IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

Similar documents
Leuze electronic. Dimensioned drawing. Electrical connection. Accessories

Z-6910M Superb Bi-Optical In-Counter Scanner

X-Series System Manual Part 7: Interfaces and data communication

Fixed mount CCD bar code reader NFT Specification Ver. 1.0

Measurement range, typical

Assembly Instructions scancontrol 2700/2750 (500)

Operating Instructions SECUTEST SI /12.10

W&T Manual Interface modules W&T

Data Sheet. Code Reader BR 650 and CR 750 with remote sensor head. vision technology

WiFi to RS-232 adapter user manual

MicroHAWK ID-20 / ID-30 / ID-40

LVX Control Unit. Features:

MGate 5105-MB-EIP Quick Installation Guide

DATA TRANSMISSION PHOTOELECTRIC SENSORS. For contact-free, optical free-space data transmission.

FOR VISUAL CARD READER / WRITER. Installation Guide & Specifications

2D Image Handheld Scanner

Reference Guide METTLER TOLEDO WMH Weighing Platforms

Electrical connection

Manual Fiber Optic Interfaces

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

Dimensioned drawing. Measurement principle

TCNM-ACBB1 Installation Manual

Unique Micro Design First Choice of Professional Systems Intergrators. Model 361 Terminal Keyboard Wedge User Manual

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

DISCLAIMER. advanced PANMOBIL Systems GmbH & Co. KG. All rights reserved. International support contact:

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

Manual Industry Interfaces

MGate 5111 Quick Installation Guide

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

Quick Installation Guide

2D Image Hands-Free Scanner

HEC. General Operating, Maintenance and Installation Manual

UC-8410A Quick Installation Guide

MGate 5118 Quick Installation Guide

Product Specification. Shuttle XPC Accessory. COM / LPT / RJ11 port expansion for Shuttle XPC aio X50V4/V5/V6. Feature Highlight

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

FD-011WU. 2D Barcode Reader User Guide V1.6CC

Quick Start Guide. M2M Serial Modem NTC

NPort 6600 Series Quick Installation Guide

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

2DScan TM Barcode Scanner

MLD 500, MLD 300 Multiple Light Beam Safety Devices and transceiver with integrated muting

FP-1000PW. Thermal Printer User s Manual. Fujitsu Isotec Limited. KA02066-Y Standard Model Built-in Power Supply Model FP-1000

WiFi to RS-232 adapter user manual

AX3000 Platine Terminal Ethernet TCP/IP

User s Guide. Ethernet Module for Barcode Printer

Models: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL

Detection range, typical

RHODEUS PANEL I/O BOARD

Fieldbus Gateway Type ME43

Mounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth

Tel: Fax:

Installation and Operating Instructions. webremote

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Multi-Function Smart Indicator User Manual

IMAGE-BASED CODE READERS

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

RS-422 Code-Operated Switches

NEW! Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

General Operating, Maintenance and Installation Manual

Cable Pinouts. SRP I/O Module

AX3000 Platine Terminal Ethernet TCP/IP

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

MGate MB3170/MB3270 Quick Installation Guide

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

OFP401P0189. Color Sensor. Operating Instructions

NPort 6150/6250 Series Quick Installation Guide

The economical solution for continuous communication in automation

V2403 Quick Installation Guide

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

Manual Electronic Identification Systems BIS Processor BIS L-60_0 RS232 L-60_0-RS232_829572_0311_e.p65 Deutsch bitte wenden!

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

UPort 1200/1400/1600 Quick Installation Guide

Technical data. General specifications. Indicators/operating means

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

CCD-BARCODE SCANNER. Programming Manual. To program the device, scan the following codes: FIRST: start configuration %$ + / 0

NPort S8000 Series Quick Installation Guide

EasySYNC Ltd. USB to Serial Converters Manual

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

QUICK START GUIDE ODT-HH-MAH300 Handheld

WTS Intelligent Tactile Sensor Module. - User s Manual

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

MS5100. Eclipse Series. User s Guide

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Bar Code Scanner Specifications for XL200 Controllers

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Installation Manual. WKC Weigh Modules

EasySYNC Ltd. USB to Serial Converters Manual

MGate 4101-MB-PBS Series

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

Transcription:

IT 1910i Industrial 2D-code hand-held scanner EN 50123791 2013/06 We reserve the right to make technical changes TECHNICAL DESCRIPTION

2013 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Phone: +49 7021 573-0 Fax: +49 7021 573-199 http://www.leuze.com info@leuze.de

Contents 1 Scope of delivery... 5 1.1 IT 1910i xx... 5 2 Installation... 6 2.1 Connecting the hand-held scanner... 6 2.1.1 Switching off the PC... 6 2.1.2 Connecting the IT 1910i... 6 2.2 How do I scan codes?... 7 2.2.1 Testing the scanner... 7 3 Technical Data... 8 3.1 Pin assignments of the connection cable... 8 3.1.1 KB 232-1 IT 190x Part no. 50114517... 8 3.1.2 KB 232-1 IT 190x Part no. 50115105... 8 3.1.3 KB PS2-1 IT190x Part no. 50114519... 8 3.1.4 KB USB-1 IT 190x Part no. 50114521... 9 3.1.5 KB USB-2 IT 190x Part no. 50114523... 9 3.2 Reading fields... 9 4 Resetting the IT 1910i to factory settings... 10 5 Configuration... 11 5.1 IT 1910i to the serial PC interface... 12 5.1.1 With KB 232-1 IT190x Part no. 50114517... 12 5.1.2 With voltage supply via PIN 9... 12 5.1.3 With voltage supply via power supply unit... 13 5.1.4 Configuration for the Leuze standard protocol... 13 5.2 IT 1910i to MA 200i... 14 5.2.1 Commissioning... 14 5.3 IT 1910i to MA 21... 16 5.4 IT 1910i to PS2 interface... 17 5.5 IT 1910i to USB interface (keyboard emulation)... 18 5.6 IT 1910i to USB interface (COM port emulation)... 19 5.7 Activating the read process... 20 5.8 Configuration... 20 5.9 Troubleshooting... 21 6 Type overview... 22 7 Accessories/Spare parts... 23 Leuze electronic IT1910i 3

7.1 Connecting to Leuze multinet Plus... 24 7.2 Connection to various fieldbuses using MA 200i... 24 8 Service and support... 25 Leuze electronic IT1910i 4

1 Scope of delivery Scanner reading field Type designation Information about standards 1.1 IT 1910i xx 1. Hand-held scanner IT 1910i xx 2. Package insert An overview of the types can be found on page 22. For accessories, see page 23. Leuze electronic IT1910i 5

2 Installation 2.1 Connecting the hand-held scanner Cable latch The individual steps for installing the cable on the scanner are shown in the adjacent figure. 2.1.1 Switching off the PC NOTICE Make sure that the PC is switched off before connecting the scanner. 2.1.2 Connecting the IT 1910i 1. To secure the connection cable to the scanner, proceed as follows: Insert the RJ 41 connector into the socket on the bottom of the hand-held scanner, close the cord grip and secure it using the screw. 2. Connect the other end of the connection cable to the appropriate connection socket on the PC. 3. You may need a power supply unit for supplying voltage; alternatively, you can use a cable which supplies voltage from the computer system. Use the pin assignments (see page 8) to select the appropriate cable for your application. 4. Connect the power supply unit to the power socket (not necessary if voltage is supplied from the computer). 5. Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface and pulling the trigger. A red laser pattern as well as the red illumination should now be visible. Now scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the PC. Leuze electronic IT1910i 6

2.2 How do I scan codes? This section explains the best way to scan codes: The scanner must be held at a slight angle to the bar code. (Do not hold the scanner at a right angle to the bar code.) The red scanning pattern which serves as an alignment aid should be positioned at the center of the code. This ensures that the center point of the camera is aligned with the code. (The scanner will not be able to detect the label correctly if it is not fully captured by the camera.) The red scanning pattern is smaller when the scanner is held closer to the code. Small codes should be read at a smaller reading distance. With larger codes, the reading distance must be large enough so that the camera can capture the complete code. 2.2.1 Testing the scanner The adjacent bar code can be used for testing the scanner, the module size is 0.5 mm (20 mil) Code 39 bar code sample Leuze electronic IT1910i 7

3 Technical Data The technical data can be found in the data sheet for the IT 1910i. 3.1 Pin assignments of the connection cable 3.1.1 KB 232-1 IT 190x Part no. 50114517 Helix cable, maximum length 3 m. Signal level 0 and +5 volts TTL Pin assignments of the 9-pin D-sub socket (female) for cable CBL-020-300-C00 Pin number Signal Designation 1 nc Not used 2 TX Transmit data 3 RX Receiving line / Receive Data 4 nc Not used 5 GND Ground connection 6 DTR Data set ready (+5 volt connected to output) 7 CTS Clear to send 8 RTS Request to send 9 VCC IN 4.5 5.5 V DC (if no power supply unit is connected to the power supply unit connection) Pin at power supply unit connection Signal Designation Inside VCC IN 4.5-5.5 V DC Outside GND Ground connection For the suitable power supply unit for IT 190x (100-230 V/50 60 Hz), see chapter 7. 3.1.2 KB 232-1 IT 190x Part no. 50115105 As with part number 50114517, but True RS 232 variant available with -12 to +12 volt signal level. Cable designation: CBL-120-300-C00. 3.1.3 KB PS2-1 IT190x Part no. 50114519 Helix cable, maximum length 3 m. Pin assignments of the Mini DIN socket or connector for cable CBL-720-300-C00 Pin connector Pin socket Signal Designation 1 - PC Data PC data line 2 2 NC Not used 3 3 GND Ground connection 4 4 VCC IN 5 Volts DC 5 - PC Clock PC clock line 6 6 NC Not used - 1 KB data Keyboard data line - 2 KB clock Keyboard clock line Leuze electronic IT1910i 8

3.1.4 KB USB-1 IT 190x Part no. 50114521 Straight cable, maximum length 3 m. Pin assignments of USB type A connector for cable CBL-500-300-S00 USB type A connector Signal Designation 1 VCC IN 5 Volts DC 2 Data - Data line - 3 Data - Data line + 4 GND Ground connection 3.1.5 KB USB-2 IT 190x Part no. 50114523 Pin assignments of USB type A connector for cable CBL-500-500-C00: as with part no. 50114521, but helix cable, maximum length 5 m. 3.2 Reading fields IT 1910i ER-3 Code 39 UPC Code 39 PDF 417 Data Matrix QR Code 5 mil (0.127 mm) 6.7 mil (0.170 mm) 10 mil (0.254 mm) 13 mil (0.330 mm) 20 mil (0.508 mm) 20 mil (0.508 mm) Typ. reading distance 1) [mm] 1) Dependent on code module Leuze electronic IT1910i 9

4 Resetting the IT 1910i to factory settings To reset all parameters to factory settings, scan the bar code shown below. Attention! All settings are lost! Leuze electronic IT1910i 10

5 Configuration Usually, bar codes are used to configure the hand-held scanner. Select the desired bar code and scan it (see chapter 2.2). The configuration is then immediately accepted and executed. A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the VisualXpress PC program. You can download and install this program from our homepage at www.leuze.com. The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time. The standard applications are described and summarized below. Leuze electronic IT1910i 11

5.1 IT 1910i to the serial PC interface 5.1.1 With KB 232-1 IT190x Part no. 50114517 For pin assignments, see chapter 3.1.1. 5.1.2 With voltage supply via PIN 9 Please connect the IT 1910i acc. to the adjacent figure. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114517 KB 232-1 IT190x RS 232 transmission with 115200 baud, 8 data bits, 1 stop bit, no parity, no prefix and suffix. Leuze electronic IT1910i 12

5.1.3 With voltage supply via power supply unit Please connect the IT 1910i acc. to the figure below. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114517 KB 232-1 IT 190x 1x 50114525 Power supply unit RS 232 transmission with 115200 baud, 8 data bits, 1 stop bit, no parity, no prefix and suffix. 5.1.4 Configuration for the Leuze standard protocol Leuze standard protocol: RS 232 with 9600 baud, 8 data bits, 1 stop bit, no parity, prefix STX and suffix CR/LF Leuze standard protocol Leuze electronic IT1910i 13

5.2 IT 1910i to MA 200i RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, suffix CR/LF. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114517 KB 232-1 IT 190x 1x 50113397 KB JST-HS-300 1x 50112893 MA 204i Profibus gateway or 50112892 MA 208i Ethernet gateway or 50112891 MA 248i Profinet gateway 5.2.1 Commissioning Open the MA 200i Guide KB JST-HS-300 with the PG cable gland through the threaded hole and insert the 12-pin JST connector Connect the IT 1910i with the RS 232 cable Connect the cable to the 9-pin D-sub connector Set the address using the address switch Insert the field bus connection cable Apply the voltage supply. Leuze electronic IT1910i 14

IT1910i KB JST-HS-300 approx. 0.3 m 9-pol. D-sub 18 to 30 V DC Details on connecting the MA 200i can be found in "Technical description MA 200i". 5.2.1.1 Configuration Data transmission to MA 200i Leuze electronic IT1910i 15

5.3 IT 1910i to MA 21 RS 232 transmission with 9600 baud, 7 data bits, 1 stop bit, even parity, suffix CR/LF. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114517 KB 232-1 IT190x 1x 50035421 KB 021 Z 1x 50030481 MA 21 100 5.3.1.1 Pin assignments KB021 Z Core color Signal Terminal assignments MA 21 brown (RXD) 26 white (TXD) 27 blue (GND) 28 red (VCC) 30 black (GND) 31 bare (shield) (PE) 21 5.3.1.2 Configuration Connection to MA 21 with standard setting Leuze electronic IT1910i 16

5.4 IT 1910i to PS2 interface The operation of the IT 1910i in keyboard-wedge mode is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114519 KB PS2-1 IT190x Disconnect Please connect the IT 1910i acc. to the adjacent figures. To do this, proceed as follows: 1. Switch off the PC. 2. Unplug the keyboard. 3. Plug in the IT 1910i hand-held scanner between the keyboard and the PC. 4. Switch the PC back on. 5. Scan the code shown below. 5.4.1.1 Configuration PS2 keyboard emulation with CR LF Leuze electronic IT1910i 17

5.5 IT 1910i to USB interface (keyboard emulation) The operation of the IT 1910i in keyboard-wedge mode on a USB port is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114521 KB USB-1 IT190x or 50114523 KB USB-2 IT190x Please connect the IT 1910i acc. to the adjacent figure. To do this, proceed as follows: 1. Plug the IT 1910i hand-held scanner into a free USB port. 2. The scanner acknowledges this connection with an acoustic signal. 3. Scan the code shown below. 4. The standard keyboard driver is then installed. 5.5.1.1 Configuration USB keyboard emulation with CR LF Leuze electronic IT1910i 18

5.6 IT 1910i to USB interface (COM port emulation) The operation of the IT 1910i as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be downloaded from our homepage at www.leuze.com. Thus, the data can be processed further in programs which expect data via COM interfaces. Required parts: 1x 50122436 IT 1910i ER-3 1x 50114521 KB USB-1 IT190x or 50114523 KB USB-2 IT190x Please connect the IT 1910i acc. to the figures shown below. To do this, proceed as follows: 1. Install the USB serial driver for the 1910i. To do so, copy the driver from the CD-ROM or from our homepage to the PC. Unpack the file and start INSTALL.BAT. This requires administrator privileges on the PC! 2. Plug the IT 1910i hand-held scanner into a free USB port. 3. The scanner acknowledges this connection with an acoustic signal. 4. Scan the code shown below. 5. Open a terminal program or your program for the serial interface, select the new COM port, and make the following settings: baud rate 115200, 8 data bits, 1 stop bit and no parity. A CR is transmitted as suffix (or terminator). Leuze electronic IT1910i 19

5.6.1.1 Configuration COM port emulation on the next free COM address with 38400 baud, 8 data bits, 1 stop bit, no parity and a CR as suffix. 5.7 Activating the read process To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits. The activation command is: SYN T CR ASCII decimal values: 022; 084; 013 To cancel read readiness, send a deactivation. The deactivation command is: SYN U CR ASCII decimal values: 022; 085; 013 Following a successful read operation, the IT 1910i deactivates itself. The second option is to use the trigger button to establish read readiness. 5.8 Configuration Further details on configuration, such as parameters for code type release, number of digits, etc., can be found in the User's Guide IT 1910i/1911i. Leuze electronic IT1910i 20

5.9 Troubleshooting For problem detection and troubleshooting, examine your scanner as follows: 1. If the scanner is supplied with power via the connection cable, the scanner and PC must be connected to each other before the scanner is commissioned. The PC must supply the scanner with 5 V DC. Check the manual for your PC to ensure that the power supply is adequate for connecting your scanner. 2. Make certain that the connection cable is securely connected to the PC. You can find information on properly connecting the scanner in the manual for your PC. Support is also available from your technical staff. 3. If your system operates with an external voltage supply, make certain that the power supply unit is properly connected to the scanner. 4. Check that the connection cable is securely connected to the handle of the scanner. Remove the fastening clip and pull out the cable. Now guide the cable back in and make certain that it is properly seated in the bracket. 5. If, even after performing all of these measures, the scanner is not ready for operation, replace the power supply unit with a different recommended power supply unit which you are certain functions properly. 6. Make certain that your scanner's interface is compatible with the PC. Further information on this topic can be found in the manual for your PC. Also check whether the scanner has been configured for the desired application. This information is given in the User s Guide IT 1910i/1911i. 7. Check whether the bar code labels which you would like to scan are of suitable quality and that the used bar code type is recognized by your scanner. Damaged bar code labels (crinkled, torn or soiled) may be recognized poorly or not at all by the scanner. If you suspect that the problem lies with the quality of the label, check the read readiness with a label of relatively good quality. 8. If the problems are still not corrected, please contact the Leuze electronic hotline (see chapter 8). Leuze electronic IT1910i 21

6 Type overview IT series Part no. Designation Interface Figure Hand-held reader for bar codes and 2D-codes (extended range) 50122436 IT 1910i ER-3 PS2 / USB / TTL RS 232 All devices are supplied without cable. Cables must be ordered separately; see chapter "7 Accessories/Spare parts". Leuze electronic IT1910i 22

7 Accessories/Spare parts Accessories for IT series Part no. Designation Length, type P/N no. Figure 50114519 KB PS2-1 IT 190x PS2 cable for IT 190x 3 m spiral CBL-720-300-C00 50114521 KB USB-1 IT 190x USB cable for IT 190x 3 m straight CBL-500-300-S00 50114523 KB USB-2 IT 190x USB cable for IT 190x 5 m spiral CBL-500-500-C00 50114517 KB 232-1 IT 1910i RS 232 cable for IT 190x 3 m spiral CBL-020-300-C00 50115105 KB 232-2 IT 1910i RS 232 cable for IT 190x 3 m spiral CBL-120-300-C00 50114525 NT f. IT 190x+Base-EU Voltage supply for IT 190x (5 V DC), RS 232 cable and base station 1.8 m straight 46-00526 50120444 BT Wallholder HS65x8 wall mount; plastic 11-66553-06R 50107034 Rope for IT3800i/4800/6300 steel rope; plastic ToolBalE Leuze electronic IT1910i 23

7.1 Connecting to Leuze multinet Plus MA 21 100 Interface converter / multinet plus Part no. 50030481 KB 021 Z Connection cable MA xx to IT 1910i Part no. 50035421 7.2 Connection to various fieldbuses using MA 200i MA 204i Profibus gateway Part no. 50112893 or MA 208i Ethernet gateway Part no. 50112892 or MA 248i Profinet gateway Part no. 50112891 KB JST-HS-300 Connection cable MA xx to IT 1910i Part no. 50113397 Leuze electronic IT1910i 24

8 Service and support 24-hour on-call service at: +49 (0) 7021 573-0 Service hotline: +49 (0) 7021 573-123 Monday to Thursday 8.00 a.m. to 5.00 p.m. (UTC+1) Friday 8.00 a.m. to 4.00 p.m. (UTC+1) E-mail: service.identify@leuze.de Return address for repairs: Service center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Leuze electronic IT1910i 25