CA InterTest Batch 9.1 1 CA RS 1510 Service List Description Type 9.1 RO81892 JCL CONVERSION ERRORS/ABENDS WHEN JCL IS IN VB FILE PTF RO82385 S0C4 IN IN25COB2 WITH COBOL 5 PTF RO82480 INCORRECT PL/I MARGINI PROCESSING PTF RO83024 USER RECEIVES IGYOS4046-I USING COB2INT PTF RO83273 LONG PARM CONVERSION ERROR PTF RO83360 COBOL 5 POST PROCESSOR - INCORRECT STATEMENT DISPLACEMENT PTF RO83412 CAMRLPAQ FAILS TO DISPLAY DATE AND RELEASE PTF RO83738 RC=12 IN IN25COB2 SYM013 ERROR MESSAGE INCOMPLETE PTF The CA RS 1510 service count for this release is 8
CA InterTest Batch 2 CA RS 1510 Service List for CAMR910 FMID Service Description Type CAMR910 RO81892 JCL CONVERSION ERRORS/ABENDS WHEN JCL IS IN VB FILE PTF RO83024 USER RECEIVES IGYOS4046-I USING COB2INT PTF RO83273 LONG PARM CONVERSION ERROR PTF RO83412 CAMRLPAQ FAILS TO DISPLAY DATE AND RELEASE PTF The CA RS 1510 service count for this FMID is 4
CA InterTest Batch 3 CA RS 1510 Service List for CAVH910 FMID Service Description Type CAVH910 RO82385 S0C4 IN IN25COB2 WITH COBOL 5 PTF RO82480 INCORRECT PL/I MARGINI PROCESSING PTF RO83360 COBOL 5 POST PROCESSOR - INCORRECT STATEMENT DISPLACEMENT PTF RO83738 RC=12 IN IN25COB2 SYM013 ERROR MESSAGE INCOMPLETE PTF The CA RS 1510 service count for this FMID is 4
CA InterTest Batch 9.1 4 CA RS 1510 - PTF RO81892 9.1 RO81892 RO81892 M.C.S. ENTRIES = ++PTF (RO81892) JCL CONVERSION ERRORS/ABENDS WHEN JCL IS IN VB FILE InterTest Batch JCL conversion does not display VB JCL files correctly, file IO abends/errors for the input JCL file when the user does not supply a PROCLIB and JCL is in a VB file. JCL conversion errors, abends and/or misaligned JCL. JCL from VB libraries cannot be converted. Move JCL to a FB LRECL 80 dataset. CA-INTERTEST/BATCH-MVS Release 8.5 CA-INTERTEST/BATCH-MVS Release 9.1 INTBAT 972 Copyright (C) 2015 CA. All rights reserved. R00012-EJ6091-SP0 DESC(JCL CONVERSION ERRORS/ABENDS WHEN JCL IS IN VB FILE). FMID (CAMR910) SUP ( TR81892 )
CA InterTest Batch 9.1 5 CA RS 1510 - PTF RO82385 9.1 RO82385 RO82385 M.C.S. ENTRIES = ++PTF (RO82385) S0C4 IN IN25COB2 WITH COBOL 5 An S0C4 can occur while adding a COBOL 5 listing to the PROTSYM file. This may be related to the length of the listing itself or its static and automatic map. It may also depend on the current storage allocation in the address space. S0C4 abend in IN25COB2 at offset 535E, 5676 or a similar one, depending on the product release and maintenance applied. Medium. Some COBOL 5 symbolics cannot be added to the PROTSYM file. None. TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 8.5 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.0 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.1 TFMSYM 362 Copyright (C) 2015 CA. All rights reserved. R00019-AVH091-SP1 DESC(S0C4 IN IN25COB2 WITH COBOL 5). FMID (CAVH910) PRE ( RO80903 RO82152 ) SUP ( TR78260 TR79576 TR80361 TR82385 )
CA InterTest Batch 9.1 6 CA RS 1510 - PTF RO82480 9.1 RO82480 RO82480 M.C.S. ENTRIES = ++PTF (RO82480) INCORRECT PL/I MARGINI PROCESSING IN25SYMP PL/I symbolic post processor incorrectly processes the trailing character specified in the MARGINI compiler option. As a result, if parameters of some PL/I procedure spread across multiple lines, they are not recognized correctly. Error message SYMP508E followed by SYMP103W. Step ends with RC=8. For example: SYMP508E SEARCH FAILED FOR: COMMAREA_PTR SYMP103W PARAMETER DISPLACEMENT CANNOT BE DETERMINED. Medium. Symbolic information is not stored in the PROTSYM file. Recompile the PL/I source with compiler option NOMARGINI or MARGINI(' ') and run IN25SYMP again. TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 8.5 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.0 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.1 TFMSYM 363 Copyright (C) 2015 CA. All rights reserved. R00020-AVH091-SP1 DESC(INCORRECT PL/I MARGINI PROCESSING). FMID (CAVH910) SUP ( TR82480 )
CA InterTest Batch 9.1 7 CA RS 1510 - PTF RO83024 9.1 RO83024 RO83024 M.C.S. ENTRIES = ++PTF (RO83024) USER RECEIVES IGYOS4046-I USING COB2INT When using PROC COB2INT the user receives informational message IGYOS4046-I The "RESIDENT" option specification is no longer required. The resident runtime library support is always used. Informational message IGYOS4046-I is displayed. None, program compiles with RC of zero. None CA-INTERTEST/BATCH-MVS Release 9.1 INTBAT 984 Copyright (C) 2015 CA. All rights reserved. R00016-EJ6091-SP1 DESC(USER RECEIVES IGYOS4046-I USING COB2INT). FMID (CAMR910) SUP ( TR83024 ) ++HOLD (RO83024) SYSTEM FMID(CAMR910) REASON (ACTION ) DATE (15208) COMMENT ( +----------------------------------------------------------------------+ CA-INTERTEST/BATCH-MVS Release 9.1 SEQUENCE After Apply PURPOSE Member CAI.CAMRPROC(COB2INT) has changed. USERS AFFECTED Any user who references CAI.CAMRPROC(COB2INT) in their JCL. KNOWLEDGE REQUIRED Installation data set names, and PROC JCL ACCESS REQUIRED Update access to the CAI.CAMRPROC library ************************** * STEPS TO PERFORM * ************************** 1. Member CAI.CAMRPROC(COB2INT) has changed. It maybe necessary to update it with your sites data set names. ).
CA InterTest Batch 9.1 8 CA RS 1510 - PTF RO83273 9.1 RO83273 RO83273 M.C.S. ENTRIES = ++PTF (RO83273) LONG PARM CONVERSION ERROR CA InterTest Batch link JCL conversion utility incorrectly converts long PARM string. Invalid continuation is generated for PARMs enclosed in parenthesis resulting in an invalid JCL. JCL error when submitting converted JCL. Low. JCL needs to be manually edited after the conversion. CA-INTERTEST/BATCH-MVS Release 8.5 CA-INTERTEST/BATCH-MVS Release 9.1 INTBAT 981 Copyright (C) 2015 CA. All rights reserved. R00017-EJ6091-SP1 DESC(LONG PARM CONVERSION ERROR). FMID (CAMR910) SUP ( TR83273 )
CA InterTest Batch 9.1 9 CA RS 1510 - PTF RO83360 9.1 RO83360 RO83360 M.C.S. ENTRIES = ++PTF (RO83360) COBOL 5 POST PROCESSOR - INCORRECT STATEMENT DISPLACEMENT For COBOL 5 listings, when a verb is on the same line as a paragraph name the post processor saves an incorrect hex location for the statement. When using InterTest Batch, the initial intercept may display the current statement at the end of the program. Similar symptoms may occur in InterTest CICS as well. If verbs are on the same line as a paragraph name, InterTest may have an initial intercept at the wrong statement. Put verbs on separate line than paragraph names if compiling with COBOL 5, OR compile with an earlier COBOL release. TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 8.5 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.0 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.1 TFMSYM 365 Copyright (C) 2015 CA. All rights reserved. R00022-AVH091-SP1 DESC(COBOL 5 POST PROCESSOR - INCORRECT STATEMENT DISPLACEMENT). FMID (CAVH910) PRE ( RO80903 RO82152 ) SUP ( RO82385 TR78260 TR79576 TR80361 TR82385 TR83360 ) ++HOLD (RO83360) SYSTEM FMID(CAVH910) REASON (ACTION ) DATE (15218) COMMENT ( +----------------------------------------------------------------------+ TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.1 SEQUENCE After Apply PURPOSE Update a PROTSYM with a symbolic information for programs compiled with COBOL 5.1 or 5.2 USERS All users that maintain a PROTSYM AFFECTED KNOWLEDGE PROTSYM REQUIRED ACCESS Product libraries REQUIRED ************************** * STEPS TO PERFORM * ************************** Use IN25COB2 to load symbolic information for programs compiled with COBOL 5. If needed, more information on post processing can be found in "Chapter 3: Adding Symbolic Information" section of the Symbolic Guide. ).
CA InterTest Batch 9.1 10 CA RS 1510 - PTF RO83412 9.1 RO83412 RO83412 M.C.S. ENTRIES = ++PTF (RO83412) CAMRLPAQ FAILS TO DISPLAY DATE AND RELEASE The date and release levels are missing from the CAMRLPAQ's "INITIALIZATION SUMMARY REPORT" report. The release, date and time fields in the report are not correct. None. None. CA-INTERTEST/BATCH-MVS Release 9.1 INTBAT 987 Copyright (C) 2015 CA. All rights reserved. R00018-EJ6091-SP1 DESC(CAMRLPAQ FAILS TO DISPLAY DATE AND RELEASE). FMID (CAMR910) SUP ( TR83412 )
CA InterTest Batch 9.1 11 CA RS 1510 - PTF RO83738 9.1 RO83738 RO83738 M.C.S. ENTRIES = ++PTF (RO83738) RC=12 IN IN25COB2 SYM013 ERROR MESSAGE INCOMPLETE The SYM013 error message, which provides details about a VSAM error request, is not complete. Information about the VSAM macro type is missing. The SYM013 error message does not provide complete information about the error. Low. Use VSAM macro return and reason code to identify which macro type has resulted in an error. TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 8.5 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.0 TESTING TOOLS COMMON SYMBOLIC COMPONENT Release 9.1 TFMSYM 367 Copyright (C) 2015 CA. All rights reserved. R00023-AVH091-SP1 DESC(RC=12 IN IN25COB2 SYM013 ERROR MESSAGE INCOMPLETE). FMID (CAVH910) PRE ( RO80903 RO82152 RO83360 ) SUP ( RO82385 TR78260 TR79576 TR80361 TR81450 TR82385 TR83738 )