ELECTRICIANS REGULATIONS EXAMINATION 21 November 2015 QUESTION AND ANSWER BOOKLET

Similar documents
Electrician. Skilled Migration Assessment Services / Trades Recognition Services

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

National Certificate in Electrical Engineering (Electrician for Registration) (Level 4)

UNDERGROUND CONSTRUCTION MANUAL SERVICES

C&G 2391 ELECTRICAL INSPECTION AND TESTING

Weathersafe Vision. Installation & Operating Instructions

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Best Prac ce Guide 8 (Issue 2) Selection and use of plug-in socket-outlet test devices

Protection against electric shock

Meter Enclosure and Equipment Standards

Electrical industry update. Electrical inspectors get a makeover. Unmetered supply update. In this issue

FAQ about Drives Technology

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Zener Barriers Bulletin 937Z

Copyright 2015 Integrated Environmental Solutions Limited. All rights reserved.

Please use the Q & A utility to ask us any questions concerning the material being presented.

Extension module for lighting control

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

6219 Entry Level and Level 1 Awards, Certificates and Diplomas in Construction Skills Candidate task manual Plastering, Plumbing and Electrical

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Electrical Demand Specification (Reference SOP: )

Hippo Range Isolators - Page 1 of 2

Pro Logger II. Designed and manufactured in Australia.

Model 7705 Control Module

Model 2657A-LIM-3 LO Interconnect Module

TPE, TPED Series 2000

I/O module (Expansion module)

Course outline: 221 Cabling G106A UEENEEG106A - Terminate cables, cords and accessories for low voltage circuits

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

SURGE SUPPRESSOR INSTALLATION INSTRUCTIONS. Includes TDS-AR Alarm Relay and TDS-SC Surge Counter. ISSUE: 3 April

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

MEM31215 Certificate III in Engineering - Industrial Electrician

NZQA unit standard version 2 Page 1 of 5

SAMPLE HEAT PUMP WIRING DIAGRAMS

Sigma XT Ancillary Board (K588)

Questions/queries: Feedback and suggestions welcomed: (+61)

TG basic 1. Appliance tester for testing protective measures in accordance with DIN VDE (DIN EN 62638)

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

Commissioning Electrical Installations in Building Services Engineering

Portable Appliance Tester KT75 OPERATORS MANUAL

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

PanelView Plus/VersaView CE Terminals and Display Modules

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

This qualification has been revised. The last date to meet the requirements is 31 December 2021.

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Philips Lighting Laboratory, Philips Electronics India Ltd., C-47, Sector-57, Noida, Uttar Pradesh

DTC P0AA6 - High Voltage Isolation Fault

SWA Cable BS5467 Steel Wire Armoured PVC

Residential/Commercial/Industrial

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

User's Guide. Extech AM A AC Analog Clamp Meter

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

ST: TP14D/2 TEST SHEET COMBINED LV CT & METER CABINET INSTALLATIONS OFF-LOAD TESTING

DM3058/DM3058E Digital Multimeter

Fall Test 21 due 12/11/2012

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

CONTROL PANEL WIRING SPECIFICATIONS

BA505C 2-wire 4/20mA manual setpoint station Issue 6

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Installation Instructions

SECTION ELECTRIC METERING

Input Frequency: 650 range 50/60Hz 675 range Hz Input Ranges in Amps: Measurement Maximum Inrush

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

SoundwebTM. Installation Guide

Mini Digital Multimeter

GROUND FAULT CIRCUIT INTERUPTERS

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

MEMORANDUM SUBJECT: APPROVED POWER STRIPS AND SURGE PROTECTORS

User Guide True RMS Multimeter Extech EX205T

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

POCKET MULTIMETER Model No: MM18

Point-of-Use Surge Protection

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Product and functional description

LC2300 Level Controller Installation and Maintenance Instructions

Simple Logger II Series

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual

CR6S Stereo Micro Crush

Page 1. Universal controller for solar energy systems with one collector array and one storage reservoir COMMISSIONING MANUAL

LED MODULES FOR MAINS VOLTAGE

Specifications Sonia W Product Specifications LED Flood Lighting Sonia W

ECM-1220 User s Manual

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

OW MULTIVOLT 351/451/551

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

PCT2000. User Manual. Precision current transducer 2000 A

Installation instructions Inclination sensor EC2019 EC / / 2013

Transcription:

ER70 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 21 November 2015 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three hours You have 10 minutes to read this paper but do not start writing until you are told to do so by the supervisor. Write your Candidate Code Number in the box provided above. Your name must NOT appear anywhere in this paper. Answer all questions. The pass mark for this examination is 60 marks. Use a pen for written answers. Do not use pencils or red pens. Drawing instruments and pencils may be used when diagrams are required. Marks are allocated on the basis of correctness. Do not use correcting fluid or correcting tape. It is recommended that the reference source for your answers be included in the space provided if a question can be answered from the Act, Regulations, Standard or Code of Practice. However, just stating a reference only will earn no marks. For calculation questions all workings, including formulae, must be shown to gain full marks. You will need to use the following documents in this examination: Electricity (Safety) Regulations 2010 reprint dated 1 February 2014 or the reprint dated 1 August 2014 AS/NZS 3000:2007 (incorporating amendments 1 and 2) NZECP 34 PLEASE HAND THIS PAPER TO THE SUPERVISOR BEFORE LEAVING THE ROOM

Question 1 (a) Fittings are installed in an electrical installation. Refer to the Electricity (Safety) Regulations 2010 and state TWO situations where fittings that are installed in an installation are specifically deemed to be electrically unsafe. (1) (2) (b) Refer to the Electricity (Safety) Regulations 2010 and state the circumstance where an electrical appliance may cause injury to a person and is not electrically unsafe. 2

Question 1 continued (c) Refer to the Electricity (Safety) Regulations 2010 and state ONE situation where a fitting or electrical appliance is deemed to be electrically safe and it does not have a current tag issued in accordance with AS/NZS 3760. (d) Refer to the Electricity (Safety) Regulations 2010 and state TWO circumstances where a person cannot inspect prescribed electrical work. (1) (2) 3

Question 1 continued (e) A caravan that is to be hired or leased must comply with the requirements of the Electricity (Safety) Regulations 2010. (i) Refer to the Electricity (Safety) Regulations 2010 and state what document must exist before a person can hire out a caravan. (1 mark) (ii) Refer to the Electricity (Safety) Regulations 2010 and state ONE person who can issue the document stated in (a)(i). (1 mark) (f) Refer to AS/NZS 3000 and state TWO types of terminations permitted for tunnel-type terminals. (1) (2) 4

Question 1 continued (g) Refer to AS/NZS 3000 and state TWO methods of obtaining the value of the current in a final subcircuit either of which can be used to calculate the voltage drop in that circuit. (1) (2) (h) Refer to AS/NZS 3000 and state the reason why orange marker tape complying with AS/NZS 2648.1 is installed when underground cables are buried. 5

Question 1 continued (i) Refer to AS/NZS 3000 and answer the following: (i) A 230V, 2.5 mm 2 twin and earth TPS socket outlet final subcircuit has a combined phase and earth conductor resistance of 1.02Ω. Refer to AS/NZS 3000 and state the type and rating of a protective device for this final subcircuit. (1 mark) (ii) An earth fault loop impedance test gave a reading of 1.84 ohms. If the circuit is to be protected by a HRC fuse with a maximum operating time of 0.4s, what would be the maximum current rating of that fuse? (1 mark) (j) (i) Refer to NZECP 34 and state the minimum vertical distance from the ground of a 230V overhead insulated sub-main that crosses a footpath used only by pedestrians (1 mark) (ii) Refer to NZECP 34 and state the minimum vertical distance from the ground of a 230V overhead insulated sub-main that crosses a driveway. (1 mark) 6

Question 2 The measurement of the earth fault loop impedance of an electrical installation is one of the tests detailed in AS/NZS 3000. (a) (i) Refer to AS/NZS 3000 and define the term earth fault-loop impedance. (1 mark) (ii) Refer to AS/NZS 3000 and state ONE reason why the impedance of the earth fault-loop must be low. 7

Question 2 continued (b) Refer to AS/NZS 3000 and describe the earth fault loop. (4 marks) 8

Question 2 continued (c) Refer to AS/NZS 3000 and state TWO conditions for using aluminium conductors as earthing conductors. (1) (2) (d) Refer to AS/NZS 3000 and state the type and conductor material that must be used for copper earthing conductors. (1 mark) 9

Question 3 An electrical installation switchboard generally incorporates protective devices for the protection of circuits originating at the switchboard and switching devices for the control of parts of the installation. (a) Isolators may be incorporated on a switchboard. Refer to the AS/NZS 3000 and state FOUR methods of achieving isolation. (1) (2) (3) (4) (b) Refer to AS/NZS 3000 and state ONE isolation switch requirement for an electrical installation with more than one occupier. 10

Question 3 continued (c) (i) Refer to AS/NZS 3000 and state what protection by means of automatic disconnection of supply is intended to limit. (ii) AS/NZS 3000 details the types of devices that can be used for protection by automatic disconnection of supply. Refer to AS/NZS 3000 and state the restriction that applies to a device used for protection by automatic disconnection of the supply. (1 mark) (iii) Refer to AS/NZS 3000 and state TWO types of devices that can be used to provide automatic disconnection of supply. (1) (2) 11

Question 3 continued (d) Refer to AS/NZS 3000 and state ONE requirement regarding the size of the MEN link or connection in the first MEN switchboard in an electrical installation. (1 mark) 12

Question 4 Refer to AS/NZS 3000 and calculate the maximum demand in amps of a single 230V domestic installation with the following loads: Number Rating Equipment 30 50W Recessed luminaires 25 8W LED Lights 4 75W Fluorescent lights 10 150W Outdoor flood lighting 16 10A Double socket outlets 10 10A Single socket outlets 1 4kW Gas/electric range 1 3KW Water storage heater 1 6kW Sauna Where applicable, lights are to be calculated on a points basis. Use the table on the following page to perform the calculations. (10 marks) 13

Question 4 Equipment Load Group Calculation Load (A) 30, 50W recessed luminaires 25, 8W LED lights 4, 75W fluorescent lights 10, 150W outdoor light lamps 16, 10A double socket outlets 10, 10A single socket outlets 4kW range electric 3KW heater water 6kW sauna Maximum demand 14

Question 5 (a) Refer to AS/NZS 3000 and state FOUR types of wiring enclosures permitted for insulated unsheathed cables. (1) (2) (3) (4) (b) Refer to AS/NZS 3000 and state the requirement for the change of wiring enclosures in situations other than at a switchboard. 15

Question 5 continued (c) Refer to AS/NZS 3000 and state ONE requirement for the installation of conductors of different electrical installations. (d) Refer to AS/NZS 3000 and state the THREE requirements for the support of a low voltage track system. (1) (2) (3) 16

Question 5 continued (e) Refer to AS/NZS 3000 and state FOUR situations where wiring systems are likely to be disturbed. (1) (2) (3) (4) 17

Question 6 (a) A certificate of compliance is issued for the installation of conductors and fittings in an electrical installation. (i) Refer to the Electricity (Safety) Regulations 2010 and state ONE type of prescribed electrical work for which a certificate of compliance may be issued. (½ mark) (ii) Refer to the Electricity (Safety) Regulations 2010 and state TWO types of prescribed electrical work for which a certificate of compliance must be issued. (1 mark) (1) (2) (b) Refer to the Electricity (Safety) Regulations 2010 and state the TWO items that form the content of certificates of compliance. (4 marks) (1) (2) 18

Question 6 continued (c) (i) Refer to the Electricity (Safety) Regulations 2010 and state the THREE types of prescribed electrical work for which a electrical safety certificate must be issued (1½ marks) (1) (2) (3) (ii) The Electricity (Safety) Regulations requires that a person who issues an electrical safety certificate must be satisfied that TWO conditions exist. Refer to the Electricity (Safety) Regulations 2010 and state ONE of those conditions. (iii) Refer to the Electricity (Safety) Regulations 2010 and state when prescribed electrical work is considered to be complete on an electrical installation for which an electrical safety certificate will be issued. (1 mark) 19

Question 7 Introduction Testing is being carried out to establish whether or not a phase/neutral transposition has occurred on the consumers mains of a live single-phase low voltage electrical installation Use the information in the introduction to this question to answer parts 7(a), 7(b) and 7(c). (a) Refer to AS/NZS 3000 and state ONE situation that testing for polarity is intended to prevent in a single-phase low voltage electrical installation. (1 mark) (1) (2) (b) List the equipment and test instrument used to test the polarity of the consumers mains in a live single-phase low voltage electrical installation. (3 marks) 20

Question 7 continued (c) There are TWO points in the electrical installation where testing is carried out to find out whether or not a phase/neutral transposition has taken place on the consumers mains. (i) State where the first point of testing is and: Describe how the testing is carried out using the equipment stated in (b). State the expected instrument reading if a transposition has taken place. State the expected instrument reading if no transposition has taken place. (3 marks) 21

Question 7 continued (ii) State where the second point of testing is and: Describe how the testing is carried out using the equipment stated in (b). State the expected instrument reading if a transposition has taken place. State the expected instrument reading if no transposition has taken place. (3 marks) 22

Question 8 Introduction A 3 metre wide and 6 metre long in-ground swimming pool is being constructed. Various items of electrical cables and equipment need to be installed. Use the information in the introduction to this question to answer parts 8(a), 8(b), 8(c) and 8(d). (a) Refer to AS/NZS 3000 and state the minimum degree of protection for electrical equipment installed in each Zone of a swimming pool. (3 marks) (b) Refer to AS/NZS 3000 and state the requirements for a wiring system for a swimming pool. 23

Question 8 continued (c) Several 230V socket outlets for general use are to be installed as close to the pool as possible. (i) Refer to AS/NZS 3000 and state the minimum distance from the pool the socket outlets can be installed. (1 mark) (ii) Refer to AS/NZS 3000 and state the TWO methods of electrical protection that can be used for these socket outlets. (1) (2) 24

Question 8 continued (d) A pump house with 230V electrical equipment for water filtering is to be installed in Zone 1 of the swimming pool. The electrical equipment is rated IPX5 Refer to AS/NZS 3000 and state the TWO types of electrical equipment that can be installed (1) (2) 25

Question 9 Introduction A 230V final subcircuit originating at a factory switchboard supplies one double socket outlet and one single socket outlet. First socket outlet (double) Route length of 15 metres from the switchboard 4mm 2 twin and earth TPS cable. 3 kw load. The mv/a.m for the 4mm 2 twin and earth TPS cable is 11.2151 Second socket outlet (single) Route length of 10 metres from the first socket outlet 2.5mm 2 twin and earth TPS cable 2 kw load. The mv/a.m for the 2.5mm 2 twin and earth TPS cable is 18.018 The TPS cable is clipped touching. The maximum voltage drop permitted is 2.5%. Use the information in the introduction to this question to answer parts 9(a) and 9(b). 26

Question 9 continued (a) (i) Calculate maximum current in the 2.5mm 2 twin and earth TPS cable section of the final subcircuit (ii) Calculate voltage drop in the 2.5mm 2 twin and earth TPS cable section of the final subcircuit (b) (i) Calculate maximum current in the 4mm 2 twin and earth TPS cable section of the final subcircuit (1½ marks) (ii) Calculate voltage drop in the 4mm 2 twin and earth TPS cable section of the final subcircuit (1½ marks) 27

Question 9 continued (c) Determine by calculation whether the maximum voltage drop of the entire final subcircuit meets the voltage drop requirements. (3 marks) 28

For Candidate s Use For Examiner s Use Only Questions Answered Marks 1 In the box, write the number of EXTRA sheets you have used. Write NIL if you have not used any 2 3 4 5 6 7 8 9 TOTAL 29