CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Similar documents
Air Handling Units. With Intelligence

Precision Cooling Mission Critical Air Handling Units

CyberHandler 2 The Indirect Evaporative Free Cooling Air Handling Unit

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Ecoflair Air Economizers

Indirect Adiabatic and Evaporative Data Center Cooling

Indirect Adiabatic and Evaporative Data Centre Cooling

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

Aquaflair. BREC/F and BCEC/F kw

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

HIGH EFFICIENCY Central Chiller

The new generation of dedicated HVAC drives

Case Study The University of Warwick

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

IT Air Conditioning Units

AireFlow kW DX AIR. Data Centre Cooling Product of the Year. Indirect Adiabatic AHU

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Industry leading low energy evaporative fresh air cooling.

Total Modular Data Centre Solutions

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Ecotel Free Cool 5-15kW

Reducing Data Center Cooling Costs through Airflow Containment

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Control systems. Efficient room control

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

Rack cooling solutions for high density racks management, from 10 to 75 kw

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Liebert PDX from 15 to 120 kw

Close-coupled cooling

ASHRAE IRELAND HVAC FOR DATA CENTRES. Michael Geraghty Building Services Engineer (DipEng) Company owner and managing director

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Data Center Optimized Controls

Liebert PDX from 15 to 120 kw

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Thermal management. Thermal management

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Liquid Cooling Package LCP Cooling Systems

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Munters Data Center Cooling Solutions. Simon Young & Craig MacFadyen Munters Data Centers

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

Trane Cold Generator TM. Scroll Chillers. Comfort and Process Cooling Solutions

M+W Group s Visionary Delta Datacenter

Efficiency of Data Center cooling

GP SERIES Packaged Chillers

Blue e+ chillers with the principle

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Introducing the Heat Wheel to the Data Center

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

Liquid Cooling Package LCP Cooling Systems

DESCRIPTION OF MODBUS CONNECTION

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert. DCL up to 35 kw. Modular Rack Cooling

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

How Green can you go?

SmoothAir Modular Precision Cooling

Precision Cooling. Precision Cooling Advantages

INNOVATE DESIGN APPLY.

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment

INNOVATE DESIGN APPLY.

Trailblazer AGZ-E air-cooled scroll chillers

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

RiMatrix S Make easy.

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

FEATURES AND BENEFITS. Installation and operation. Controller

ENCLOSURE HEAT DISSIPATION

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

18 th National Award for Excellence in Energy Management. July 27, 2017

CASE STUDIES ENERGY EFFICIENT DATA CENTRES

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

DATACENTER CAMPUS FRANKFURT. Plan for Every Second

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

How to Increase Data Center Efficiency

Transcription:

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW The indirect evaporative free-cooling Air Handling Unit

Flexible & Efficient 11 sizes from 30 kw up to 520 kw to fit your needs with maximum efficiency Typical ppue between 1.02&1.10 The CyberHandler2 offers you a wide range of capacities, from 30 kw to 520 kw, in 11 different sizes allowing you to find the best compromise cost/efficiency according to your specific requirements. Each size will be an optimized and customized solution that perfectly fit to your installation requirements with the maximum efficiency and flexibility. With an high efficient indirect evaporative free-cooling design and using the industry state-of-the-art components the CyberHandler2 minimizes the running costs and achieve ppue s down to 1,02. The unique STULZ C7000 controller specially designed for precision control of mission-critical environments, with a proven track record of success within this industry, makes this product the most energy efficient trusted option in the market. Operation Modes & Benefits 120 140 35 100 30 0.030 3 operation modes based on ambient air temperatures: 0 /5 0 40 20 15 10 Dry Mode 60 20 80 25 Top - Up Mode Wet Mode 0.025 0.020 0.015 0.010 0.005 Dry Mode (free-cooling only): Adiabatics OFF Mechanical Cooling OFF Wet Mode (Adiabatic): Adiabatics ON Mechanical Cooling OFF Top-Up Mode (Mix Mode): Adiabatics ON Mechanical Cooling ON -5 0-10 5 10 15 20 25 30 35 40 45 50 55 0.000 The benefits of the indirect evaporative cooling: Outdoor contamination free Evaporative cooling extends indirect free-cooling operation all year round Unbeatable energy efficiency levels with ppues in the range of 1.02 1.10 Lower total cost of ownership (TCO): reduced CAPEX, OPEX, maintenance, infrastructure costs, etc Internal white space is reduced to a minimum, as the unit is installed externally Simplified installation: easier management of power cabling, pipes and water, not needed inside the white space Downsizing of the electrical infrastructure allows savings in CAPEX of 6-8% Faster return of investment

Installation Configurations 2 configurations available to adapt to your installation requirements Wall Configuration SH/RH * In this configuration the horizontal path of the IT room supply and return air allow the units to be installed directly in the wall of the building in a perimeter distribution. * SH: Supply Horizontal RH: Return Horizontal Roof Configuration SB/RB * This configuration allows the supply and return air to enter directly into the IT Room ceiling. No ductwork is needed on the roof. * SB: Supply Bottom RB: Return Bottom

Cooling Configurations Indirect evaporative free-cooling The ideal solution when the outdoor ambient conditions are suitable to reach the room supply temperature set point without the need of additional mechanical cooling. Only the adiabatic free-cooling system is enough to achieve the required cooling capacity. Indirect evaporative free-cooling with Top-Up integrated DX cooling system An integrated DX Top-Up cooling system helps the Air Handling Unit to achieve the required cooling capacity when the extreme outdoor ambient conditions are reached. The complete DX system (evaporator/ compressor/condenser) is inside the unit. The top-up DX system can reach up to 30% of the total required cooling capacity.

Indirect evaporative free-cooling with CW Coil Top-Up/Redundant cooling In case of extreme outdoor ambient conditions, the adiabatic cooling system is complemented by an integrated chilled water coil connected to a remote chiller. Options for the full CW coil redundancy or top-up are available. Indirect evaporative free-cooling with redundant DX cool. system In this configuration the Air Handling Unit is equipped with a DX coil (evaporator and compressors) which connects to an outdoor condensing unit allowing the system to reach 100% redundancy only with the DX system.

Components Overview Mechanical cooling options Chilled water coil (external chiller) DX coil (external condensor) Integrated DX cooling system (top-up) Compressor technology The latest EC compressor scroll inverter technology Additional tandem scroll compressors for higher capacities Maximum efficiency at partial loads Fans Exhaust Air Plug fan technology Latest technology of high efficient EC motors Reduce the noise level Outdoor or Air Filters Eurovent certified Meet the standard EN779:2012 Low pressure drop design Available in different classes (G4, M5, F7 and F9) Controller STULZ C7000 State-of-the-art intelligent control for IT cooling systems Designed specifically for precision control of mission-critical environments In-house development of hardware and software.

Air-to-air plate heat exchangers 100 % aluminium, epoxy painted, extra sealed 100% indirect heat recovery Eurovent certified Excellent relation efficiency vs pressure drop Double PHX for higher cooling recovery Return Air Dampers Supply Air 100 % aluminium and plastics (no corrosion issues) Low pressure drop design Different leakage classes available Special fire and smoke dampers (as optional) Water spray nozzles Full cone stainless steel nozzles Guarantees a full shower of the plate heat exchanger Non-clogging design Allows the use of demineralized water Water Pump High efficiency stainless steel circulation pump Allows the use of demineralized water Low pressure system Redundant pump as optional

Selection Tool The CyberHandler2 Select is a powerful software tool specially designed to allow an easy and friendly experience trough the selection of each Air Handling Unit. The user-friendly interface guides you through the optimization and customization of the unit that best fits the project requirements. As outputs the CyberHandler2 Select is able to deliver you the following documentation: Technical specification sheets 2D Drawings 3D image Quotation Life Cycle Cost (LCC) calculation ppue calculation (inbuilt the ASHRAE Weather Data Viewer version 5.0) The complete solution The CyberHandler2 is more than a product, we have a full range of services available to offer you a turnkey solution for the data center cooling: Life Cycle Cost/ ppue Calc. RO Water Treat. Syst. Warranty CyberHandler2 Commissioning Maintenance Software tools for the calculation of the Life Cycle Cost/pPUE Reverse Osmosis (RO) water treatment system Commissioning Maintenance Warranty

C7000 Controller C 7000 Electronic Controller: Intelligent Control for IT Cooling Systems Designed specifically for precision control of mission-critical environments Energy-efficient control concepts onboard (CW standby management, raised-floor pressure management, Indirect Dynamic Free Cooling) Preservation of parameters during firmware updates Onboard protocol Modbus RTU (customizing Modbus data point list) Freely configurable digital alarm inputs Integrated data logger Internal Modbus component communication bus Hardware periphery check after boot sequence The following BMS protocols are supported: BACnet IP, BACnet MS/TP, Modbus TCP, and LonWorks WIB 8000: The All-in-One Web Interface for Precision Air-Conditioning Systems. The WIB 8000 is user-friendly and highly functional, and it offers easy data exchange and monitoring with global adaptability. Functions and Monitoring Alert information via e-mail to up to five recipients Ongoing retrieval of data from the controller Monitoring of up to 32 units via Web browser Ethernet port Bus-independent zone operation Easy connection to existing building management system User-Friendly Works via HTTP and SNMP in parallel No JavaScript, no cookies Easy and quick configuration via Web page Easy to install and suitable for retrofitting (only one component to install!)

Main Features at a glance Cooling range from 30 kw to 520 kw 11 sizes Ready for roof and wall installation The best casing leak classification according to the standard EN1886 (L1/L1) Designed for minimum pressure losses STULZ C7000 controller designed especially for precision control of mission-critical environments Easy access for maintenance Several filter classes available: G4, M5, F7 and F9 Designed to fit standard transportation Flexible modular installation 3 cooling systems in 1: - Indirect free-cooling - Indirect evaporative cooling - Mechanical cooling (as top-up or redundancy) Customize it Customize the CyberHandler2 to your requirements with a wide range of options Dual power supply with automatic or manual switchover Ultrasonic humidifiers Fresh air damper for CO2 control Outdoor installation Damper (ambient side and DC room return) Silencers FAT Control systems UPS backed Fire and smoke dampers (Data Hall side) Different filter classes according the EN779: M5, F7, F9 RO water treatment system Anti-frost control Redundant adiabatic water pump Different power supply

Services on your doorstep STULZ is a global company with headquarters in Hamburg, Germany, 19 subsidiaries, 7 production sites and sales and service partners in more than 140 countries. In 1971 we began specializing in the development an production of precision air conditioning units and chi for data centers. That s a wealth of experience gathere over 40 years from many thousands of projects that we ve implemented worldwide. Technical development from Germany We put a great deal of experience and innovative spirit into our air conditioning systems. Engineers, specialist departments and sales employees work closely together and are involved through all stages of development, all the way to the finished product. We brook no compro - mise where the efficiency of our products is concerned, and cost-effective operation is at the heart of our endeavors. Test to your specifications In our state-of-the-art, 700-square-meter Test Center with its various climate chambers, we can perform a variety of tests on precision air conditioning systems and chillers. If you decide to purchase a STULZ solution, you can book a witness test in our Test Center. This allows you to have the desired air conditioning system tested for compliance with your exact specifications, creating transparency and providing you with information about the system s performance and energy consumption.