NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010
|
|
- Jocelin Simpson
- 6 years ago
- Views:
Transcription
1 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010 ( ) 4 March (X-Paper) 09:00 12:00 This question paper consists of 6 pages.
2 ( ) -2- NC710(E)(M4)V TIME: 3 HOURS MARKS: 100 INSTRUCTIONS AND INFORMATION Answer ALL the questions. Read ALL the questions carefully. Number the answers according to the numbering system used in this question paper. Write neatly and legibly.
3 ( ) -3- NC710(E)(M4)V QUESTION 1: BASIC ELECTRICAL CIRCUITS AND SYSTEMS 1.1 You are required to wire a domestic installation comprising of the following: x plug circuit 1x light circuit Draw a neatly labelled circuit diagram, to show the wiring of a distribution board for the above circuits indicating ALL necessary components and protective devices. Indicate the size of the circuit breakers and the size of the wires you are going to use for the circuits. (10) 1.2 Compare a geyser and stove sub- circuit. How do they differ with respect to: The size of the circuit breakers used The size of the conductors used Their application (2) (2) (2) 1.3 Explain how you would secure the following: Surface mounted PVC conduit Surface mounted twin flex cable (2) 1.4 Sketch the IEC symbols of the following components A double-wound transformer A coil A fuse A single-pole switch A two-way switch (5) 1.5 After the wiring of an installation is completed, certain tests have to be completed to ensure it corresponds with the requirements laid down by SANS A certificate of compliance will then be issued. List FIVE compliance test that are compulsory. (5) 1.6 What is the purpose of the thermostat as used in a geyser? (2) [30]
4 ( ) -4- NC710(E)(M4)V QUESTION 2: WIRE WAYS AND LOW VOLTAGE CABLES 2.1 The cable from the supplier's meter box must be connected to the distribution board in your home How would you secure the PVC wire armoured cable to the metal distribution board? What tools would you use to secure the cable to the distribution board? 2.2 A newly built house needs to be wired. What types of wire ways would you use to wire this house? (2) 2.3 Choose a statement from COLUMN B that matches a statement in COLUMN A. Write only the letter (A E) next to the question number ( ) in the ANSWER BOOK. COLUMN A COLUMN B Line taps Soldered joint Mechanical connector Scotch cast joint Wire way A B C D E joining kit for armoured and unarmoured cables flexible conduit join overhead lines Britannia joint ferrule (5 1) (5) 2.4 A three-core cord was fitted to a three-pin plug. It was done in the following way: the blue conductor was connected to the load/live pin; the brown conductor was connected to the neutral pin and the green and yellow conductor was connected to the earth pin. Was the three-core cord correctly connected to the three-pin plug? If not how would you change the wiring on the three-pin plug. 2.5 When a PVC conduit is used in wire ways, wires need to be pulled into the conduit What tool would you use to pull the wires into the conduit? Explain how you would use this tool to get the wires into the conduit. (1) [20]
5 ( ) -5- NC710(E)(M4)V QUESTION 3: ELECTRIC MACHINES 3.1 List THREE types of direct current machines in general use. 3.2 Compare the operation of a DC Motor with that of a DC Generator. (Focus should be on energy conversion.) (4) 3.3 What key information is found on the nameplate of a motor? List THREE points? 3.4 Indicate whether the following statements are TRUE or FALSE. Write only 'true' or 'false' next to the question number ( ) in the ANSWER BOOK. Checklist for mechanical inspection: Make sure all covers and guards are in place. Check the bearings for wear. Inspect the brushes regularly for wear. Check if all mounting brackets are secure. Check the nameplate to see if all given data is clearly legible. Check the stator frame and shields. Make sure that the brush holders are accurately set. (7 1) (7) 3.5 A DC motor fails to start. What checks will you perform to establish the fault? [20] QUESTION 4: FAULT-FINDING AND TESTING 4.1 List TWO testing instruments you would use to test or to do fault-finding on components. (2) 4.2 Compare the operation of a fuse and a circuit-breaker. (4) 4.3 A fuse needs to be tested to see whether it is functional or not, after it has been removed from the circuit What testing instrument can be used to perform this test? How is the test done? (1) [10]
6 ( ) -6- NC710(E)(M4)V QUESTION 5: PROTECTION AND MEASURING INSTRUMENTS List FIVE meters that require replacement on a regular basis. List THREE types of displays that are used in measuring instruments. Compare a pre-paid meter with a kilowatt-hour meter. A meter could be mounted in different ways. List THREE ways meters could be mounted on walls or panels. A faulty metering unit needs to be replaced. Explain how you would replace the metering unit. (5) (4) (6) [20] TOTAL: 100
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRONIC CONTROL AND DIGITAL ELECTRONICS NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRONIC CONTROL AND DIGITAL ELECTRONICS NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010 (12041022) 19 February (Y-Paper) 13:00 16:00 Calculators may be used. This question
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationLED Slimline PAR RGBW 7x8W
VIS0495.3 LED Slimline PAR RGBW 7x8W User Manual KEEP THIS MANUAL FOR FURTHER NEEDS Key Features: 7 x RGBW QUAD 8W LED IP65 Weatherproof Die-Cast Housing Slimline, Compact & Stylish Design 45 Beam Angle
More informationTreadmill Embedded Touch Screen Won t Power Up
Treadmill Embedded Touch Screen Won t Power Up E-TRe and E-TRxe This document contains the necessary information to troubleshoot a treadmill with an embedded touch screen that will not power up. Follow
More informationNATIONAL CERTIFICATE (VOCATIONAL) ELECTRONIC CONTROL AND DIGITAL ELECTRONICS NQF LEVEL 3 NOVEMBER 2010
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRONIC CONTROL AND DIGITAL ELECTRONICS NQF LEVEL 3 NOVEMBER 2010 (12041023) 22 October (Y-Paper) 13:00 16:00 This question paper consists of 6 pages. (12041023) -2-
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationPS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL
PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL Issue 2010 ASL Intercom BV DESIGNED AND MANUFACTURED BY: ASL INTERCOM B.V. ZONNEBAAN 42 3542 EG UTRECHT THE NETHERLANDS PHONE: +31 (0)30 2411901
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationMS-7000: SuperStar Reader
The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationBulletin Installation of solar photovoltaic systems Rules , , , , and
Bulletin 64-5-0 Installation of solar photovoltaic systems Rules 64-060, 64-200, 64-214, 84-020, 84-024 and 84-030 Scope (1) Introduction (2) Disconnecting means (a) Disconnecting means for solar photovoltaic
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationTopic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW
Topic: TB No.: 10041 Date: Aug/2017 Affected Machines: UC4/UC10 &45 variants Priority: Medium Created By: Gareth Fitzpatrick From Serial No.:
More informationHow-To #7: Assemble an H-bridge Circuit Board
How-To #7: Assemble an H-bridge Circuit Board Making a DC motor turn is relatively easy: simply connect the motor's terminals to a power supply. But what if the motor is to be controlled by an Arduino,
More informationPanduit Basic Rack PDU
Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any
More informationPS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL
PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31
More informationELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS
ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic
More informationOperating manual. Series 450. Compact thermometer. BA01235O/09/en/
Operating manual Series 450 Compact thermometer BA01235O/09/en/01.13 71220279 2 Table of contents 1 Safety instructions... 3 2 Installation... 4 3 Wiring overview... 7 4 Commissioning... 7 5 Operation...
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationRoom unit with PPS2 interface
1 626 Room unit with PPS2 interface for use with: controllers with a PPS2 interface QAA88.3 Room temperature measurement Key buttons for adjustment of the room temperature setpoint Key buttons for operating
More informationM E M O R A N D U M I.S.
Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M
More informationAvanti HP Series Centrifuges Preinstallation
J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two
More informationCONTROL PANEL WIRING SPECIFICATIONS
CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationVBAR 270. User Manual. Version 1.2
VBAR 270 User Manual Version 1.2 VBAR 270 User Manual Page 1of 19 Introduction Thank you for purchasing VBAR 270. VBAR 270 is a LED light fixture for professional use. Using the RGB color mixing technology
More informationSAVE THESE INSTRUCTIONS
OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationPanduit Basic Rack PDU with Local Meter
Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted
More informationOPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd
OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123 Product: High Voltage AC Test Set Type: P123 Bicotest High Voltage Products Ltd Hellesdon Park Road, Drayton High Road, Norwich NR6 5DR United Kingdom Phone
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationdynamic white par manual
dynamic white par manual V2.0 AUGUST 2017 table of CONTENTS Dimensions 1 Safety information 2 Fixture overview 4 Introduction 5 AC power 5 Power voltage 5 Power cables 6 Relaying power to other devices
More informationCMSA-100 Manual. Cinema Media Server Automation
CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationAPS4 Inductive Proximity Sensors
APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,
More informationINSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could
More informationBreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide
This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check
More informationBS 217 DUAL CHANNEL MASTER STATION USER MANUAL
BS 217 DUAL CHANNEL MASTER STATION USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationone cool inverter. GT Series Solar Inverter Quick Install Guide v1.4
one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 This quick installation guide must be used in conjunction with the Installation Manual. For installation support contact your local
More informationChore-Tronics IDM Board Instruction
Chore-Tronics IDM Board Instruction Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact
More informationMS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications
The MiniStar Reader The MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also be mounted directly
More informationElectrical Integration of PV Systems. Ridha Hamidi, Ph.D.
Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various
More informationThree Phase Residential Solution for Australia, System Design and Installation Guidelines
Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.
More informationOPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating
More informationVRp Three-Phase Precision AC Voltage Regulator
VRp-22500-0338 Three-Phase Precision AC Voltage Regulator INSTALLATION INSTRUCTIONS Inspection and Unpacking Please inspect the wooden crate for obvious shipping damage. Some crates contain up to six (6)
More informationNATIONAL CERTIFICATE (VOCATIONAL) ELECTRONIC CONTROL AND DIGITAL ELECTRONICS NQF LEVEL 2 NOVEMBER 2009
NATIONAL CERTIFICATE (VOCATIONAL) ELECTRONIC CONTROL AND DIGITAL ELECTRONICS NQF LEVEL 2 NOVEMBER 2009 (12041022) 30 October (Y-Paper) 13:00 16:00 Calculators may be used. This question paper consists
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationLift Truck Parts Professionals
SB Connector 50 Amp Series connectors Housing w/springs Anderson Brad Anderson & contacts Wire AWG Part # Harrison # Part # Original # Gray 50 amp #6 69 900 000 7-70-P 000 7-70 #0/# 69G 90 000 7-7-P 000
More informationUNDERGROUND CONSTRUCTION MANUAL SERVICES
UNDERGROUND CONSTRUCTION MANUAL ack to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DESCRIPTION DWG CONSTRUCTION DESCRIPTION DWG Construction code guide - Underground service from overhead system 53 SERVICE
More informationNational Certificate in Electrical Engineering (Electrician for Registration) (Level 4)
NZQF NQ Ref 1195 Version 3 Page 1 of 11 National Certificate in Electrical Engineering (Electrician for Registration) (Level 4) Level 4 Credits 249 This qualification has been revised. The last date to
More informationSKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB
SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured
More informationInstalling Cisco RP-Series PDUs
This chapter contains the following sections: Preparing to Install an RP-Series PDU, page 1 Installing a Zero-U PDU, page 1 Installing a 1RU or 2RU PDU, page 7 Preparing to Install an RP-Series PDU Before
More informationSignal Connections CHAPTER
2 CHAPTER 3 Signal Connections This chapter provides useful information on how to connect input and output signals to the USB-4704 via the I/O connectors. Sections include: Overview I/O Connectors Analog
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationINSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.
(INDIA) VT. LTD. 5. INCOMING SULY CONDUCTOR TERMINATIONS AND DEVICES FOR DISCONNECTING AND SWITCHING OFF 5.1 Incoming supply conductor terminations The electrical equipment of the machine shall have only
More informationCommon Departures Interconnecting Facilities Requirements
Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low
More informationArmorConnect Power and Control Media
Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationPage 1 of 5. Increased Safety, Encapsulation and Dust
IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx
More informationMS-3000 MicroStar Reader
MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.
More informationBlue Weapon Laser. User manual UK. Version 1.0
Blue Weapon Laser User manual 152.754UK Version 1.0 CAUTION 15. Disposal : Please disposal of the unserviceable device according to the current statutory requirements. Please read this manual fully before
More informationWeathersafe Vision. Installation & Operating Instructions
Weathersafe Vision Installation & Operating Instructions IP66 Products covered by these instructions 1 TGVL01 TGVL02 TGVL03 TGVL05 TGV101N TGV201N TGV104N Single Gang 2-Way Switch [SP] 10AX (Fluorescent
More informationBLUE 3 INSTALLATION GUIDE
BLUE 3 INSTALLATION GUIDE CATCH Power BLUE 3 Installation manual - Page 1 IMPORTANT This product must be installed by a licensed electrician. This product must be installed according to the AS3000 Australian
More informationJanuary Bob Wright. 1 P age Bob Wright
The upgrade is completed using the 401 control board and three Step1 driver boards supplied as a kit by Conqueror Design and Engineering Ltd. The kit includes all cable terminators for connections to the
More informationDMX Switch Pack. User Manual. EU version shown P/N
DMX Switch Pack User Manual EU version shown P/N 35000010 1998-1999 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without
More informationRCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions
RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationDELUXE STEREO AMPLIFIER KIT
ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS CREATE YOUR OWN SPEAKER DOCK WITH THIS DELUXE STEREO AMPLIFIER KIT Version 2.0 Build Instructions
More informationKTX REMOTE INSTALLATION INSTRUCTIONS
KTX REMOTE INSTALLATION INSTRUCTIONS SPECIAL NOTE BOONE CABLE WORKS & ELECTRONICS, INC. 1773-219TH LANE - P.O. BOX 369 READ THIS ENTIRE BOOKLET BOONE, IOWA 50036 USA BEFORE PROCEEDING WITH PHONE (515)
More informationLC SmartGlass SPD SmartGlass
LC SmartGlass SPD SmartGlass Electrical Installation Manual Ireland 21 Cookstown Industrial Estate, Tallaght, Dublin 24, Ireland. Tel: +353 (0)1 462 9945 or 9949 Fax: +353 (0)1 462 9951 United Kingdom
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationELECTRICIANS REGULATIONS EXAMINATION 21 November 2015 QUESTION AND ANSWER BOOKLET
ER70 Candidate Code No. For Board Use Only Result Date Int Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 21 November 2015 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three
More informationElectrical Components and Equipment for General Use Self Inspection Checklist
Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Electrical Components and Equipment for General Use Self Inspection Checklist Guidelines:
More informationAI-102. IR Illuminator. Installation Guide. Rev IP Surveillance
AI-102 IR Illuminator Installation Guide Rev. 1.1 IP Surveillance Revision History: Rev. 1.0: Initial release Rev. 1.1: Changed effective IR range and power consumption. AI-102 Tube Type Infrared Illuminator
More informationInstallation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2
Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3
More informationNational Certificate in Electrical Engineering (Electrical Appliance and Electronic Servicing) (Level 3)
NQF Ref 1265 Version 3 Page 1 of 8 National Certificate in Electrical Engineering (Electrical Appliance and Electronic Servicing) (Level 3) Level 3 Credits 80 This qualification has been reviewed. The
More informationDIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E
INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for
More informationAC Power Meter GPM-8212 USER MANUAL
AC Power Meter GPM-8212 GW INSTEK PART NO. 82PM-82120MB This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationHI-POT TESTER User Manual
HI-POT TESTER 7600 User Manual Contents 1. Safety...- 3-1.1 General...- 3 - AC Power Supply...- 4-1.2 Adjustment, Maintenance and Repair...- 5-1.3 Static Electricity...- 5-2. General:...- 6-2.1Packing
More informationEmery County Senior Center Green River 06/07
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationMS-4000: ShootingStar Reader
: ShootingStar Reader The ShootingStar Reader The ShootingStar Reader is intended for installation on a solid metal surface, in proximity applications where a vandal-proof reader is required. The reader
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationDRH Hardware Maintenance Guide
Issue 1.0 Date 2013-04-10 HUAWEI TECHNOLOGIES CO., LTD. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationControl. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)
Part B, Section 2 Model This section covers the following unit configurations. 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G) Manifold 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Temperature
More informationThis qualification has been revised. The last date to meet the requirements is 31 December 2021.
NQF Ref 0223 Version 6 Page 1 of 8 National Certificate in Electrical Engineering (Level 3) Level 3 Credits 149 This qualification has been revised. The last date to meet the requirements is 31 December
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationReplacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch
Manual Supplement 00809-0200-400, Rev AA July 2005 Rosemount 220 Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 220 Vibrating Fork Liquid Level Switch Refer to the Rosemount
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationRCC45 ➁ Overview / /
RCC45 ➁ Overview 010.2936 More future and modularity Integration of POF and power Guaranteed modularity Long-term investment protection Flexible cabling solution Fast and convenient installation 1 010.2721