Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Similar documents
Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Model 2657A-LIM-3 LO Interconnect Module

HV-CS kv Edge Mount Triaxial Jack

Model 2380 Rack-Mount Kit

2260B-RMK-Series Rack Mount Kit

Model 7705 Control Module

Model 2380 Rack-Mount Kit

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Safety Precautions A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring.

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

Startup Software Quick Start Guide

Model GHz 50 Ohm RF Module

Model 7701 Multiplexer Module

Model Channel High Voltage Multiplexer Card

Models 2634B, 2635B, and 2636B System SourceMeter Instruments Quick Start Guide

Series 2600A System SourceMeter

Models 707B and 708B Switching Matrix

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Model 7700 Multiplexer Module

S530 Parametric Test System

2281S Precision DC Supply and Battery Simulator Quick Start Guide

Model 2440 Service Manual Rev. B / December 2004

KPXI 3U Instrument Chassis

Model 8101-PIV Test Fixture User s Guide. Overview. SMU Device holder (near latch) Two Leaded Part Plungers. PIV Device holder (near hinge)

Model 2450 Interactive SourceMeter Instrument

Series 3700 Screw Terminal Assemblies Installation Instructions

Model 2701 Ethernet-Based DMM / Data Acquisition System

Model DAQ6510 Quick Start Guide

Model 2700 Multimeter/Data Acquisition System Service Manual

Series 3700 System Switch/Multimeter

Model 2000-SCAN Scanner Card

Model DAQ6510 Data Acquisition and Multimeter System

Model kw Pulse Mode Interactive

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

* * Agilent Power Distribution Unit (PDU) Installation Guide

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Mini Digital Multimeter

Mini Digital Multimeter

Model /2-Digit Resolution Digital Multimeter

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

PCT2000. User Manual. Precision current transducer 2000 A

POCKET MULTIMETER Model No: MM18

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

DM3058/DM3058E Digital Multimeter

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

CMSA-100 Manual. Cinema Media Server Automation

Installation Job Aid for Ethernet Routing Switch 5900 Series

Autoranging True RMS Multimeter User Manual

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

User Guide True RMS Multimeter Extech EX205T

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Model 2001 Multimeter

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

9040/9040UK. Users Manual. Phase Rotation Indicator

2016 SIGLENT TECHNOLOGIES CO.,LTD

Line Impedance Stabilization Network (LISN)

G5 PDU Installation Guide

Agilent Technologies E5385A 100-Pin Probe

Digital ac/dc (24V) Input Module

Installation Job Aid for Ethernet Routing Switch 3600 Series

AutoRanging Digital MultiMeter

Model 2010 Multimeter Service Manual Rev. D / October 2003

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

OPERATING INSTRUCTION

700 Series 200 Amp Clamp Meters

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

MODEL 805 USER MANUAL

Replacing the Power Supply

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

User's Guide. Extech AM A AC Analog Clamp Meter

DS1000B Series Digital Oscilloscope

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

User's Guide. Digital Multimeter. Model MN42

HI-POT TESTER User Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Table of Contents Product Overview Before using the product Installation Procedure... 5

Advidia A-15 & A-35 Installation Manual

Mini Digital Multimeter Model MN15. User's Guide

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Series 2230G Triple-Channel Power Supplies

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

Mini Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Installation Instructions

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Transcription:

Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit contains a cable housing, an inverted plug, and a cable tie for strain relief. The cable housing is made up of two half-shells with cable outlets on three sides so that you can select which direction to wire your connections to the Model 2600-KIT rear-panel screw terminal. The inverted plug secures cables to pins for quick connection to the rear panel. Figure 1: Model 2460-KIT 071335400 / September 2014 *P071335400* 1

Model 2460-KIT Screw Terminal Connector Kit The maximum floating (common mode) voltage for a source-measure unit (SMU) is ±250 V. Exceeding this level may cause damage to the instrument and create a shock hazard. Using an external source to float a SMU could create a shock hazard in the test circuit. A shock hazard exists whenever >42 V peak is present in the test circuit. Appropriately rated cables or insulators must be provided for all connections to prevent access to live parts. When >42 V is present, the test circuit must be insulated for the voltage used or surrounded by a metal safety shield that is connected to a known protective earth (safety ground) and chassis ground. Each screw in the screw terminal connector can accommodate from 26 AWG (0.2 mm 2 ) to 12 AWG (2.5 mm 2 ) conductors. Parts list Model 2460-KIT parts list Quantity Part 1 8-pin connector 1 Cable housing (2 half-shells) 2 Cable outlet covers 1 Cable strain relief tie 2 Screws Characteristics Plug specifications Characteristic Insulation material group Specification I Nominal current/cross section 14 A / 2.5 mm 2 Maximum load current/cross section 14 A / 2.5 mm 2 Connection capacity UL and CSA approval data: Nominal voltage Current Conductor sizes 26 AWG to 12 AWG 300 V 14 A 26 AWG to 12 AWG 2 071335400 / September 2014

Model 2460-KIT Screw Terminal Connector Kit Assembly Turn off instrument power before installing the screw terminal connector to the instrument. Failure to remove power before installation may cause personal injury or death from electrical shock. To assemble the kit: 1. Determine your wiring requirements and pinouts. 2. Split the cable housing into upper and lower halves. 3. Thread wire and cabling into housing through one of the cable outlets. 4. Connect wires to the inverted plug. 5. Insert the cable tie through the strain relief slots and fasten around the cables. 6. Install the cable outlet covers in the unused cable outlets. 7. Snap housing halves together. 8. Insert the and tighten screws in the screw holes on the other side of the cable housing. 9. Plug assembled Model 2460-KIT into the Model 2460 rear-panel screw terminal. The following figure shows the pin connections for the Model 2460 rear-panel screw terminal. Figure 2: Model 2460 screw terminal pinouts 071335400 / September 2014 3

Safety precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some instruments and accessories would normally be used with nonhazardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before using the product. Refer to the user documentation for complete product specifications. If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. The types of product users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the instrument. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it operating properly, for example, setting the line voltage or replacing consumable materials. Maintenance procedures are described in the user documentation. The procedures explicitly state if the operator may perform them. Otherwise, they should be performed only by service personnel. Service personnel are trained to work on live circuits, perform safe installations, and repair products. Only properly trained service personnel may perform installation and service procedures. Keithley Instruments products are designed for use with electrical signals that are measurement, control, and data I/O connections, with low transient overvoltages, and must not be directly connected to mains voltage or to voltage sources with high transient overvoltages. Measurement Category II (as referenced in IEC 60664) connections require protection for high transient overvoltages often associated with local AC mains connections. Certain Keithley measuring instruments may be connected to mains. These instruments will be marked as category II or higher. Unless explicitly allowed in the specifications, operating manual, and instrument labels, do not connect any instrument to mains. Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fixtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30 V RMS, 42.4 V peak, or 60 VDC are present. A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring. Operators of this product must be protected from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from every connection point. In some cases, connections must be exposed to potential human contact. Product operators in these circumstances must be trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or above 1000 V, no conductive part of the circuit may be exposed. Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance-limited sources. NEVER connect switching cards directly to AC mains. When connecting sources to switching cards, install protective devices to limit fault current and voltage to the card. Before operating an instrument, ensure that the line cord is connected to a properly-grounded power receptacle. Inspect the connecting cables, test leads, and jumpers for possible wear, cracks, or breaks before each use. When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input power disconnect device must be provided in close proximity to the equipment and within easy reach of the operator. For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jumpers, installing or removing switching cards, or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) ground. Always make measurements with dry hands while standing on a dry, insulated surface capable of withstanding the voltage being measured. 4 071335400 / September 2014

For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be impaired. Do not exceed the maximum signal levels of the instruments and accessories, as defined in the specifications and operating information, and as shown on the instrument or test fixture panels, or switching card. When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. Chassis connections must only be used as shield connections for measuring circuits, NOT as protective earth (safety ground) connections. If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use of a lid interlock. If a screw is present, connect it to protective earth (safety ground) using the wire recommended in the user documentation. The symbol on an instrument means caution, risk of danger. The user must refer to the operating instructions located in the user documentation in all cases where the symbol is marked on the instrument. The symbol on an instrument means caution, risk of electric shock. Use standard safety precautions to avoid personal contact with these voltages. The symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. The symbol indicates a connection terminal to the equipment frame. If this symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be properly disposed of according to federal, state, and local laws. The WARNING heading in the user documentation explains dangers that might result in personal injury or death. Always read the associated information very carefully before performing the indicated procedure. The CAUTION heading in the user documentation explains hazards that could damage the instrument. Such damage may invalidate the warranty. Instrumentation and accessories shall not be connected to humans. Before performing any maintenance, disconnect the line cord and all test cables. To maintain protection from electric shock and fire, replacement components in mains circuits including the power transformer, test leads, and input jacks must be purchased from Keithley Instruments. Standard fuses with applicable national safety approvals may be used if the rating and type are the same. Other components that are not safety-related may be purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through Keithley Instruments to maintain accuracy and functionality of the product). If you are unsure about the applicability of a replacement component, call a Keithley Instruments office for information. To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, the board should be returned to the factory for proper cleaning/servicing. Safety precaution revision as of January 2013. 071335400 / September 2014 5