DICOM Conformance Statement

Similar documents
No. MIIUS0015EA DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM APLIO MODEL SSA-770A TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

DICOM Conformance Statement

SCORE 3D Workstation DICOM CONFORMANCE STATEMENT

AVIA (Dx MM) DICOM 3.0 Conformance Statement

DICOM Conformance Statement

This document contains confidential information that is proprietary to SonoSite. Neither the document nor the information contained therein should be

DICOM Conformance Statement

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

HCP DICOM Net DICOM Conformance Statement

DBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1

nstream Version 3.1 DICOM Conformance Statement

Kodak Point of Care CR systems. DICOM Conformance Statement

X-Porte DICOM Conformance Statement

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

DICOM Conformance Statement FORUM

DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-037A and XIDF-038A or SRS-1000A

DICOM Conformance Statement, Biim Ultrasound App Version 1

DICOM Conformance Statement * /02* /02 MADE IN GERMANY

DICOM 3.0 Conformance Statement for PlatinumOne Systems

Philips Medical Systems. Xcelera R1.1L1. Document Number XPR July 2003

Carl Zeiss Meditec AG

SonoWin Picture Archiving System

DICOM Conformance Statement. Forum

Philips Medical Systems DICOM Conformance Statement. Inturis Suite R2.2

DICOM Conformance Statement

Carl Zeiss Meditec AG

Whole Body X-ray CT System Supria. DICOM Conformance Statement

DICOM Conformance Statement FORUM

DICOM Conformance Statement

DICOM Conformance Statement for IMAGEnet 5

Philips Medical Systems DICOM Conformance Statement USIT 1.5 L3

DICOM Conformance Statement for GALILEI. Software Version V6.0

Punctual Dicom Workstation

DICOM Conformance Statement for PenFetch

Philips Medical Systems DICOM Conformance Statement USIT 1.5

Retinal imaging control software NM. DICOM Conformance Statement

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

TOSHIBA AMERICA MEDICAL SYSTEMS

Uscan. DICOM Conformance Statement

Sidexis 4 with Sidicom RM

DICOM Conformance Statement

MediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English

DICOM Conformance Statement

DICOM Conformance Statement. EasyWeb 3.0. Document Number XZR January Copyright Philips Medical Systems Nederland B.V.

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

Philips Medical Systems DICOM Conformance Statement. EasyWeb 2.0. Document Number April 1999

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

DICOM Conformance Statement

DICOM Conformance Statement

Whole Body X-ray CT System Supria. DICOM Conformance Statement

ETIAM Nexus. DICOM Conformance Statement.

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT

Philips Medical Systems DICOM Conformance Statement. CT Aura Release 1.3

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM. Infinix Celeve-i series / Infinix-i series Model XIDF-3DP801 AND ANGIO WORKSTATION

DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement. for ES9410 DICOM

Topcon Medical Systems

Aloka ProSound DICOM

DICOM Conformance Statement

DICOM 3.0 Conformance Statement. DICOM PRI v. 4.64

FusionXD 2.1 DICOM Conformance Statement

FusionXD 2.0 DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

XPACS DICOM 3.0 Conformance Statement Document Version October 2004

CMT MEDICAL TECHNOLOGIES

TITAN DICOM Conformance Statement

Carl Zeiss Surgical GmbH

Carl Zeiss Surgical GmbH

DICOM Conformance Statement

Technical Publications

QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

Aspen TM Ultrasound System DICOM Conformance Statement Aspen 7.0

Technical Publications

SIEMENS. DICOM Conformance Statement

DAR Revision Date: July,

CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT STORAGE SCU FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-053A or XIDF-056A (MIIXR0001EAB)

DICOM Conformance Statement VISIQ 1.0

Technical Publications

Philips Medical Systems. Intera Document Number April 2003

DICOM Conformance Statement. DSI Release 4.4. Document Number June Copyright Philips Medical Systems Nederland B.V.

Technical Publications

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DCMburner version 3.3.0

Dx Server for Windows NT DICOM 3.0 Conformance Statement

SYNAPSE 3D Conformance Statement FUJIFILM SYNAPSE 3D V3.0. Conformance Statement. Revision Z45N

Dx Server for Windows NT DICOM 3.0 Conformance Statement

OASIS V4.0 DICOM Conformance Statement Rev. 3

Raffaello Conformance Statement for DICOM V3.0

DICOM Conformance Statement. for C911 DICOM PRINTER SERIES : C911/C931 DICOM ES9411/ES9431 DICOM Pro9431 DICOM

Sonovision DICOM Conformance Statement

DICOM. Conformance Statement For VINNO Medical Ultrasound System Revision 2.0. Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd.

Digital Lightbox 1.0

DICOM Conformance Statement

Technical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG

DICOM Conformance Statement

Technical Publications

Transcription:

DICOM Conformance Statement -- Offline media storage support -- PRO NM, VISUCAM VISUCAM and VISUCAM NM FA Opt AF SW - Version 4.2 NM FA Carl Zeiss Meditec AG Göschwitzer Str. 51-52 07745 Jena Germany +49 3641 220 333 December, 2007 Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 1

Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 2

Contents 1 INTRODUCTION... 4 1.1 PURPOSE... 4 1.2 SCOPE... 4 1.3 DEFINITIONS... 4 1.4 REFERENCED DOCUMENTS... 5 2 IMPLEMENTATION MODEL... 5 2.1 APPLICATION DATA FLOW DIAGRAM... 5 2.2 FUNCTIONAL DEFINITION OF APPLICATION ENTITIES... 6 2.3 SEQUENCING OF REAL WORLD ACTIVITIES... 6 3 APPLICATION ENTITY SPECIFICATIONS... 6 3.1 FILE META INFORMATION FOR APPLICATION ENTITY... 6 3.2 IMPLEMENTATION IDENTIFYING INFORMATION... 6 3.3 REAL-WORLD ACTIVITIES FOR THIS APPLICATION ENTITY... 6 3.3.1 Real-World Activity: Export to local export media... 6 3.3.2 Real-World Activity: Reading from local media... 6 4 EXTENSIONS, SPECIALIZATIONS AND PRIVATIZATIONS OF SOP CLASSES... 7 4.1 ACQUISITION CONTEXT MODULE... 7 4.1.1 Acquisition Context Sequence Coding Schemes... 7 4.2 FURTHER SPECIALIZATIONS... 9 5 CONFIGURATION... 9 5.1 ACQUISITION CONTEXT SETTINGS... 9 5.2 TRANSFER SYNTAX SETTINGS:... 9 6 SUPPORT OF EXTENDED CHARACTER SETS... 10 7 ANNEXES... 11 7.1 VL PHOTOGRAPHIC IMAGE IOD... 11 Formatiert: Nummerierung und Aufzählungszeichen Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 3

1 Introduction 1.1 Purpose This DICOM Conformance Statement was written according to part PS 3.2 of the DICOM Standard. The intended audience for this Conformance Statement is hospital technical staff, system integrators and software engineers. The reader is assumed to have good understanding of the DICOM standard. The Conformance Statement of one implementation can be compared with the Conformance Statement of another implementation to determine which capabilities are commonly supported. DICOM does not, by itself, guarantee interoperability. Furthermore, the identification of common capabilities by comparing DICOM Conformance Statements is also not sufficient to guarantee connectivity between two devices. A DICOM Conformance Statement cannot replace validation and cross-vendor testing with other devices. Validation and cross-vendor testing are still required to ensure that both devices are performing as intended. 1.2 Scope The application described in this document is the VISUCAM NM Software from Carl Zeiss Meditec AG, Germany. This software acts as DICOM File Creator and DICOM File Reader. Creation/Reading of File-Sets and DICOMDIR is not supported. 1.3 Definitions Term ACR-NEMA AE DCO DICOM File DIMSE DIMSE-C File-Set FSC FSR IOD PACS Definition American College of Radiology National Electrical Manufacturers Association. Application Entity DICOM Composite Object. A DICOM object such as an image, overlay, lookup-table, waveform, presentation state or radiotherapy plan which can be stored using the Storage Service Class. A DICOM File is a File with a content formatted according to the requirements of this Part of the DICOM Standard. In particular such files shall contain, the File Meta Information and a properly formatted Data Set DICOM Message Service Element DICOM Message Service Element Composite A File-set is a collection of DICOM Files (and possibly non-dicom Files) that share a common naming space within which File IDs are unique. File Set Creator. An Application Entity that creates the DICOMDIR File (see section 8.6) and zero or more DICOM Files. File Set Reader. An Application Entity that accesses one or more files in a File-set. Information Object Definition Picture Archiving and Communication System Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 4

Term SC SCP SCU SOP UID VR VISUPAC Definition Service Class Service Class Provider Service Class User Service Object Pair Unique Identifier Value Representation Fundus Imaging System by CZMS, Pirmasens 1.4 Referenced documents Document Number Title DICOM, PS 3.1-3.17-2004, National Electrical Manufacturers Association, 1300 N. 17 th Street Rosslyn, Virginia 22209, USA. Revision 2004 2 Implementation Model The VISUCAM DICOM services are implemented as a single Application Entity which acts as Image Creator and provides the possibility of writing and reading DICOM files. It provides an interface to CD-R/RW, other mass storage devices and network connected file systems. The VISUCAM software includes a database for configuring and managing operating parameters. 2.1 Application Data Flow Diagram Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 5

2.2 Functional Definition of Application Entities The VISUCAM Application Entity is designed to create DICOM images and write them to (shared) hard disk or an offline medium. It is capable of: Creating a new File onto an external medium (e.g. CD-RW/DVD-RW, memory stick) Writing a new File to a network file system Reading a new File from a medium or a network file system 2.3 Sequencing of Real World Activities The order of execution of the described Real-World Activities is not relevant. Each described Real-World Activity is executed independently from the other one. 3 Application Entity Specifications The VISUCAM software acts as a single Application Entity (AE). Application Profiles Real World Activity Role SC option Supported N/A Export to local export media File N/A Creator N/A Read from local media File Reader N/A 3.1 File Meta Information for Application Entity The Source AE-Title is VISUCAM PRO NM or "VISUCAM NM FA" depending on the base instrument. 3.2 Implementation Identifying Information Implementation Class UID: 1.2.276.0.75.2.1.20.1.4 Implementation Version Name: V_4_x 3.3 Real-World Activities for this Application Entity 3.3.1 Real-World Activity: Export to local export media The VISUCAM application acts as file creator when requested to copy SOP Instances from the local storage to local file export medium. Further on VISUCAM can write DICOM-Files to network directories. 3.3.2 Real-World Activity: Reading from local media The VISUCAM application acts as File Reader when requested to copy SOP Instances from the local medium to the local storage. Further on, VISUCAM can read DICOM-Files from network directories. Information Object Definitions SOP Class UID Transfer Syntax and UID Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 6

VL Photographic Image Storage 1.2.840.10008.5.1.4.1.1.77.1.4 Implicit VR Little Endian Uncompressed 1.2.840.10008.1.2 JPEG Baseline compressed 1.2.840.10008.1.2.4.50 4 Extensions, Specializations and Privatizations of SOP Classes 4.1 Acquisition Context Module For exact information in fundus images, a few additional parameters, not defined in the VL-IOD are needed. These parameters are stored in a private Acquisition Context Sequence as defined below. The VISUCAM application utilizes a special Coding Scheme to encode the Acquisition Context Module in two different versions: Coding Scheme "99HIKO": Coding Scheme Designator (0008,0102): Coding Scheme Version (0008,0103): Coding Scheme Version (0008,0103): 99HIKO VP4.0 VP3.2 The coding scheme version to use is defined by configuration in the VISUCAM application. As default coding scheme version VP4.0 is used. The coding scheme version VP3.2 is used for backward compatibility reasons. 4.1.1 Acquisition Context Sequence Coding Schemes Coding Scheme Version 99HIKO, VP4.0 Coding Type Concept Code Code Names Code Values / Range Code Meaning / Comments Sensor Protocol Name "STANDARD_POSITION" "CENTER_POSITION" "OPTIC_DISK" "NO_PROTOCOL" "CZM_2_FIELDS" "CZM_3_FIELDS" "CZM_5_FIELDS" "CZM_7_FIELDS" "ETDRS_7_FIELDS" The name of the multiple field fixation protocol the image belongs to Stereo Stereo Indicates if image is part of a stereopair. Only present in stereo images Stereo laterality Stereo exam SOP instance UID Left Right Only present in stereo images The IUID of the stereo pair, the given image belongs to. Only present in stereo images Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 7

Coding Scheme Version Coding Type Numeric Value with Unit Description.. see obove 99HIKO, Text Value VP3.2 Numeric Value Code Names Code Values / Range Code Meaning / Comments Angle Flash Gamma Sensor Gain Max number of fixation points Fixation Point The number of fixation positions of a multiple field fixation protocol The fixation position index Fixation point X The fixation point x - coordinate Fixation point Y The fixation point y - coordinate Fixation point angle X Fixation point angle Y Focus aid Focus position Eye section Stereo offset X Stereo offset Y Sensor Protocol Name Stereo Stereo laterality Stereo exam SOP instance UID Angle Flash Gamma Sensor Gain Fixation point Max number of fixation points Fixation point X Fixation point Y Fixation point angle X Fixation point angle Y Focus aid Focus position Eye section 1 : On 0 : Off 0 : Anterior 1 : Posterior Not implemented Not implemented Relative offset X of right stereo image to left in image pixels Relative offset X of right stereo image to left in image pixels Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 8

Coding Scheme Version Coding Type Code Names Code Values / Range Code Meaning / Comments Pixel Width Pixel Height Stereo offset X Stereo offset Y The coding scheme stored depends on configuration (see Chap. 5) 4.2 Further Specializations VISUCAM Software uses value multiplicity 4 for ImageType (0008, 0008). The third value is not used and is intended to be empty: ORIGINAL/DERIVED PRIMARY/SECONDARY COLOR/GREEN/RED/BLUE/FAG/ICG/AF/MONTAGE 5 Configuration Configuration should only be performed by staff with administrative training. 5.1 Acquisition Context Settings For switching between Acquisition Context Coding scheme versions, when creating a DICOM File, the following VISUCAM MainU.ini file entry is used: [Import/Export] VISUPAC=0/1 Meaning: VISUPAC DICOM Compatibility 0... VISUPAC 3.5 and older -> Coding Scheme Version VP3.2 1... from VISUPAC 4.0 -> Coding Scheme Version VP4.0 Default Value: 1 5.2 Transfer Syntax settings: This setting affects DICOM file creation. [Import/Export] DICOMTransferSyntax =0/1 Meaning: 0... Little Endian uncompressed -> Transfer Syntax: 1.2.840.10008.1.2 1 JPEG Baseline compressed -> Transfer Syntax: 1.2.840.10008.1.2.4.50 Default Value: 0 Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 9

6 Support of Extended Character Sets The extended character sets listed the following table supported: ISO-IR 100 Latin Alphabet Supplementary Set No. 1 (ISO 8859-1) Note, the DICOM default character set (ISO-IR 6) is a subset of ISO-IR 100. Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 10

7 Annexes 7.1 VL Photographic Image IOD Module Attribute Tag Type Description PATIENT Patient Name (0010,0010) 2 Patient ID (0010,0020) 2 Patient Sex (0010,0040) 2 User selected: M, F or O Patient Birth Date (0010,0030) 2 Other Patient Ids (0010,1000) 3 Patient Comment (0010,4000) 3 GENERAL STUDY Study Instance UID (0020,000D) 1 Study Date (0008,0020) 2 Referring Physician's Name (0008,0090) 2 Accession Number (0008,0050) 2 Study Description (0008,1030) 3 GENERAL SERIES Modality (0008,0060) 1 XC for newly captured images SC for modified or imported images Series Instance UID (0020,000E) 1 Series Date (0008,0021) 3 Series Time (0008,0031) 3 Operators Name (0008,1070) 3 Performing Physician s Name (0008,1050) 3 Body Part examined (0020,0015) 3 HEAD GENERAL EQUIPMENT Laterality (0020,0060) 2C R or L or U Manufacturer (0008,0070) 2 Carl Zeiss Meditec AG Institution Name (0008,0080) 3 Institution Address (0008,0081) 3 Station Name (0008,1010) 3 Institutional Department (0008,1040) 3 Name Manufacturer Model Name (0008,1090) 3 Device Serial Number (0018,1000) 3 Software Version (0018,1020) 3 GENERAL IMAGE Instance Number (0020,0013) 2 Content Date (0008,0023) 2C Image Type (0008,0008) 3 4 Items: 1. ORIGINAL DERIVED 2. PRIMARY 3. -empty- 4. FAG COLOR RED BLUE GREEN AF ICG MONTAGE Acquisition Date (0008,0022) 3 Acquisition Time (0008,0032) 3 Content Time (0008,0033) 2C Image Comments (0020,4000) 3 IMAGE PIXELS Samples per Pixel (0028,0002) 1 3 for color images, 1 for monochrome images Photometric Interpretation (0028,0004) 1 RGB for color images, MONOCHROME 2 for monochrome images Planar Configuration (0028,0006) 1C Necessary for color images, then it has value 0 (for colorby-pixel). Rows (0028,0010) 1 Number of rows. Columns (0028,0011) 1 Number of columns Bits Allocated (0028,0100) 1 8 Bits Stored (0028,0101) 1 8 High Bit (0028,0102) 1 7 Pixel Representation (0028,0103) 1 0 Pixel Data (7FE0,0010) 1 SOP COMMON SOP Class UID (0008,0016) 1 1.2.840.10008.5.1.4.1.1.77.1.4 MODULE SOP Instance UID (0008,0018) 1 Additional Tags Pixel Spacing (0028,0030) 3 Only available if using acquisition context VP4.0 Acquisition Context Sequence (0040,0555) 3 Document: DICOM Conformance Statement VISUCAM 4.2.doc Document Number: 2005-50172 Page 11