleaning and care 7 Maintenance and troubleshooting 6 Cleaning and care Caution! Incorrect cleaning of the SONAPHONE T and its parts may damage the device. Cleaning is prohibited with abrasive and aggressive cleaning agents by immersion in liquids. 7 Maintenance and troubleshooting Caution! When there are errors or problems, it is not permitted to open the SONAPHONE T or accessories or to undertake repair work on them without authorisation. This may only be carried out by the manufacturer. The SONAPHONE T is practically maintenance free. If errors or problems do occur, please contact the manufacturer. SONAPHONE T 14

8 Technical data 8 Technical data SONAPHONE T, Version 2.0 Ultrasonic transmitter Transmission frequency Functionality Display Approx. 40 khz Adjustable transmission power Switchable frequency modulation Auto power-off function Illuminated LC display Connections Power supply Running time For various transmitters 2 AA batteries or accumulators (optionally via power supply unit) Approx. 100 hours with battery operation Operating temperature -10 C... +60 C Storage temperature -20 C... +60 C Protection type Device: IP54 Probe: IP20 Dimensions Without probe: LWH 130 x 85 x 30 mm With L50 probe: Length ~170 mm Probe: Length ~ 52 mm, Ø ~ 22 mm Items supplied Ultrasonic transmitter, L50 transmitter Optional accessories Laptop carrying bag with foam plastic Extension for the probes Power supply unit SONOSPHERE spherical transmitter Table 6: Technical data for SONAPHONE T SONOSPHERE Half or full spherical transmitter Dimension Ø 100 mm Weight 620 g without accessories Operating temperature -10 C... +60 C Storage temperature -20 C... +60 C Items supplied Separable spherical transmitter with integrated connection cable, case, stand, suction cup, magnet Table 7: Technical data for SONOSPHERE transmitter SONAPHONE T 15