SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud Rate External Readers (REV) BUSY CN Host TX Host RX 8 Host CH CH CN CH TX CH RX CN CN CH TX CH RX 8 Reset (Hold till BUSY is blinking) ~ bit / ARM MHz / Flash KB 08KB (MB) ~ VDC < W Connector Table Value DIP SW Node 0 Node 0 Node 0 Node Node RS-8 : 900 bps (N, 8, ) Ethernet : 0/00M Base T RS-8 + WG CN/CN/CN Wiring Diagram CN8 AR-H Connect to PC via TCP/IP TCP/IP Module CN8 8 K Door CN/CN/CN CN0/CN/CN9 K Door K ALM Door/ Relay Ouput Power Temperature Digital Input Relpy Output Door Relay Time Relay Time User Capacity Event log Fire ALM DI WG PORT0 WG PORT Dip-switch Node ID is set by Relay CN/CN8 DIP_Switch, Node ID: 00~ 8 8 AR-0B-X Fit mm DIN Rail or Mount directly -0 ~ +0 Door Open Button/ Door Sensor/ Fire-alarm Door Relay / Relay Toggle, 0.~00 Sec. Toggle, 0.~00 Sec.,000,000 Connector CN8 Host TCP/IP TCP/IP Socket CAT Connector CN Host RS-8 LA+ LB- CN Host RS-8(A+) Host RS-8(B-) Connector: CN CH Slave RS-8 LA+ LB- RS-8(A+) RS-8(B-) Connector CN CH Slave RS-8 LA+ LB- RS-8(A+) RS-8(B-) Connector CN/CN/CN WG Door / Relay Relay Output Door Relay Output (WG) Door 0 Relay Output () K-/ K-/ K-/ V Converter B- A+ Fire-ALM Aux. WG Port Anti-pass-back Lift Control Door Group Time Zone Real-time Clock DIP_SW WG G R SEN () EGR: PB () WG / WG Reserved Yes (stand-alone /networking) YES 8 (Node ID: ~) Connector CN/CN8 Power Supply VIN (E-V) VOUT(Slave units) Input VDC Input Output VDC Output Connector CN9/CN0/CN WG Port WG G R SEN () EGR: PB () Connector CN Fire-alarm Input Wiegand DAT: 0 Input Wiegand DAT: Input Beeper Output Green Output Red Output Door Status Input Exit Button Input Connector CN/CN/CN WG Port 0 Connect to PC via Host (RS-8) Wiegand DAT:0 Input Wiegand DAT: Input Beeper Output Green Output Red Output Door Status Input Exit Button Input Fire-alarm Input DC Power Output V VDC HUB AR-E-V AR-E-V TCP/IP Module CN8 CN8 (VIN) V () CN B- A+ CN8 (VIN) V () V VDC
-Door Controller V0 AR-H WG Port 0/ Connect to Electric Strike WG Port 0/ Connect to Magnet Lock or Electric Bolt Door Sensor EXIT G R WG WG 0 V WG Reader A/B Door Sensor EXIT G R WG WG 0 V WG Reader A/B Push Button CN9-CN PB SEN LR LG AR-E-V WG Port 0/ WG Push Button CN9-CN PB SEN LR LG AR-E-V WG Port 0/ WG CN CN CN Door0 Door (VOUT) V CN () VDC CN CN CN Door0 Door (VOUT) V CN () VDC VDC (Jumper) (Jumper) Electric Strike VDC VDC (Jumper) (Jumper) or Magnet Lock Electric Bolt VDC If the wire length of Controller and Reader is more than 00 meters, it is recommended NOT to use the "Wiegand Power." Check connection mode within the dashed box: Controller and Reader must use the "common--point." AR-H RS-8 CH/CH Port Connect to Electric Lock Connect to or Other Equipment Door Sensor Push Button EXIT AR-E-V RS-8 Port CN CN CH CH SEN PB ALM B- V A+ RS-8 Reader VDC Magnet Lock or Electric Bolt Electric Strike Lock Power VDC Fire Equipment Fire DI AR-E-V CN CN VDC Firmware Upgrade Get the upgrade software from SOYAL or our distributor and run UdpUpdater software, which has been included in SoyalDeviceTools.exe Execute the software The software is within SOYAL CD or please login the SOYAL website to download Update the firmware [Please login the SOYAL website: www.soyal.com to download the new ISP Firmware.] AR-E-V APSEv_V00 00. Input the Target Address and Port. [Load F/W] open the documents that have the new ISP Firmware. Click the new ISP Firmware and [Open] it. Click [Update F/W] to start the firmware update. Done when the screen shows [Firmware Update is Complete]
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 IP Setting Open your Web Browser and input factory default IP address: http://9.8.. If the IP address of AR-E-V has been changed, we must enter the new IP address. Page menu Current Status Network Setting User Password Monitor the on-line computer IP Setting Change the Log-in information Current State Online Status is able to be monitored showing which computer is linking on Ethernet Module Show which computer is linking on Ethernet Module. Current IP address of the AR-E-V Log-in User Password When you choose the "Networking Setting" or "User Password," Log-in window will pop out and please input user name and password. At the Factory Default Status - User name: admin Password: None by default, so please just go skip and click OK to log-in admin Networking Setting You will see initial IP Address 9.8.. and make sure MAC Address is identical to the sticker on Ethernet Module device. Please alter the IP address as you want, and then click Update button. After updating the IP, please re-connect the Web Browser with the new IP address. User Password Change the log-in password to lock the IP setting of Ethernet Module. The password can be made up of 0 characters at most, and it can be either A~Z or 0~9.
-Door Controller V0 Factory Reset Reset Button: When the device's power is on, press the RESET button on the main board untill the BUSY is blinking. Once RESET the IP, the IP address will be changed back to default value : 9.8.. (Refer to picture) Remarks: When the controller is connected to the power, [] will turn on green ; if there is no light, it means the power supply has some problems. BUSY When the red is lit, the memory is being cleared and restored to the factory default action. If you do not perform "Flash Restoring", but the [RESET] and [BUSY] has been blinking in red, that indicates a PCB problem should be excluded. RS-8 Connection: HOST RX & HOST TX [HOST RX] : When receiving incoming data from the host PC, the green will keep blinking [HOST TX] : When transmitting the data back to the host PC, the red will be blinking Initial Setup: Hardware: Node ID / Reader ID Setting E-V Node ID is set up by shifting the 8-pin dip-switch on the main board. Power Set up node number by 8 dip-switch (Please Refer to the value chart of Connector Table) Re-apply the power 8 8 [e.g.]: Node: 00 Node: 00 Node: 00 Node: 008 8 8 8 8 8 + ++ 8 CH Slave RS-8 Reader: Node ID fixed to start at 00 Key-Panel Type: Access programming mode: Input or PPPPPP 00 00 Exist programming mode LCD Type: Access programming mode Parameters[] Node ID Input New Node ID : or 00 (default value:00, CH Node ID fixed to 00) Door Number (H) : 0~ (Default Value: 00, Skip or Set up as same as E-V's Node ID) Door Number (L): 0~ (Default Value: 00, Skip or Set up as same as Door Number on 0Server) Show UID (0=No, =WG, =ABA, =HEX) Succeeded CH RX & CH TX [CH RX] : When receiving incoming data from Access Controllers of Node, the green will keep blinking [CH TX] : When transmitting data back to Access Controllers of Node, the red will be blinking CH Slave RS-8 Reader: Node ID fixed to start at 009 Key-Panel Type: The same as above CH but Node ID must be 009 LCD Type: The same as above CH but Node ID must be 009 CH RX & CH TX [CH RX] : When receiving incoming data from Access Controllers of Node 9, the green will keep blinking [CH TX] : When transmitting the data back to Access Controllers of Node 9, the red will be blinking WG Port 0: Fixed at Node ID 0 in system and no need to set up WG Port : Fixed at Node ID 08 in system and no need to set up Software: Connection. Open the "0 Server" Software There are two ways to open the Communication Port setting window: and Communication Port Setting a. According to the computer Detection results to select the port (Use the RS-8) b. Select [TCP/IP Oonly] (Use the Ethernet) c. Select the option: Polling Message From Controller d. Polling Interval: 00ms - meaning the PC polls the controller every 00ms once it accesses the message from the controller e. Click YES
-Door Controller V0 Software: Connection. After Port setting, there are two ways to open the Node Number for Polling window: and Node Number for Polling f. Select node ID (for example:00) and access controller " 88/8/8x_Hv/Ev/Ev" g. If use the Ethernet mode, please check the "IP"; if use the RS-8 mode, there's no need to check h. If use the Ethernet mode, input IP in "IP Address" column (Default value: 9.8..) i. Input in "Port" column (Default value: ; the Port number is predetermined by SOYAL for connection to the network) j. Select LAN BASE k. Click YES. Open Controller On/ Line window to check the device connection status: Well: controller successfully connected to PC. Not connected well: the following checks are required. Software: Parameters Settting: Door Number and Users Edit. After the 0Server Software connection, go click 8x Parameters Setting to set up E-V's door number a. Roll and select the Targe Node ID of E-V (The same as the dip-switch) b. Click "Read" to read back the parameter of E-V c. Click "E-V" button to set up Door Number a. d. Input the new Door Number of Slave Reader, which door number must be unique and non-repetitive Remarks: : Node ID fixed to while connected and Fixed to trigger the K Relay WG: Node ID fixed to 8 while connected and Fixed to trigger the K Relay CH: RS-8 Reader Node ID must be set up from 0 to 08 CH: RS-8 Reader Node ID must be set up as 09 to d. c. b.. Set up the Door Name on 0Client Software by clicking. Add/Delete/Modify Users in User Card Edit A. Door Name Edit. ; then, the even log will show Door Name while the user gets access. Required Information:.. Input user number. Input card code.. Select the access. mode. User name.. If necessary, add. Save Download info to controller