MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

Similar documents
Air-insulated medium-voltage secondary distribution switchgear

Innovation on Medium Voltage Switchgear

UniSec, MV AIS for Secondary Distribution Smart Grid applications

Medium Voltage Air Insulated Switchgear for Secondary Distribution Product overview

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

DISTRIBUTION SOLUTIONS. UniGear ZS1 Medium-voltage air-insulated switchgear up to 24 kv

DISTRIBUTION SOLUTIONS. ZS8.4 Medium-voltage air-insulated switchgear

ABB AG - EPDS. Gas-insulated switchgear Type ZX2

CENTERLINE 2500 Motor Control Centers

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1

Medium Voltage Products. UniGear ZS2 36 kv, 3150A, 31.5 ka Medium voltage, arc-proof, air insulated switchgear

Refurbishment of Switchgear and Switchgear Devices

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Grid Automation packaged solutions Optimal automation of medium voltage grids

1. Coordination of series-rated devices is permitted where indicated on Drawings.

MNS ACS880 Switchgear mounted industrial drives

Electrical Integration with Smart Communication

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

TRENDS IN SWITCHGEAR SPECIFICATIONS

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Susol LV Switchgear. Susol Low Voltage Switchgear & Motor Control Center

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

MNS & MNS is Low Voltage Switchgear Safety Aspects

Medium voltage products. UniGear kv, arc-proof, air insulated switchgear for power applications

Benefits, offering and references

Circuit Breakers,Reclosers, Switches, and Fuses

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Innovation for MV distribution

MESP TECHNICAL SPECIFICATION FOR 22 kv METAL ENCLOSED SWITCHGEAR

IEC & 2 standard. The reference for safe and reliable LV switchboards

Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

ABB Data Center Forum 2017

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Package Substation. The efficient solution for your electrical distribution network

VAMP 221. Table of Contents

Mitigating Arc Flash Hazards

Product brochure. UniGear 550 Medium voltage, arc-proof, air-insulated, metal-clad switchgear

High Safety low voltage switchgears For maximum requirements far beyond all standards.

11 kv Indoor Switchgear - SCADA Controlled

Explanations on the Concept of IEC Fit for the Future with SIVACON!

Adaptors Busplug Low Voltage Switchboard Equipment

Solid-State Switching Devices

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo

ABB Digital medium-voltage switchgear

Ground Breaking MV Switchgear

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Installation Job Aid for VSP 4850GTS

IEC An introduction. 28 March 2012 By Craig McKee Technical Manager

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Medium Voltage Service Course Description Training Course CZ045 Operation and maintenance of UniGear ZS1 with VD4 and REF 620

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Catalog. Arc Guard System TM TVOC-2

DOC Electrical Installation Calculation and Dimensioning

SIEBREAK-VCB 5-15 kv metal-enclosed interrupter switchgear usa.siemens.com/siebreak

Room Temperature Controller

Document C0. Use for:

Certification Exams. Detailed Content Outlines Level 2 Certified Assistant Technician Level 3 Certified Technician Level 4 Certified Senior Technician

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

CFD, IEC STANDARDS AND TESTING LABORATORIES: JOINING THE PIECES FOR HIGHER QUALITY HV EQUIPMENT. Cognitor Consultancy, Research and Training Ltd.

Prisma Plus System P Cubicles up to 4000 A

ASCO 7000 Series IEC Medium Voltage Power Transfer Switches

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

UniGear type ZS1. SSC (Switchgear System Connectivity)

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Type VR Electrically Operated Ground and Test Device

Securing your power supply

Document Title Issue Date. TBE/KBE-DOC TBE/KBE Document List TBE/KBE-REV TBE/KBE Revision List

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

17 th Edition (BS 7671:2008) incorporating Amendment No 1

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Model 2657A-LIM-3 LO Interconnect Module

Power Transmission Division Link between power generation and distribution

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

Fundamentals of Circuit Breaker Maintenance. AVO Training Institute, Inc. 2018

Installation Job Aid for VSP 4450GTX-HT- PWR+

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

SECTION SWITCHGEAR

Intelligent Medium Voltage Circuit Breakers With Integral

GB/T / IEC :2006

Arc protection relay. Features Three-phase overcurrent function. Application

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

IEC unites low-and medium-voltage

INFRARED WINDOWS APPLIED IN SWITCHGEAR ASSEMBLIES: TAKING ANOTHER LOOK

EC Series. Safety Guide

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

Operating Instructions

Converter SINAMICS G150. Type 6SL37102G

VI - Safety techniques

Transcription:

MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator safety legislation for medium-voltage switchgear All energy sources are potentially dangerous but the required safety level can be ensured by taking the appropriate precautions and using devices that the laws and standards impose or that technical development provides. The ABB product manual provides precious guidelines and rules about how to use the product safely. It is essential to comply with these rules, but they cannot substitute careful assessment of the specific risks in the site or the safety plan required by the regulations and local laws.

MEDIUM VOLTAGE PRODUCTS 3 IEC 62271-200 and 50110-1 The product Standard for Medium Voltage switchgear is IEC 62271-200, High voltage switchgear and controlgear. Part 200: Metal-enclosed factory-built assemblies for voltage values from 1 to 52 kv. This standard is used in conjunction with IEC 62271-1, High voltage switchgear and controlgear. Part 1: Common specifications. The previously mentioned assemblies can include fixed and removable components housed in compartments that can also be filled with fluid (liquid or solid) to provide insulation. The standard defines quite a lot of switchgear and controlgear with metal enclosures, which differ as to the effects on continuity of service in the grid during maintenance work and the need for and convenience of the maintenance work itself. IEC 50110-1, which concerns Works on electrical installations, is another important standard which defines the roles and responsibilities that must be assigned to personnel who work on electrical installations. Internal arc From the point of view of safety and the protection of individuals in general, the most important issue is undoubtedly the internal arc. As mentioned in chapter 11 of IEC 62271-200, it is extremely important to underscore that the correct performance of Medium Voltage switchgear in the event of an internal arc does not merely depend on how the actual switchgear has been designed, but also on the installation conditions and operating procedures. None of the situations described depends on the manufacturer and must be carefully analysed by the manager of the installation, of which the switchgear is only a part. Even though the IEC standards still accept switchgear that is not internal arc resistant, in situations where the risk is considered negligible, ABB proposes UniSec medium-voltage switchgear solely in the internal arc resistant version since the safety of individuals is the prime concern. UniSec switchgear has been designed to minimize the risk of an internal arc occurring and particular attention has been paid to operator safety in internal arc situations. The switchgear units feature extremely high mechanical strength since they are able to withstand the pressure and thermal effects caused by high internal arc currents. UniSec switchgear has been subjected to the internal arc withstand test as specified by IEC 62271-200, Annex AA. UniSec switchgear offers various solutions for different requirements as to accessibility and for exhausting the hot gas after an internal arc. As mentioned above, choosing the correct solution from among those available is the task of the person responsible for the installation. To ensure that a correct and informed choice can be made, ABB describes all the solutions in detail in the UniSec Catalog (doc. 1VFM2000003) and in the UniSec Technical Guide (doc. 1VCP000587). A brief outline is given in the following pages. Internal arc withstand test structure for ABB UniSec switchgear

4 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR IAC solutions for UniSec Medium-Voltage switchgear IAC AF 16 ka 1s Basic proposal (1) This version only protects the operator against the effects of an internal arc if he is in front of the switchgear. The installation manager must implement procedures that prevent access to the other sides of the switchgear when in service. Protection at the Front (F) is guaranteed for 1 second up to 16 ka. The switchgear can be positioned against a wall or in the middle of the room. The gases produced by the arc are exhausted into the switchgear cabin. IAC AFL 12.5 ka 1s This solution protects the operator against the effects of an internal arc both when he is in front or at the sides of the switchgear, while protection at the rear is not provided. The installation manager must implement procedures that prevent access to the rear of the switchgear when in service. Protection at the Front (F) and Laterally (L) is guaranteed for 1 second up to 12.5 ka. Switchgear completely against a wall (2) The switchgear must be positioned right against a wall of the cabin. Closing plates at the top and sides of the switchgear convey the incandescent gas towards the rear and into a specially created compartment. Filters installed at the rear of each individual unit (2) The switchgear can be positioned against a wall or in the middle of the room. The gases produced by the arc are exhausted into the switchgear cabin after having been conveyed into the filter at the rear of each panel which cools them and reduces their pressure. 01 02

MEDIUM VOLTAGE PRODUCTS 5 IAC AFLR 21/25 ka 1s This solution protects the operator against the effects of an internal arc in whichever position he may be. Protection at the Front (F), Laterally (L) and Rear (R) is guaranteed for 1 second up to 21 ka (25 ka in some configurations). Filters installed at the rear of each individual unit (3) The switchgear can be positioned against a wall or in the middle of the room. The gases produced by the arc are exhausted into the switchgear cabin after having been conveyed into the filter at the rear of each panel which cools them and reduces their pressure. Gas exhausted downwards (3) The switchgear can be positioned against a wall or in the middle of the room. The gas produced by the arc is exhausted into the shaft through a duct installed at the rear of each panel. Gas exhaust duct (4) The switchgear can be positioned against a wall or in the middle of the room. The gases produced by the arc are exhausted outside the switchgear cabin through a dedicated duct between the switchgear itself and the wall. 03 04

6 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Accessibility Another important issue to bear in mind is how the mediumvoltage compartments can be accessed during normal operation, for maintenance work or any other reason. Product standard IEC 62271-200 also gives clear indications about this in Chapters 5 and 11 by defining the accessible compartments and giving details about the interlocks. The standard defines three methods for controlling the way an accessible compartment is opened: The first involves the use of interlocks for ensuring that all live parts inside the switchgear are dead and earthed before the compartment is opened. The second is based on the user s procedure and on a locking device to ensure safety. In this case, the compartment is equipped with padlocks, keys, locking magnets or some other equivalent device. The third method does not provide for any integrated devices to ensure electrical safety prior to opening, but tools are required to open the compartments; even commonly used objects, like screwdrivers or pliers, are considered tools. The first two types of compartment are available to operators. If a compartment requires tools for opening (the third type), this is normally a clear indication that the user must adopt other controls to guarantee safety. The procedures to be complied with in the installation and the roles and responsibilities of the various different individuals involved, as described in 50110-1, must be defined prior to any other activity, made available and known. All interlocks between the different positions of the apparatus and doors required to guarantee safety are mandatory in UniSec switchgear. As an option, it also provides a wide variety of keys, padlocks and locking magnets for the purpose of creating specific procedures for each installation. As mentioned above, choosing the correct solution from those available is the responsibility of the installation manager, since he is familiar with the entire installation of which the switchgear is only a part. An example is access to compartments declared accessible only with tools, such as a direct incoming feeder in duct, cable, or busbar. In this case, the standard does not envisage a disconnector and, as required by standard IEC 50110-1, the installation designer and user should provide for an adequate procedure when maintenance or other work is required. This procedure could also involve earthing at the other end of the cable. When the offer is being made, it is always advisable to coordinate with the installation designer to ensure that all needs to access the installation are addressed, not just access to the switchgear. Keys allowing a procedure to be created for earthing earthing-switches (for busbars, the line, incoming or outgoing feeders) are another example. The ability to earth a disconnector or to access a compartment in safe conditions does not only depend on the state of the panel and/or switchgear but also on the state of the installation. The safe state of any apparatus connected, e.g. the power transformers or the circuit-breaker on the load side of an incoming feeder, must also be ensured. Keys are the best things to use for this. To ensure the a correct and informed choice is made, ABB describes all the solutions in detail in the UniSec catalog (doc. 1VFM200003) and in the UniSec Technical Guide (doc. 1VCP000587). A brief outline is given in the following pages.

MEDIUM VOLTAGE PRODUCTS 7 Solutions for UniSec medium-voltage switchgear access Mandatory Interlocks Allowing the user to access a compartment during normal operation is a responsibility which, in the case of interlocking devices, lies with manufacturers of switchgear and controlgear and with the user, who receives product manuals (1VFM200004 and 1VFM200005) containing instructions about how to use the products correctly. On the other hand, the purpose is to ensure high level safety for operators who must perform tasks during the normal operation of the installation, by preventing them from performing incorrect operations. These devices must also be sufficiently sturdy to withstand attempted incorrect operations without damage. These interlocks are mandatory and always present in UniSec medium-voltage switchgear. To ensure that a compartment is always accessed in complete safety, the most important interlock is the one between the earthing position of the earthing switch and the door. Another important interlock is provided by shutters on the operating seats of the disconnector to prevent the operating lever from being inserted when this is not allowed. Optional Interlocks All interlocks designed to implement an accessibility procedure are considered optional. This, therefore, is the case of keys, padlocks and locking magnets use of which is not mandatory but linked to the specific requirements of the installation. For instance, to prevent an operation that is correct in principle (e.g. removal of an earthing connection for successive putting into service) but not permitted at that particular time, since there are maintenance technicians at work. In this case, the key provides enhanced safety when the procedure is implemented. The installation manager evidently plays a fundamental role in all this by indicating that keys or other systems are required when the installation is designed. It is always advisable to coordinate with the installation designer when the offer is being made to ensure that all needs to access the installation have been addressed. In addition, the installation manager must make sure that the users are aware that one or more procedures have been implemented, and that they have been adequately trained according to their levels of responsibility.

8 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Additional protection measures In addition to the switchgear structure being guaranteed by having passed the internal arc resistance test, standard IEC 6227-200 chapter 8 establishes that other active measures can be adopted to provide the highest possible level of protection for individuals if an internal arc occurs. These measures are directed towards limiting the external and internal consequences of such an event thanks to ultra-fast fault interruption times obtained by devices sensitive to light, pressure or heat. Alternatively, devices are available that reduce the risk for the operator by enabling the operations to be carried out in the remote mode instead of from in front of the apparatus. ABB can provide advanced technological solutions that also address this aspect of the standard and that have been implemented in UniSec switchgear. It is only right to remember that besides increasing operator safety, reducing the duration of the internal arc also reduces the damage caused by the event itself to a considerable degree. Time is a critical parameter with regard to reducing the effects of the arc, since the energy issued increases exponentially as time goes by. The longest part of fault extinguishing time is due to the break time of the circuitbreaker, while detector systems act in less than 15 ms. This means that the overall response can take less than 100 ms, so long as the circuit-breaker opens instantly and is sufficiently fast. Trip times of less than 100 ms considerably reduce both the risks for individuals and damage to the equipment, considering that UniSec medium-voltage switchgear is tested for 1 sec. duration. ABB systems for arc detection by light available in UniSec switchgear ABB can supply systems with optical fiber sensors able to detect the light generated by an internal arc. These systems consist of sensors and fiber installed in the various medium-voltage compartments, which are connected to the control units housed in the low voltage compartment. Regarding safety against false trips, the system only detects the lower part of the spectrum, including the ultraviolet part. Secondly, it is also connected to current sensors and can therefore combine both data items. Fault rating [ka2s] 300 Melting of structure components 200 Melting of cables Melting of copper 100 200 Fault duration [ms]

MEDIUM VOLTAGE PRODUCTS 9 TVOC-2 or REA These are two ABB arc detecting systems based on the principle described above whereby the light produced by the electric arc is detected. The typical trip time is 2/2.5 ms, to which the circuit-breaker break time should be added. The total break time is less than 100 ms. Protection with IED Certain IED (Intelligent Electronic Devices) such as REF615, RET615, REM615 and REF610, can use light sensors and create rapid, selective internal arc protection. The advantage of this solution is that no additional devices are required other than the protection and measuring relay. The typical trip time is 12 ms, to which the circuit-breaker break time should be added. The total break time is less than 100 ms.

10 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Remote operations The standard generically indicates remote operation rather than operation in front of the switchgear. This means that there is a certain distance between the operator and a potential internal arc, allowing the various operations to be performed in safer conditions. To achieve this further safety parameter, the apparatus must be motor-operated, a feature with which all the components available in UniSec switchgear can be equipped. Withdrawable vacuum circuit-breakers can be equipped with remote motoroperated loading of the springs for opening and closing operations as well as motor-operated trucks so as to perform the racking-in operation in the remote mode. The earthing switch is also available in the motor-operated version. GSec switch-disconnectors are also available with motor-operators in both the line and earth positions for complete remote control. Besides enhanced safety for the operator, who no longer has to work in front of the switchgear, operating procedures performed in the remote mode by a supervisor can also be added.

MEDIUM VOLTAGE PRODUCTS 11 Maintenance Switchgear and controlgear safety must be maintained over time. The installation manager is responsible for implementing use and maintenance procedures able to ensure that the safety level remains constant. Instructions for correctly servicing UniSec switchgear and its main components are given in the dedicated manuals (1VFM200004 e 1VFM200005), but it is of fundamental importance to know the real condition of the installation since it is based on this key information that the priorities able to mitigate risks and avoid effectively hazardous situations can be defined. This, obviously, in conjunction with the procedures and in compliance with the laws in force, as fully described above. Maintenance based on continous monitoring of the installation is certainly the most advanced. ABB proposes MySiteCare, which is available for UniSec switchgear. MySiteCare is a monitoring and diagnostic device that acquires the typical data of the circuit-breakers and processes them into diagnostic data for the purpose of determining the operating conditions and allowing maintenance to be planned. The data collected by MySiteCare are mechanical (such as time and number of operations) and environmental (such as temperature). Using these data, the device processes predictive diagnostic algorithms that provide information about the conditions of the circuit-breaker.

For more information please contact: Your sales contact: www.abb.com/contacts More product information: www.abb.com/productguide More service information: www.abb.com/service Copyright 2017 ABB. All rights reserved. The data and illustrations are not binding. We reserve the right to make changes in the course of technical development of the product. 1VCP000657 Rev. A, en Brochure UniSec Safety Operator 2017.10 (mt)