Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

Similar documents
Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

Features. LXI Compliant LAN. Power GEN V 0 65A 5200W GEN V 0 50A 5000W GEN V 0 34A 5100W GEN V 0 25A 5000W

Features. LXI Compliant LAN. Power W GEN V 0 55A 3300W GEN V 0 42A 3300W GEN V 0 33A 3300W GEN V 0 22A 3300W

Genesys TM. Programmable DC Power Supplies 10/15kW in 3U Built in RS-232 & RS-485 Interface Parallel Current Summing Optional Interfaces: Compliant

GEN W SERIES. LXI Compliant LAN. Laboratory Power Supplies: 750 ~ 1500W. Features. Programming Options: How to order:

Features. LXI Compliant LAN. Power GEN V 0 40A 2400W GEN V 0 30A 2400W GEN V 0 24A 2400W GEN V 0 16A 2400W

Programmable DC Power Supplies 750W/1500W in 1U Built in RS-232 & RS-485 Interface Advanced Parallel Operation Optional Interface:

Programmable Power Supply ( Supplies )

Improved. Specifications

Genesys TM. Programmable DC Power Supplies 750W in a 1U half-rack size

Series. Programmable DC Power Supplies 200W/400W/600W/800W in 2U Built-in USB, RS-232 & RS-485 Interface

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Series Programmable DC Power Supplies 1.7kW-5kW in 1U 0-600V / 0-500A 10kW in 2U / 15kW in 3U / A 1.5), USB, RS-232 & RS-485 Interfaces

NEW! ZERO-UP. Control Flexibility for Worldwide Applications 200W/400W/800W. Built-in RS232 & RS485 Interface with GPIB optional.

Series Watt DC Power Supplies

Control Flexibility for Worldwide Applications

Programmable Digital Controlled DC Power Supplies

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

Programmable DC Power Supplies XLN Series

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

CSPS-6K (Shelf Type) POWER you need POWER SHELF

Sorensen XEL & New XEL-P Series

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

How to Convert from a Sorensen DLM to an Agilent N5700

RMX-410x USER MANUAL RMX-4101 RMX-4102 RMX Rackmount Programmable DC Power Supplies 200W/400W/800W Built-in USB, RS-232, RS-485, LAN Interface

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

Output Voltage in Constant Voltage Mode. Model Number

A0750 AC-DC POWER MODULE

Output Voltage* (nom.)(adjustable)

RT4B-110V/12A RECTIFIER

CPCI - 6U - AC - 600W

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

T H U R L B Y T H A N D A R I N S T R U M E N T S

Uninterruptible Power Supplies

How to Convert from a Xantrex XFR to an Agilent N5700

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

(877) CPCI-6U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

RT4F-110V/25A RECTIFIER

Output Voltage* (nom.)(adjustable)

-AC Input- Voltage/Current...AC V, 47-63Hz, 5.5A Max, 1 Phase. Fusing...AC 6.3A, 250V internal line fuse provided, non-user serviceable. Power F

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

RT4F-48V/50A-WAC RECTIFIER

RT12-240V/2.4kW Rectifier Specification

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

LDD CW Laser Diode Drivers

An ISO 9001 Company. KLP POWER SUPPLY

Programmable DC Power Supplies 5kW in 2U Built in RS-232 & RS-485 Interface Advanced Parallel Operation Optional Interface: Compliant LAN IEEE488.

Programmable DC Power Supplies 3.3kW in 2U Built in RS-232 & RS-485 Interface Advanced Parallel Operation Optional Interface: Compliant LAN IEEE488.

Max Output Power Voltage. Convection Forced Convection Forced Nom Peak (2) Model Number (1)

User's Guide. Model W 3-in-1 Switching DC Power Supply

RT4F-120V/20A-WAC RECTIFIER

ORDERING INFORMATION SEE PAGE 6

TXP3500/4000 Series AC-DC Industrial PSU

RT7-48V/6kW Specification

Keysight Technologies How to Convert from a Sorensen DLM to a N5700. Application Note

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

LDY Series CW/QCW Laser Diode Drivers

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

OPERATOR S MANUAL HSF A, AM 600 WATTS POWER SUPPLY SINGLE OUTPUT POWER SUPPLIES SINGLE PHASE, POWER FACTOR CORRECTED UNIVERSAL AC INPUT

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

AIM & THURLBY THANDAR INSTRUMENTS

Safety Standards. Model Number:

99 Washington Street Melrose, MA Phone Toll Free Visit us at

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Laboratory Switch Mode Power Supply Series. Instruction Manual

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

PSU-HV Series Programmable Switching D.C. Power Supply

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number: Unit Weight:

Improved. Specifications

Universal Power Supplies

Load up on the NEW SERIES EL ELECTRONIC LOADS. from Kepco

Multi-Range Programmable DC Power Supplies 9115 Series

AP SERIES SYSTEMS POWER SUPPLIES. Autoranging power supplies for bench or systems use FEATURES

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

T H U R L B Y T H A N D A R I N S T R U M E N T S

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Manatronics 4kW Electronic Load

REGULATED DC POWER SUPPLIES.

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

TSX SERIES High power laboratory DC Power Supplies

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

CPCI - 6U - DC - 350W

SPECIFICATIONS. Input Output Approvals

MAJOR VA Power Inverter

DPS SERIES DC POWER SUPPLIES

Transcription:

Features Specifications: High Power Density 3.3KW in 2U 1 phase 240vac input 3 phase input 208VAC / 415VAC options Power Factor Correction Output voltage up to 600V, current up to 400A Built-in RS232 / RS-485 Interface Standard Last Setting Memory: Front Panel Lockout Advanced Parallel reports, with up to four units Reliable Encoders for Voltage & Current adjustment Optional Interfaces : Isolated Analog Programming & Monitoring IEEE Multi-Drop SCPI, USB interface Labview & LabWindows drivers Input Voltage ( 1 phase ) ( 3 phase ) No of Phases Input Frequency 230VAC ( 170 ~ 265 ) Code: 1P200 208VAC ( 170 ~ 265 ) Code: 3P208 415VAC ( 342 ~ 460 ) Code: 3P400 1phase or 3phase Wye or Delta, 4 wire with protective earth. 47 ~ 63Hz Input Current 1phase 230VAC models: 24A 3phase 208VAC models: 15A 3phase 415VAC models: 7.5A Efficiency Model dependent, typically 88% Power Factor 0.94 Leakage Current 3.5mA ( EN60950 ) Input Protection Phase Imbalance Parallel Operation Series Operation Operating Temp. Operating Humidity Line Fuse <5% on three phase input Up to four units may be connected in Master / Slave with Single Wire connection, refer to manual for further details. YES, with external diodes 0ºC to +50ºC at full load 20 ~ 80% RH Non-condensing Vibration & Shock MIL-810F method 514.5 Less than 20G, ½ sine, 11mSec. Altitude Operating: Up to 3000m Audible Noise ESD 65dBA at full load, measured 1m from front panel EN61000-4-2 Conducted Emission Radiated Emission Line Regulation Load Regulation Safety Cooling Input Connectors Output Connectors Overload Protection Foldback Protection Overvoltage Protection Over Temperature Protection Phase Loss Remote Analog Controls & Signals Digital Programming & Readback EN55011 Lev A EN55011 Lev A Model dependent refer to manual Model dependent refer to manual UL/CUL60960-1, EN60950-1, Units with IEMD or ISOL option are recognized up to 400V output, CE marked 208 & 400V models Fan driven, airflow front to rear, supplemental vents on side. Suitable for zero stacking top or bottom. Power Combicon PC 6 series with strain relief Up to & including 100V: Bus-bars 150-600V Phoenix clamp connector Constant Current with auto recovery Output shutdown, manual reset by front panel OUT button, response time <1sec Inverter shut-down, manual reset by ON/OFF recycle or by OUT button. OVP programming accuracy 5% full scale. If internal temperature exceeds safe levels. Latched in Safe Mode, Unlatched in Auto Mode. Phase loss protection Refer to manual Refer to manual Fast Transients Surge Immunity EN61000-4-4 EN61000-4-5 Dimensions 2U x 19in Rack mounting, slides or rear support required. 482 x 564 x 133mm ( without connectors ) Conducted Immunity EN61000-4-6 Weight 13kg Radiated Immunity EN61000-4-3 Manual & Full Application details available from our website of contact our office. REV 21-12-07

ModeI Output Power Model Output Power V A W V A W GEN8-400 0 8V 0 400A 3200W GEN10-330 0 10V 0 330A 3300W GEN15-220 0 15V 0 220A 3300W GEN20-165 0 20V 0 165A 3300W GEN30-110 0 30V 0 110A 3300W GEN10-15KW SERIES Laboratory GEN40-85 Power Supplies: 0 40V 10 ~ 15KW 0 85A 3300W GEN60-55 0 60V 0 55A 3300W GEN80-42 0 80V 0 42A 3300W GEB100-33 0 100V 0 33A 3300W GEN150-22 0 150V 0 22A 3300W GEN300-11 0 300V 0 11A 3300W GEN600-5.5 0 600V 0 5.5A 3300W Accessories: RS-232/RS-485 cable is used to connect the power supply to host PC Mode PC Connector Communication Cable Power Supply Connector RS-485 DB-9F Shield Ground L=2m RS-232 DB-9F Shield Ground L=2m RS-232 DB-25F Shield Ground L=2m P/N: GEN485-9 GEN232-9 GEN232-25 Input AC voltage Codes / Options 1phase 230VAC - 1P200 3phase 208VAC ) - 3P208 3phase 400VAC ) ( Australian Standard ) -3P400 Programming Codes / Options RS232 / RS-485 Interface built-in ( Standard ) GPIB ( Multi-Drop Master Interface ) IEEE Voltage Programming Isolated Analaog Interface IS510 Current Programming Isolated Analog Interface - IS420 Front Panel Controls Front Panel Display Remote Analog & Controls Vout voltage programming Iout voltage programming Vout resistor programming Iout resistor programming On/Off control (rear panel) Output current monitor Output voltage monitor Power supply OK signal CV/CC signal Enable/Disable Remote/Local selection Remote/Local signal Vout / Iout manual adjust by separate encoders, Fine and Coarse selectable. OVP/ UVL manual adjust by Voltage Adjust encoder, Front Panel Lock / Unlock Address selection by Voltage Adjust encoder. No of addresses:31 AC ON / OFF, Output ON */ OFF, Restart Modes ( Auto/Safe), Foldback Control (CV to CC), Go to Local RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch Baudrate selection by Current adjust encoder. Parallel Master Slave: Hx, where x = Slaves 0 up to four. Vout: 4 Digits, Accuracy: 0.5% +/- 1 Count Iout: 4 Digits, Accuracy: 0.5% +/- 1 Count Voltmeter is user selectable to read either local voltage (at power supply) or remote voltage (at the load). ADDR., OVP/UVL, V/A, FOLD, REM./LOCAL, OUT ON/OFF, LFP/UFP, CC/CV : GREEN LED ' s. ALRM (OVP,OTP,FOLD,AC FAIL): RED LED 0~1 00%, 0~5V or 0~1 0V, user selectable. Accuracy & Linearity +/-1% of Rated Vo. 0~1 00%, 0~5V or 0~1 0V, user selectable. Accuracy & Linearity +/-1% of Rated Io. 0~100%, 0~5/10kohm full scale, user selectable. Accuracy & Linearity +/-1% of Rated Vo. 0~100%, 0~5/10kohm full scale, user selectable. Accuracy & Linearity +/-1% of Rated Io. By Voltage: 0.6V = Disable, 2-1 5V = enable (default) or dry contact, user selectable logic 0~5V or 0~1 0V, accuracy:1 %, user selectable 0~5V or 0~1 0V, accuracy:1 %, user selectable Yes. TTL high-ok, 0V (500ohm impedance)-fail CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~04V):10mA Dry contact. Open: Off, Short: On. Max. voltage at Enable/Disable Contacts 6V Selects Remote or Local operation by Voltage: 0~0.6V/2~1 5V, <0.6V = Local 2-1 5V = Remote Signals operating mode in use.

Front Panel Description 1 4 6 2 3 5 8 7 1. ON/OFF Switch 2. Air Intake allows zero stacking for maximum system flexibility and power density. 3. Reliable encoder controls Output Voltage, Address, OVP and UVL settings. 4. Volt Display shows Output Voltage and directly displays OVP, UVL and Address settings. 5. Reliable encoder controls Output Current, sets baudrate and Advanced Parallel mode. 6. Current Display shows Output Current and displays Baud rate. Displays total current in Parallel Master/Slave Mode 7. Function/Status LEDs: Alarm Foldback Mode Fine Control Remote Mode 8. Pushbuttons allow flexible user configuration Coarse and Fine adjustment of Output Voltage/Current and Advanced Parallel Master or Slave Preview settings and set Voltage/Current with Output OFF, Front Panel Lock Parallel Master/Slave Set OVP and UVL Limits Set Current Foldback Protection Go to Local Mode and select Address and Baud rate Output ON/OFF and Auto-Re-Start/Safe-Start Mode Rear Panel Description Preview Settings Output On 9 6 7 8 1 2 3 4,5 1. Remote/Local Output Voltage Sense Connections. 2. DIP Switches select 0-5V or 0-10V Programming and other functions. 3. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor and other functions. 4. RS-485 OUT to other Genesys Power Supplies. 5. RS-232/RS-485 IN Remote Serial Programming. 6. Output Connections: Rugged busbars (shown) for up to 100V Output; wire clamp connector for Outputs >100V. 7. Exit air assures reliable operation when zero stacked. 8. Input: 208 & 400VAC Three Phase, 50/60 Hz AC Input Connector: PHOENIX CONTACT Power Combicon PC 6/... Series with strain relief. 9. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog Interface or LAN Interface.

Parallel operation - Master/Slave: Active current sharing allows up to four identical units to be connected in an auto-parallel configuration for four times the output power. In Advanced Parallel Master/Slave Mode, total current is programmed and reported by the Master, Up to four supplies act as one. Series operation Up to two units may be connected in series to increase the output voltage or to provide bipolar output. (Max 600V to Chassis Ground). Remote Programming via RS-232 & RS-485 Interface Standard Serial Interface allows daisy-chain control of up to 31 power supplies on the same communication bus with built-in RS-232 & RS-485 Interface. Programming Options (Factory installed) Digital Programming via IEEE Interface IEEE 488.2 SCPI Compliant Program Voltage Program Current Measure Voltage Measure Current Over Voltage setting and shutdown Current Foldback shutdown Error and Status Messages New! Multi-Drop Allows IEEE Master to control up to 31 slaves over RS-485 daisy-chain Only the Master needs be equipped with IEEE Interface P/N: IEEE Isolated Analog Programming Four Channels to Program and Monitor Voltage and Current. Isolation allows operation with floating references in harsh electrical environments. Choose between programming with Voltage or Current. Connection via removable terminal block: Phoenix MC1,5/8-ST-3.81. Voltage Programming, user-selectable 0-5V or 0-10V signal. P/N: IS510 Power supply Voltage and Current Programming Accuracy ±1% Power supply Voltage and Current Monitoring Accuracy ±1.5% Current Programming with 4-20mA signal. P/N: IS420 Power supply Voltage and Current Programming Accuracy ±1% Power supply Voltage and Current Monitoring Accuracy ±1.5% LAN Interface Compliant to Class C P/N: LAN Meets all LXI-C Requirements Address Viewable on Front Panel Fixed and Dynamic Addressing Compatible with most standard Networks VISA & SCPI Compatible LAN Fault Indicators Auto-detects LAN Cross-over Cable Fast Startup

Outline Drawing Genesys 3.3 kw/5 kw Units 3 Phase Input Connector 1. Bus bars for 8 V to 100 V models (shown) Wire clamp connector for 150 V to 600 V models 2. Plug connectors included with the power supply 3. Chassis slides mounting holes #10-32 marked A GENERAL DEVICES P/N: C-300-S-116 or equivalent