Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Similar documents
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

DCG Commercial. Submittal Data Form

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Installation Instructions

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Brasch Washdown Unit Heaters

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name:

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

DCG Series. Submittal Data Form. 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

Parts List, Wiring Diagrams

Precision Cooling. Precision Cooling Advantages

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

CONDENSING UNITS UASL- JEC

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintage A. TYA, TAA No Vintage. Last Manufactured: 1993

Precision Cooling Mission Critical Air Handling Units

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

DUCTED SPLIT SYSTEMS With Scroll compressors

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Avanti HP Series Centrifuges Preinstallation

U-Match Series DC Inverter Service Manual PRODUCT

Contents. Cabinet Components " Exploded View... 1 " Usage List U.S. Models... 2 " Usage List Canadian Models... 3 " Blank Page...

Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

McQuay. Commercial Unitary Rooftop Cooling Only or with Electric Heat. LCA Design 1. Last Manufactured: 2004

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

INSTALLATION INSTRUCTIONS

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

PanelView Plus/VersaView CE Terminals and Display Modules

YORK HVAC PRODUCT GUIDE

Preliminary Supplement Instructions

Ceiling Concealed Split System C Series

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Spring Test 5 due 4/26/2013

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

Semi-hermetic Air-cooled Condensing Units

Self-Contained Air Conditioning Systems

IN STAL LA TION IN STRUC TION

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Smartstart Control Module

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series

Specification and Design Catalog. Waterside Economizer

CI-tronic Soft start motor controller

SECTION SWITCHBOARDS

SSW06. Soft Starters.

Split System Cooling Product & Performance Data

ECON-ZIP-BASE. ZIP Economizer Base Module

Junos WebApp Secure 5.0 Hardware Guide

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL8B024 THRU 060

Product Data. 24ANB1 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

IPS INTELLIGENT PUMP STARTER

Product Data. Reliability

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Parts List, Charging Chart, Wiring Diagrams

FEATURES AND BENEFITS. Installation and operation. Controller

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

4-step Chiller and Heat Pump Controller

SECTION PANELBOARDS

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

J&M Fluidics, Inc. Company Product Overview

AIR COOLED MODULAR RECTIFIER

Company, Simplex Onsite, providing nationwide load bank rentals.

DESIGN & TECHNICAL MANUAL

S66 Series Electronic Fan Speed Control

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

Transcription:

THE WALL-MOUNT AIR CONDITIONER.0 EER, (HZ) Models JAA to J72AA Right-ide Control Panel Models JLA to J72LA Left-ide Control Panel. to Ton (7,000 to 7,000 Btuh) The olair Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Green Refrigerant R-A Engineered Features Aluminum Finned Copper s: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Air Conditioner Compressor: croll Compressors eliminate need for crankcase heater. tandard on all models, except -Ton. R-A Refrigerant: Designed with R-A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and EPA requirements. Phase Rotation Monitor: tandard on all 3-phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 00 hours of salt spray tests per ATM B7-03. Foil Faced Insulation: tandard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. Filter ervice Door: eparate service door provides easy access for filter change. Two Inch, MERV Pleated Air Filters: Are standard equipment. Factory or field installed. Condenser Fan and Motor hroud Assembly: lides out for easy access. Barometric Fresh Air Damper: tandard on all units. Allows up to 2% outside fresh air. Optional ventilation packages available. Optional Circuit Breakers: tandard on all electric heat versions of single (2/ volt) and three phase (2/ volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase ( volt) equipment. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. Freezestat: tandard on W72 models. Optional field installed CMC-2 can be used on all other models. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in offdelay timer adjustable from seconds to minutes. 2-minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. High & Low Pressure witches are Auto- Reset: tandard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Complies with efficiency requirements of AHRAE/IENA 0.-3. Certified to ANI/ARI tandard 30-03 for PVU (ingle Package Vertical Units). Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL /CA 22.2 No. 23-0, Fourth Edition. Commercial Product - Not intended for Residential application. Form No. - upersedes - Page of 2

Capacity and Efficiency Ratings Models JAA JLA J2AA J2LA JAA JLA Cooling Capacity BTUH 7,000 2,0,000 3,00,0,000,000 7,000 EER.00...00.00.00.00.00 J3AA J3LA Capacity is certified in accordance with ANI/ARI tandard 30-03. EER = Energy Efficiency Ratio and is certified in accordance with ANI/ARI tandard 30-03. All ratings based on fresh air intake being 0% closed (no outside air introduction). J2AA J2LA JAA JLA JAA JLA J72AA J72LA pecifications -/2 Ton through 3 Ton MODEL JAA-A JLA-A J2AA-A J2LA-A J2AA-B J2LA-B J2AA-C J2LA-C JAA-A JLA-A JAA-B JLA-B JAA-C JLA-C J3AA-A J3LA-A J3AA-B J3LA-B J3AA-C J3LA-C Electrical Rating Hz 2/ - 2/ - 2/ - 3-3 2/ - 2/ - 3-3 2/ - 2/ - 3-3 Operating Voltage Range 7-23 7-23 7-23 - 7-23 7-23 - 7-23 7-23 - Compressor--Circuit A Voltage 2/ 2/ 2/ 2/ 2/ 2/ 2/ Rated Load Amps.0/..2/..0/..3./2.0./7. 3. 3././.. Branch Circuit election Current.0 2..3..0.0.7 7. 3.2.0 Lock Rotor Amps / / / 2 77/77 7/7 3 2/2 / Compressor Type croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 Fan Motor--Amps.2.2.2 0... 0... 0. Fan--DIA/CFM " - 00 " - 00 " - 00 " - 00 " - 200 " - 200 " - 200 " - 20 " - 20 " - 20 Blower Motor & Evap. Blower Motor--HP-RPM-PD /-0-2 /-0- /-0- /-0- /3-0-2 /3-0-2 /3-0-2 /3-0-2 /3-0-2 /3-0-2 Blower Motor--Amps 0.... 2.0 2.0.0 2.0 2.0.0 CFM Cooling & E..P. w/filter (Rated- ) 0 -. 00 -. 00 -. 00 -. 00 -. 00 -. 00 -. 0 -. 0 -. 0 -. Filter izes (inches) TD. x2x x2x x2x x2x xx xx xx xx xx xx hipping Weight --LB. 3 3 3 3 3 3 3 +Barometric Fresh Air Damper-Lbs 3. 3. 3. 3..0.0.0.0.0.0 +Economizer-Lbs.0.0.0.0 7.0 7.0 7.0 7.0 7.0 7.0 pecifications 3-/2 Ton through Ton MODEL J2AA-A J2LA-A J2AA-B J2LA-B J2AA-C J2LA-C JAA-A JLA-A JAA-B JLA-B JAA-C JLA-C JAA-A JLA-A JAA-B JLA-B JAA-C JLA-C J72AA-A J72LA-A J72AA-B J72LA-B Electrical Rating Hz 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 J72AA-C J72LA-C Operating Voltage Range 7-23 7-23 - 7-23 7-23 - 7-23 7-23 - 7-23 7-23 - Compressor--Circuit A Voltage 2/ 2/ 2/ 2/ 2/ 2/ 2/ 2/ Rated Load Amps./../..2 7.3/../3.3. 2./23.2 3./. 7. 27.7/../.. Branch Circuit election Current. 3.. 2...3 23.2. 7. 3. 22.. Lock Rotor Amps / 3./3. / / / / / / 7 Compressor Type croll croll croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM-PD /3-2-2 /3-2-2 /3-2- /3-2-2 /3-2-2 /3-2- /3-2-2 /3-2-2 /3-2- /2-7- /2-7- 3/-7- Fan Motor--Amps 2. 2..3 2. 2..3 2. 2..3.0.0.7 Fan--DIA/CFM 2" - 0 2" - 0 2" - 0 2" - 00 2" - 00 2" - 00 2" - 2" - 2" - 2" - 000 2" - 000 2" - 000 Blower Motor & Evap. Blower Motor--HP-RPM-PD /3--2 /3--2 /3--2 /3--2 /3--2 /3--2 /2-70-2 /2-70-2 /2-70-2 3/--2 3/--2 3/--2 Blower Motor--Amps 2.3 2.3.2 2.3 2.3.2 3. 3. 2..3.3.7 CFM Cooling & E..P. 0 -.0 0 -.0 0 -.0 -. -. -. 00 -. 00 -. 00 -. 00 -.2 00 -.2 00 -.2 w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx xx xx xx xx xx xx xx xx hipping Weight --LB. 7 7 7 +Barometric Fresh Air Damper-Lbs............ +Economizer-Lbs............ Form No. - upersedes - Page 2 of 2

Ventilation ystem Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or field-installed at a later date. BAROMETRIC FREH AIR DAMPER - BFAD TANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 2% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. MI-37 Barometric Fresh Air Damper Economizer MI-377 ECONOMIZER WECO eries OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outside ventilation air, up to 0% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. tandard Features: Fully modulating Honeywell Hi-Torque Actuator 7" intake hood with filter imple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available Form No. - upersedes - Page 3 of 2

Electrical pecifications J**AA eries (Field Installed Elec. Heat Only) MODEL JAA-A00,A0Z A0 A J2AA-A00, A0Z A0 A0 A J2AA-B00, B0Z Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: Rated Volts & Phase 2/- 2/- Form No. - upersedes - Page of 2 No. Field Power Circuits B0 2/-3 J2AA-C00, C0Z -3 C0 JAA-A00, A0Z A0 2/- A A or 2 JAA-B00, B0Z B0 B0 B JAA-C00, C0Z C0 C0 C2 C J3AA-A00, A0Z A0 A A J3AA-B00, B0Z B0 B0 B J3AA-C00, C0Z C0 C0 C2 C J2AA-A00, A0Z A A A J2AA-B00, B0Z B0 B B J2AA-C00, C0Z C0 C JAA-A00, A0Z A A A JAA-B00, B0Z B0 B B JAA-C00, C0Z C0 C JAA-A00, A0Z A A A JAA-B00, B0Z B0 B B JAA-C00, C0Z C0 C J72AA-A00, A0Z A A A J72AA-B00, B0Z B0 B B J72AA-C00, C0Z C0 C 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 or 2 or 2 or 2 or 2 or 2 or 2 or 2 2 or 2 or 2 or 3 2 Minimum Circuit Ampacity 2 2 22 2 7 2 2 7 2 2 2 7 23 2 2 7 2 2 2 2 7 2 3 3 2 2 7 2 3 3 2 27 3 27 2 0 0 27 ingle Circuit Maximum External Fuse or Ckt. Brkr. 2 0 2 2 0 2 0 2 0 2 0 2 0 0 70 0 2 2 2 Field Power Wire ize 2 2 2 2 2 2 2 2 2 3 2 2 2 3 2 Ground Wire Multiple Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C 2 2 2 2 2 2 2 2 2 While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. 2 2 2 2 2 2 2 0 2 2 2 2 2 2 0 2

Electrical pecifications J**LA eries (Field Installed Elec. Heat Only) MODEL JLA-A00,A0Z A0 A J2LA-A00, A0Z A0 A J2LA-B00, B0Z Rated Volts & Phase 2/- 2/- No. Field Power Circuits B0 2/-3 J2LA-C00, C0Z -3 C0 JLA-A00, A0Z A0 2/- A A or 2 JLA-B00, B0Z B0 B JLA-C00, C0Z C0 C J3LA-A00, A0Z A A J3LA-B00, B0Z B0 B J3LA-C00, C0Z C0 C J2LA-A00, A0Z A A J2LA-B00, B0Z B0 B J2LA-C00, C0Z C0 C JLA-A00, A0Z A A JLA-B00, B0Z B0 B JLA-C00, C0Z C0 C JLA-A00, A0Z A A JLA-B00, B0Z B0 B JLA-C00, C0Z C0 C J72LA-A00, A0Z A A J72LA-B00, B0Z B0 B J72LA-C00, C0Z C0 C 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 or 2 or 2 or 2 or 2 or 2 or 2 Minimum Circuit Ampacity 2 22 2 7 7 2 2 23 7 2 2 2 7 2 3 3 2 2 7 2 3 3 27 3 27 2 0 0 27 ingle Circuit Maximum External Fuse or Ckt. Brkr. 2 0 0 0 0 0 0 0 70 0 2 2 Field Power Wire ize 2 2 2 2 2 2 2 3 2 2 3 Ground Wire Dual Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. 2 2 Form No. - upersedes - Page of 2

Indoor Blower Performance ( Hz) - CFM at Rated Voltage peed J J2 J J3 J2 J J J72 High Low ingle High Low High Low High Low High Low High Low High Low EP (Inch H) 0.0 00 7 7 7 0 00 3 0 0 00 70 00 0 7 700 2 0 22 2 0. 700 0 2 3 30 2 0 0 0 700 0 7 0 2 0.2 00 0 70 20 2 0 0 7 770 0 0 70 00 2 0.3 0 2 00 2 0 0 0 7 7 0 2 00 0 2 70 0. 7 7 7 7 7 2 0 00 7 2 0 7 0 37 3 00 700 2 0. 0 7 7 70 70 0 0 0 7 70 70 2 Above data is with " standard throwaway filter and " washable filter. For optional 2" pleated filter - reduce EP by. in. ee installation instructions for maximum EP information on various KW application. Factory Connected peed. Electric Heat Table - Refer to Electrical pecifications for Availability by Unit Model Nominal KW Kw At 20V () At V () At 0V (2) At V (2) -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh.0.0.7 3,2 3.00.,23.0.0. 7,0 3.7.0 2,7.0.0.,7. 2.,.0 7.2,7.2.,0.0.0.3 27,.00 2.,7.0.0 2.7,77.7.7 23,03.0.,77.2. 2,2.0.0.7 3, 7. 3. 2,.0.0 2. 3.,.2. 3.2 3,3.0.0, 3.0 7.3 7,0.0.0 3.3,3 3. 37.,07.0 2.7,3..,.0.0 3.3,2.00 72., () These electric heaters are available in 2/V units only. (2) These electric heaters are available in 0V units only. Form No. - upersedes - Page of 2

Heater Packages - Field Installed "A" eries Right-Hand Units Designed for adding Electric Heat to 0 KW Units Circuit Breaker tandard on 2/V Models Air Conditioner Models -A00 Models 2/- ETL U & Canada Listed Toggle Disconnect tandard on V Models -B00 Models 2/-3 -C00 Models -3 Heater Model # KW Heater Model # KW Heater Model # KW JAA EHWA02-B EHW02A-A0B EHWA02A-AB J2AA EHWA2A-A0B EHWA02-B EHW02A-A0B EHWA02A-AB EHWA2-B0B EHWH2B-C0 JAA EHWA03-B EHWA03-A0B EHWA03-AB EHWA03-AB EHWA03-B0B EHWA03-B0B EHWA37-BB EHWC03A-C0 EHWC03A-C0 EHWA03A-C2 EHWA03A-C 2 J3AA EHWA03-B EHWA03-A0B EHWA03-AB EHWA03-AB EHW3A-B0B EHWA03-B0B EHWA37-BB EHWC03A-C0 EHWC03A-C0 EHWA03A-C2 EHWA03A-C 2 J2AA JAA EHWTA- EHW-AB EHW-AB EHW-AB EHW-B0B EHW-BB EHWTA-B EHWTA-C0 EHWTA-C JAA EHWTA- EHW-AB EHW-AB EHW-AB EHWA-B0B EHW-BB EHWTA-B EHWTA-C0 EHWTA-C J72AA EHWTA- EHW-A EHW-A EHW-A EHW70A-B0B EHW-BB EHWTA-B EHWA-C0 EHWTA-C NOTE: Field installed Heater Packages are not approved for use with top supply opening models. These heater packages approved for use in dehumidification versions with hot gas reheat. Heater Packages - Field Installed "L" eries Left-Hand Units Air Conditioner Models -A00 Models 2/- -B00 Models 2/-3 -C00 Models -3 Heater Model # KW Heater Model # KW Heater Model # KW JLA EHWA02A-LB EHW02A-A0LB EHWA02-ALB J2LA EHWA02A-LB EHW02A-A0LB EHWA02-ALB EHWA2-B0LB JLA EHWA03-LB EHWA03-A0LB EHWA03-ALB EHWA03-ALB EHWA03-B0LB EHWA37-BLB EHWC03-C0L EHWA03-CL J3LA EHWA03-LB EHWA03-ALB EHWA03-ALB EHWA03-B0LB EHWA37-BLB EHWC03-C0L EHWA03-CL J2LA JLA EHWTA-L EHW-ALB EHW-ALB EHW-B0LB EHW-BLB EHWTA-C0L EHWTA-CL JLA EHWTA-L EHW-ALB EHW-ALB EHWA-B0LB EHW-BLB EHWTA-C0L EHWTA-CL J72LA EHWTA-L EHW-AL EHW-AL EHW70A-B0L EHW-BL EHWTA-C0L EHWTA-CL Form No. - upersedes - Page 7 of 2

Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE JAA, J2AA, JAA, J3AA " " J2AA, JAA, JAA, J72AA " " NOTE: For side-by-side installation of two (2) JA models, there must be " between units. This can be reduced to " by using a JL model (left side compressor and controls) for the left unit and JA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET JAA, J2AA 0" 0" JAA, J3AA /" 0" J2AA, JAA, JAA, J72AA /" 0" Refer to the Installation Manual for more detailed information. Dimensions of J-72AA Basic Unit for Architectural & Installation Requirements (Nominal) MODEL JAA J2AA JAA J3AA J2AA JAA JAA J72AA WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T.0 7.2 7.3 7.....00. 2.7..7.0.2 3.00 2.3 3.3 2.0.. 2.00.00 3.0 7.2 7.3 7. 27. 3. 27. 0.00. 2.7 7.3.7.7.2 3.00 2.7 3.3 2.7.. 2.00.00 2.07 22..7. 2.. 2. 3. 3. 3..00. 2. 3..3 3.37 3.00 23..00..00. 2.07 22. 3.000. 2.. 2. 3. 3. 37.00.00 0..0 2. 0. 3.37 3.00 3.00.00..00.00 W Built In Rain Hood Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for CRV and ECON models only D.2 2.3 A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O upply Air Opening B. R. F G Filter Access Panel Ventilation Air Condenser Air Outlet tandard flush vent door for non- ERV/CRV Econ. models 3" 7.00 Low Voltage Electrical Entrance High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Return Air Opening T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-37 Not used when WECO Economizers installed. Filter access is through the WECO hood. Form No. - upersedes - Page of 2

Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE JLA, J2LA, JLA, J3LA " " J2LA, JLA, JLA, J70LA " " NOTE: For side-by-side installation of two (2) JL models, there must be " between units. This can be reduced to " by using a JL model (left side compressor and controls) for the left unit and JA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET JLA, J2LA 0" 0" JLA, J3LA /" 0" J2LA, JLA, JLA, J70LA /" 0" Refer to the Installation Manual for more detailed information. Dimensions of J-72LA Basic Unit for Architectural & Installation Requirements (Nominal) MODEL JLA J2LA JLA J3LA J2LA JLA JLA J72LA WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T.0 7.2 7.3 7.....00. 2.7..7.0.2 3.00 2.3 3.3 2.0.. 2.00.00 3.0 7.2 7.3 7. 27. 3. 27. 0.00. 2.7 7.3.7.7.2 3.00 2.7 3.3 2.7.. 2.00.00 2.07 22..7. 2.. 2. 3. 3. 3..00. 2. 3..3 3.37 3.00 23..00..00. 2.07 22. 3.000. 2.. 2. 3. 3. 37.00.00 0..0 2. 0. 3.37 3.00 3.00.00..00.00 R E Heater O Pitch Access. Panel D W upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location Built In Rain Hood 2.3 A I.2 Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) tandard flush vent door for non-erv/crv Econ. models Hood for CRV and ECON models only Return Air Opening Optional Electrical Entrances C 3" Filter Access Panel Ventilation Air. F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View 7.000 Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-3737 Not used when WECO Economizers installed. Filter access is through the WECO hood. Form No. - upersedes - Page of 2

Cooling Application Data - Outdoor Temperature Model J J2 J J3 J2 J J J72 Return Air (DB/WB) 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 Cooling Capacity 7 F 0 F F 0 F F 0 F F F F F 2 F 700 300 0 300 2 0 2 000 200 00 0 0 20 3700 23700 00 20 00 20 0 0 3000 0 300 00 30 0 3700 300 370 0 300 0 0 00 0 30 0 70 0 700 300 700 3700 0 300 0 0 0 3 0 00 2 300 2 30 0 370 00 270 70 2700 0 0 0 0 300 0 3700 20 37000 00 370 00 0 700 70 700 700 7000 000 770 00 3700 0 700 300 0 00 20 00 2700 0 700 0 20 3 2 370 22700 0 270 30 0 00 27000 3700 0 0 300 700 3 00 300 00 700 3700 00 0 00 0 700 0 700 200 7 0 0 0 300 70 300 00 30 2200 00 2 00 0 270 2 30 2 0 200 300 3700 2700 2 00 300 0 300 0 30 300 00 0 00 0 700 00 20 700 00 00 0 730 0 700 00 30 7000 30 00 00 70 20 7700 2700 700 2 200 000 00 20 0 2 300 20 00 2 30 0 0 00 0 00 0 000 00 30 3700 0 300 00 0 00 0 0 700 000 700 000 Below F (.3C), unit requires a factory or field installed low ambient control. Return air temperature. 0 00 0 30 0 0 00 00 0 70 2 700 200 00 00 20 3700 0 00 200 00 200 3700 20 30 0 00 00 000 200 300 30 0 300 00 700 00 20 0 30 20 00 00 0 700 0 7 70 0 0 20 700 0 00 00 00 00 00 0 30 0 200 00 70 00 700 3700 20 0 0 700 00 000 70 00 0 0 0 00 00 0 2 200 00 00 0 00 700 0 700 7000 2300 20 0 20 00 700 23700 2 20 0 0 00 00 0 0 00 2700 0 20 200 2300 00 0 0 0 00 0 270 20 20 00 0 700 0 70 2700 0 0 2 200 2300 2 230 20 30 0 3 00 700 200 2700 20 20 20 37000 0 3000 30 2300 230 2 200 30 30 0 0 20 2700 270 2700 0 370 00 30 700 0 20 00 00 3700 370 700 700 20 27700 2700 20 200 00 3 300 700 0 00 0 3700 0 0 00 00 30 3700 30 3 300 00 3700 0 0 00 0 300 3 00 00 0 00 3700 0 00 30 30 0 0 00 700 0 00 000 300 00 370 00 700 7700 0 00 300 3700 300 300 30 00 70 00 00 00 30 00 0 00 700 7700 0 0 70 0 0 700 70 0 000 0 0 000 30 Capacity Multiplier Factors % of Rated Airflow - Rated + Total BTUH 0.7.0.02 ensible BTUH 0..0.0 Form No. - upersedes - Page of 2

Air Conditioning Wall-Mount Model Nomenclature ERIE NOMINAL CAPACITY - ½ Ton 2-2 Ton - 2½ Ton 3-3 Ton 2-3½ Ton - Ton - Ton 72 - Ton J 3 A A A 00 X P X X X J A = Compressor & Controls - Right ide L = Compressor & Controls - Left ide REVIION VOLT & PHAE A - 2/// B - 2///3 C - //3 KW VENTILATION OPTION (ee Table Below) FILTER OPTION P - 2-inch Pleated (MERV ) COLOR OPTION X - Beige (tandard) COIL OPTION X - tandard CONTROL MODULE (ee Chart Below) UPPLY AIR OUTLET X - Front (tandard) For 0KW and circuit breakers (2/ Volt) or toggle disconnects ( Volt) applications, insert 0Z in the KW field of the model number. ee Pages & for available Factory Installed KW options and Page 7 for Field Installed Heater Packages. Ventilation Options Models Description Factory Installed Code No. JAA, J2AA JLA, J2LA Field Installed Part No. Factory Installed Code No. JAA, J3AA JLA, J3LA Field Installed Part No. J2AA, JAA, JAA, J72AA J2LA, JLA, JLA, J72LA Factory Installed Field Installed Code No. Part No. Barometric Fresh Air Damper - tandard X BFAD-2 X BFAD-3 X BFAD- Economizer w/plug, Temp Only (7" Hood) Y WECOPT2-X Y WECOPT3-X Y WECOPT-X Economizer w/plug, Enthalpy (7" Hood) Z WECOPE2-X Z WECOPE3-X Z WECOPE-X Air Conditioning Control Modules All Models Except As Noted HPC LPC CCM LAC ALR K K Factory Installed Code Field Installed Part TD TD TD J Factory Only TD TD TD Field Installed Only CMC- K Except J & J72 TD TD TD Field Installed Only K2 J72 Only K22 J Only TD = tandard equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. CCM. Compressor control module has adjustable -second to -minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low pressure controls, and a 2-minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to 0 F. LAC is fan-cycling control for outdoor fan motor on all models. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. K. PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if K or K2 is used. K. tart capacitor & potential relay start kit can be used with all -A single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC- is used. Form No. - upersedes - Page of 2

NOTE Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. May, upersedes - Form No. - upersedes - Page 2 of 2