Installation Instructions

Similar documents
Quick Reference Guide

DSS Console and DSS Console for Attendant for Digital Super Hybrid Systems. Reference Guide ANSWER RELEASE

Important Information

Operating Instructions

Panasonic Telephone Systems Reference Manual Propietary Telephone for Electronic Modular Switching System

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Installing the DX LCD Display

Quick Reference Guide Digital Proprietary Telephone

edrive RAM Battery Alternate Replacement Procedure

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Information about IP Proprietary Telephones KX-TDA50/KX-TDA100 KX-TDA200/KX-TDA600

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Quick Reference Guide

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Installation Instructions Model ZAM-180

DIGITAL IO BOX Owner s Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Notes TII Model 341 Protector

Industrial Camera GP-MF602. Before attempting to connect or operate this product, please read these instructions completely.

and above (Standard) and above (Option 74) A14 Replacement (Display Module Subassembly w/touch Panel) VM700T

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

Installation Instructions

THE CTB08D LIGHT CONTOLLER

Removal and Installation8

H704-42(H)(E), H704-42/1(H)(E)

An ISO-9001 Certified Company

Technovision Inc. CD-ROM Audio Sampler. Repair Manual

IBM. Rack Installation Instructions

ColorMaxLP Label Roll Rewinder

Telephone Accessories

Tim Hortons EI30 Ethernet Interface Circuit Board

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

FCB1010 Phantom Power Adaptor

Quick Installation Guide

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Power Supply and Fan Module Installation

Glossary KX-TVA50 KX-TVA200. Voice Processing System. Model No.

Contents. Text Notations. Copyright. Using the digitizer pen (Optional) 10. Contents 3. Basic Items 4. Using the Slate PC Dock (Optional) 11

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

Replacing the Battery HP t5730 and t5735 Thin Clients

Installation Instructions Models CC-5 / CC-2

Installation Instructions

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F)

In-ceiling Housing. Installation Manual SHP-3701F

Power Supply, 17-inch

C-POWER AC AUTOMATIC CONTROL

Replacing the Power Supply

Instructions for installing your QuiltCam on your Gammill quilt machine.

ATMOX Power Supply ATMOX AC Adapter with Plugs. Wiring Guide

Dark Energy Survey Detector Head Electronics Crate Disassembly & Modular Replacement Instructions For Type 2 DAQ & Heater Crates

Installing The Loop Start Line Board In The FX Series Digital Communications System

721EX Access Controller Installation

- 1 - General ordering data Order No

Installation and Maintenance

527F Dual PC Option Installation Guide as replacement for 32MP made by Fadal

LVN5200A-R2, rev. 1, Hardware Installation Guide

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

The Exp-007 unit connects directly to Remote Status Indicator units to provide 2 programmable 1-Amp rated, volt free, clean contact outputs.

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Panduit Basic Rack PDU

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

SW-UNM-24FE2GC-24POE 24 Fast Ethernet Ports PoE + 2 Giga Combo User Manual Ver 1.1

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

Perle Advanced Powered Ethernet Extenders Installation Guide

Getting Started KX-TES824 KX-TEM824. Advanced Hybrid System. Model

Game Operations Manual for 27 Dedicated Video Game

Meridian External Alerter and Recording Interface

Vapor Monitor Interface Module

S Series Stand Assembly Instructions

Brochure. SNK series Terminal blocks PI-Spring technology

Perle MCR200 Installation Guide

Rack Installation Instructions

Getting Started KX-TVM50 KX-TVM200. Voice Processing System. Model No.

CF3000 Dealer Diagnostic Tool Instruction Manual

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

A significantly increased capacity compared to other techniques is achieved with the compact SID-C module.

Install Manual. P2 Software. F0604T7047 -F Printed in Japan VQT0L24-6 (E)

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Model No. Manuals and supporting information are provided on the Panasonic Web site at:

KX-TA824. Installation Manual. Advanced Hybrid System. Model No.

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Quick Start Installation Guide

20-Slot 2U Rack Mount Media Converter Chassis for ET Series 2 Media Converters

KX-TA824. Advanced Hybrid Telephone System. b u s i n e s s

SAMi Installation Instructions

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

TRC-190 User s Manual

Upgrading and Servicing Guide

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

KX-TD816-7 KX-TD1232-7

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

Panduit Basic Rack PDU with Local Meter

Installation Instructions Model PSX-12

Transcription:

Installation Instructions Doorphone Card Model KX-TD161 Please read this manual before installing the card.

Thank you for purchasing the Card. Doorphone Card Supports 4 doorphones and 4 door openers. The doorphone is an option (KX-T30865). Contents Location of the Card..................... 3 Installation for the Card.................. 5 Doorphone Card......................... 7 2

Location of the Card The location of the optional card is shown below. Precaution: To protect the printed circuit boards (Pboards) from static electricity, do not touch parts on the P-boards in the main unit and on the optional cards. KX-TD816 Doorphone Card Connector Doorphone Card Front cover is open. 3

KX-TD1232 Doorphone Card Connector DOORPHONE Doorphone Card Front cover is open. 4

DIGITAL SUPER HYBRID SYSTEM Installation for the Card 1. Set the power switch on the main unit to the OFF position and disconnect the power cord from the AC outlet. D1232 D816 DIGITAL SUPER HYBRID SYSTEM Disconnect from AC outlet Disconnect from AC outlet Power Switch Power Switch 5

DIGITAL SUPER HYBRID SYSTEM 2. Loosen the two screws on the right side of the main unit and open the front cover in the direction of arrow A. D1232 D816 DIGITAL SUPER HYBRID SYSTEM A screw A screw screw screw Note The two screws are attached to the front cover with springs so that they will not be lost. 3. To install the Doorphone Card, see page 7. 4. Close the front cover and screw. 5. Connect the power cord to the AC outlet and then set the Power Switch on the main unit to ON position. 6

Doorphone Card Before installing the Doorphone Card to the main unit, install the Doorphone (KX-T30865). For details about the doorphone, refer to the Installation Manual. 1. Connect two 4-conductor modular connectors to the Doorphone Card Cabinet, and pass the cords through the grooves in the cabinet. 2. Attach the Doorphone Card Cabinet to the main unit and press down. 7

3. Connect the cord to the Doorphone Card Connector. KX-TD1232 KX-TD816 To Terminal Box Installation 8

Wiring of the Doorphone 1. Connect the Doorphone Card to the terminal box using two 4-conductor modular connectors. 2. Connect the wires of doorphone 1 to the red and green screws of the terminal box. 3. Connect the wires of doorphone 2 to the yellow and black screws of the terminal box. 4. Connect the wires of doorphone 3 to the red and green screws of the terminal box. 5. Connect the wires of doorphone 4 to the yellow and black screws of the terminal box. 9

KX-TD816 View of Doorphone Connector Jack Doorphone 4 Doorphone 3 Doorphone 2 Doorphone 1 4-conductor wiring is required. Doorphone 3 (KX-T30865) Yellow Red Terminal Box Doorphone 4 (KX-T30865) Black Green 4-conductor wiring is required. Doorphone 1 (KX-T30865) Yellow Red Terminal Box Doorphone 2 (KX-T30865) Black Green 10

KX-TD1232 View of Doorphone Connector Jack Doorphone 4 Doorphone 3 Doorphone 2 Doorphone 1 4-conductor wiring is required. Doorphone 3 (KX-T30865) Yellow Red Terminal Box Doorphone 4 (KX-T30865) Black Green 4-conductor wiring is required. Doorphone 1 (KX-T30865) Yellow Red Terminal Box Doorphone 2 (KX-T30865) Black Green Note NB Colors shown on the above diagram indicate the internal cable connections of the Terminal Box. 11

Connecting Door Openers 1. Loosen the screw to remove the cover. 2. Loosen the screws on the terminal strip. 12

3. Insert the wires coming from the door openers into holes and tighten the screws. Pass all the wires through the Holder. Holder To door opener 4 To door opener 3 To door opener 2 To door opener 1 Note Set the door opener paired with the doorphone. For wiring, UL 1015, AWG 22 twisted wire or the equivalent is recommended. The wire should be between 1.2 mm and 2.4 mm (3/64 inch and 3/32 inch) in diameter including the coating. D=1.2 mm-2.4 mm (3/64 inch-3/32 inch) 13

14

15

Consumer Electronics Company, Division of Matsushita Electric Corporation of America One Way, Secaucus, New Jersey 07094 www.panasonic.com Sales Company ( PSC ), Division of Matsushita Electric of Puerto Rico, Inc. Ave. 65 de Infantería, Km. 9.5, San Gabriel Industrial Park, Carolina, Puerto Rico 00985 Copyright: This manual is copyrighted by Kyushu Matsushita Electric Co., Ltd. (KME). Under the applicable copyright laws, this manual may not be reproduced in any form, in whole or part, without the prior written consent of KME and its licensee. 2001 Kyushu Matsushita Electric Co., Ltd. All Rights Reserved. Printed in the United Kingdom PSQX2631ZA KA0901HK0