SERVICE MESSAGES FRONIUS GALVO SERIES 1 ST OF SEPTEMBER 2013

Similar documents
102 AC voltage too high. 103 AC voltage too low. 105 AC frequency too high. 106 AC frequency too low

8 Troubleshooting. 8.1 Forgotten Password

SK CU4-PNT-C Part number:

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

AC SMARTMOTION CONTROLLERs

SK CU4-ECT-C Part number:

Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER

Model HM-535 Power Supply Installation and Service Instructions

INFO-PV_Inverter. User Manual INF-PVI 2000 INF-PVI 3000 INF-PVI 4000 INF-PVI 5000

Understanding printer messages

Fronius IG Plus. The next generation grid-connected PV inverter.

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

SK CU4-EIP-C Part number:

Operating Instructions

Installation and operating instructions. Solar charge controller 25 A / 40 A Z

SIOX Four I/O Mini Module

SK CU4-CAO Part number:

Troubleshooting Guide. All Vision Systems CIVCore 11 and CIVControl 11

Interpret control-panel messages

SK TU4-CAO-C Part number:

Grid Tie Solar Inverter EnerSolis Series. Three-Phase, 6 / 8 / 10 /12 kw User s Manual

RT4F-120V/20A-WAC RECTIFIER

RT4B-110V/12A RECTIFIER

Quick installation guide

SUNNA SERIES PHOTOVOLTAIC INVERTER USER MANUAL SUNNA 1500TL / 2000TL / 3000TL / 4200TL / 5000TL

Fronius Solar Electronics - product overview

Operating instructions. Solar charge controller 10 A / 15 A / 20 A / 30 A

User Manual. Solar Inverter for Water Pump

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Parameter displayed menu (SUP)

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Product and functional description

RT4F-110V/25A RECTIFIER

Installation of advanced communications board and LG Chem RESU

Pure sine wave inverter. Product Manual

Hardware Manual RM Display 2501 S01..S04

User Manual. 3KW/5KW PV Inverter

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

GCI-2G-W Single Phase Inverter

PEM Faults and Blower Failures

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

Smart Grid Tie Microinverter User Manual

Hardware Manual RM Display 2401

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

ME3 Mobile Cabinet Three Phase Frequency Converter, Operation and Maintenence.

FS Series PV Modules Reverse Current Overload

central inverters certificate of Factory inspection Sirio Central inverters meet Made in EU criteria as they are designed, manufactured

RT4F-48V/50A-WAC RECTIFIER

User Manual Software for DSL Digital Speed Switch

Operating Manual. Micro-Ohmmeter VG - CS200 VG - CS300 VG - CS400 VG - CS600

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER

Vector Drive - Troubleshooting Guide

Unico 2400 Drive Faults Descriptions and Causes Dec. 2016

Sunny Boy 2100TL Transformerless solar inverter Installation Guide

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Control-panel messages

VersaMax IP I/O Module

FRONIUS IG. PV Central Inverter

FRONIUS IG. PV Central Inverter

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Operating instructions Evaluation system for flow sensors VS / / 2013

-5K-2G. Solar PV Grid Tie Inverter. inverter. Installation and Operation Manual. 2013, Ningbo Ginlong Technologies Co., Ltd.

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

Understanding printer messages

USER MANUAL INSTALLATION AND OPERATION

ISMG Solar Inverter. General Description. Type Selection. Ordering Key ISMG 1 50 EN. Approvals RD 1663/2000 RD 661/2007 DK5940 VDE

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1

Operating and installation instructions Differential pressure monitor

Troubleshooting. General System Checks. Troubleshooting Components. Send documentation comments to

SK TU4-PBR Part number:

Smart Grid Tie Microinverter User Manual

R-net Error Code List

Solis Single Phase Inverter

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Hybrid AC Driver [GCNC-1110]

16-Channel Digital Output Module 120Vac/dc

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

IPC194. ipconv Protocol Converter

3D SYSTEMS University Cube 3D Printer

Solis Single Phase Inverter

SK CU4-PBR-C Part number:

Description TR D

Digital DRIVE for Brushless motor MD Serial

User manual Technical parameters

RTK3 Logic Controller User Manual Revised

Vector Drive - Troubleshooting Guide

Communicative controller for VAV systems

Installation and Operations Manual INVOLAR MAC250 Microinverter

Vector Drive - Troubleshooting Guide

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

Trouble Shooting. Symptoms: Gate Access Control Computer connected to the Facility Computer

PV Rapid Shutdown device

GTI 300W GTI 500W GTI 600W GTI 800W GTI 1000W

High Efficiency LED Driver DCCP-DPR Series USER MANUAL. This manual offers important information and suggestions with

vacon nx ac drives brake chopper unit (bcu) application user s manual

Troubleshooting Initial Startup Problems

User Manual TRB4000TL/TRB5000TL/TRB6000TL/TRB8000TL/TRB9000TL/ TRB010KTL

First of all, thank you for purchasing R2W series redundant power supply.

Transcription:

SERVICE MESSAGES FRONIUS GALVO SERIES 1 ST OF SEPTEMBER 2013 Dear Fronius customer! These state codes will help you to ascertain errors of the FRONIUS Galvo inverters, the photovoltaic system as well as installation and operation errors, and if possible how to repair on site. Service class 1 These errors usually occur only temporarily and are caused by the public mains. The inverter reacts by disconnecting from the public mains and attempts to switch on again after the specified mains monitoring period. If there is a further grid fault, the monitoring counter will be reset. The error code is displayed whilst the public mains is being checked. 08/2013 1/11

102 Grid voltage above permitted limit 103 Grid voltage below permitted limit 105 106 107 Mains frequency above permitted limit Mains frequency below permitted limit Synchronisation with the public mains supply not possible 108 Islanding detected 1. Mains voltage error 1. Check mains voltage 2.Incorrect values in the Service Menu / Wrong Setup 2. Check values in the Service Menu / Check Setup 3. Measuring error on the power stack 3. Change power stack 1. Mains voltage error 1. Check mains voltage 2. Incorrect values in the Service Menu / Wrong Setup 2. Check values in the Service Menu / Check Setup 3. Measuring error on the power stack 3. Change power stack 1. Mains frequency error 1. Check mains frequency 2. Incorrect values in the Service Menu / Wrong Setup 3. Measuring error on the power stack 2. Check values in the Service Menu / Check Setup 3. Change power stack 1. Mains frequency error 1. Check mains frequency 2. Incorrect values in the Service Menu / Wrong Setup 2. Check values in the Service Menu / Check Setup 3. Measuring error on the power stack 3. Change power stack 1. Incorrect values in the Service Menu / Wrong Setup 2. Bad contact of the power stack with AC 1. Check values in the Service Menu / Check Setup 2. Check AC connector screws 3. Bad AC connection 3. Check mains connection 4. Measuring error on the filter board 4. Change filter board 5. Measuring error on the power stack 5. Change power stack 1. Islanding detected 1. Automatic correction 2. Severe disturbances in public mains 3. Grid Impedance out of permitted values 4. Bad contact of the power stack with AC 2. Automatic correction 3. Contact Utility 4. Check AC contact screws 5. Bad AC connection 5. Check AC connection 6. Measuring error on the power stack 6. Change power stack 08/2013 2/11

Service class 3 This group summarises Fronius Galvo error states that can occur during feed in operation. However these do not indicate damaged electronics and do not lead to a remaining interruption of the feed in operation. After switching off and passing the grid monitoring period, the Fronius Galvo starts feed in operation again. In case of a temperature excess, an additional cooling down phase is maintained. 301 302 Current peak on the mains supply detected Current peak on the PV generator detected 1. Voltage drop on the public mains 1. Automatic correction 2. Grid Impedance out of permitted values 3. Bad contact of the power stack with AC 2. Contact Utility 3. Check AC connector screws 4. Measuring error on the power stack 4. Change power stack 1. Voltage drop on the public mains 1. Automatic correction 2. Bad contact of the power stack with DC 2. Check DC connector screws 3. Measuring error on the power stack 3. Change power stack 1. Ventilation opening blocked 1. Clean openings 2. Too high ambient temperature 2. Change mounting place 303 Too high heat sink temperature 3. In- or Outside fan cable not connected 3. Connect fan cable 4. In- or Outside fan defect 4. Change fan 305 Feed-in process not possible, even though public mains parameters within limits 5. Measuring error on the power stack 5. Change power stack 1. Loose connection on the mains cables 2. Bad contact of the power stack with inductor 1. Connect mains cables properly 2. Check inductor screws 3. Measuring tolerances too small 3. Update Software 4. Grid Impedance out of permitted values 4. Contact utility 5. Defective AC relays (L1 or N) 5. Change power stack 306 POWER LOW 1. DC-power is too low for feeding in 1. Wait for more irradiance or check modules 2. Measuring error on the power stack 2. Change power stack 1. DC main switch open 1. Close DC main switch 307 DC LOW 2. PV generator not connected 2. connect DC generator 3. DC-voltage too low for feeding in 4. reversal voltage of PV generator 3. Wait for more irradiance or check modules 4. reverse polatity of PV generator 5. Measuring error on the power stack 5. Change power stack 308 The intermediate circuit voltage has exceeded the max. permissible range 1. Voltage drop on AC grid 1. Automatic correction 2. Measuring error on the power stack 2. Change power stack 309 Too high DC voltage 1. PV generator voltage too high 1. Check PV configuration 2. Measuring error on the power stack 2. Change power stack 08/2013 3/11

Service class 4 Errors from this class require intervention from a technician to remedy them. They are either temporary or lasting and are triggered by faulty hardware or a software problem. 401 406 Communication error between Recerbo and power stack Temperature sensor in DC semiconductor module defect or no communication with DSP 1. Ribbon cable between power stack and filter board faulty or not connected properly 1. Check ribbon cable between Recerbo and power stack 2. Ribbon cable defect 2. Change Ribbon Cable 3. Filter board defect 3. Change Filter board 4. Recerbo defect 4. Change Recerbo 5. Power stack defect 5. Change power stack 1. Defective temperature sensor in semiconductor module 1. Change power stack 2. Defective circuit on the power stack 2. Change power stack 1. Defective temperature sensor on the power stack 1. Change power stack 407 Temperature sensor on the power stack defect or no communication with DSP 2. Defective circuit on the power stack 2. Change power stack 408 On the inverter an unacceptably high DC injection was detected 1. Asynchronous AC grid 1. Check AC grid 412 416 Adjusted Fix-voltage beyond the accessible MPP range 1. Fix voltage was adjusted too high or too low 1. Check adjustments in the Service menu 2. Ribbon cable between Recerbo and 417 2. Change ribbon cable power stack defect Communication error between power 419 stack and Recerbo 421 4. Power stack defect 4. Change power stack 425 427 1. No connection to AC grid 1. Check AC grid 428 Power stack Timeout Error 2. Software error 2. Update software 429 3. Measuring error on power stack 3. Change power stack 08/2013 4/11

431 Power stack is in boot mode 432 433 436 Consistent error in power stack management Allocation error of dynamic addresses Problem while error transmitting of the power stack 1. Power stack will be programmed by the Recerbo automatically 2. Power stack can t be programmed automatically 2. Software update 3. Filter board defect 3. Change Filter board 4. Recerbo defect 4. Change Recerbo 5. Power Stack defect 5. Change power stack 1. Power stack couldn t communicate with the Recerbo 1. Restart inverter or do a software update 1. Power stack couldn t communicate with the Recerbo 1. Restart inverter or do a software update 1. Power stack can t communicate with the Recerbo 1. Restart inverter or software update 437 438 Problem with the internal error handling Problem while error transmission from power stack to Recerbo 1. Power stack can t communicate with the Recerbo 1. Restart inverter or software update 1. Power stack can t communicate with the Recerbo 1. Restart inverter or software update 443 DC/DC energy transfer failure 1. Bypass relay sticks 1. Change power stack 445 450 Country setup information faulty Monitoring problems of Power Stack processor 1. Country setup information faulty 2. Old softwareupdate 1. Do a software update and reload country setup from Setup menu 2. Do a software update and reload country setup from Setup menu 1. No communication between power stack and FIL possible 2. Defective ribbon cable Filter board - Power Stack 2. Change Ribbon cable 3. Defective Filter board 3. Change Filter board 4. Defective Guard 4. Change power stack 1.Grid problem 451 Flash of the Guard defect 2. Defective AC Guard on Filterboard 2. Change Filter board 3. Defective AC Guard on Power stack 3. Change power stack 1.Grid problem 452 Communication between Filter & power stack faulty 2. Defective AC Guard on Filterboard 2. Change Filter board 3. Defective AC Guard on Power stack 3. Change power stack 08/2013 5/11

1.Grid problem 453 Processor Guard detected a faulty grid voltage 2. Defective AC Guard on Filterboard 2. Change Filter board 3. Defective AC Guard on Power stack 3. Change power stack 1.Grid problem 454 Processor Guard detected a faulty grid frequency 2. Defective AC Guard on Filterboard 2. Change Filter board 3. Defective AC Guard on Power stack 3. Change power stack 456 Error in the Anti - Islanding monitoring detected 2. Measuring error on Filter board 2. Change Filter board 3. Measuring circuit for Anti - Islanding defect 3. Change power stack 457 Grid Relais don't release 459 faulty Isolation Measurement 2. Relais stucks 2. Change power stack 2. Isoaltion Measuremenet defective 2. Change power stack 460 Reference voltage outside permitted limits 2. Measuring circuit on power stack defect 2. Change Power stack 461 Defective data memory 1. Defective power stack 1. Change power stack 462 Failure on the DC injection monitoring detected 2. DC injection monitoring defect 2. Change power stack 472 defective grounding fuse 475 Isolation failure detected 1. defective grounding fuse 1. Change grounding fuse 2. wrong settings in Service Menu Basic 2. set DC Mode to "floating" 1. PV generator grounding error 1. Check PV generator 2. Measuring circuit on power stack defect 2. Change Power stack 476 Internal Power supply missing 1. Defective internal power supply 1. Change power stack 480 Power Stack software incompatible to display software 1. Old power stack software 1.Software update and reload setup 481 Cerbo has old SW version 1. Old Cerbo software 1.Software update and reload setup 482 inverter switched off during commissioning 1. Startup Prcedure not succesfule 1.Restart inverter 08/2013 6/11

Service class 5 Generally this class does not stop the feed in operation of the Fronius Galvo. The state codes will be displayed until the message is acknowledged by pushing a button on the display (the inverter will work in feed in operation during this time). 502 An isolation fault between DC+ or DC- to earth has been detected 509 No feed in operation for 24 hours 516 Communication error inside the power stack 1. Isolation fault at the solar generator 1. Snow covered or very dirty modules 2. Insufficient power from the modules for feed in operation 1. Check cables and solar generator 1. Clean modules or remove snow 2. Check other service codes 1. Ventilation opening blocked 1. Clean openings 2. Too high ambient temperature 2. Change mounting place 3. Fan cables not connected 3. Connect fan cables 517 Power stack Derating caused by too high temperature 4. Fans defect 4. Change fans 5. Filter board defect 5. Change filter board 6. Recerbo defect 6. Change recerbo 7. Measuring error on the power stack 7. Change power stack 519 Communication error inside the power stack 1. Occurs once 2. Filter board defect 1. Restart Galvo 2. Change Filter board 551 Defect module grounding fuse 1. Module grounding fuse defect 2. Isolation fault on the PV generator 3. Wrong settings for Isolation measuring 558 Country setup not supported 1. Old power stack software 560 Power reduction because of over frequency 1. Check or replace the module grounding fuse 2. Check cables and solar generator 3. Change Settings in Ground Mode 1.Software update and reload setup 1. Too high grid frequency 1.Automatically corrected 08/2013 7/11

Service class 7 State codes of the class 7 affect the controlling, the configuration and the data logging of the inverter. It can affect the feeding in directly or indirectly. 701* LN Nodetype out of range 702* Recerbo Buffer full 703* LN Send Buffer full 1. wrong LN number 1. Insert LN number again 2. EEPROM defect 2. Change inverter 1. Problems with LN ring 1. Check LN ring 2. Recerbo defect 2. Change Recerbo 1. Problems with LN ring 1. Check LN ring 2. Recerbo defect 2. Change Recerbo 705 LN number exists 2 times 1. LN number exists 2 times 1.Change LN number 706* key controller communication failed 707* EEPROM communication failed 2. Recerbo defect 2. Change Recerbo 2. Recerbo defect 2. Change Inverter 711* EEPROM Error 1. Recerbo defect 1. Change Inverter 712* failure while writing on EEPROM 714* 715* failure while reading from EEPROM 2. Recerbo defect 2. Change Inverter 721 Failure while writing on EEPROM 2. Recerbo defect 2. Change Inverter 722* 723* 724* failure while reading from reading to EEPROM 2. Recerbo defect 2. Change Inverter 725* 726* 727* EEPROM backup defective 730* 2. Recerbo defect 2. Change Inverter 1. USB Stick Read/Write protected 1. Remove Read/Write protection 731 732 733 Failure while initialising, USB Stick wasn t detected Failure while initialising, USB Stick has a too high current No USB Stick inserted, although there should be 2. USB Stick not detected 2. Format USB Stick 3. USB Stick not supported 3. Use another USB Stick 4. Access time of the inverter too fast 4. Update software 1. USB Stick ineligible due to too high current 1. Use another USB Stick 1. No USB Stick inserted 1. Insert USB Stick 2. Unplugged USB Stick while updating 2. Reconnect USB Stick and start update again 08/2013 8/11

734 Update file not identified 735 For this inverter no fitting update is on the Stick 1. Update file has wrong format 1. Name update file correctly (correct : Froxxxxx.upd, xx. Continuously number) 2. Update in the wrong file 2. Store update on outer directory 1. Old or defective update on the USB Stick 1. Load new update on the Stick 2. Updatefile from Agilo or TL inverter 2. Use the correct updatefile 1. Incorrectly formatted USB Stick 1. Format USB Stick with FAT 32 736 Read or write error appeared 737 Update file couldn t be opened 2. USB Stick secured with a password 2. Delete password protection 3. Read or write protection on the USB Stick 3. Delete read or write protection 1. Defective update file 1. Load new update on USB Stick 2. Failure while formatting 2. Format USB Stick 1. Incorrectly formatted USB Stick 1. Format USB Stick with FAT 32 738 Creating a Logfile is not possible 740 Failure while initialising 2. USB Stick secured with a password 2. Delete password protection 3. Read or write protection on the USB Stick 3. Delete read or write protection 1. Failure in the USB Stick format 1. Format USB Stick 2. Defective USB Stick 2. Use another USB Stick 1. Memory on USB Stick full 1. Delete data from USB Stick 741 Failure while writing on USB Stick 743 Update failed 2. Memory on USB Stick too small 2. Use a bigger USB Stick 3. USB Stick unplugged while writing 4. Mains voltage drop out while writing 4. Check grid 3. Reconnect USB Stick and start update again 5. Invalid data 5. Format USB Stick 1. Unplugged USB Stick while updating 1. Reconnect USB Stick and start update again 2. Update failed 2. Restart update 745 Checksum test failed 1. File on USB Stick is defective 1. Format USB Stick 746 Incompatibility between some boards 751 Lost real time clock 752 No response from real time clock 1. Some Boards didn t start completely yet 1. Wait 1 minute with the update 2. Print data of some Boards are incompatible 1. IG Galvo had no AC connection for longer than 5 days 2. Send IG Galvo back to Fronius 1. Set time 2. Memory on the Recerbo defective 2. Change Recerbo 2. Defective Recerbo 2. Change Recerbo 754* 755* 757 758 Time set Time can t be stored, due to safety reasons the inverter doesn t feed in RTC Quarz in emergency operation 1. time /date has been set 1. Defective real time clock 1. Change Recerbo 2. Recerbo defect 2. Change Recerbo 08/2013 9/11

760 Systemquartz defect 761* 762* Reading error of onboard storage print Reading error of attached storage print 2. Recerbo defect 2. Change Recerbo 1. Onboard storage print is missing 1. Change interface board with the one containing the onboard storage print 2. Defective ribbon cable 2. Change ribbon cable 3. Onboard storage print defect 3. Change Galvo 4. Recerbo defect 4. Change Recerbo 1. Attached storage print is missing 2. Attached storage print is defective 1. a.usage of original Recerbo: State Code is insignificant!!!!! b.usage of exchange Recerbo: attach the original storage print 3. Recerbo defect 2. Change Recerbo 3. Change Galvo 763* Power limitation of the Onboard storage print not readable 1. Onboard storage print is missing 1. Attach the original storage print 2. Onboard storage print defect 2. Change Galvo 3. Recerbo defect (in combination with State 761) 3. Change Recerbo 1. Onboard storage print is missing 1. Attach the original storage print 764* 765* Power limitation of the attached storage print not readable Recerbo can t read power limitation 766 No Power limitation found 767* Power limitation not readable 768 772 Power Limitation while feeding in operation changed Memory on the storage print not available, due to safety reasons the inverter doesn t feed in 2. Onboard storage print defect 2. Change Galvo 3. Recerbo defect (in combination with State 761) 3. Change Recerbo 1. Recerbo defect 1. Change Recerbo 1. Recerbo defect 1. Change Recerbo 2. Interface board defect 2. Change Interface board 3. Onboard or attached storage print defect 3. Change Galvo 2. Recerbo defect 2. change Recerbo 1. Attached storage print is being connected or disconnected during feeding in operation 1.Ribbon cable defect 2.Memory on Interface board defect (State code must be confirmed) 1. Check ribbon cable between Recerbo and Interface board 2. Change Interface board 1. Memory not programmed or memory lost 1. Reload setup 773 775 Memory on the storage print not initialised, due to safety reasons the inverter doesn t feed in Faulty programming of the power stack 776 Wrong inverter type stored 2. Defective Recerbo 2. a. Exchange Recerbo: change Storage print 2.b. Original Recerbo change Galvo 1. Power stack not programmed 1. Change Galvo 1. Inverter type lost 1. Update inverter 2. Inverter type on storage print and Recerbo lost 2. Change Galvo 08/2013 10/11

782* 783* 784* 787* Error during update 789* 2. Recerbo defect 2. Change Recerbo 792* 794* 1000* - 1210* Service-messages Are harmless for a faultless feeding in process and gives information about the internal Processor Status. *...Code appears only with Eventlogging and in the Error Counter Fronius TechSupport International Tel.: +43 (7242) 241 5670 pv-support@fronius.com Visit our web site under www.fronius.com 08/2013 11/11