BNI IOL K006. IO Link Sensorhub digital User s Guide

Similar documents
BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL-104-S01-Z012-C02

BNI IOL Z012. User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL Z036 BNI IOL Z036

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL K023 BNI IOL K023. User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI USB A501. USB IO-Link Master User's Guide. english

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI IOL A027 BNI IOL A027

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

BNI USB A501. User s Guide

BIS L x-07-S4

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide

BNI IOL Z012. User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI EIP E002. EtherNet/IP IP69 modules User's Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual. 1

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BIS L x-07-S4

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide

BNI PNT Z015 BNI006C. IP67 Module User s Guide

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001

GFK-2415A March Type of sensor connection

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

BTL6-V11V-M -A1-S115 User's Guide

SCHMIDT Sensor interface PROFIBUS Instructions for use

BTL6-V1 _ E-M -A1-S115 User's Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

BIS M _ -07-S4 BIS M _ -07-S4

BIS L , BIS Z-EL-...

BNI CCL Z001. CC-Link IO-Link Master User s Guide

VersaMax IP I/O Module

VersaMax IP Input Module

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BTL6-A_10-M -A1-S115. Data Sheet. english

BIS M x-ST4 EtherNet/IP

BIS M xx-ST4 PROFINET

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

BIS S-6027 Ethernet with TCP/IP-Protocol

2-Axis Counter BDD 622

Manual Electronic Identification Systems BIS Processor BIS C-6_1 C6_1-023_9912-e.p65 Deutsch bitte wenden!

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

User's Manual. english

BTL5-A/C/E1_-M- -SF-F User's Guide

Operating instructions Memory plug E /02 11/2011

BIS V-6102 Profibus. Technical Description, User's Guide. English 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

AXL E IOL AO1 U M12 R

Manual LioN-P - IO-Link Device - I/O Hub

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide

Single-Axis Counter BDD 611

BVS SC-_1280Z _0 SMARTCAMERA Fieldbus

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide

Operating instructions AC010S Compact AS-i E-STOP safety module

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05

BIS V-6108 PROFINET. Technical Description, User s Guide. english

Manual Electronic Identification Systems BIS Processor BIS L-60_0 RS232 L-60_0-RS232_829572_0311_e.p65 Deutsch bitte wenden!

BIS V-6102 PROFIBUS Technical Reference, Operating Manual

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

SSI-1016H Specifications and Operation Manual

Handheld Programmer mer BIS

Transcription:

BNI IOL-104-000-K006 BNI IOL-102-000-K006 IO Link Sensorhub digital User s Guide

Content 1 Notes to the User 2 1.1. About this guide 2 1.2. Structure 2 1.3. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.4. Symbols 2 1.5. Abbreviations 2 2 Safety 3 2.1. Intended use 3 2.2. General safety notes 3 2.3. Meaning of the warnings 3 3 Getting Started 4 3.1. Connection overview 4 3.2. Mechanical connection 6 3.3. Electrical connection 6 3.4. IO-Link interface 6 3.5. Sensor interface 6 3.6. Communication parameters 7 3.7. Process data 7 data 7 Output data 7 3.8. Parameter data / On-request data 7 Identification data 7 Paramter 8 3.9. Errors 8 3.10. Events 9 4 Technical Data 10 4.1. Dimensions 10 4.2. Indicators / LEDs 11 Modul e Status 11 Digital s 11 5 Appendix 12 5.1. Type designation code 12 5.2. Order information 12 www.balluff.com 1

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102-1 Notes to the User 1.1. About this guide This guide describes the Balluff IO-Link sensor hub module. Connection to the host interface master is made through the IO-Link protocol. Functionally this compact, cost-effective module is comparable with a passive splitter box: It takes conventional sensor signals and passes them over the IO-Link interface. 1.2. Structure In this guide the sections build on one another. Section 2 : Basic safety information. Section 3 : The main steps for installing the device. Section 4: IO-Link, parameter and process data for the device. Section 5: Technical data for the device. 1.3. Typographical conventions Enumerations Actions Syntax Cross references The following typographical conventions are used in this Guide. Enumerations are shown in list form with bullet points. Entry 1, Entry 2. Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1. Action result. Action instruction 2. Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00 hex ). Cross-references indicate where additional information on the topic can be found (see Section 5 - "Technical Data ). 1.4. Symbols Note! This symbol indicates a security notice which most be observed Hinweis, Tipp This symbol indicates general notes. 1.5. Abbreviations BCD BNI DPP EMC I-Port DI FE IOL LSB MSB SPDU Binary coded switch Balluff Network Interface Direct Parameter Page Electromagnetic Compatibility Digital -Port Digital In Function ground IO-Link Least Significant Bit Most Significant Bit Service Protocol Data Unit www.balluff.com 2

2 Safety 2.1. Intended use The BNI IOL- is a decentralized sensor input module which is connected to a host IO-Link master over an IO-Link interface. 2.2. General safety notes Installation and startup Installation and startup are to be performed only by trained specialists. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer's guarantee and warranty. The device is an equipment in accordance with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see Section 5 Technical Data ). Only approved cables may be used. Operation and testing The operator is responsible for observing local prevailing safety regulations. When defects and non-clearable faults in the device occur, take it out of service and secure against unauthorized use. Approved use is ensured only when the housing is fully installed. 2.3. Meaning of the warnings Note! The pictogram used with the word "Caution" warns of a possible hazardous situation affecting the health of persons or equipment damage. Ignoring these warnings can result in injury or equipment damage. Always observe the described measures for preventing this danger. www.balluff.com 3

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102-3 Getting Started 3.1. Connection overview Abbildung 3-1: Anschlussübersicht BNI IOL-104-000-K006 1 Mounting hole 2 IO-Link interface 3 Status-LED: (Pin 2) 4 Standard--Port 1 5 Status-LED: (Pin 4) 6 Standard--Port 3 7 Standard- -Port 5 8 Standard- -Port 7 9 Status LED Power Supply 10 Standard -Port 6 11 Standard -Port 4 12 Standard -Port 2 13 Standard -Port 0 14 Label 15 Status-LED COM www.balluff.com 4

1 IO-Link Interface Abbildung 3-2: Anschlussübersicht BNI IOL-102-000-K006 1 Mounting Hole 2 IO-Link interface 3 Standard--Port 1 4 Status-LED: (Pin 4) 5 Standard- -Port 3 6 Standard- -Port 5 7 Standard- -Port 7 8 Status LED Power Supply 9 Standard -Port 6 10 Standard -Port 4 11 Standard -Port 2 12 Standard -Port 0 13 Label 14 Status-LED COM www.balluff.com 5

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102-1 IO-Link Interface 3.2. Mechanical connection 3.3. Electrical connection The BNI IOL modules are attached using 3 M4 screws (Item 1, Fig. 3-1/3-2). The Sensor Hub modules require no separate supply voltage connection. Power is provided through the IO-Link interface by the host IO-Link Master. 3.4. IO-Link interface The IO-Link connection is made using an M12 connector (A-coded, male). IO-Link (M12, A-coded, male) Pin Function 1 Supply voltage, +24 V, max. 1.6 A 2-3 GND, reference potential 4 C/Q, IO-Link data transmission channel 5 FE, function ground Connect protection ground to FE terminal, if present. Connect the incoming IO-Link line to the Sensor Hub. Note! A standard sensor cable is used for connecting to the host IO-Link Master. 3.5. Sensor interface Module-specific connection possibilities: Sensor-Hub Digital -Ports BNI IOL-104-000-K006 16 BNI IOL-102-000-K006 8 Standard input port (M12, A-coded, female) Pin Function 1 +24 V, max. 100 ma 2 (only BNI IOL-104 ) 3 0 V, GND 4 5 - Note! For the digital sensor inputs follow the input guideline per EN 61131-2, Type 2. Note! Unused I/O port sockets must be fitted with cover caps to ensure IP67 protection rating. www.balluff.com 6

1 IO-Link Interface 3.6. Communication parameters Baud rate COM2 (38,4 kbaud) Frame type 2.2 Minimum cycle time 3 ms Process data cycle 3 ms at minimum cycle time 3.7. Process data Following Process data is transmitted between IO Link Master and IO Link Device: data Output data Data which is sent from Device to Master. Data which is sent from Master to Device. data Process data length 2 bytes: Byte 0 Byte1 (only BNI IOL-104- ) 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin4 Port 3 Pin4 Port 2 Pin4 Port 1 Pin4 Port 0 Pin4 Port 7.Pin 2 Port 6.Pin 2 Port 5.Pin 2 Port 4.Pin 2 Port 3 Pin2 Port 2 Pin2 Port 1 Pin2 Port 0 Pin2 Output data There is no output data at BNI IOL-102- and BNI IOL-104-3.8. Parameter data / On-request data Identification Data DPP SPDU Index Index Subindex 07hex 08hex 09hex 0Ahex 0Bhex Parameter Vendor ID (0x0378) Device ID Data width 2 Byte 3 Byte 10hex 0 Vendor Name 8 Byte 11hex 0 Vendor text 16 Byte 12hex Product 21 Byte 0 Name 13hex 0 Product ID 7 Byte 14hex 0 Product text 27 Byte 16hex Hardware Revision 3 Byte 17hex Firmware 3 Byte 0 Revision Value range Read only Parameter Data 10hex 11hex 40hex 0 1-16 Invertierung 2 Byte 0hex FFFFhex Identification data Type Device ID BNI IOL-104-050101hex BNI IOL-102-050102hex www.balluff.com 7

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102-1 IO-Link Interface Paramter of the input signal Byte 0 Byte1 (only BNI IOL-104- ) 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin 4 Port 3 Pin 4 Port 2 Pin 4 Port 1 Pin 4 Port 0 Pin 4 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 Port 3 Pin 2 Port 2 Pin 2 Port 1 Pin 2 Port 0 Pin 2 3.9. Errors Error Code 11hex Additional Code Index not available Device application error: 80hex 12hex 30hex SubIndex not available Value out of range www.balluff.com 8

1 IO-Link Interface 3.10. Events Class/Qualifier Mode Type Instance Parameter Data appears Error AL Device Hardware supply Code (high + low) Supply low voltage U2 = supply + 24V C0hex 30hex 03hex 5000hex 0100hex 0010hex 0002hex F3hex disappears Error AL Device Hardware supply 5112hex Supply low voltage U2 = supply + 24V 80hex 30hex 03hex 5000hex 0100hex 0010hex 0002hex B3hex appears Error AL Device Hardware supply 5112hex supply periphery C0hex 30hex 03hex 5000hex 0100hex 0060hex F3hex disappears Error AL Device Hardware supply 5160hex supply periphery 80hex 30hex 03hex 5000hex 0100hex 0060hex B3hex 5160hex www.balluff.com 9

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102-4 Technical Data 4.1. Dimensions Abbildung 5-1: Abmessungen in mm 1.1 Mechanical data Housing material Plastic, transparent IO-Link Port M12, A-coded, male 1.2 Elektrical data I ports Enclosure rating Weight Dimensions (L W H, excluding connector) M12, A-coded, female (8x) IP67 (only when plugged-in and threaded-in) 90 g 115 50 30.8 mm Operating voltage 18... 30.2 V DC, per EN 61131-2 Ripple < 1 % Current draw without load 40 ma 1.3 Operating conditions Operating temperature -5 C +55 C Storage temperature -25 C +70 C EMC EN 61000-4-2/3/4/5/6 Severity level 4A/3A/4B/2A/3A Vibration/shock EN 60068 Part 2-6/27 www.balluff.com 10

1 IO-Link Interface 4.2. Indicators / LEDs Abb. 5-2: LED-indicators COM and I-Ports Modul e Status LED 4, IO-Link-Kommunikation Signal Function Green Green, negative pulsed Rot Aus No communikation Communikation OK Communication line overload Module unpowered LED 3, Modulversorgung Signal Green Green rapidly flashing Green slowly flashing Aus Function Supply voltage OK Supply voltage < 18 V Short circuit on input port Module unpowered Digital s LEDs are associated with the digital ports which indicate the operating states: LED 1 pin 2 (only BNI IOL 104) LED 2 - pin 4 Signal Function Gelb signal = 1 Aus signal = 0 www.balluff.com 11

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102-5 Appendix 5.1. Type designation code BNI IOL-10_-000-K006 Balluff Network Interface IO-Link interface Functions 104 = 16 s 0,1A 102 = 8 s 0,1A Variants 000 = Standardvariante Mechanical configuration K006 = Plastic housing Connectors: - BUS and Power Supply: 1x M12x1, external thread - -Ports: 8x M12x1, internal thread 5.2. Order information Type Order code BNI IOL-104-000-K006 BNI 0006 BNI IOL-102-000-K006 BNI 0005 www.balluff.com 12

Notes www.balluff.com 13

IO-Link Sensor-Hub BNI IOL-104- / BNI IOL-102- Notizen www.balluff.com 14

www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Tel. +49 7158 173-0 Fax +49 www.balluff.com 7158 5010 balluff@balluff.de Nr. 863422 E Edition 1011 Subject to modification