Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Similar documents
I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

RS-485 I/O Modules: ADAM-4000

Features and Benefits. Certifications

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

iologik E1200H Series

ET-7000 series Ethernet Remote I/O Module

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

Ethernet I/O Modules: ADAM-6000

iologik 4000 Series (M) Modules

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

iothinx 4500 Series (45MR) Modules

iologik 2500 Series Quick Installation Guide

Redundant System Redundant System P9-1-1

E2000 Series Active Remote I/O

Remote I/O Modules EH-RIO2 Series

Korenix JetI/O 6510 Industrial Intelligent Ethernet I/O Server User s Manual

Ethernet I/O Modules: ADAM-6000

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

S800 I/O ABB Automation

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Ethernet I/O Modules: ADAM-6000

iologik E1200 Series User s Manual

iologik E1200 Series User s Manual

ADAM-5511 User s Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual

Features and Benefits. Certifications

iologik E2200 Series User s Manual

Ethernet Remote I/O Modules. OME-ET-7000/ OME-PET-7000 Series. Features

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

ICP DAS. ICP DAS 2013 M2M ZigBee Wireless Solutions

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

PX Serial - Quick Start Guide

RTU32S RTU32S Series Small Compact Utility RTU

LGR-5325 Specifications

UK +44 (0) // USA // JAPAN //

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

NetBiter I/O Extender User Manual

Ethernet I/O Module by ICP DAS Co., Ltd. All Rights Reserved. Comparison Item tpet PETL-7000 PET-7000 CPU 32-bit ARM Ethernet

TM3TI4 module TM3-4 inputs temperature

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Korenix JetI/O 6511 Industrial Intelligent Ethernet I/O Server User Manual

WISE I/O Modules Overview P10-1-1

Active Ethernet Micro Controller User s Manual

900EN Series. Acromag RUN ST DIO STATUS ACT LINK DFT RST ETHERNET TB1

Specifications USB-1616HS

HWg-STE HWg-STE PoE MANUAL

Ethernet I/O Modules: ADAM-6000

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual

RTU32S RTU32S Series Small Compact Utility RTU

Industrial USB I/O Modules

ADAM-5000 Series. I/O Module User's Manual

BACnet Controller for General-purpose Building Applications

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Korenix JetI/O 6512 Industrial Intelligent Ethernet I/O Server User Manual

VersaMax Micro and Nano Technical Product Presentation

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

TM3TI4 module TM3-4 inputs temperature

USB-2527 Specifications

MOD-MUX MODBUS TCP I/O PRODUCTS

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

ADAM-6000 Series. Ethernet-based Data Acquisition and Control Modules. User Manual

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

HRM-0800 Instruction Manual

Features and Benefits. Certifications

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

AI-917-A0. Analogue Input Module (4x 0-20 ma)

TM221CE40R controller M IO relay Ethernet

Remote I/O Product Specification

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

Related Products. 1. CAN Bus to Ethernet Gateway 2. Serial Device to Ethernet Gateway. Wireless ZigBee Series. Ethernet Layer.

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Features and Benefits. Certifications

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

Select a Micro800 Controller

ON 1 2 NT-V A 321S DIMENSIONS FRONT VIEW 4xΦ (UNIT: mm) INPUT RANGE & MODE SELECTION SW1 SW2 +Ch5 -Ch5 +Ch6 -Ch6 +Ch7 -Ch

Features and Benefits. SNMP MIB-II for network management. Certifications

Operation Manual of EX9132CST-Series

MIC-2 MKII, Multi-instrument DATA SHEET

Submittal Data Sheet WAGO Node for itm

Features. RoHS COMPLIANT 2002/95/EC

Internet Camera Quick Installation Guide

icex-cmtm General specs and Installation guide

TM221CE24T controller M IO transistor PNP Ethernet

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

ProfiPro Distributed PROFIBUS I/O Modules User Manual

ADAM-5000 Series. I/O Module User's Manual. Copyright Notice

LGR-5327 Specifications

Transcription:

Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities Web server service and SNMP for I/O monitoring Instant event reporting by SNMP trap Built-in watchdog timer and real-time clock Configurable output power-on & safe status setting Built-in simple condition rules for I/O logic programming Peer-to-peer I/O over TCP/IP Easy-installation DIN-rail mounting Support SDK API library and sample program in C#, C++, VB and BCB :. Introduction Leader-5000 is a series of Ethernet-based block I/O modules for distributive monitoring and controls. The block I/O modules feature built-in RSIC-based processor with MAC, and capable of performing analog I/O, digital I/O, and temperature measurement in an Ethernet network with Modus/TCP protocol at LAN, intranet or Internet. Versatility Communication Network A Leader-5000 I/O module can simultaneously serve communication from different Ethernet socket ports. For example, HTTP, HAL Windows-based utility and Modbus/TCP Server. OPC server and various C++/C Modbus/TCP communication driver are provided for user to choose the easiest way to have the Leader-5000 block modular I/Os to go with his self developed software or HMI/SCADA package. :. Leader 5000 Appearance

:. System Features Model Name I/O System Software Communication Protocol CPU Programming Ethernet SDRAM Flash EEPROM Peer-to-Peer DIN-rail Mounting Remote Monitoring Network Server SDK Provided Utility OPC Server Driver Modbus/TCP Leader-5000 Series 8-bit, RISC-Based 100MHz Condition Logic Rule 1 x 10/100 Mbps, RJ-45 32 KB 512 KB 256 bytes YES YES Web Server Http, SNMP C/C++, C#, VB, BCB Block I/O Utility YES YES :. Block I/O Utility Quick to Use Windows Utility Block I/O Utility allows you to configure and monitor Leader-5000 Series Ethernet-Based I/O modules remotely. The Utility automatically scanning installed Leader-5000 Ethernet-Based Block I/O modules. With Block I/O utility, you can browse available units, view the status of each channel, configure the I/O settings and configure the active I/O logic rule and alarms. The General Page (LD-5000 Series) The I/O Status Page, it can monitor the current working status of each channel both on DI and DO and Peer to Peer I/O Active

Status The I/O Configuration Page, it can configure the DI/DO mode and check status for each channel. DI/ Event Counter channel configuration and test, power on settings, safe status settings. DO/ Pulse Output channel configuration and test, power on settings, safe status settings.

Condition Logic Rule The I/O logic rule provides one-time operation in each entry. The theory is the same as the IF-Then rule. It s easy to understand rules, no need to know extra program script to configure this. In Logic Rule #ID Configuration page, select Enable and configure the Condition and Actions then press Apply to enable the rule. When the Conditions is reached, the system automatically activates the Actives. The maximum I/O logic rules for Leader-5068 support are up to 7 rules. Each rule can support up to 4 different conditions and 4 different actions. The Alarm page, easy to configure the I/O logic rules, alarm message and peer to peer I/O activity. Support up to 4 different conditions and 4 different actions. SNMP Trap SNMP Trap Setting: Configure up to 3 SNMP Trap Server s IP in the LD-5068. SNMP Trap Setting: Configure up to 4 SNMP Trap Server s IP in the LD-5017/LD-5018/LD-5014/LD-5024. Peer to Peer Enable Peer to Peer I/O activity: Configure module s input channels mirrored to remote IP Configure module s output channels mirrored from remote IP

Ethernet-Based I/O Status via Web Browser Enter the IP address of the Ethernet-Based Block I/O Modules in Internet Explorer. Then you can access the embedded web browser of the I/O server. The web browser allows you monitor the information/status of each channels. Monitor the I/O status through any web browser. (The above sample is for LD-5068 digital I/O module) :. Dimensions

:. Specifications COMMON SPECIFICATIONS CPU: RISC-Based, 100MHz SDRAM: 32K bytes Flash: 512K bytes EEPROM: 256 bytes Watch Dog Timer: 1.0 sec H/W Network Protocols: Modbus/TCP, TCP/IP, UDP, SNMP, HTTP, TFTP, BOOTP, DHCP Ethernet: IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX Bus Connection: RJ-45 modular jack, Auto MDI/MDI-X Protection: 1.5 KV magnetic isolation protection Serial Interface: RS-232, 2m JTAG PIN Power Input Connector: 24VDC, 3-pin, 5mm pitch LED Indication: PWR: Power Input Green ON RDY: System Ready Red ON LAN Activity Orange ON/Blinking LAN Speed 100M/10M Green ON/OFF Mechanical: ABS with Standard DIN-rail mounting I/O Wiring Connector: 16-pin, 20-pin, 24-pin screw terminal, 5mm pitch Dimensions (W x H x D): 40 x 108 x 73.48mm Power Input Requirements: System Power: 24VDC nominal, 1.92W Field (I/O) Power: 24 VDC nominal, 15 to 32 VDC GENERAL ENVIRONMENT Operating temperature: 0 ~ 50 C Storage temperature: -20 ~ 70 C Humidity (Operating): 20 ~ 90% non-condensing SOFTWARE Network Server: Http, SNMP SDK Provided: C/C++, C#, VB, BCB Utility: Block I/O Utility OPC Server Driver: YES

Leader-5068 Ethernet-based 14-CH DI Isolated and 8-CH Isolated DO Module DIGITAL OUTPUT DIGITAL INPUT Input Channels: 14 Input Type: sink type Input Mode: D/I or event counting with input frequency of 100 Hz max. DC Input: 30V max. Threshold Voltage: 4V Responding Time to Host PC Request: <2ms Output Channels: 8 Output Type: source type Output Mode: Level or pulse output with programmable pulse width Working Range: 5-40VDC Driving Capacity: 150mA max. Responding Time to Host PC Request: <2ms Output Initial State: Programmable Isolation Voltage: 1500VAC POWER REQUIREMENT Power Consumption: 100mA @ 24VDC max. Field (I/O) Power: 24VDC nominal, 18 to 32 VDC Leader-5017 Ethernet-based 8-CH Isolated Analog Input Module ANALOG INPUT Channels: 8, differential Resolution: 16-bit Programmable Input Range: Supports Different Input Range for Different Channels Voltage: ±10V, ±5V, ±1V, ±500mV, ±150mV Current: ±20mA (Jumper Setting Enabled 125Ω Resistor) Accuracy: ±0.05% of FSR ±1LSB Sampling Rate: 10 samples/sec (total) Input Impedance: 10 MΩ Calibration: On Board EEPROM POWER REQUIREMENTS Power Consumption: 125mA @ 24VDC max.

Leader-5018 Ethernet-based 8-CH Isolated Thermocouple Input Module ANALOG INPUT (Voltage, Current and Thermocouple) Channels: 8, differential Resolution: 16-bit Input Type: Thermocouple (T/C), mv, V, ma Programmable Input Range: Supports Different Input Range for Different Channels Voltage: ±2.5V, ±1V, ±500mV, ±100mV, ±50mV, ±15mV Current: ±20mA (Jumper Setting Enabled 125Ω Resistor) Thermocouple: K/J/N/C/E/B/T/R/S T/C Type Range K -100 C ~ 1000 C J -100 C ~ 900 C N -270 C ~ 1300 C C 10 C ~ 2310 C E -240 C ~ 2310 C B 0 C ~ 1800 C T -270 C ~ 400 C R -50 C ~ 1530 C S -50 C ~ 1700 C Accuracy: ±0.1% of FSR ±1LSB Sampling Rate: 10 samples/sec (total) Input Impedance: 10 MΩ Calibration: On Board EEPROM POWER REQUIREMENTS Power Consumption: 130mA @ 24VDC max. Leader-5014 Ethernet-based 4-CH Isolated RTD Input Module RTD INPUT Channels: 4 RTD Resolution: 16-bit Input Type: Pt100 and Ni120 RTD Input Connections: 3, 4 or 5 wire Programmable RTD Input Range: Supports Different Input Range for Different Channels Pt100 (-100 C ~ 100 C α=0.00385) Pt100 (0 C ~ 100 C α=0.00385) Pt100 (0 C ~ 200 C α=0.00385) Pt100 (0 C ~ 600 C α=0.00385) Pt100 (-100 C ~ 100 C α=0.00392) Pt100 (0 C ~ 100 C α=0.00392) Pt100 (0 C ~ 200 C α=0.00392) Pt100 (0 C ~ 600 C α=0.00392) Nickel 120Ω (-80 C ~ 260 C α=0.00672) Accuracy: ±0.1% of FSR ±1LSB Sampling Rate: 10 samples/sec (total) Input Impedance: 10 MΩ Calibration: On Board EEPROM

POWER REQUIREMENTS Power Consumption: 125mA @ 24VDC max. Leader-5024 Ethernet-based 4-CH Isolated Analog Output Module ANALOG OUTPUT Channels: 4(voltage or current), differential Resolution: 12-bit Output Range: 0-20mA (sink), 0-10V, ±10V Output Impedance: 0.5Ω Current Load Resistor: 0 to 500Ω (source) Programmable Output Slope to Safety Value: 0.125 to 128 ma/sec (Current) 0.0625 to 64 V/sec (Voltage) Accuracy: ±0.1% of FSR ±1LSB Calibration: On Board EEPROM POWER REQUIREMENTS Power Consumption: 132mA @ 24VDC max. Order Information ETHERNET-BASED BLOCK I/O MODULES Leader-5068 Ethernet-based 14-CH Isolated DI and 8-CH Isolated DO Module Leader-5017 Ethernet-based 8-CH Isolated Analog Input Module Leader-5018 Ethernet-based 8-CH Isolated Thermocouple Input Module Leader-5014 Ethernet-based 4-CH Isolated RTD Input Module Leader-5024 Ethernet-based 4-CH Isolated Analog Output Module