Surge Protection Devices and Surge Protection Kit

Similar documents
Surge Protection Devices Type 1+2

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Surge Protection Devices Ex9UE2

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Type of surge arrester

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

wietap wietap Overvoltage Protection Tensions running high

Overvoltage Protection Devices

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

SPD Catalogue. SPD Catalogue. for AC applications

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

SPM Series Plug-in Surge Protection

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

3 Design of the electrical installation protection system

ETITEC - Lightning and Surge Arresters

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

R3&A Limited, Cobourg, ON

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Surge Protective Device

US Catalog March Surge protective devices (SPDs) UL range

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Lightning Current Equipotential Bonding SPDs

Lightning and Surge Arresters

PT 3-PB-ST. Extract from the online catalog. Order No.:

Modular surge protective devices

NEW surge protective devices

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Modular surge protective devices (SPDs)

Building Surge Protection Information Pack

Surge & Filter Protection Addressing your industrial power quality needs.

Modular surge protective devices (SPDs) Cat. Nos :

SPM Series. Plug-in Surge Protection

Modular surge protective devices (SPDs)

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Overvoltage Protection for low-voltage supplies

Surge protection for gutter heating systems

Autoprotected Surge Arresters New OVR Plus range

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

Coordination of Surge protection devices

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Type Code No. Weight Packaging [g] [pcs]

2 Principle of lightning protection

Electronic timer CT-ERD.12

SURGE PROTECTIVE DEVICES

Lightning and surge protection for single-family houses

Surge protection for frequency converters

Lightning & Surge Protection for Wind Turbine Systems

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Electronic timer CT-AHD.22

PV protective solutions

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Lightning and Surge Arresters

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

Electronic timer CT-ARS.11

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Overvoltage Protection

Surge protection for LED mast lights

Lightning and surge protection for electromobility

Installation / Control Technique

Allen-Bradley 1492-RCDA4A40

Overvoltage Protective Devices

Remote contact signaling available. visual status indication

Reliability in Surge Protection. Photovoltaic Systems.

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

S400 Series HIGH EFFICIENCY SURGE PROTECTIONS. For power supply For measurement and control devices For LAN / ICT Networks

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

BS th Edition wiring regulations Furse overview

L*W*H:120*65*35.5 L*W*H:152*133*48 L*W*H:220*143*48 L*W*H:360*280*132 for 1ph 5A~10A for 1ph 10A~16A for 1ph 20A~45A for 1ph 50A~120A/200kA

Surge Protection for Surveillance Systems

onlinecomponents.com Overvoltage protection Contents Overvoltage protection Overvoltage protection F.1

Electronic timer CT-ERS.21

Cirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Surge Protection for Low Voltage Power Systems

TDS Transient Discriminating Surge Diverters

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

Technology Live Workshop

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Surge protection for telecommunication connections

ic60n RCBO 30 ma IEC , IEC , AS/NZS

US CATALOG SMISSLINE TP

OPTIMISED LUMINAIRE PROTECTION

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Messaging module CP-C MM

OPTIMISED LUMINAIRE PROTECTION

Transcription:

Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down the transient surge as low as possible to protect very sensitive equipment. SPDs can be used in any supply system e.g TNCS, TNS, TT. Options: Replacement cartridges. power supply. Cartridges are available for all discharge currents (40kA and 15kA) with and without condition indication. These transients can cause premature ageing of equipment, downtime, or complete destruction of electronic components and materials. SPDs are strongly recommended on installations that are exposed to transients, to protect sensitive and expensive electrical equipment such as TV, video, washing machines, Hi-Fi, PC, alarm etc. The choice of SPD depends on a number of criteria such as: The risk of lightening strikes The exposure of the building to transients. The sensitivity and value of the electrical equipment that requires protection. Earthing system Level of protection The range of SPDs is separated into 3 types of protection: 1. Main protection - class 1 SPDs with higher discharge current (Imax 10/350), to evacuate as much of the transient overvoltages associated with lightening strikes 2. Main protection - class 2 With a discharge current (Imax 8/20), to evacuate as much of the transient overvoltage to earth as possible protection level (Up 1000V). Technical Data Complies with IEC61643-1 Reserve Status Indicator (R versions) End of Life Indicator (D versions) OK Auxiliary contact for remote signalling (R versions only) 12 11 14 230V~ 1A 12V... 10mA Installation and Connection The main protection SPDs are installed directly after the main incoming switch or RCCB (type S). Connected in parallel to the equipment to be protected. is assured in both common and differential modes. SPDs with Low Let Through Voltage Levels Type 3 To protect very sensitive electronic equipment. This fine protection complements the main protection and can protect 1 or many electronic devices. Optimal coordination is obtained when cascaded with a main protection device. Discharge current Imax. 8kA (8/20 wave) a green LED on the front face indicates the status of the SPD SP202N, connected in series with the equipment that needs to be protected (with a maximum line current of 25A). is assured in both common and differential modes Connection Capacity Terminal blocks L, N & E Rigid conductor: 10mm 2 Flexible conductor: 6mm 2 Replacement Cartridges The cartridges replace the cartridge in the main SPN* devices. They allow simple replacement without the need to cut-off the A keying system exists to prevent a line cartridge being interchanged by mistake with a neutral one and visa versa neutral cartridges have a discharge current of 65kA For technical details see page 4.33-4.37 TNS TNC-S TT SPA201 SPA400 SPA401 SPN800 SPN801 SPN802 SPN215D SPN240D SPN415D SPN440D SP202N Class 1 + 2 (Class 1 + 2 + 3 if less than 5m) (with lifetime indicator) Poles I imp ka I imp ka I n In Up kv Single or Width (mm) Cat ref. Cat ref. 2 12.5 25 - - 1.5 Single 35 SPA201* - 3 12.5 37.5 - - 1.5 Three 70 SPA400* - 4 12.5 50 - - 1.5 Three 70 SPA401-3 25 75 - - 1.5 Three 105 SPN800 SPN800R 4 25 100 - - 1.5 Three 140 SPN801 SPN801R 4 25 100 - - 1.5 Three 140 SPN802 SPN802R * These SPD devices are of the monoblock type construction. At end of life, the complete product should be replaced. SPN800R Replacement Cartridges (SPN8* range) Dimensions Phase replacement for SPN800, SPN800R, SPN801, SPN801R, SPN802 & SPN802R Neutral replacement for SPN801, SPN801R, SPN802, SPN802R Cat ref. SPN080 SPN080N SPN080N 4.30 General Catalogue

Class 2 (with lifetime indicator) 2 - - 5 15 1.2 Single 35 SPN215D SPN215R 2 - - 15 40 1.5 Single 35 SPN240D SPN240R 4 - - 5 15 1.5 Three 70 SPN415D SPN415R 4 - - 15 40 1.5 Three 70 SPN440D SPN440R Replacement Cartridges SPN415D Dimensions Phase replacement for SPN140D Phase replacement for SPN215D & SPN415D Phase replacement for SPN215R & SPN 415R Neutral replacement for SPN215D, SPN415D, SPN215R & SPN415R Cat ref. SPN040D SPN015D SPN015R SPN040N SPN040D Class 3 (fine protection) (with lifetime indicator) 2 - - 3-1.5 Single 35 SP202N - PV Applications (DC side) (with lifetime indicator) 3 - - 12.5 25 4-52.5 SPV325 - SPV325 Consumer Unit Kit Type 2 SPD with SPN215D (with lifetime indicator) Consists of: Neutral terminal bar, 3x 20mm neutral link bar 370mm, 300mm & 200mm lengths, 4mm 2 neutral, live & earth cables, 2 connector busbar, 4 way terminal bar, terminal bar clip, 1x Double Pole SPD s, 32A MCB 2 - - 5 15 1.2 Single 35 VA02SPD - Customer Services Hotline 01952 675612 Technical Support Helpline 01952 675689 4.31

Type 2 / Class II Surge SPN215*, SPN240*, SPN415*, SPN440* & SPV325 SPA201 SPA400 SPA401 Tested to EN 61643-11 2002-12 L Þ N N Þ PE L1/L2/L3 Þ PEN L1/L2/L3 Þ N N Þ PE SPD type / class T1 / Class I Energy-coordinated Type 1 + Type 2 protection effect on terminal equipment Energy-coordinated Type 1 + Type 2 + Type 3 protection effect on terminalequipment 5 m Type of power supply TT / TN system TN-C system TT / TN-S system system Type of protection common and differential modes common modes common and differential modes Nominal voltage U N 230V/400V ac Rated voltage U c 255V ac Voltage protection level U p 1.5kV TOV Voltage U T 440V / 5s 1200V / 200ms 440V / 5s 440V / 5s 1200V / 200ms Rated load current I(L) nc I(L-L) nc Follow current interrupting I fi 25kA rms 100A rms 25 ka rms 25kA rms 100A rms rating Nominal discharge current I n 12.5kA 25kA 12.5kA (L-PEN) 37.5kA (total) 12.5kA 50kA (8/20) Impulse current (10/350) I imp 12.5kA 25kA 12.5kA (L-PEN) 37.5kA (total) 12.5kA 50kA Maximal rating of fuse 160A gl / gg MCB nc Short-circuit withstand fuse 25kA rms capability with max. MCB nc Response time t A 100ns Operating temperature range J - 40 C.+ 80 C Indication of SPD disconnector Green/Red flag on L and N Green/Red flag on L1, L2, L3 Green/Red flag on L1, L2, L3 and N Cross sectional area min 1,5mm 2 solid / flexible max 35mm 2 stranded / 25mm 2 flexible 4 Nm Enclosure material grey thermoplastic, UL 94V-0 Modular width 2 4 4 Weight 275 g 385.9 g 479.9 g Approval marking KEMA Customer Services Hotline 01952 675612 Technical Support Helpline 01952 675689 4.33

Type 1 / Class I Surge SPN8*** Tested to EN 61643-11 (VDE0675-6-11) 2002-12 SPN800 / SPN800R SPN801 / SPN801R SPN802 / SPN802R EN 61643-11 (VDE0675-6-11) 2002-12 EN 61643-11 (VDE0675-6-11) 2002-12 L1/L2/L3 Þ PEN L1/L2/L3/N Þ PE L1/L2/L3 Þ N N Þ PE SPD type / class T1 / I / B Type of power supply system TN-C - System TN-S - System TT - System Type of protection Common modes Common and differential modes Nominal voltage U N 230V / 400V ac Rated voltage U c 255V ac Voltage protection level U p 1.5kV 255V ac TOV-voltage U T 440V / 5s 1200V / 200ms Rated load current I(L) 315Aeff I(L-L) 125Aeff Follow current interrupting rating I fi 50 kaeff 100kA Nominal discharge current (8/20) I n 75kA 100kA 25kA 100kA Impulse current (10/350) I imp 75kA 100kA 25kA 100kA Residual current I PE 100mA Maximal rating of overcurrent fuse 125A gl / gg serial or 315A parallel protection MCB 125A serial or 160A parallel C curve Short-circuit withstand capability with max. fuse 50kA eff ac 25kA eff ac MCB 50kA eff ac 25kA eff ac Response time t A < 100ns Isolationswiderstand Risol --- Operating temperature range J - 40 C.+ 60 C Indication of SPD disconnector Green - red on L1, L2, L3 Green - red on L1, L2, L3, N Cross sectional area min 10mm 2 solid / flexible L1, L2, L3, PE max 50mm 2 multi-stranded / 35mm 2 flexible L1', L2', L3', PE max 35mm 2 multi-stranded / 25mm 2 flexible 7.0 Nm Enclosure material grey thermoplastic, UL 94V-0 Modular width 6 8 Weight 970 g 1260 g 1272 g Approval marking VDE 4.34 General Catalogue Technical

Type 2 / Class II Surge SPN215*, SPN240*, SPN415* & SPN440* SPN215D/R SPN240D/R SPN415D/R SPN440D/R Tested to EN 61643-11 (VDE0675-6-11) 2002-12 SPD type Type 2 according to EN61643-11 SPD class Class II according to IEC61643-1 Maximum continuous operationg voltage U c Phase / Neutal 255V Neutral/ PE 275V Voltage protection level U p 1kV 1.2kV 1kV 1.2kV Nominal discharge current (8/20 µs) I n 5kA 15kA 5kA 15kA [(DC+/DC-) --> PE] Max. discharge current (8/20 µs) [(DC+/DC-) --> I max 15kA 40kA 15kA 40kA PE] Short-circuit withstand capability with max. 10kA - 32A 20kA - 32A 10kA - 32A 20kA - 32A Operating temperature range J - 40 C.+ 80 C Indication of SPD disconnector Green - Yellow - Red Cross sectional area min 1,5mm 2 solid / flexible max 35mm 2 multi-stranded / 25mm 2 flexible 4.0 Nm Enclosure material grey thermoplastic, UL 94V-0 Modular width (DIN 43880) 2 4 2 4 Auiliary contact. Voltage/ nominal current (only applicable on the R suffix products) 230V/ 0.5A 12Vdc 10mA Customer Services Hotline 01952 675612 Technical Support Helpline 01952 675689 4.35

Type 2 / Class II Surge SPV325 SPV325 Tested to EN 61643-11 (VDE0675-6-11) 2002-12 SPD type Type 2 according to EN61643-11 SPD class Class II according to IEC61643-1 Maximum continuous operationg voltage Uc PV 1000V Voltage protection level U p 4kV Voltage protection level for 5kA U p 3,5kV Total discharge current (8/20 µs) I total 40kA Nominal discharge current (8/20 µs) I n 12.5kA [(DC+/DC-) --> PE] Max. discharge current (8/20 µs) I max 25kA [(DC+/DC-) --> PE] Short-circuit withstand capability with max. I scwpv 50 A / 1000 V DC Response time t A 25ns Operating temperature range J - 40 C.+ 80 C Indication of SPD disconnector green - red Cross sectional area min 1.5mm 2 solid / flexible max 35mm 2 multi-stranded / 25mm 2 flexible 4.0 Nm Enclosure material Grey thermoplastic, UL 94V-0 Installation width 3 modules, DIN 43880 Weight 316g 4.36 General Catalogue Technical

Type 3 / Class III Surge SP202N Characteristics Tested to EN 61643-11 (VDE0675-6-11) 2007-08 SPD type / class T3 / III Ports one port Type of power supply system TT / TN system Nominal voltage U N 230V ac Rated voltage U c 255V ac Voltage protection level ( L- N) U p 1.25kV Voltage protection level (L/N - PE) U p 1.5kV TOV - Characteristic (L - N) U T 335V / 5s TOV - Characteristic (L/N - PE) (I) U T 400V / 5s TOV - Characteristic (L/N - PE) (II) U T 1200V / 200 ms Rated load current IL 16 Aeff Nominal discharge current (8/20) I n 3kA Maximal discharge current (8/20) I max 5kA Combination wave (1,2/50-8/20) (L - N) U oc 6 kv Combination wave (1,2/50-8/20) (L/N - PE) U oc 10 kv Residuel current IPE 5μA Remplacement cartridge NO Maximal rating of fuse 16 A gl / gg MCB 16A B curve Short-circuit withstand capability with max. fuse 6kA eff ac MCB 1kA eff ac Response time t A 25ns Operating temperature range J - 25 C.+ 40 C Indication of SPD disconnector NO Remote signalisation contact Green light off Cross sectional area min 1.5mm 2 solid / flexible max 10mm 2 stranded / 6mm 2 flexible 1.2 Nm Enclosure material Grey thermoplastic, UL 94V-2 Installation width 2 modules, DIN 43880 Reserve Indicator Light Neutral cartridges cannot be put into spares reserved for phase cartridges and visa versa. Normal Reserve End of Life Customer Services Hotline 01952 675612 Technical Support Helpline 01952 675689 4.37