Fast iterative beam hardening correction based on frequency splitting in computed tomography

Similar documents
Accelerated quantitative multi-material beam hardening correction(bhc) in cone-beam CT

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

A new calibration-free beam hardening reduction method for industrial CT

DUE to beam polychromacity in CT and the energy dependence

Frequency split metal artifact reduction (FSMAR) in computed tomography

A new calibration-free beam hardening reduction method for industrial CT

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

ML reconstruction for CT

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Ch. 4 Physical Principles of CT

Scaling Calibration in the ATRACT Algorithm

Scatter Correction Methods in Dimensional CT

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Development of a multi-axis X-ray CT for highly accurate inspection of electronic devices

Iterative correction of beam hardening artifacts in CT.

A Comparative Study of Two Methods for the Correction of Beam Hardening Artifacts in X-ray Computed Tomography

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Iterative CT Reconstruction Using Curvelet-Based Regularization

Optimization of scanner parameters for dual energy micro-ct

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

Suitability of a new alignment correction method for industrial CT

Non-Stationary CT Image Noise Spectrum Analysis

Metal Streak Artifacts in X-ray Computed Tomography: A Simulation Study

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

Edge-Preserving Denoising for Segmentation in CT-Images

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

DUAL energy X-ray radiography [1] can be used to separate

Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT. y i Poisson I i (E)e R } where, b i

Digital Image Processing

Total Variation Regularization Method for 3D Rotational Coronary Angiography

Research Article An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization

The Near Future in Cardiac CT Image Reconstruction

Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences

Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising

Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

Towards full-body X-ray images

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS

Accelerated C-arm Reconstruction by Out-of-Projection Prediction

Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-arm CT

Carestream s 2 nd Generation Metal Artifact Reduction Software (CMAR 2)

Segmentation-Free Quasi-Newton Method for Polyenergetic CT Reconstruction

System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam CT Scanner

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Quality Guided Image Denoising for Low-Cost Fundus Imaging

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Metal artifacts reduction in x-ray CT based on segmentation and forward-projection

A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

CT vs. VolumeScope: image quality and dose comparison

FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION

Spectral CT reconstruction with an explicit photon-counting detector model: a one-step approach

AN X-ray system with a large area detector, such as is used

Whole Body MRI Intensity Standardization

Application of MCNP Code in Shielding Design for Radioactive Sources

Estimation of Missing Fan-Beam Projections using Frequency Consistency Conditions

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Enhanced material contrast by dual-energy microct imaging

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

Moving Metal Artifact Reduction for Cone-Beam CT (CBCT) Scans of the Thorax Region

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Cardiac Dual Energy CT: Technique

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Central Slice Theorem

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

High Performance GPU-Based Preprocessing for Time-of-Flight Imaging in Medical Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Medical Image Processing: Image Reconstruction and 3D Renderings

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Superiorized polyenergetic reconstruction algorithm for reduction of metal artifacts in CT images

Empirical dual energy calibration EDEC for cone-beam computed tomography

BME I5000: Biomedical Imaging

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Introduction to Biomedical Imaging

Translational Computed Tomography: A New Data Acquisition Scheme

Tomographic Reconstruction

Transcription:

Fast iterative beam hardening correction based on frequency splitting in computed tomography Qiao Yang a,b, Matthias Elter b, Ingo Schasiepen b, Nicole Maass b and Joachim Hornegger a,c a Pattern Recognition Lab, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany b Siemens AG, Healthcare Sector, Erlangen, Germany c School in Advanced Optical Technologies (SAOT), Erlangen, Germany ABSTRACT In computed tomography (CT), the nonlinear characteristics of beam hardening are due to the polychromaticity of X-rays, which severely degrade the CT image quality and diagnostic accuracy. The correction of beam hardening has been an active area since the early years of CT, and various techniques have been developed. Stateof-the-art works on multi-material beam hardening correction (BHC) are mainly based on segmenting datasets into different materials, and correcting the non-linearity iteratively. Those techniques are limited in correction effectiveness due to inaccurate segmentation. Furthermore, most of them are computationally intensive. In this study, we introduce a fast BHC scheme based on frequency splitting with the fact that beam hardening artifacts mainly contain in the low frequency components and take more iterations to be corrected in comparison with high frequency components. After low-pass filtering and correcting artifacts at down-sampled projections, an artifact reduced high resolution reconstruction will be obtained by incorporating the original edge information from the high frequency components. Evaluations in terms of correction accuracy and computational efficiency are performed using simulated and real CT datasets. In comparison to the BHC algorithm without frequency splitting, the proposed accelerated algorithm yields comparable results in correcting cupping and streak artifacts with tremendously reduced computational effort. We conclude that the presented framework can achieve a significant speedup while still obtaining excellent artifact reduction. This is a significant practical advantage for clinical as well as industrial CT. Keywords: Computed tomography, image reconstruction, beam hardening artifacts 1. MOTIVATION In computed tomography (CT), the polychromatic characteristic of X-rays leads to the attenuation of an homogeneous object being not proportional to the thickness of the object along the ray. When a polychromatic X-ray beam passes through objects, lower energy photons are more easily absorbed than the higher energy photons, resulting in so-called beam hardening phenomenon. Standard reconstruction techniques, such as filtered backprojection (FBP), are generally based on the assumption that the linear attenuation coefficient for a certain object is unique and that the logarithm of the measurement is the line integral of the attenuation coefficient. Therefore, if the energy dependence of the X-ray is not taken into account, reconstruction images will contain cupping and streak artifacts 1. To mitigate artifacts caused by beam hardening, numerous correction techniques have been proposed. The very first and common approach is to absorb the lower energy photons in the spectrum by physically pre-filtering the X-ray beams with thin metallic plates. Although the hardware filters limit the amount of beam hardening, the narrowed source spectrum with lower photon count also results in a decrease of the signal-to-noise ratio. State-of-the-art BHC approaches used in clinical CT are mainly based on water-equivalent calibration and can only efficiently correct datasets consisting of objects which have similar densities as water. Alvarez 2 proposed dual-energy correction which is capable to eliminate beam hardening artifacts. However, the major drawback of dual-energy lies in the requirement of sophisticated and expensive hardware calibration. Pre-correction is Send correspondence to Qiao Yang: qiao.yang@informatik.uni-erlangen.de

generally based on linearization procedures. 3 Here, the nonlinear measurement is fitted with polynomials as one assumes that all substances in the scanning plane have the same energy dependence. The post-processing techniques 4,5 start with a preliminary reconstruction, from which a material distribution is calculated. The distribution allows estimation of the hardening factor, thus the corrected reconstruction can be obtained by correcting the original projection images. Scientific researches for datasets consisting of multiple materials are often carried out by segmenting the datasets into different materials and correcting the non-linearity iteratively. A major limitation of these techniques is computational complexity which renders them unsuitable for practical usage 5,6,7. In this work, we employ the material decomposition approach from dual-energy model into standard single tube energy CT. By acquiring material distribution and density information for segmented volume, a polychromatic model can be obtained from combination of material density. Doing the segmentation that way is essential in order to obtain a high image quality because of the following reasons: a fast BHC algorithm based on frequency splitting. Frequency splitting techniques have been used in CT for various purposes such as image reconstruction 8, scatter correction 9 and metal artifact reduction 10. We employ this technique by low-pass filtering the original images to avoid aliasing during down- and up-sampling, and apply most of the BHC iterations to the down-sampled projection images to reduce the computational intensity. We organize the paper as follows: section 2 outlines the theoretical aspects of the proposed algorithm. The method has been evaluated for simulated and real X-ray CT data, which can be found in section 3. Finally, discussion and conclusion are presented in section 4. 2. METHODS In this section, we briefly introduce the framework of the accelerated iterative BHC using frequency splitting. A flowchart of the algorithm can be found in Fig. 1. The algorithm mainly can be divided into two parts: it is initialized by performing frequency splitting on original projection images to obtain low resolution images and an iterative scheme which corrects beam hardening artifacts on down-sampled images. It has to be noted that sampling errors may occur during the procedure, therefore, final refinement of the images has to be taken under consideration. 2.1 Frequency split The algorithm is based on the observation that beam hardening artifacts mainly appear in the lower frequency components of the image and cause more correction iterations than correction in high frequency components. Correcting beam hardening at down-scaled images will significantly limit the computational time but is still be able to preserve correction quality. A low-pass filter is applied to split the projections I into low frequency components I LF and high frequency components I HF. 2D Gaussian filters are applied with a fixed standard deviation to perform the split I u,v = 1 2πσ e u 2 +v 2 2σ 2. (1) Additional high frequency information would be lost during down-scaling process. Therefore, ideally, a filter which anticipates the frequency characteristics of beam hardening corresponds to the downscaling method could be chosen for better accuracy. 2.2 Segmentation Generally, when BHC approaches contain a segmentation step to distinguish different materials, the performance of the correction algorithms highly depends on the accuracy of that segmentation. However, the segmentation often suffer from the reconstruction artifacts. In this paper, a global thresholding method is used, but we would like to address that when more sophisticated segmentation strategies are applied, the efficiency of the correction method would be improved because of the decrease in number of iterations. Therefore, the major challenge for the correction is to obtain more precise segmentations, which is expected after the iterative reduction of beam hardening artifacts.

Figure 1: Flowchart for frequency splitting accelerated iterative beam hardening correction. 2.3 Beam hardening correction When X-ray beams traverse objects, the attenuation coefficients µ are dependent on material characteristics such as mass density ρ, atomic number Z, photon energy E, as well as intersection length s between X-ray beam and objects. According to Lambert-Beer s law, the attenuation of monochromatic X-ray beam i can be modeled as where I 0 is incident intensity and E 0 is monochromatic photon energy. I mono,i = I 0 e µ(ρ,z,e 0)ds i, (2) However, in practice X-rays are polychromatic, i.e., each photon is part of the polychromatic X-ray spectrum. When energy dependence of the attenuation coefficients µ = µ(ρ, Z, E) is taken into account, the exit intensity for the specific beam i can be expressed as I poly,i = where I 0 (E) is the X-ray source spectrum. Emax 0 I 0 (E)e µ(ρ,z,e)ds i de, (3) In our approach, the aim is to find correction factors α by simulating monochromatic and polychromatic projections α = I mono I poly. (4) With the measured X-ray intensities I original as reference, corrected intensities are calculated as follows: I correction = α I original. (5)

The smaller the difference between measured projections and corresponding simulated polychromatic intensity image I poly, the higher accuracy the correction factors have. A more detailed description of this BHC method was published in Yang et al. 11. Since the accuracy of segmentation results in the efficiency of correction, gradually improvement for both segmentation and beam hardening reduced reconstruction can be obtained iteratively. To derive a stop criterion for the iterations, we define the polychromatic model error ξ of the ith iteration to be the value of cost function Φ where Φ = 1 L L l=1 (I original poly,l I sim poly,l) 2. (6) L is the total number of projection rays. Given a threshold t [0; 1], the iteration process will be terminated when t < ξi + ξ i 1 ξ i 2. (7) + ξi 3 2.4 Corrected projection and further refinement The corrected downsampled projections are then upsampled to the original resolution projections. To avoid loss of information, the original high-frequency components I HF and the sampling inaccuracies ɛ due to interpolation need to be taken into account: I corrected = I HF + I ɛ + Icorrected. LF (8) The proposed method is based on the assumption that the beam hardening artifacts mainly appear in the low frequency components of the projections, which results in more iterations are needed in low frequency components than in high frequencies. After accelerated BHC iterations at downsampled images to reduce the artifacts in low frequencies, one or two final iterations at full resolution are expected to further improve correction accuracy and image quality. This is to compensate the distortions caused by the susceptibility changes at material edges which appear mainly in high frequency components. In this paper, two iterations with full resolution are applied for both simulated and real datasets for evaluation. 3. RESULTS AND DISCUSSION In order to investigate the effectiveness of the proposed algorithm, we applied the correction to both simulated and real data. Detailed setup parameters for each dataset are shown in Table 1. Table 1: Setup parameters Parameter Hip Prosthesis Phantom Multi-cylinders Tube voltage 120kVp 150kVp SOD(source object distance) 750mm 1200mm SDD(source detector distance) 800mm 1400mm Detector 512 512 1024 1024 Pixel size 0.4mm 0.4mm Volume 512 512 512 400 400 600 Voxel size 0.3mm 0.5mm

3.1 Simulation results The validity of the proposed algorithm is evaluated by using a simulated FORBILD hip prosthesis phantom 12. The correction operations were applied using a downsampling factor of two. Fig. 2 shows the FBP reconstruction of the hip prosthesis phantom, segmentation and the line profiles regarding to cupping and streak artifacts, respectively. We illustrate the results for original (iteration 0), intermediate (iteration 5) and final (iteration 11) iterations. From the reconstruction and corresponding line profiles along the central horizontal and vertical line, it can be observed that both cupping and streak artifacts have been strongly suppressed compared to non-corrected reconstruction. Due to the inaccuracy of the segmentation, over- and under- correction during iterations occur. For example, in the column of Fig. 2 which shows results from iteration 5, an over-correction of cupping artifacts occurred. This is mainly because misclassification of material will lead to errors in simulating different polychromatic characteristics. However, the results depict that our method is able to recover an accurate reconstruction image with precise segmentation, even though the initial segmentation is poor. The second row of Fig. 2 demonstrates the segmentation for the datasets which consists of three material classes(soft tissue, bone and metal implants). Clearly, gradual improvement of the segmentation image through successive iterations can be observed. From the results shown above, it can be seen that the initial segmentation suffers from reconstruction artifacts at the beginning. During the reducing of beam hardening artifacts, better segmentations can be obtained. Streaks Cupping Segmentation Reconstruction Figure 2: Simulation results from hip prosthesis phantom at original (Iter. 0), intermediate (Iter. 5) and final (Iter. 11) reconstruction, respectively. Iteration 1 to 9 were simulated with a down-sampling factor of 2, and two final iterations were carried out on full resolution images. First row: reconstruction of the phantom. Second row: segmentation. Third row: line profiles along center horizontal line in order to examine cupping artifacts. Bottom row: line profiles along center vertical line in order to examine streak artifacts between two high density prosthesis. Window settings (in terms of attenuation coefficient): level 0.08; window 0.15.

3.2 Experimental results A real X-ray projected multi-material dataset consisting of four cylinders (polyester, aluminum, steel, and copper) was further evaluated (see Table 1). Figure (3a) shows the central slice of the original reconstruction without BHC and the corresponding line profile. It can be observed that suffering from the existence of high density objects, the original reconstruction shows dark and bright streak artifacts and strong cupping. Moreover, segmentation faces a big challenge due to the similar dense objects which results in overlapping of gray value in histogram and streak distortions. Fig. (3b) and Fig. (3c) illustrate the reconstruction results from BHC applied on full resolution images and our accelerated algorithm, respectively. The correction with full resolution was carried with 12 iterations with stop criterion t = 0.78, while with frequency split method it stopped at 9th iteration with t = 0.75. A comparison of our proposed method with the high resolution BHC method indicates that our algorithm is equally effective in removing cupping artifacts. Further examination on reduction of streak artifacts is depicted with the red circle in the line profiles. It can be seen that the BHC algorithm has successfully reduced the streaks caused by beam hardening compared to reconstruction without correction. However, the proposed algorithm is slightly less effective than the BHC applied on full resolution images. The reason might be that part of the streak artifacts appear in the high-frequency components. 3.3 Computational intensity The BHC algorithm requires one forward and back projection for each iteration, which significantly hinder the computational speed. By taking most of the iterations at down-scaled images, our method can achieve computationally much less expensive. Theoretically, a down-sampling factor of two yields a reduction of the projection pixel number by factor of four and voxel number by a factor of eight. In our experiments, the running time of simulation dataset was 17.9% of the time cost by BHC with full resolution, and the real dataset achieved 21.2%. 4. CONCLUSION In this paper, we have presented a fast BHC algorithm based on frequency splitting. The corrected images can be obtained by iteratively correcting down-sampled images with low frequency, and later combining them with the original high-frequency images in order to lower the computation cost. The algorithm has been implemented for a 3D cone beam geometry, which be realized for practical usage. The results presented in this paper indicate that a successful reduction of beam hardening artifacts can be obtained even when the projections have been down-sampled, which proves our initial assumption. In addition, the algorithm has been compared to the full resolution BHC approach and the results yield similar effectiveness for correcting cupping and streak artifacts, but a significant reduction of computational intensity. Using the frequency splitting method enables the general capability of BHC approaches in low resolution images. However, in order to minimize the information loss in the high frequency components, it is necessary to apply full resolution correction at final steps.

(a) Reconstruction without BHC (b) BHC applied to full resolution images (c) BHC applied to images after frequency splitting Figure 3: Reconstruction results of real X-ray projected dataset consisting of copper, steel, aluminum and polyester cylinders, with correspondent line profiles. (3a): slice of original reconstruction without BHC. (3b): slice of reconstruction with BHC in high resolution. (3c): slice of reconstruction with proposed frequency splitting BHC algorithm. Window settings (in terms of attenuation coefficient): level 0.11; window 0.3. REFERENCES [1] Stonestrom, J. P., Alvarez, R. E., and Macovski, A., A framework for spectral artifact corrections in x-ray CT, IEEE Transactions on Biomedical Engineering 28, 128 141 (1981). [2] Alvarez, R. E. and Macovski, A., Energy-selective reconstructions in x-ray computerised tomography,

Physics in Medicine and Biology 21(5), 733 (1976). [3] de Casteele, E. V., Model-based approach for Beam Hardening Correction and Resolution Measurements in Microtomography, PhD thesis, University Antwerpen (2004). [4] Krumm, M., Kasperl, S., and Franz, M., Reducing non-linear artifacts of multi-material objects in industrial 3d computed tomography, NDT & E International Vol 41, No 4, pp 242251 (2008). [5] Gompel, G. V., Slambrouck, K. V., Defrise, M., Batenburg, K. J., de Mey, J., Sijbers, J., and Nuyts, J., Iterative correction of beam hardening artifacts in CT, Medical Physics 38(S1), S36 S49 (2011). [6] Herman, G., Correction for beam hardening in computed tomography, Physics in Medicine and Biology 24, 81 (1979). [7] Gao, H., Zhang, L., Chen, Z., Xing, Y., and Li, S., Beam hardening correction for middle-energy industrial computerized tomography, Nuclear Science, IEEE Transactions on 53(5), 27962807 (2006). [8] Shechter, G., Köhler, T., Altman, A., and Proksa, R., The frequency split method for helical cone-beam reconstruction, Medical Physics 31(8), 2230 2236 (2004). [9] Gao, H., Zhu, L., and Fahrig, R., Modulator design for x-ray scatter correction using primary modulation: Material selection, Medical Physics 37(8), 4029 4037 (2010). [10] Meyer, E., Raupach, R., Lell, M., Schmidt, B., and Kachelrieß, M., Frequency split metal artifact reduction (FSMAR) in computed tomography, Medical Physics 39(4), 1904 1916 (2012). [11] Yang, Q., Scherl, H., and Elter, M., Accelerated quantitative multi-material beam hardening correction(bhc) in cone-beam CT. European Congress of Radiology (ECR) (2012). DOI: 10.1594/ecr2012/C- 2161. [12] http://www.imp.uni-erlangen.de/phantoms/hip/hipphantom.html.