SE7600E Series Application Guide

Similar documents
SE7600E Series Application Guide

SEZ7000 Series. Wireless Commercial Zoning System

VZ7000 Series. BACnet Commercial Zoning System

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

SEZ7656R1045B / SEZ7656H1045B

SE7600E Series. Installation Guide for Commerical HVAC Applications CONTENTS

Viconics VT7682S Wireless Central Manager Application Guide

SER8300 Room Controller

Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet

SE7600F Series. Installation Guide for RTU with Modulating Heat CONTENTS

SE8300 Room Controller

Room Controllers. SC3000 Relay Pack

SmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

SER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide

THERMOSTATS & CONTROLLERS

SEZ7260X5x45B Installation Guide for BACnet MS/TP Zone Controller

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

SER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide

VT8600 Series Installation Guide. Rooftop Unit, Heat Pump and Indoor Air Quality Controller

VRP5045W1045W 24 VAC Powered ZigBee Repeater For Schneider-Electric Wireless Networks Applications

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

Smart Equipment Controls (SEC)

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications

VZ7656E1000W Zigbee Wireless RTU Terminal Equipment Controller with IAQ Control. Installation Guide

Andover ContinuumTM. b3850 Series Terminal Controllers

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

VZ7260X5X00W BACnet Zone Room Controller. Installation Guide. April 2017

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

Field selectable application type and room module series, via dip-switches on controller

March 13 th, 2012 / R2

Fast Route to Reliable Energy Savings ZIP Economizer

CONTENTS. Installation Guide. PIR Ready VT7200 Series 24 VAC Low Voltage Zoning Terminal Equipment Controller

HLS34 Modbus FCU/VAV Controllers installation instructions

System Controls Suggested Specification

Viconics BACnet Zoning System Application Guide VZ7260X5x00B and VZ7656X5000B Controllers

Installation Guide. VZ7656F1000B BACnet MS-TP RTU Terminal Equipment Controller with Modulating Heat. February 2017 /

BACnet. b3810 Series Local Controllers

VZ7656F1000W Zigbee Wireless RTU Terminal Equipment Controller with Modulating Heat. Installation Guide

BACnet. b3867 Terminal Controllers

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

TC-9102 Terminal Controller

VT8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

VZ7656B1000W Series Wireless RTU Thermostats For Commercial Zoning Systems

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM Infinet II

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

FX Input/Output (I/O) Modules XM07 and XM14

VZ7656B1000B Series BACnet RTU Thermostats For Commercial Zoning Systems

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Pre-programmed room controller with display and communication

Modular Room Control (MRC) Series Expansion Board

Underfloor Controllers

VT8300 Room Controller

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

ECON-ZIP-BASE. ZIP Economizer Base Module

QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Andover ContinuumTM Infinet II

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Features BACnet/IP over Wi-Fi, BACnet MS/TP, Delta LINKnet communication. EnOcean wireless for zone-level control, including sensors and outputs

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

ECONOMIZERS. Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH UNITS CAUTION WARNING

HARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide

Pre-programmed room controller with display and communication

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

The Bard BrightStat Room Controllers

Siemens BACnet Programmable TEC Constant Volume

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Room controller STRA-17

Communicating Thermostats. Add More Flexibility to Building Automation with. Communicating Thermostats

Andover ContinuumTM Infinet II

Siemens BACnet Programmable TEC Unit Vent Controller

clarity 3 Programmable Controller

STRA-17 Room controller. Installation and maintenance manual. Content

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

Application Guide. Fan Coil (FCU) Application Guide. VTR8000 Series Room Controllers. Control Performance Energy savings Better building management

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

BACnet MS/TP Interface User s Guide

Installation and Operation Instructions

Millennium Simplicity Elite Parameter Points and Quirks

Transcription:

Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview & Architecture 4 Models Available 4 Terminal Identification & Function 5 Typical Application 5 Main Output Wiring 5 Proportional Heat Control 6 Indoor Air Quality Control Standards 6 AI1 CO2 Input Operation 6 Using any 0-10VDC value for monitoring 6 Using a 0-10VDC CO2 sensor for control purposes 7 Indoor Air Quality & Sequence of Operations 8 Economizer Control Mode Only 8 Economizer Mode and Fresh Air Measurement Station 9 Economizer Mode and CO2 Level Control 10 Economizer Mode, CO2 Level Control and Fresh Air Measurement Station 11 Specifications 12

2 SE7600E SOLUTION OVERVIEW It is not uncommon for most of us to spend up to 90% of our time indoors. A large portion of that time is often dedicated to a working environment in a commercial building. Studies conducted by the Environmental Protection Agency (EPA) show that indoor air can contain levels of pollutants that are actually higher than levels typically found outdoors. In light of this, indoor air quality has become a major concern to businesses, building managers, tenants, and employees because of its direct impact on the comfort, well-being, and productivity of the building s occupants. Not all buildings have severe indoor air-quality issues, yet even well-run buildings can experience episodes of poor indoor air quality. The Schneider Electric SE7600E Indoor Air Quality Controller (IAQ), along with your preferred CO2 sensor, is a cost-effective solution that is capable of controlling economizer-free cooling and IAQ demand-based ventilation strategy while providing a fresh air measurement input right out of the box. The Schneider Electric IAQ Controller replaces the need for custom programmed DDC controllers and sensors in order to achieve the same results as in the past. When connected to a building automation system, the Schneider Electric IAQ Controller can monitor and verify the CO2 and fresh air levels, ensuring that air quality and energy efficiency is optimized. While primarily designed for use in small to midsized commercial building applications such as office buildings or schools, the Schneider Electric IAQ Controller can be installed in any other building type currently using a standard packaged rooftop or heat pump unit with a requirement for fresh air control. The Schneider Electric IAQ Controller provides a simple cost-effective solution. It offers advanced pre-programmed sequences of operations that can be installed without special software, tools or the presence of a network. This greatly reduces the installation cost and commissioning complexity while providing control functions immediately when powered on. Further energy saving benefits can be achieved with the use of a local onboard passive infrared motion sensor (PIR) that can automatically detect local activity allowing the IAQ to be controlled only when occupants are present thus saving on unnecessary energy costs. This functionality along with configurable night setback features makes it an economical yet highly effective control solution, which brings IAQ control and energy savings features in one simple yet powerful package that is Network Ready, BACnet, or ZigBee Wireless compatible..

3 SE7600E SERIES PRODUCT OVERVIEW The SE7600E series PI controller is specifically designed for RTU and Indoor Air Quality (IAQ) control. It is also designed for single stage, multi-stage, and or 0-10VDC analog heat control of heating or cooling equipment such as rooftop and self-contained units used in commercial applications and IAQ control via economizer control. The product features an intuitive, menu-driven, back-lit LCD display, which walks users through the configuring steps making the process extremely simple. Accurate temperature control is achieved due to the product s PI time proportional control algorithm, which virtually eliminates temperature offset, associated with traditional, differential-based controllers. IAQ control is achieved due to CO2 and airflow measurement and fresh air damper control using two analog inputs. SE7600E Series The controllers are also compatible with the new Schneider Electric PIR cover accessories. Controllers equipped with a PIR cover provide advanced active occupancy logic, which will automatically switch occupancy levels from Occupied to Unoccupied as required by local activity being present or not. This advanced occupancy functionality provides advantageous energy savings during occupied hours without sacrificing occupant comfort. All controllers can be ordered with or without a factory installed PIR cover (see ordering notes below). FEATURES AND BENEFITS Features Controls IAQ with a remote return duct or wall CO2 sensor. Controls and measure fresh air with a fresh air measurement station. Embedded free cooling economizer loop. One small compact thermostat-like controller. Network ready functionality built in. PIR sensor cover available as an accessory. Benefits Being able to control IAQ means healthier & more productive occupants. Meets new IAQ requirements and regulations for LEED type buildings. True energy savings with adjustable economizer control loop. Minimum fresh air can be measured and controlled with the fresh air measurement station. Simple to install cost effective package. Easy thermostat-like operation for the end user. Allows for future network functionality along with remote monitoring of all critical system data points for sustainability. Further energy savings is possible with the use of local PIR cover to automatically detect local occupancy. IAQ is maintained and controlled only when occupants are present to save energy costs.

4 SYSTEM OVERVIEW AND ARCHITECTURE The SE7600E series PI controller is specifically designed for RTU and Indoor Air Quality (IAQ) control. It is also designed for single stage, multi-stage, and or 0-10VDC analog heat control of heating or cooling equipment such as rooftop and self-contained units used in commercial applications and IAQ control via economizer output. The product features an intuitive, menu-driven, back-lit LCD display, which walks users through the configuring steps making the process extremely simple. Accurate temperature control is achieved due to the product s PI time proportional control algorithm, which virtually eliminates temperature offset, associated with traditional, differential-based controllers. IAQ control is achieved due to CO2 and airflow measurement and fresh air damper control using two analog inputs. The controllers are also compatible with the new Schneider Electric PIR cover accessories. Controllers equipped with a PIR cover provide advanced active occupancy logic, which will automatically switch occupancy levels from Occupied to Unoccupied as required by local activity being present or not. This advanced occupancy functionality provides advantageous energy savings during occupied hours without sacrificing occupant comfort. All controllers can be ordered with or without a factory installed PIR cover (see ordering notes below). They also feature a discharge air sensor input. Particularly, the SE7600E series features a 0-10VDC fresh air damper output that can be used to for free cooling (economizer function) and/or for CO2 level control. The following hardware is required for operation of the RTU controller, but not included: 24 VAC power supply. Typically taken directly from the RTU power supply (C & RC). A spring return 0-10VDC damper actuator. An outdoor air sensor. A supply air duct sensor. A return air duct sensor (optional) or Room. Proper wiring of all components as per the installation manual. Proper network wires pulled through all devices communication connections. A 0-10 Vdc Fresh air measurement station. A 0-10 Vdc 0-2000 PPM room or return duct CO2 sensor. Models Available Application Model (with schedule) Model (without schedule) Model SE7656E5x45(X) SE7606E5x45(X) Ordering Information Notes: - (X) model number represents available communication options: ( ) : Not communicating, network Ready (B) : BACnet MS/TP (W) : ZigBee Wireless (P) : ZigBeePro Wireless - Controllers can be ordered with a factory installed PIR cover. Please use (5545X) extension instead of the (5045X) only extension. Ex. SE7606B5545B. - Controllers ordered without a PIR cover can be retrofitted with a separate PIR accessory cover afterwards when required.

5 TERMINAL IDENTIFICATION & FUNCTION Terminal Use Terminal Identification Description 1 Cool 2 Y2 Output for cooling / compressor stage number 2. 2 Cool 1 Y1 Output for cooling / compressor stage number 1. 3 - Fan G Output for the fan. 4-24 V ~ Hot RC Power supply of thermostat, hot side (Delivered from the RTU). 5-0 V ~ Com C 6 Heat Switch Leg RH 7 Heat 1 W1 Output for heating stage number 1. 8 Heat 2 W2 Output for heating stage number 2. Power supply of thermostat, common side. Also used as reference for the analog signal(s). 24 VAC switched leg for the heating stages. If heating stages are part or RTU, install a jumper across RC & RH. If heating stages are part of separate equipment with a different power supply, feed external switched power leg through RH without installing a jumper across RC & RH. 9 Economizer Output EC 0-10 VDC analog fresh air damper / economizer output. 10 Analog Heat Output AO 0-10 VDC analog heating output. 11 RS RS Remote room or return air temperature sensor input. 12 MS MS Discharge air temperature sensor input 13 AI1 AI1 0-10 VDC analog input for CO2 transmitter 14 Scom Scom Reference input for AI, RS, OS and MS 15 OS OS Outside air temperature sensor input 16 AI2 AI2 0-10 VDC analog input for airflow transmitter TYPICAL APPLICATION Jumper Y2 Y1 G RC C RH W1 W2 EC AO RS MS AI1 Scom OS AI2 Cool Stage 2 Cool Stage 1 Fan Heat Stage 1 Heat Stage 2 0-10 VDC 24V Com 0-10 VDC 24V Com Remote Room or Return Air sensor Mixed Air 0-10 Vdc Input Outdoor 0-10 Vdc Input 24 VAC Thermostat internal contacts System wiring Transfo Main outputs wiring Wiring notes: Note 1: If the same power source is used for the heating stages, install jumper across RC & RH. Maximum current is 2.0 amps. Note 3: Electromechanical contacts are to be used with the digital inputs. Electronic triacs cannot be used as mean of switching for the input. The switched leg to the input for the input to activate is terminal C (common) Note 4: The transformer of the unit provides power to the Note 2: Economizer and all analog outputs and inputs use a half Terminal Equipment Controller and the additional loads that will be bridge rectifier. Reference of the control signal is the common of wired to the Terminal Equipment Controller. the power supply of the Terminal Equipment Controller. (Terminal C).

6 Proportional Heat Control The Schneider Electric SE7600E IAQ controller has the ability to maintain a minimum heating supply temperature by using an analog 0-10VDC proportional output instead of using the staging outputs which will cause the unit to cycle. Using a full proportional output to maintain the minimum heating supply temperature can increase cost savings and less wear and tear on HVAC equipment. Indoor Air Quality Control Standards The IAQ control is achieved by the SE7600E controller through CO2 level and minimum fresh air control. The building CO2 level has to respect the local building codes. The recommended outdoor air flow per the ASHRAE standard for office buildings (Air class 1) is as follows: Table from: ASHRAE Standard 62. AI1 CO2 Input Operation The SE7600E controller features a 0-10VDC input (AI1) that is used for monitoring using any 0-10VDC 0-2000 PPM sensor or to control the building CO2 level. Using any 0-10VDC value for monitoring If the AI1 input is used for monitoring purposes only (even if monitoring CO2 with a CO2 sensor), the AI1 parameter should be set to None (not CO2). The value of the AI1 input can then be monitored at the network level (BACnet front end) under: AI1 value BACnet object (in VDC) Locally at the controller, the value of AI1 can only be obtained by measuring the voltage between Scom and AI1 using a voltmeter. The value of AI1, if AI1 parameter is set to None, will not be displayed on the controller s screen at any time. Using a 0-10VDC CO2 sensor for control purposes If the AI1 input is used with a CO2 sensor for control purposes, the AI1 parameter should be then set to CO2. In this case, a CO2 value will be displayed at the end of the configuration parameters list showing the CO2 level measured by the sensor in ppm (parts per million). The value of the AI1 input will also be displayed at the network level under: Room CO2 Value BACnet object (in ppm) AI1 value BACnet object (in VDC) When AI1 parameter is configured to CO2, the CO2 control is enabled only in Occupied mode. The SE7600E will use these CO2 values to determine the building s CO2 Level for the IAQ control sequence.

7 INDOOR AIR QUALITY & SEQUENCE OF OPERATIONS The fresh air damper can be controlled through more than one sequence to achieve different control strategies such as free cooling (economizer mode), minimum fresh air control and CO2 level control. Here are the control sequences available: Note: For the sequences mentioned below, the following conditions must be met in order for the sequences to be performed as stated: Max Pos parameter value must be greater than Min Pos Parameter value. Max CO2 parameter value must be greater than Min CO2 Parameter value. Max FA parameter value must be greater than Min FA Parameter value. Economizer Control Mode Only Cooling Coil Fan Outside Air OA Control Board Heating Coil RA SA Supply Air BACnet open communication protocols ZigBee optional communication protocols If the fresh air damper is to be used only for free cooling purposes (economizer mode, without fresh air measurement station or CO2 control), only the Min Pos parameter and the free cooling sequence will be active. - The FA Range parameter should be set to 0 CFM. (Default Value = 0 CFM) - Set the Chngstpt parameter to desired value which free cooling is enabled. (Default Value = 55 F) If the outside air temperature is greater than the changeover setpoint, then normal mechanical cooling will be used. If the outside air temperature is less than or equal to the changeover setpoint, then free cooling will be enabled and mechanical cooling stages will be locked out.

8 Economizer Mode and Fresh Air Measurement Station Cooling Coil Fan Outside Air OA Control Board Heating Coil RA SA Supply Air BACnet open communication protocols ZigBee optional communication protocols If the fresh air damper is to be used for both free cooling and minimum fresh air volume control (economizer mode and fresh air measurement station, but without CO2 level control), only the Min FA parameter and the free cooling sequence will be active. - The FA Range parameter should be set to a value higher than 0 CFM (0 CFM disables the fresh air control). - Min FA (minimum fresh air) parameter should be set to the desired level. The FA Range parameter value should be set to the maximum capacity of the fresh air measurement station. Therefore the relationship between air volumes and input signals can be established. For example, if the fresh air station capacity is 10450 CFM, set FA Range to 10450. This will set the relationship of 0 VDC = 0 CFM and 10VDC = 10450 CFM.

9 Economizer Mode and CO 2 Level Control Fresh air measurement station Cooling Coil Fan Outside Air Heating Coil OA Control Board RA SA CO2 Supply Air BACnet open communication protocols ZigBee optional communication protocols If the fresh air damper is to be used for both free cooling and CO2 level control (economizer mode and CO2 level control, but without fresh air measurement station), only the Min Pos, Max Pos, Min CO2and Max CO2 parameters as well as the free cooling sequence will be active. - The FA Range parameter should be set to 0 CFM. - Set AI1 parameter to CO2 (0 VDC = 0ppm ; 10VDC = 2000ppm) - Min Pos, Max Pos, Min CO2 and Max CO2 parameters should be set according to the required setting. Current CO 2 level Max Pos Current Fresh Air Damper Position Min Pos Min CO 2 Max CO 2 Current CO Level The higher value between free cooling output and interpolation output between the above graphic will be the signal sent to the fresh air damper.

10 Economizer Mode, CO 2 Level Control and Fresh Air Measurement Station Fresh air measurement station Cooling Coil Fan Outside Air OA Control Board Heating Coil RA SA CO2 Supply Air BACnet open communication protocols ZigBee optional communication protocols If the fresh air damper is to be used for both free cooling and CO2 level control with a fresh air measurement station, only the Min FA, Max FA, Min CO2 and Max CO2 parameters as well as the free cooling sequence will be active. - The FA Range parameter should be set to something other than 0 CFM. - Use an air flow transmitter to read fresh air level with AI2 input ( 0-10 VDC input ) - Min FA, Max FA, Min CO2 and Max CO2 parameters should be set according to the required setting. Current CO 2 level Max FA Setpoint Current Min FA FA Setpoint Setpoint Min CO 2 Max CO 2 Current CO Level The higher value between free cooling output and interpolation output based on the above graphic will be the signal sent to the fresh air damper. If the occupancy is unoccupied, then the CO2 control output will be 0%.

11 SPECIFICATIONS Terminal Equipment Controller power requirements 19-30 VAC 50 or 60 Hz; 2 VA Class 2 RC to RH jumper 2.0 Amps 48VA max. Operating conditions 0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing Storage conditions -30 C to 50 C ( -22 F to 122 F ) 0% to 95% R.H. non-condensing Local 10 K NTC thermistor Resolution ± 0.1 C ( ± 0.2 F ) Temperature control accuracy Contact output rating ± 0.5 C ( ± 0.9 F ) @ 21 C ( 70 F ) typical calibrated Relay outputs: 30 VAC, 1 Amp. Maximum, 3 Amp. In-rush. Occ, Stand-By and Unocc cooling setpoint range 12.0 to 37.5 C ( 54 to 100 F ) Occ, Stand-By and Unocc heating setpoint range: 4.5 C to 32 C ( 40 F to 90 F ) Room and outdoor air temperature display range: -40 C to 50 C ( -40 F to 122 F ) Supply air temperature range: -40 C to 65 C ( -40 F to 150 F ) Air flow & CO2 level analog inputs Modulating heating and economizer analog outputs rating Analog outputs accuracy Wire gauge 0-10 VDC across AI's & SCom 0 to 10 VDC into 2KΩ resistance min ± 3% typical 18 gauge max. 22 gauge min. Approximate shipping weight 0.75 lb ( 0.34 kg ) Agency Approvals all models Agency Approvals all models Agency Approvals Wireless models UL: UL 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN XAPX (US) and XAPX7 (Canada) Industry Canada: ICES-003 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) CE : EMC Directive 2004/108/EC (Europe Union) C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand) Supplier Code Number N10696 FCC: Compliant to: Part 15, Subpart B, Class (US) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Please check with your local government for instruction on disposal of this product. When replacing an existing Terminal Equipment Controller, label the wires before removal of the Terminal Equipment Controller. Electronic controls are static sensitive devices. Discharge yourself properly before manipulating and installing the Terminal Equipment Controller. A short circuit or improper wiring may permanently damage the Terminal Equipment Controller or the equipment. All SE7000 series Terminal Equipment Controllers are designed for use as operating controls only and are not safety devices. These instruments have undergone rigorous tests and verification prior to shipping to ensure proper and reliable operation in the field. Whenever a control failure could lead to personal injury and or loss of property, it becomes the responsibility of the user or installer or electrical system designer to incorporate safety devices (such as relays, flow switch, thermal protections, etc ) and or an alarm system to protect the entire system against such catastrophic failures. Tampering with the devices or unintended application of the devices will result in a void of warranty. 2013 Schneider Electric. All rights reserved. All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9674 http://www.schneider-electric.com/buildings AG-SE7000-RTUIAQ-US.EN.4.2013.v1 July 2013