CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW The indirect evaporative free-cooling Air Handling Unit
Flexible & Efficient 11 sizes from 30 kw up to 520 kw to fit your needs with maximum efficiency Typical ppue between 1.02&1.10 The CyberHandler2 offers you a wide range of capacities, from 30 kw to 520 kw, in 11 different sizes allowing you to find the best compromise cost/efficiency according to your specific requirements. Each size will be an optimized and customized solution that perfectly fit to your installation requirements with the maximum efficiency and flexibility. With an high efficient indirect evaporative free-cooling design and using the industry state-of-the-art components the CyberHandler2 minimizes the running costs and achieve ppue s down to 1,02. The unique STULZ C7000 controller specially designed for precision control of mission-critical environments, with a proven track record of success within this industry, makes this product the most energy efficient trusted option in the market. Operation Modes & Benefits 120 140 35 100 30 0.030 3 operation modes based on ambient air temperatures: 0 /5 0 40 20 15 10 Dry Mode 60 20 80 25 Top - Up Mode Wet Mode 0.025 0.020 0.015 0.010 0.005 Dry Mode (free-cooling only): Adiabatics OFF Mechanical Cooling OFF Wet Mode (Adiabatic): Adiabatics ON Mechanical Cooling OFF Top-Up Mode (Mix Mode): Adiabatics ON Mechanical Cooling ON -5 0-10 5 10 15 20 25 30 35 40 45 50 55 0.000 The benefits of the indirect evaporative cooling: Outdoor contamination free Evaporative cooling extends indirect free-cooling operation all year round Unbeatable energy efficiency levels with ppues in the range of 1.02 1.10 Lower total cost of ownership (TCO): reduced CAPEX, OPEX, maintenance, infrastructure costs, etc Internal white space is reduced to a minimum, as the unit is installed externally Simplified installation: easier management of power cabling, pipes and water, not needed inside the white space Downsizing of the electrical infrastructure allows savings in CAPEX of 6-8% Faster return of investment
Installation Configurations 2 configurations available to adapt to your installation requirements Wall Configuration SH/RH * In this configuration the horizontal path of the IT room supply and return air allow the units to be installed directly in the wall of the building in a perimeter distribution. * SH: Supply Horizontal RH: Return Horizontal Roof Configuration SB/RB * This configuration allows the supply and return air to enter directly into the IT Room ceiling. No ductwork is needed on the roof. * SB: Supply Bottom RB: Return Bottom
Cooling Configurations Indirect evaporative free-cooling The ideal solution when the outdoor ambient conditions are suitable to reach the room supply temperature set point without the need of additional mechanical cooling. Only the adiabatic free-cooling system is enough to achieve the required cooling capacity. Indirect evaporative free-cooling with Top-Up integrated DX cooling system An integrated DX Top-Up cooling system helps the Air Handling Unit to achieve the required cooling capacity when the extreme outdoor ambient conditions are reached. The complete DX system (evaporator/ compressor/condenser) is inside the unit. The top-up DX system can reach up to 30% of the total required cooling capacity.
Indirect evaporative free-cooling with CW Coil Top-Up/Redundant cooling In case of extreme outdoor ambient conditions, the adiabatic cooling system is complemented by an integrated chilled water coil connected to a remote chiller. Options for the full CW coil redundancy or top-up are available. Indirect evaporative free-cooling with redundant DX cool. system In this configuration the Air Handling Unit is equipped with a DX coil (evaporator and compressors) which connects to an outdoor condensing unit allowing the system to reach 100% redundancy only with the DX system.
Components Overview Mechanical cooling options Chilled water coil (external chiller) DX coil (external condensor) Integrated DX cooling system (top-up) Compressor technology The latest EC compressor scroll inverter technology Additional tandem scroll compressors for higher capacities Maximum efficiency at partial loads Fans Exhaust Air Plug fan technology Latest technology of high efficient EC motors Reduce the noise level Outdoor or Air Filters Eurovent certified Meet the standard EN779:2012 Low pressure drop design Available in different classes (G4, M5, F7 and F9) Controller STULZ C7000 State-of-the-art intelligent control for IT cooling systems Designed specifically for precision control of mission-critical environments In-house development of hardware and software.
Air-to-air plate heat exchangers 100 % aluminium, epoxy painted, extra sealed 100% indirect heat recovery Eurovent certified Excellent relation efficiency vs pressure drop Double PHX for higher cooling recovery Return Air Dampers Supply Air 100 % aluminium and plastics (no corrosion issues) Low pressure drop design Different leakage classes available Special fire and smoke dampers (as optional) Water spray nozzles Full cone stainless steel nozzles Guarantees a full shower of the plate heat exchanger Non-clogging design Allows the use of demineralized water Water Pump High efficiency stainless steel circulation pump Allows the use of demineralized water Low pressure system Redundant pump as optional
Selection Tool The CyberHandler2 Select is a powerful software tool specially designed to allow an easy and friendly experience trough the selection of each Air Handling Unit. The user-friendly interface guides you through the optimization and customization of the unit that best fits the project requirements. As outputs the CyberHandler2 Select is able to deliver you the following documentation: Technical specification sheets 2D Drawings 3D image Quotation Life Cycle Cost (LCC) calculation ppue calculation (inbuilt the ASHRAE Weather Data Viewer version 5.0) The complete solution The CyberHandler2 is more than a product, we have a full range of services available to offer you a turnkey solution for the data center cooling: Life Cycle Cost/ ppue Calc. RO Water Treat. Syst. Warranty CyberHandler2 Commissioning Maintenance Software tools for the calculation of the Life Cycle Cost/pPUE Reverse Osmosis (RO) water treatment system Commissioning Maintenance Warranty
C7000 Controller C 7000 Electronic Controller: Intelligent Control for IT Cooling Systems Designed specifically for precision control of mission-critical environments Energy-efficient control concepts onboard (CW standby management, raised-floor pressure management, Indirect Dynamic Free Cooling) Preservation of parameters during firmware updates Onboard protocol Modbus RTU (customizing Modbus data point list) Freely configurable digital alarm inputs Integrated data logger Internal Modbus component communication bus Hardware periphery check after boot sequence The following BMS protocols are supported: BACnet IP, BACnet MS/TP, Modbus TCP, and LonWorks WIB 8000: The All-in-One Web Interface for Precision Air-Conditioning Systems. The WIB 8000 is user-friendly and highly functional, and it offers easy data exchange and monitoring with global adaptability. Functions and Monitoring Alert information via e-mail to up to five recipients Ongoing retrieval of data from the controller Monitoring of up to 32 units via Web browser Ethernet port Bus-independent zone operation Easy connection to existing building management system User-Friendly Works via HTTP and SNMP in parallel No JavaScript, no cookies Easy and quick configuration via Web page Easy to install and suitable for retrofitting (only one component to install!)
Main Features at a glance Cooling range from 30 kw to 520 kw 11 sizes Ready for roof and wall installation The best casing leak classification according to the standard EN1886 (L1/L1) Designed for minimum pressure losses STULZ C7000 controller designed especially for precision control of mission-critical environments Easy access for maintenance Several filter classes available: G4, M5, F7 and F9 Designed to fit standard transportation Flexible modular installation 3 cooling systems in 1: - Indirect free-cooling - Indirect evaporative cooling - Mechanical cooling (as top-up or redundancy) Customize it Customize the CyberHandler2 to your requirements with a wide range of options Dual power supply with automatic or manual switchover Ultrasonic humidifiers Fresh air damper for CO2 control Outdoor installation Damper (ambient side and DC room return) Silencers FAT Control systems UPS backed Fire and smoke dampers (Data Hall side) Different filter classes according the EN779: M5, F7, F9 RO water treatment system Anti-frost control Redundant adiabatic water pump Different power supply
Services on your doorstep STULZ is a global company with headquarters in Hamburg, Germany, 19 subsidiaries, 7 production sites and sales and service partners in more than 140 countries. In 1971 we began specializing in the development an production of precision air conditioning units and chi for data centers. That s a wealth of experience gathere over 40 years from many thousands of projects that we ve implemented worldwide. Technical development from Germany We put a great deal of experience and innovative spirit into our air conditioning systems. Engineers, specialist departments and sales employees work closely together and are involved through all stages of development, all the way to the finished product. We brook no compro - mise where the efficiency of our products is concerned, and cost-effective operation is at the heart of our endeavors. Test to your specifications In our state-of-the-art, 700-square-meter Test Center with its various climate chambers, we can perform a variety of tests on precision air conditioning systems and chillers. If you decide to purchase a STULZ solution, you can book a witness test in our Test Center. This allows you to have the desired air conditioning system tested for compliance with your exact specifications, creating transparency and providing you with information about the system s performance and energy consumption.