Wire Communications Design jfm 07. An Inside Look at Outside Plant

Similar documents
Chapter 1 Introduction to Outside Plant

Maximizing Pathways in The Outside Plant

FIBER OPTIC HARDWARE STEVE PAULOV

ANSI/TIA/EIA-568-B Cabling Standard

MICHIGAN DEPARTMENT OF TRANSPORTATION

Computer Network Design Guide Existing Systems 1 / 6

Understanding OSP Engineering & Planning Outside Plant

BROWARD COUNTY AVIATION DEPARTMENT INSIDE PLANT INFRASTRUCTURE SPECIFICATIONS

The six major components of a structured wiring system are:

Communications. UNM IT/Telecommunications Guide Specification Communications

Copper Riser And Intrabuilding Cabling

f) Telecommunications Equipment Rooms

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

17. Microwave Collocation 17.1 General

INTERNATIONAL STANDARD

ANSI/TIA/EIA-568-B Cabling Standard NOTE

Cabling a Data Center to TIA-942 Standard

Telecommunications Structured Cabling Systems

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

SECTION COMMUNICATIONS BACKBONE CABLING

Communication

INSTALLATION INSTRUCTIONS

Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector

Construction Guidelines. for Providing Communications Services

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

ICS Entrance Management Sign Installation Guide. Version 1.0

Meter Enclosure and Equipment Standards

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

MICHIGAN DEPARTMENT OF TRANSPORTATION

Satellite INSTALLATION GUIDE

Miniature outside plant plug-and-play solutions. White paper

Optimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit

Los Angeles Community College District Design Standards

Target Interface / Construction Compliance Inspection Checklist

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

Master Format Division 27 - Communications

BACKBONE CABLING. Structured Cabling Systems. Entrance Closet. Telco Closet. Intermediate Cross Connect. Telco Closet. Main Cross Connect.

Tarleton State University. Specifications

NZQA unit standard version 2 Page 1 of 5

NZQA unit standard version 2 Page 1 of 5

Karvo Paving Company Hudson Drive Stow, OH Unit Price Labor & Material Total Unit Price Labor Unit Price Material

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF TRAFFIC SIGNAL CONTROLLERS

White Paper. Re-enterable Plug and Play Fiber Access Terminals. ABSTRACT INTRODUCTION COMMON TYPES OF FIBER ACCESS TERMINALS

CiAC A239AXXX Sealed T1 Mini-Repeater

Element Z General Design Requirements Owner Standards and Other Requirements

Customer Training Catalog Training Programs Outside Plant

SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS

1995 Metric CSJ 's & SPECIAL PROVISION ITEM 4. Scope of Work

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Data Center Design and the ANSI/TIA-942 Standard

Current Control Houses

Fall Test 21 due 12/11/2012

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Cable TV, Broadband, Telephone, and Security

Aerial. Pedestal. Outside Plant: Buried Fibre

Indoor Protected Entrance Terminal 4588 Series

SECTION 2 DIVISION 27 UNC CHARLOTTE ITS DEPARTMENT. ITS Telecommunications Standards - Specifications Manual for Construction and Renovations

FieldShield YOURx Platform:

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

Charles Multi-Purpose Housings (CMPH)

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

Installation Notes TII Model 341 Protector

SPECIAL PROVISION Scope of Work

ANSI/TIA/EIA-568-B A P P E N D I X TECHNICAL INFORMATION. Contents ANSI/TIA/EIA-568-B. anixter.com

DELAWARE COUNTY SECONDARY ROAD DEPARTMENT POLICY AND PROCEDURE MEMORANDUM

Next Generation Cross-Connect NCX-1000 Small-Size Service Delivery Cabinet User Manual

Target Interface / Construction Compliance Inspection Checklist

PN Telecommunications Infrastructure Standard for Data Centers Draft 2.0 July 9, 2003

COMMISSION POLICY POLICY #9.16

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

BANK ON CLEARFIELD

SPECIAL SPECIFICATION 6027 Lane Control Signal Equipment

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

Target Interface / Construction Compliance Inspection Checklist

G/Comms. Brian Mckelvey September 17, 2008 Winnipeg, Canada

Atras Network Communications

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

Spring Test 9 due 05/11/2013

Classroom WiFi Network Infrastructure Plan

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Structured Cabling Guidelines For The State Of Oregon

PAR+ & MSC+ Controller. Installation Manual

iconverter 2-Module Power Chassis

TAIHAN ELECTRIC WIRE CO.,LTD. FTTH Connectivity Material Presentation

Hands-On Outside Plant Intro-Level Technician

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

FTTX Solutions. Multiport Service Terminal (MST) and Hardened Drop Cables. Benefits:

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Leveraging Fiber Properties to Our Advantage

Andrew Afflerbach P.E., Ph.D UTC Rural Broadband Workshop July 21, 2014

Sapling Converter Box

Fiber Optic Technician - Outside Plant (FOT-OSP) Course Description. Certification(s) Students Will Learn. Splicing Overview & Testing Outside Plant

Transcription:

An Inside Look at Outside Plant

BICSI Region Meeting 2007 Agenda What is CO-OSP? A close look at the 758-A standard Available Resources

What is CO-OSP? Customer Owned Outside Plant Telecommunications infrastructure designed for installation exterior to buildings ANSI/TIA/EIA-758-A terminology

CO-OSP Standard ANSI/TIA/EIA-758-A (2004) Customer-Owned Outside Plant Telecommunications Infrastructure Standard. This standard replaces the ANSI/TIA/EIA-758 and 758-1 documents. (1999)

Why do I have to know these standards? You have to know these standards if: You do work on customer owned property You d like to give your customer a system that will work regardless of the electronics they choose

LET S TAKE A LOOK INSIDE THE CO-OSP STANDARD ANSI/TIA/EIA-758-A Customer-owned Outside Plant Telecommunications Infrastructure Standard

Discussion of the contents! Introduction and Scope Definitions, Acronyms, Weights, and Symbols Cabling Infrastructure Pathways and Spaces Cabling Hardware Annexes

INTRODUCTION Customer owned campus facilities are typically termed outside plant In this standard they re called Customer-owned OSP

INTRODUCTION Two categories of criteria are specified: Mandatory and Advisory Terms Mandatory word is SHALL Advisory words are SHOULD, MAY, and DESIRABLE

INTRODUCTION Mandatory criterion applies to performance and compatibility requirements Advisory criterion is above minimum goals.

Introduction Metric dimensions are soft conversions of US units (100mm soft converts to 4 inches) Conduit dimensions are listed as follows: 21 (3/4) trade size conduit That s 21mm and/or 3/4 (You won t see the mm or in)

INTRODUCTION The standard is a living document which means it can be revised or updated due to advances in construction techniques or technology.

SCOPE-Applicability The standard specifies minimum requirements for CO-OSP Specifies cabling and the pathways and spaces to support it Useful life of OSP Pathways and Spaces is 40 years Useful life of OSP Cabling is 30 years

Scope - Applicability Now isn t that convenient! The useful life of pathways is 40 years The useful life of the OSP cable is 30 years The useful life of an OSP engineer is 29 years 364 days

SCOPE- Pathways and Spaces There are two basic types of cable pathway systems: Underground and Aerial

SCOPE Underground Pathways and Spaces Direct Buried Buried Duct/Conduit Maintenance Holes, Handholes Shared Spaces (utility tunnels)

SCOPE- Pathways and Spaces Aerial Pathways and Spaces Poles Messenger Wire or Strand Anchoring Guy Wires Anchors

SCOPE- Customer Owned OSP Cabling Consists of recognized cable Conforming connecting hardware Protective Devices which. Can be located on the exterior or interior of a building or in an outdoor pedestal or cabinet

SCOPE- Customer Owned OSP Cabling Can have intermediate splices Fiber Optic Cabling may pass through a building entrance facility as part of the cable route Star topology recommended

Normative References The standard references 54 other standards and codes which, by reference, constitute part of the standard

TERMS AND DEFINITIONS The CO-OSP standard contains: 77 definitions 49 acronyms 14 weights and measures 59 symbols

TERMS AND DEFINITIONS Let s look at one definition Entrance facility (telecommunications): An entrance to a building for both public and private network service cables, (including wireless), including the entrance point of the building and continuing to the entrance room or space.

Terms and Definitions For most service providers (SP) or access providers (AP), that represents a change to the ways we learned. The entrance facility was the place in the building we stopped our cable and terminated it.

CABLING INFRASTRUCTURE Topology Recommended topology is a star Large Campuses use a hierarchical star Stars offer centralized management and administration Distance limitations may prohibit the use of a star topology

CABLING INFRASTRUCTURE Recognized Cables 50/125 optical fiber cable 62.5/125 optical fiber cable Singlemode optical fiber cable 100 ohm Twisted Pair Cable 75 ohm Coaxial Cable

CABLING INFRASTRUCTURE Media Selection Choose the cable considering: Characteristics of the applications Distances Future growth (population) Customer preference Required useful life Flexibility with respect to supported services

CABLING INFRASTRUCTURE Bonding and Grounding A critical component of design Protects people and property Improper bonding and grounding can affect other telecomm circuits Comply with ANSI-J-STD-607-A, The National Electrical Safety Code (NESC ) and National Electrical Code (NEC )

CABLING INFRASTRUCTURE Bonding and Grounding POOR or incomplete Bonding and Grounding can create: Equipment malfunction or failure Insurance issues you don t want Injury or death to personnel Noise on voice circuits Loss of manufacturer s warranty

PATHWAYS AND SPACES Pathways may be aerial, direct buried, or underground. Underground or direct buried is preferred over aerial Underground is preferred over direct buried

PATHWAYS AND SPACES Subsurface Pathways Design should consider: Excavation - Clearances and separations, Depth, Backfill, and Restoration, Trenching, Boring, Plowing. Street Crossings, Casings.

PATHWAYS AND SPACES Conduit/Duct EB Type - Encasement in concrete DB Type - Direct Buried or encased Rigid Non-Metallic Sched. 40 or 80 MPD- Multiple Plastic Duct Rigid Metallic Conduit IMC- Intermediate Metallic Conduit Fiberglass Duct - DB or encased Inner duct - PE or PVC Note- The NEC says metal not

metallic

PATHWAYS AND SPACES Conduit/Duct Encase bends (non-metallic) 600 ft max. between pulling points No more then (2) 90 s or a total of 180 degrees Drain slope should be is 1/8 per foot: Exiting or entering a building or from the middle of a conduit span (each way)

PATHWAYS AND SPACES Innerduct may be placed within a duct to facilitate initial and subsequent placement of multiple cables in a single duct. Note- Innerduct can be plastic or fabric textile duct

PATHWAYS AND SPACES Subsurface Considerations Duct plugs on ALL conduits Axial Movement- Bridge Crossing Tunnel Requirements OSHA Sheath properties and clearances

PATHWAYS AND SPACES Aerial Construction Consider: Pole class, length, type, depth. All loading factors Grounding, clearances, separation Anchors/guys, riser protection Span lengths, slack spans, etc. Lashing, strand tension, sag.

AERIAL CONSTRUCTION Poles commonly used in the telecommunications world are: Height- 30, 35, 40 or 45 Class- 9 classes 1 thru 10 (Class 8 was eliminated) Most common - 3, 4, 5, 6, 7

PATHWAYS AND SPACES Maintenance Holes Location considerations: Terrain (Topography) Soil Conditions Surrounding Structures Personnel Access Placing and Splicing Ease

PATHWAYS AND SPACES Maintenance Holes Maximum distance shall not exceed 600 feet Not within 50 of curb radius at an intersection In the right of way but outside the traveled portion (if placed within the traveled portion then 5 feet from the curb)

PATHWAYS AND SPACES Maintenance Holes Concrete, steel, or cast iron Must have proper load ratings Can be pre-cast or site poured May have multiple openings

PATHWAYS AND SPACES Maintenance Holes Maintenance holes shall be equipped with: Corrosion resistant pulling irons Corrosion resistant cable racks Sump for drainage and..

PATHWAYS AND SPACES Maintenance Holes SHALL NOT BE SHARED WITH ELECTRICAL INSTALLATIONS (other than those needed for telecommunications equipment)

PATHWAYS AND SPACES Maintenance Holes TYPES A - end wall entrance only B - handhole J - end and sidewall entrance V - one end wall and two side walls

PATHWAYS AND SPACES Maintenance Holes Covers shall meet the environmental conditions Heavy Vehicle Traffic Lighter Loads Sidewalk

PATHWAYS AND SPACES Handholes (Advanced Warning) The slide you are about to see may cause nausea, disbelief, glazed vision, or create some serious doubt about your presenter s credibility.

PATHWAYS AND SPACES Handholes Shall not be used in place of a MH Shall not to be used for splicing Shall not be shared with electrical Shall not exceed a 4 X 4 X 4 Should not be used in runs of more than (3) 4 conduits Should align conduits on opposite walls at the same elevation

PATHWAYS AND SPACES Pedestals and Cabinets Should accommodate 4 cables Cable bend radii not less then 15 times the diameter of the cable Corrosion Resistance Customer Preferences Meet ASTM requirements

PATHWAYS AND SPACES Pedestals and Cabinets Resistant to rodent and insects Secure - Locks, special bolts, etc. Chemically resistant Grounding and bonding to Codes

PATHWAYS AND SPACES Other Spaces Vaults: Are open or closed bottom housings which provide grade level or below grade level environmental protection, access, and security to splices, cable, and distribution equipment.

PATHWAYS AND SPACES Vault Selection Concerns Cable bend radii (15x cable) Accommodate four cables Accommodate both inline and butt splices Secure with locks, bolts, etc Provisions to relocate if needed Resistant to rodents/insects

PATHWAYS AND SPACES Traffic Loadings Maintenance Holes and Vaults have three basic load ratings H-5 Sidewalk applications (11K lbs..) H-10 Driveways/Parking Area (22K) H-20 Heavy Traffic (40K)

CABLING Twisted Pair Cable 19, 22, 24, or 26 AWG Meet all ANSI/ICEA requirements Recommended applications for Filled and Air Core cables (R,S,N) Meet AHJ and applicable codes

CABLING Twisted Pair Specifications Filled cable is recommended (R) for aerial, direct buried, and UG. Air Core is suitable (S) for aerial and UG and not recommended (N) for direct buried.

CABLING Connecting Hardware Withstand temperature range of -40 degrees F to 158 degrees F Can be plastic or metal Must meet requirements of ANSI/TIA/EIA 568-B Terminal blocks must allow access to test points without disconnecting the service drop or puncturing the insulation