Series 3700 Screw Terminal Assemblies Installation Instructions

Similar documents
Model 7705 Control Module

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Replacing the Power Supply

Model 3750 Multifunction I/O Card

Model 3724 Dual 1x30 FET Multiplexer Card

*E * E E0606

Model GHz 50 Ohm RF Module

Model 2380 Rack-Mount Kit

SCSI Cable Installation Instructions

Model Channel High Voltage Multiplexer Card

Model 2657A-LIM-3 LO Interconnect Module

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 2380 Rack-Mount Kit

Model 7701 Multiplexer Module

G12/G12x USER S MANUAL

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Power Supply and Fan Module Installation

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

2260B-RMK-Series Rack Mount Kit

WARNING ELECTRICAL SHOCK HAZARD

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

HC900 Controller. Controller CPU and Scanner Module Installation and Replacement

PACSystems* RX3i IC695ACC650

Oracle <Insert Picture Here>

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Model 8101-PIV Test Fixture User s Guide. Overview. SMU Device holder (near latch) Two Leaded Part Plungers. PIV Device holder (near hinge)

Perle MCR200 Installation Guide

Model 7700 Multiplexer Module

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Installing the Cisco SFS 3504 Server Switch

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Removal and Installation8

2U, 4U, and 7U Systems

System Storage EXP3000 Rack Installation Instructions

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

PC9/P9 CPU Card Replacement

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Rack Installation Instructions

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

XCM8800 PSU Cover. Installation Guide. 350 East Plumeria Drive San Jose, CA USA. May v1.0

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

Installing a Power over Ethernet injector

Installing and Upgrading Memory and Virtual Private Network Modules

Removal and Replacement of the Serrano and Corsica Boards

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

IntelliVue Patient Monitors

E2460GS Oscilloscope Upgrade Kit

HP ProLiant DL165 G7 Server

Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HV-CS kv Edge Mount Triaxial Jack

TRC-190 User s Manual

and above (Standard) and above (Option 74) A14 Replacement (Display Module Subassembly w/touch Panel) VM700T

7403 K321. Display Wall Mount. Kit Instructions. Issue A

Removing and Installing the ISA and the ISM

E1135C PDU and Pod Upgrade Procedure

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

Installing the PSU for the S50 and S50N

Installation Job Aid for Ethernet Routing Switch 5900 Series

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Contivity Extranet Switch Installing Hardware Options Guide

Installation Instructions

PS/IO Circuit Board Retrofit

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Pro-Flo System Digital Controller EPROM Upgrade

Installing a Network Module

Removing and Replacing Parts

Tower to Rack and Rack to Tower System Conversion Guide

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum performance and

Upgrading LVDS Cables Instruction Sheet

TRC-190 User s Manual

TLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions

TrendView recorders - Installation Instruction

TDM To MiniMech conversion ProceDure

PC9/P9 Floppy Drive Replacement

Allen-Bradley Drives

MODIFYING THE ACS355 UL TYPE 4X FOR MXXX OPTIONS

SCXI-1345 Shielded Cable

RSA5100B Series Real-Time Signal Analyzers RSA5BUP Option 300 High Performance Real Time Upgrade Instructions

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

Ethernet Adapter Installation Instructions

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Dell Alienware 13 R3 Heat-Sink Assembly

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Safety Precautions A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring.

Written By: Teren Wallace

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

You need the following to set up and use your terminal block:

Managing Individual Components

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

hp uninterruptible power system r12000 xr models installation instructions

Transcription:

Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling and installation instructions for the Keithley Instruments Series 3700 System Switch/Multimeter screw terminal assemblies. Additional pin-out and connection information is included on the Product Information CD-ROM that came with your instrument, or in the documentation provided with your Series 3700 card. If you have any questions after reviewing this information, please contact your local Keithley Instruments representative or call Keithley Instruments corporate headquarters (toll-free inside the U.S. and Canada only) at 1-888-KEITHLEY (1-888-534-8453), or from outside the U.S. at +1-440-248-0400. For worldwide contact numbers, visit our website at www.keithley.com. WARNING The following information is intended for qualified service personnel. Do not make connections unless qualified to do so. To prevent electric shock that could result in serious injury or death, observe the following safety precautions: Before removing or installing a card in the mainframe, make sure the mainframe is turned off and disconnected from line power. Before making or breaking connections, make sure power is removed from all external circuitry. Do not connect signals that may exceed the maximum specifications of the model or external wiring. Complete specifications for each card are included on the documentation that came with the card. Please check the Keithley Instruments website at 0www.keithley.com for the latest updates to the specifications. All wiring must be rated for the maximum voltage in the system. For example, if 300 V is applied to the backplane connector, all card wiring must be rated for 300 V. PA-955 Rev. E / April 2010 1

Available screw terminal assemblies Screw terminal assemblies available for use with Series 3700S cards include: Model Link to figure 3720-ST Figure 1 3721-ST Figure 2 3723-ST Figure 1 3723-ST-1 Figure 3 3724-ST Figure 1 3730-ST Figure 4 3731-ST Figure 4 3732-ST-C Figure 5 3732-ST-R Figure 6 3740-ST Figure 7 3750-ST Figure 8 Screw terminal assembly circuit diagrams The figures below depict a top-down view of the Series 3700 screw terminal assemblies. Models 3723-ST-1, 3730-ST, 3740-ST, and 3750-ST screw terminal assemblies have chassis ground connections ( ) for connecting a cable shield. 2 PA-955 Rev. E / April 2010

Figure 1: Models 3720-ST, 3723-ST, and 3724-ST screw terminal assemblies Figure 2: Model 3721-ST screw terminal assembly PA-955 Rev. E / April 2010 3

Figure 3: Model 3723-ST-1 screw terminal assembly Figure 4: Models 3730-ST and 3731-ST screw terminal assembly 4 PA-955 Rev. E / April 2010

Figure 5: Model 3732-ST-C screw terminal assembly The Model 3732-ST-C screw terminal assembly is labeled to show the correct connections for the default quad 4x28 configuration. Insertable overlays are provided with the screw terminal assembly that show the correct wiring for the dual 4x56, single 4x112, dual 4x18 (2-pole), and single 4x56 (2-pole) configurations. For additional information about using the Model 3732 card and available accessories, refer to the Model 3732 Quad 4x28 Reed Relay Matrix Card Connection Information (part number PA-1021) document that came with your Model 3732 card. You can also download the document from www.keithley.com. PA-955 Rev. E / April 2010 5

Figure 6: Model 3732-ST-R screw terminal assembly The Model 3732-ST-R screw terminal assembly is labeled to show the correct connections for the dual 8x28 configuration. Insertable overlays are provided with the screw terminal assembly that show the correct wiring for the single 16x28 and single 8x28 (2-pole) configurations. For additional information about using the Model 3732 card and available accessories, refer to the Model 3732 Quad 4x28 Reed Relay Matrix Card Connection Information (part number PA-1021) document that came with your Model 3732 card. You can also download the document from www.keithley.com. 6 PA-955 Rev. E / April 2010

Figure 7: Model 3740-ST screw terminal assembly Figure 8: Model 3750-ST screw terminal assembly PA-955 Rev. E / April 2010 7

Screw terminal assembly installation and removal instructions The following figures show how to connect a Series 3700 screw terminal assembly to the Series 3700 System Switch / Multimeter and installed Series 3700 cards. WARNING Before using a screw terminal assembly with an installed Series 3700 card, verify that the card is properly installed in the Series 3700 mainframe, and the mounting screws are tightly fastened. If the mounting screws are not properly connected, an electrical shock hazard may be present. For Series 3700 card installation instructions, refer to the Series 3700 Quick Start Guide (part number 3700S-903-01), located on the Product Information CD-ROM that came with your Series 3700 product. To install a Series 3700 screw terminal assembly: 1. Remove the top cover of the screw terminal assembly (see Figure 9): a. Loosen the slotted captive screws on the top cover. b. Slide the top cover away from the retaining tab. Figure 9: Removing the screw terminal assembly top cover 8 PA-955 Rev. E / April 2010

2. Wire the screw terminal assembly circuit board: CAUTION It is not necessary to remove a circuit board from its enclosure to wire the screw terminal assembly. Avoid handling circuit board surfaces and terminal blocks, because contaminants from hands may degrade the screw terminal assembly's performance. a. For screw terminal assemblies that include insertable overlays, select the correct overlay for the configuration you are using and press it into place inside the screw terminal assembly. b. As shown in Figure 10, route your wiring through the slots in the rear of the screw terminal assembly and connect it to the proper wiring terminals (refer to the documentation supplied with your switch card for proper connection information). Figure 10: Routing and securing cables with ties c. When all wires have been connected, use small cable ties to secure the wires and provide strain relief, as shown in Figure 10. Pass the cable tie in and out of the small holes in the base of the screw terminal assembly and around your wiring before pulling the cable tie tight. 3. When you have finished wiring the screw terminal assembly circuit board, reinstall the top cover on the screw terminal assembly (see Figure 11): a. Align the top cover with the circuit board. b. Slide the cover forward and beneath the retaining tab. c. Fasten the two slotted captive screws. PA-955 Rev. E / April 2010 9

Figure 11: Installing the screw terminal assembly top cover 4. After removing all power from the Series 3700 instrument, ensure that the mounting screws on the installed Series 3700 card are secure (see Figure 12). Figure 12: Check Series 3700 card mounting screws 5. Align the screw terminal assembly D-sub connectors with the connectors on the installed Series 3700 card (see Figure 13), and press to seat the D-sub connectors. 6. Turn the knob on the screw terminal assembly clockwise (see Figure 13) until it is firmly engaged (you may need to use a slotted screwdriver to tighten the knob). CAUTION Do not tighten the screws too much, because this will damage the card. 10 PA-955 Rev. E / April 2010

Figure 13: Connecting the screw terminal assembly To use more than two Series 3700 screw terminal assemblies in a rack-mount installation, use the terminal support bracket included in the Model 4288-10 Rear Support Mount Kit. For more information about the rack-mount kit, refer to Keithley Instruments documentation titled Model 3706 Rack Mount Kit (part number PA-953), available on the Keithley Instruments website at www.keithley.com. To remove a screw terminal assembly from an installed Series 3700 card: To remove a screw terminal assembly from a Series 3700 instrument, you will perform the installation steps described above in reverse order (see enumerated steps below). 1. Remove all power from the Series 3700 instrument. 2. Turn the knob on the screw terminal assembly counter-clockwise until it is completely disengaged (you may need to use a slotted screwdriver to loosen the knob). 3. Pull the screw terminal assembly away from the Series 3700 card D-sub connectors. 4. Remove the top cover of the screw terminal assembly: a. Loosen the slotted captive screws on the top cover. b. Slide the top cover away from the retaining tab. 5. Remove the wiring on the screw terminal assembly. PA-955 Rev. E / April 2010 11