WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Similar documents
WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

digiclip Data sheet DF31DP Special features B en

digiclip Data sheet DF31CAN Special features B en

FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet

C500 Series Data Sheet

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Presented By. NicolScales.com Contact Us

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Precise weighing fine batching accurate filling

STANDARD TERMINAL. Digital Indicators. Product Number 3020

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

Weighing Indicator. Features. Description. Applications

R310 & N310 R320 & N320 Digital Indicator

CX27C. Industrial Ethernet Gateway. Special features. Data sheet. Block diagram

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

N420 R420 R423. series

PUE 5 Indicator. Reliability in industrial conditions Complex support of weighing process. Functions. Features

CAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT

Extruder Controls ExtruVision S

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den.

Signum Complete Scale Advanced SIWABBP SIWADCP SIWAEDG

MX590B-R. Pressure amplifier. Special features. Data sheet. Block diagram

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EU Type Examination Certificate

EC Type-Approval Certificate

TECHNICAL DATA. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection.

INTECONT PLUS for Measuring Systems

DMT345 and DMT346 Dewpoint Transmitters

Weight controller Maxxis 5

MMT330 Series Moisture and Temperature Transmitters for Oil

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

Weighing Electronics SIWAREX - PLC-based weighing electronics

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

U10M. Data Sheet. Force transducers. Special features. Mounting dimensions of the connection variants in mm [inch] B en

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

EC Type Examination Certificate

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Signum Complete Scales Supreme Stainless Steel SIWSBBS and SIWSDCS

MIC-2 Multi-instrument DATA SHEET

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Characteristics and functioning

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

INTECONT Tersus Mass flow rate measurement

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

3000 SERIES LOW PROFILE FLOOR SCALE.

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

General information. Display. Supply voltage

POSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

MCX08M2 Programmable controller

JUMO mtron T Measuring, Control, and Automation System

General information. Display. Supply voltage

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

PTU300 Combined Pressure, Humidity and Temperature Transmitter

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

M260 Load Cell Amplifiers

PUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C/41H measuring indicator...

Product data sheet accessories control and regulation Accessories AIRWIN

MX1609TB. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

Digital weighing technology solutions

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

Note: the wiring of the dead-man buttons has been changed since October 2001.

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

Quick Start Guide. English. FS22 DI Industrial BraggMETER DI

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

PUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C41H measuring indicator...

Characteristics and functioning

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

MODEL 9250 Preliminary data sheet

Transmitter WST 3 From prog. name W001A100. Technical Manual

LC0 DVP

MIC-2 MKII, Multi-instrument DATA SHEET

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Defender Multifunctional Bench Scale for Standard Industrial Applications. Washdown Bench Scales. Standard Features:

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Peripheral modules for distributed automation Wrocław tel ul. Wyścigowa 38 fax w w w. a r a p n e u m a t i k.

THYRO-S THYRO-A THYRO-AX THYRO-PX

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

User Manual Gateway component for EtherNet/IP

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

Printview: End module for internal data bus extension - Item No.:

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

JUMO mtron T Measuring, Control, and Automation System

Digital electropneumatic positioner

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

High-powered control system for sophisticated processes

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

THE new i SERIES....beyond your expectations... * preciamolen.com

LVX Control Unit. Features:

Transcription:

WTX120 Legal-for-trade industrial weighing terminal Special features - Connection of up to 8 SG load cells (350 ohm) via plug terminals - Display resolution up to 30,000, legal for trade up to 10,000e - Industrial interfaces such as PROFINET, EtherNet/IP with integrated Ethernet switch, or Profibus DP - Ethernet TCP/IP, Modbus-TCP (standard) - USB 2.0 interface (standard) - Operator-friendly configuration on site - Easy-to-read plain text display with backlight - HBM PanelX software - Rugged DIN rail mounting - Optional indicator for control cabinet installation Data sheet Dimensions in mm (1 mm = 0.03937 inches) 92

Specifications - WTX120 Type WTX120 Industrial display resolution d 30,000 Accuracy class as per OIML R76 (Class III and IIII) d=e 10,000 Input sensitivity (legal for trade) μv/e 0.33 Measurement range mv/v ±3 Load cell connection (short-circuit proof) Six-wire and four-wire circuit Max. number of load cells (short-circuit proof) Ω 8 x 350 Excitation voltage of load cells (short-circuit proof) V DC 5 Internal sampling rate 1/sec. 50-800 Internal resolution Divisions 524,000 Non-linearity of measuring range % 0.018 Temperature coefficient of the zero signal per 10 K % 0.003 Temperature coefficient of sensitivity per 10 K % 0.006 Filter Adjustable digital filter (low-pass) Minimum transducer resistance Ω 43 Alibi memory Multi-range Multi-interval 120,000 memory locations Yes, adjustable up to 3 ranges Yes, adjustable up to 3 ranges Supply voltage V DC 12 30 (-15% +10%) protected against polarity reversal Current consumption A 1.3 0.4 Maximum power consumption (when 8 x 350 ohm load cells connected) W 14.5 Maximum power loss W 11 Minimum core cross-section for potential equalization mm 2 2.5 Maximum number of weighing terminals that can be 8 connected in parallel Display DOT matrix LCD display, with backlight, dot matrix realization, indication of weight, unit of weight, zero and moving cursor, error messages in plain text, English Character height of weight value mm 15 Keyboard Membrane keypad, 5 short-stroke keys with dual assignment for adjustment and service settings Standard device connections with plug-in screw terminals Other standard device connections Ethernet and fieldbus interfaces (depending on device version) Serial interfaces with plug in screw terminals (depending on device version) for connecting to PC, printer or remote indication 1 x power supply, 1 x load cell connection, 2 x digital outputs, Load carrying capacity of the outputs: up to max. 500mA at 12-24 VDC; current consumption of the inputs up to max. 7mA at 12-24 VDC 1 x Ethernet (RJ45) 1 x USB 2.0 1 x external indicator connection (RJ11) PROFINET IO (RT), Profibus DP, EtherNet/IP, Ethernet/TCP, Modbus/TCP (via standard Ethernet interface on the back side of the device) RS232, RS485 (4-wire, non-isolated) HBM 2

Type Analog output with plug-in screw terminals (depending on device version) Digital inputs and outputs with plug-in screw terminals (depending on device version) Mounting type ma V VDC WTX120 0-20 ma, 4-20 ma; 0-10 V, 2-10 V; for gross or net weight; 15 bit resolution 30,000 increments, with possibility of adjustment up to 4 digital inputs and outputs Load carrying capacity of the outputs: up to max. 500mA at 12-24 VDC; current consumption of the inputs up to max. 7mA at 12-24 VDC, short-circuit proof, optically isolated DIN rail mounting Degree of protection per EN 60529 (DIN rail mounting) Material Material IP20 Stainless steel Weight, approx. kg 0.9 Dimensions (WxHxD) With optional shield rail mm 86 x 120 x 106 86 x 199 x 106 Temperature ranges Storage 25 C to +70 C at 95% rel. humidity, non-condensing Operation 10 C to +50 C at 95% rel. humidity, non-condensing Operation when subject to weights and measures legislation Standards 10 C to +40 C at 95% rel. humidity, non-condensing Measurement accuracy EN45501, OIML R76-1, R61-1, R51-1 Immunity to interference EN 61326-1 Emission (EME) EN 61326-1, EN55011, Class A, Group 1 Battery Type CR2032 Accessories Description External indicator for panel mounting with backlight for using WTX120 black box version; 27 black box units can be connected (1 black box subject to weights and measures legislation); 15 mm weight indicator and status information, 1 to max. 3 operator guidance rows, 5 keys for zero adjustment, tare balance and control; includes connection cable; material: stainless steel; dimensions (WxHxD): 110 x 107 x 35 mm; degree of protection: IP69K; weight: approx. 0.3 kg, maximum length of connection cable 10 m (not included with delivery) Connection cable for external display 1-WTX120-D, 10 m Legal for trade set comprising shield rail and 2 connection clamps; can be screwed to underside of housing, for attaching the cable shields of max. 10 cables for applications subject to weights and measures legislation Ordering number 1-WTX120-D 1-KAB2133-10 1-WTX120-LFTSET 3 HBM

Dimensions of external indicator Dimensions with shield rail 92 HBM 4

Product numbers PROFINET 1-WTX120-PNY-NO-NA 1-WTX120-PNY-A/-NA 1-WTX120-PNY-/D-NA 1-WTX120-PNY-AD-NA Profibus DP 1-WTX120-PBY-NO-NA 1-WTX120-PBY-A/-NA 1-WTX120-PBY-AD-NA EtherNet/IP 1-WTX120-EIY-NO-NA 1-WTX120-EIY-A/-NA Modbus-TCP 1-WTX120-EPY-NO-NA PROFINET with integrated display and 2xDO PROFINET with integrated display and 2xDO, 2xDI and AO PROFINET with integrated display and 4xDO, 4xDI PROFINET with integrated display and 4xDO, 4xDI and AO Profibus DP with integrated display and 2xDO Profibus DP with integrated display and 2xDO, 2xDI and AO Profibus DP with integrated display and 4xDO, 4xDI and AO Ethernet/IP with integrated display and 2xDO Ethernet/IP with integrated display and 2xDO, 2xDI and AO Modbus-TCP with integrated display and 2xDO K-WTX120, optional versions Ordering number K WTX120 Code Option 1: Ethernet-based or fieldbus interfaces PRONE PROFINET PROBU Profibus DP ETHIP EtherNet/IP ETHM/ Modbus-TCP Code Option 2: Integrated Display Y Integrated display N Black Box no display (can be combined with external indicator 1-WTX120-D) Code Option 3: Analog output (ma, V) and/or digital input and output (VDC) NO 2 x Digital Out (DO; Standard) A/ 2 x Digital Out, 2 x Digital In, Analog Out /D 4 x Digital Out, 4 x Digital In AD 4 x Digital Out, 4 x Digital In, Analog Out Code Option 4: Serial interfaces NOT Without (standard) RS4 RS485 (4-wire) RS2 RS232 Code Option 5: Firmware A Standard K-WTX120 - P R O N E - N - N O - N O T - A 5 HBM

Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure HBM and predict with confidence 6 Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Germany Tel. +49 6151 803 0 Fax +49 6151 803 9100 E-mail: info@hbm.com www.hbm.com