DKC. VARIZON Displacement unit with adjustable spread pattern

Similar documents
DRI. VARIZON Displacement unit with adjustable spread pattern

IBISTM. Duct diffuser with discs for supply air

IBIS. Duct diffuser with discs for supply air QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS

VIREO Ceiling with ALX

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

Floormaster DVQA, quarter-cylindrical terminals

SIRI. Measurement and control damper QUICK FACTS

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

Ceiling diffusers - visible

Adjustable swirl diffuser PDZA TECHNICAL DATA

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

Ventilation grille. Dimensions

NORDgrille Internal grilles

Circular and semi-circular displacement outlet Q-Z...

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA

Rectangular straight silencer

Square swirl diffuser PZK(A,B), PWK(A,B)

ROL and ROL-S. climecon.fi

BAR GRILLE TYPE: A-600

Grille. Min. - max. dimensions

S u p p l y a i r h o o d J S I

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern.

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments.

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP

NORDsilencers Ventilation system silencers

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper

LOOK hidden linear diffusers

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

Filter Fan Unit LIGHT

Multitronic. Technical data

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

U V-Tu r b o h o o d s

Limanda. Technical data

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

DESIGNED FOR THE FUTURE A NEW CONCEPT IN HATCH VENTILATION SYSTEMS

CEILING SWIRL DIFFUSER MLD

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Variable Flow Rate Control Unit

5. Office furniture. 5. Office furniture. Laboratory furniture. Flexible and customised

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks

Limanda. Technical data

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Technical Information DAMPA TILES Decorative Marine Ceiling System

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

LDK Slot Diffusers. Description. Throw directions. 2

Linear Luminaire with LED Series 6012/5

FMC cartridge filter. Compact cartridge filter for solving dust problems within a wide range of industries

HOMESCREEN DELUXE Fixed frame projection screen for wall installations

CONTROLLING ROOFTOP UNIT (RTU) NOISE

Product Library and ISO 16757

ergonomics design flexibility

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle

HOMESCREEN DELUXE Fixed frame projection screen for wall installations

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

Linear Luminaire with LED Series 6412/5

SYSTEM WORLD PRODUCT INFO

Single action door patch fittings

one sleek, beautifully finished unit, water bearing flat front plate,

EcoTec SP tables and base cabinets

kyalfa V- VDD/VDD6 General Contents

Reliability and extended operation

OPERATION AND MAINTENANCE INSTRUCTIONS FOR THE SILVER C RX/PX/CX/SD

Flow Finder MK2 Powered Flow Hood

Hudevad Plan XV. technical datasheet

Control components for VAV terminal units

IRIS Damper Application Guide

Elabo TaMo. Mobile carrier system for industrial use

Operation Manual. rev Charge then remove battery when stored for more than 1 week. Flow Finder MK2. Powered Flow Hood

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

LCP Hybrid Efficient performance with heat pipe technology

Product Guide. Server Safes & Cabinets Modular Caging Security Walling Modular Enclosures

Vertiv Knürr MIR2 One system with Infinite Possibilities

Digital electropneumatic positioner

Product Brochure Edition 1. t: f: e: doncastercables.com

11. Wall and Floor Mounted Clips

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

DL2. Data sheet LINAK.COM/DESKLINE

Fixed Blade External Louvre

RUSIC 24. LPS Central supply system for emergency luminaires 24 V for separate fire areas

InBin-P Pressure switches from 5 Pa Pa

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

TRADUR. Supporting elements. Balance. Supporting elements

Knürr Synergy The New Product Family For Uniform Equipment In Your Control Room. Knürr Technical Furniture

Digital electropneumatic Positioner SideControl

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

Lindab Revit plugin for DIMsilencer and LindQST

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT

Free Standing DeltaV Double Door Cabinet

LPS Central supply system for emergency luminaires 24 V for separate fire areas

The ABC of the BCA 2010 Bradford solutions to Section J.

Laboratory Exhaust Systems

INSIDE. 25I60I80. Flexible and functional screen system with a contemporary design. Freiräume für Leistung.

Transcription:

VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of room which require large airflows Simple installation Cleanable Air volume measuring point Available in alternative colours Included in the MagiCAD and CadVent databases Quick guide A I R F L O W - S O U N D L E V E L l/s Size 2 db(a) db(a) 3 db(a) 00 900 (60) 00 (7) (00) 6 (80) 130 (00) 1600 () 800 00 (0) 220 (170) 2600 (00) Sound level is valid at m² equivalent sound absorption area at distance of 2 m from terminal. Values in parenthis is valid at m² equivalent sound absorption area. All values is valid without distrurbance on straight duct section. 1

Technical description Design The is a complete, rectangular displacement unit with rounded corners. It is designed to stand on the fl oor. The body consists of top and bottom plates and an air distribution plate equipped with a number of adjustable defl ectors. The top plate has a circular inlet muff. The diffusion plate has an access hatch for access to the duct system. The perforated front plate is fi xed to the unit with concealed screws, behind the removable aluminium side strips. The measuring point is placed on top of the unit. Materials and surface treatment The displacement unit is manufactured in galvanized sheet steel and aluminium profi les. It is coated with our pure white standard paint, RAL 90. The unit is also available in other standard colours: Dusty grey 7037, white aluminium RAL 9006, jet black RAL 900, grey aluminium RAL 9007 and signal white RAL 9003 (NCS 000). Customisation In addition to the standard sizes, these displacement units are available in special dimensions, with reinforced front plate etc. Please contact your nearest sales representative for further information. Accessories Plinth: T 2 - for the aesthetic concealment of the space between the feet of the unit. Planning It is possible to modify the affected area by adjusting the discs behind the front plate. This does not affect the air fl ow, pressure drop or sound level. This fl exibility simplifi es any future changes in the furnishing of the room etc. The displacement unit can be placed in the middle of a room, next to a pillar or near a wall. If placed next to a wall, the three-way spread pattern should be selected. N.B. The sound level in the engineering diagrams is valid at m 2 equivalent sound absorption area. This fact makes it important to check the air velocities in the connecting ducts to the terminals. Extra consideration has to be taken on how the ducts can be connected to the terminals. See Figure 3. Figure 1. Installation. Commissioning. Installation The terminal is placed on the fl oor and if necessary can be fi xed to the wall using angle brackets. See Figure 1. Commissioning The measuring point is placed on the top of the displacement unit. The k-factor of the unit is stated in the product label. The k-factor can also be found at www.swegon.com in the relevant k-factor guide. It is recommended that a measurement unit and commissioning damper is used to regulate the air fl ow. It should be placed at least 3 - duct diameters from the inlet of the unit. See Figure 1. Maintenance The displacement unit can be cleaned when necessary using luke warm water with added detergent. The duct system is accessed by removing the preforated front plate and the access hatch. See Figure 2. 2 We reserve the right to alter specifi cations. Figure 2.Maintenance. 070 www.swegon.com

Sizing Sound level db(a) applies to rooms of m 2 equivalent absorption area, which gives 16 db room attenuation, and measured 2 m from the displacement unit and with at a straight section without disturbance on straight duct section. Recommended maximum under temperature 6 K. To calculate the width of the spread pattern, air velocities in the zone of occupation or sound levels in rooms with other dimensions, please refer to our calculation programme ProAir web, which is available for download at www.swegon.com. Sound data - Sound power level L w (db) ( m 2 Sabine) Table K OK Size Mid-frequency (octave band) Hz 63 12 20 00 00 00 00 8000 00 18 17 16 1 1-8 -12 6 18 21 18 1 6-1 -1-18 800 18 21 18 1 6-1 -1-18 Tol. ± 2 2 2 2 2 2 2 2 Sound attenuation DL (db) ( m 2 Sabine) Table DL Size Mid-frequency (octave band) Hz 63 12 20 00 00 00 00 8000 00 9 3 1 1 1 1 1 6 7 3 2 1 1 1 0 0 800 6 2 1 1 1 0 0 0 Tol. ± 2 2 2 2 2 2 2 2 Table duct connections Duct connections v m/s A B C D - m/s + 2 + 6 + 3 + 3 6-8 m/s + + + 6 + 6 Effects on sound levels (db) for different duct connections and different air velocities in straight duct section. Figure 3. E.g. of how different duct connections affects the sound level of the terminal. We reserve the right to alter specifications. 070 www.swegon.com 3

Engineering graphs - Air flow - Pressure drop - Sound level - Affected area The graph shows data for sound levels in a room with an equivalent absorption area of m 2 and measured 2 m from the displacement unit and with at a straight section without distrurbance on straight duct section. See Figure 3 for how different duct connetions will affect the sound level. At the equivalent room absorption area of m 2 and 2 m from the disc the noise level increases by approx. db(a). The affected area refers to a displacement unit installed next to a wall, 0 mm on the floor. The affected area distance is related to the isovel limit of 0.2 m/s at Dt 3 K. The graphs are not to be used for commissioning. = min. air flow to obtain sufficient commissioning pressure. The db(c) value is normally 6-9 db higher than the db(a) value. For Dt = 6 K the measurements a 0, and b 0, are increased by approx. %. D 00, 3-way ( m 2 Sabine) 00, -way ( m 2 Sabine) 0 0 0 0 2 db(a) 3 0 0 2 db(a) 3 0 0 00 00 00 l/s 00 00 00 00 000 m 3 /h 0 0 00 00 00 l/s 00 00 00 00 000 m 3 /h b 0,2 m 2 3 2 3 2 3 We reserve the right to alter specifications. 070 www.swegon.com

6, 3-way ( m 2 Sabine) 6, -way ( m 2 Sabine) 0 0 2 db(a) 3 0 0 2 db(a) 3 3 00 00 00 00 00l/s000 00 00 00 000 000 m 3 /h 3 00 00 00 00 00l/s000 00 00 00 000 000 m 3 /h b 0,2 m 3 3 2 3 800, 3-way ( m 2 Sabine) 0 800, -way ( m 2 Sabine) 0 0 0 2 db(a) 3 0 0 2 db(a) 3 0,2 0,2 00 00 00 00 000 l/s 00 00 000 000 000 m 3 /h m m 00 00 00 00 000 l/s 00 00 000 000 000 m 3 /h We reserve the right to alter specifications. 070 www.swegon.com

Order key Dimensions and weights Product Size A ØD Weight,kg 00 700 99 6 Version 6 800 629 87 Size: 00, 6, 800 800 00 799 1 Spread pattern: 3-way = 3 -way = Square displacement unit e -aaa -b a -aaa Accessories Plinth plate T 2 Version Size: 00, 6, 800 Specification example SD XX Swegon's VARIZON square-section displacement unit of type, with the following functions: Figure.. Adjustable spread pattern and affected area Exchangeable front sections Non-fouling Air volume measuring point Cleanable Powder painted in white, RAL 90 Accessories: 6 We reserve the right to alter specifications. Plinth plate: T 2 aaa xx items Size: e aaa - b xx items 070 www.swegon.com