Safety Temperature Limiter TT-STL 50

Similar documents
Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

PHOENIX CONTACT Features

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer

Safety controller unit B1 /

Universal counter UZ 9648 Counting - length measurement - metering - positioning

JUMO Quantum PID100/PID200/PID300

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

02/11/2015

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

JUMO itron 04/08/16/32 Compact microprocessor controllers

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

E-STOP relays, safety gate monitors

SSR - Supplies - Relays

E-STOP relays, safety gate monitors

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

Contact protection relay

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Standard Signal Meter S 1010

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 402EM-24V

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Bulletin 817 Thermistor Protection Relay

Setpoint adjuster SG 1010 Output standard signals 0/ ma or 0/ V DC

E-STOP relays, safety gate monitors

PSR UC/ESAM4/3X1/1X2/B

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

E-STOP relays, safety gate monitors

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

E-STOP relays, safety gate monitors

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

PSR DC/ESP4/2X1/1X2

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Zelio Control-modular measurement and control relays 1

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

E-STOP relay, safety gate monitor

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Alarm Unit DG 3200 Control And Monitor Standard Signals

E-STOP relays, safety gate monitors

RM35TF V AC

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

ISOMETER isoev425 with coupling device AGH420

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

TB 45 Temperature limiter / monitor

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features

PHOENIX CONTACT - 01/2007

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

E-STOP relay, safety gate monitor

MINI-PS AC/10-15DC/8

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

DINALOG A 144 x 36 A1400 Light-Strip Indicator

AS-Interface Safety at Work

E-STOP relays, safety gate monitors

J itron DR 100 Microprocessor Controller

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions. Standstill monitor A / / 2011

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

Datasheet SRB301ST 24V (V.2)

Process Indicator PA308

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

PI-EX-ME-2NAM/COC-24VDC

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

The Indicator with 3 Limit Contacts

Installation / Control Technique

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Operating instructions. Speed monitor D / / 2014

ETD-BL-1T-OFF-CC- 10S

MSR178DP. Description. Features. Specifications

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Transcription:

GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature Limiter TT-STL 50 Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection - temperature monitor M Certified according to EN 61508 SIL2 M Input Pt100, 3-wire circuit or double thermocouple J, K, N and S M Temperature limit value and switching hysteresis programmable M Basic accuracy < 0.5%, ±2 digits M Reaction time 0.5 sec M Alarm output 1 relay, SPDT M Memory function for error report M Operation-lock feature (password protection) M Case for switchboard installation General Data Sheet TT-STL50 Page 1/5 Certified to DIN EN 14597 (replaces DIN 3440) SIL2 The STL50 safety temperature limiter is used where ever thermal processes must be monitored and the system must be transferred into a safe operational state in case of fault. If the permissible temperature limit value is reached, or if a fault occurs within the permissible temperature range on the monitoring equipment (sensor open, sensor short-circuit, failure of a component part in the device, fault in the software, failure or inadmissible value of the Supply voltage etc.), the STL50 switches off without delay. The alarm contact is activated, the LED ALARM on the front panel and the back-lighting of the display light up, and the error cause is indicated as plain text on the display. In addition, there is a 24 V DC signal present on the terminals 17-18 for an external alarm signal. Brief description Programming Operating modes Switching hysteresis Error log memory Temperature probe The device is programmed using the front-sided buttons, in connection with the graphics display. The device can be used as: STB º Maximum or minimum monitoring with lock Reset following removal of the fault through actuation of the front-sided button or externally connected pushbutton ASTB º STW º As before, however for the monitoring of the exhaust gas temperature Maximum or minimum monitoring without lock Reset automatically on return into the permissible range Always acts in the direction of safe range. $ The last fault is stored as plain text and can be called up in the working level and deleted. The device may be operated only with temperature probes which are certified according to DIN EN 14597!

Data Sheet TT-STL50 Page 2/5 Technical data Power supply Supply voltage : 230 V AC ±10 %, 115 V AC ±10 %, or 24 V DC ±15 % Power consumption : < 4 VA Operating temperature : -10... 55 C Rated voltage : 250 V AC according to VDE0110, between input/relay output/supply voltage, degree of pollution 2, overvoltage category III Test voltage : 4 kv DC between input/relay output/supply voltage -conformity : EN55022, EN60555, IEC61000-4-2/3/4/5/6/11/13 Approvals Title EN 14597:2005 : Temperature control devices and temperature limiters for heat-generating systems EN 61508:2001 SIL2 : Functional security safety-related electrical/electronic/programmable electronic systems Input Pt100 : In the range -100.0... 600.0 C/-100... 600 C 3-wire circuit, max line resistance 5 Ω Sensor current <1 ma (no self-heating) Thermocouple Type J : FeCu-Ni in the range -100.0... 800.0 C/-100... 800 C Type K : NiCr-Ni in the range -150... 1200 C Type N : NiCrSi-NiSi in the range -150... 1200 C Type S : Pt10Rh-Pt in the range 0... 1600 C Comparison point compensation installed Basic accuracy Temperature coefficient Display Output Relay : < 0.5 %, ±1 digit : 0.01 %/K : Graphic LCD display with 128 x 64 pixels, with white back lighting : SPDT < 250 V AC < 200 VA < 2 A cos n 0.7; < 250 V DC < 80 W < 2 A Protected internally with secondary fuse 2 A, delayed Case : Polyamide (PA) 6.6, UL94V-0 DIN rail mounting TS 35 Weight : Approx. 450 g Connection : Screwed terminals 0.14... 2.5 mm² (AWG 26.. 14) Protection type : IP20, German BGV A3

Data Sheet TT-STL50 Page 3/5 Dimensions Terminals 21-28 Terminals 11-18 Terminals 41-48 Terminals 31-38 Connection diagram Supply voltage STL50-1 Reset Alarm signal 24 V max. 20 ma Supply voltage STL50-5 Reset Alarm signal 24 V max. 20 ma 11 12 13 14 15 16 17 18 11 12 13 14 15 16 17 18 21 22 23 24 21 22 23 24 Internal fuse Internal fuse A1 2 A (slow-blow) Alarm output A1 2 A (slow-blow) Alarm output <250 V AC <200 VA <2 A cosn 0,7; <250 VDC <80 W <2 A 35 36 37 38 <250 V AC <200 VA <2 A cosn 0,7; <250 VDC <80 W <2 A Pt100 45 46 47 48 Thermo couples Type J, K, N, S -

Data Sheet TT-STL50 Page 4/5 Operating and display elements Input Operating mode Actual value LED Alarm output Adjusted limit value Power-on LED Reset button Parameter button Up/Down buttons Description The operation of the device is implemented in 2 levels. The required parameter is called up with the button. The selection within a parameter and the setting-adjustment of a value is implemented with the buttons and. Button combinations (press buttons simultaneously): + 1 parameter back + Parameter is set to "0" or minimum value. After switching on the supply voltage, the device initializes itself. In the display the message indicating device type and software version is shown. After the initialization, the device is running in the working level and the current temperature, as well as all safety-relevant adjustments, are displayed. The peak value storage is called up by short activation of the button. The configuration level is called up by activation of the button for 2 seconds. In this case, all parameters which determine the properties of the device are programmed. In order to reach the security area of the configuration level, a password must be entered. If an incorrect password is entered, this appears as an error report in the display. After this signal, or even if no password has been entered, the skip-back into the working level is implemented. After entering an incorrect password three times, a security time of 60 minutes will elapse. The remaining security time is indicated in the display. With input of the correct password, the security area becomes accessible. Here adjustments can be carried out which must be protected against unauthorized change. After the last menu item, or if no button is pressed for longer than 2 minutes, a skip-back into the working level is implemented automatically and the current measured value is indicated in the display. The configuration level can be exited at any time by holding down button for 2 seconds. Error reports In case of occurring faults, the messages are shown on the display in plain text. This simplifies location of the error. Operational startup reference! The device is preset with an ex-works default setting. Therefore it must be adapted to each special application. See Page 5.

Data Sheet TT-STL50 Page 5/5 Ordering code: 1. TT-STL50 - - 2. 3. - - 4. 1. Input 1 5 2. Output 1R Pt100, 3-wire connection Thermo couples J (FeCu-Ni) K (NiCr-Ni) N (NiCrSi-NiSi) S (Pt10Rh-Pt) 1 Alarm output relay -100.0... 600.0 C/-100... 600 C -100.0... 800.0 C/-100... 800 C -150... 1200 C -150... 1200 C 0... 1600 C 3. Supply voltage 0 230 V AC 1 115 V AC 5 24V DC ±10 % 50-60 Hz ±10 % 50-60 Hz ±15 % 4. Option 00 without option - 01/07V1.1-01