Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Similar documents
The Near Future in Cardiac CT Image Reconstruction

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

Reconstruction from Projections

SPECT reconstruction

Acknowledgments and financial disclosure

Motion Compensation from Short-Scan Data in Cardiac CT

DUE to beam polychromacity in CT and the energy dependence

F3-A5: Toward Model-Based Reconstruction in Scanned Baggage Security Applications

Non-Stationary CT Image Noise Spectrum Analysis

GPU implementation for rapid iterative image reconstruction algorithm

Gengsheng Lawrence Zeng. Medical Image Reconstruction. A Conceptual Tutorial

Image Acquisition Systems

Moving Metal Artifact Reduction for Cone-Beam CT (CBCT) Scans of the Thorax Region

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Deep Scatter Estimation (DSE): Feasibility of using a Deep Convolutional Neural Network for Real-Time X-Ray Scatter Prediction in Cone-Beam CT

Make the Most of Time

Estimating 3D Respiratory Motion from Orbiting Views

Automatic Intrinsic Cardiac and Respiratory Gating from Cone-Beam CT Scans of the Thorax Region

Computer-Tomography II: Image reconstruction and applications

Digital Image Processing

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Performance Evaluation of CT Systems

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Henry Ford NERS/BIOE 481. Lecture 11 B Computed Tomography (CT)

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization

Scaling Calibration in the ATRACT Algorithm

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

ML reconstruction for CT

Medical Image Reconstruction Term II 2012 Topic 6: Tomography

Suitability of a new alignment correction method for industrial CT

Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network

A new calibration-free beam hardening reduction method for industrial CT

Central Slice Theorem

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Index. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting

Noise weighting with an exponent for transmission CT

Iterative Reconstructions: The Impact on Dose and Image Quality

Algebraic Iterative Methods for Computed Tomography

Introduc)on to PET Image Reconstruc)on. Tomographic Imaging. Projec)on Imaging. Types of imaging systems

MOTION of a patient induces artifacts such as streaks

Adaptive Reconstruction Methods for Low-Dose Computed Tomography

Medical Image Processing: Image Reconstruction and 3D Renderings

Advanced Image Reconstruction Methods for Photoacoustic Tomography

BME I5000: Biomedical Imaging

Tomographic Reconstruction

A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section

F3-A5: Model-Based Iterative Reconstruction for Advanced Baggage Screening

Acknowledgments. Nesterov s Method for Accelerated Penalized-Likelihood Statistical Reconstruction for C-arm Cone-Beam CT.

CT Iterative Reconstruction Techniques

Total Variation and Tomographic Imaging from Projections

Axial block coordinate descent (ABCD) algorithm for X-ray CT image reconstruction

Translational Computed Tomography: A New Data Acquisition Scheme

Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT. y i Poisson I i (E)e R } where, b i

Frequency split metal artifact reduction (FSMAR) in computed tomography

AIDR 3D Iterative Reconstruction:

Radon Transform and Filtered Backprojection

GPUs in CT Reconstruction. Logan Johnson

Towards full-body X-ray images

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Cardiac Dual Energy CT: Technique

A Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT

Flying Focal Spot (FFS) in Cone-Beam CT Marc Kachelrieß, Member, IEEE, Michael Knaup, Christian Penßel, and Willi A. Kalender

CIVA Computed Tomography Modeling

Attenuation map reconstruction from TOF PET data

Investigation on reconstruction methods applied to 3D terahertz computed Tomography

Fast iterative beam hardening correction based on frequency splitting in computed tomography

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Introduction to Medical Imaging. Cone-Beam CT. Klaus Mueller. Computer Science Department Stony Brook University

Quality control phantoms and protocol for a tomography system

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Unmatched Projector/Backprojector Pairs in an Iterative Reconstruction Algorithm

Computer-Tomography I: Principles, History, Technology

USING cone-beam geometry with pinhole collimation,

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Tomography at all Scales. Uccle, 7 April 2014

Feldkamp-type image reconstruction from equiangular data

Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

Carbondale, IL USA; University of North Carolina Chapel Hill, NC USA; USA; ABSTRACT

An approximate cone beam reconstruction algorithm for gantry-tilted CT

Metal Streak Artifacts in X-ray Computed Tomography: A Simulation Study

High Resolution Iterative CT Reconstruction using Graphics Hardware

COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

Introduction to Biomedical Imaging

CIVA CT, an advanced simulation platform for NDT

SINGLE-PHOTON emission computed tomography

Continuous and Discrete Image Reconstruction

Transcription:

Spiral ASSR Std p = 1.0 Spiral EPBP Std p = 1.0 Kachelrieß et al., Med. Phys. 31(6): 1623-1641, 2004 256 slices (0/300)

Advantages of Cone-Beam Spiral CT Image quality nearly independent of pitch Increase of scan speed of z-resolution New applications CT angiography dynamic studies virtual endoscopy cardiac CT DECT Today, complete anatomical regions are routinely scanned with cone-beam spiral CT within a few seconds with isotropic submillimeter spatial resolution.

Iterative Image Reconstruction

Model Update equation Modified from Johan Nuyts, New image reconstruction techniques, ECR 2012

Influence of Update Equation and Model

Analytical Reconstruction 1. Problem 2. Solution 3. Discretisation Classical Iterative Reconstruction 1. Problem 2. Discretisation 3. Solution

Linear System and CT System Matrix Radon or x-ray transform image to be reconstructed measured rawdata

Kaczmarz s Method

Kaczmarz s Method (2) Successively solve To do so, project onto the hyperplanes Repeat until some convergence criterion is reached

Kaczmarz s Method (3)

Kaczmarz in Image Reconstruction: Algebraic Reconstruction Technique (ART)

Flavours of Iterative Reconstruction ART SART MLEM OSC and dozens more

Iterative Region of Interest (IROI) ROI forward project FBP xy Full = 0.25 mm FBP with clipped ROI reconstruct analytically = reconstruct iteratively Sinogram ROI sinogram IROI reconstruction xy ROI = 0.04 mm A. Ziegler, T. Nielsen, and M. Grass, Iterative Reconstruction of Region of Interest for Transmission Tomography, Med. Phys. 35 (4), Mar. 2008

Iterative Reconstruction: Parameters Image/object representation Pixel centers Pixel area Blobs Sampling density (pixel size, pixel locations, ) Forward model (forward projection) Joseph-type, Bresenham-type, distance-driven-type, Needle beam (infinitely thin ray), many needle beams per ray, Beam shape (varying beam cross-section, angular blurring, ) Physical effects (beam hardening, scatter, motion, detector sensitivity, nonlinear partial volume effect, ) Objective function, update equation Statistical model (Gaussian, Poisson, shifted Poisson, ) Regularisation (edge-preserving, ) Artifact reduction Inverse model (backprojection) Transpose of forward model Pixel-driven backprojection Filtered backprojection

Image Representation

Image Representation

Image Representation

Forward Model: Beam Shape

Forward Model: Beam Shape

Forward Model: Beam Shape

Forward Model: Beam Shape

Forward Model: Beam Shape

Forward Model: Beam Shape

Image Representation and Forward Model are Linked! Joseph s forward projector

Objective Function: Gauß Model Assume that the attenuation is Gaussian-distributed i.e. with. Consequently, the likelihood for all N measured signals is ( ): Before maximizing take the log, penalize roughness, and then find the image f that maximizes L.

This leads us to minimizing which means solving This must be done numerically (e.g. Jacobi method) and the solutions are often of type

Update Equation: Gauß Model ART SART and many more

Objective Function: Poisson Model Assume that the intensities are Poisson-distributed which means with. Consequently, the likelihood for all N measured signals is ( ): Before maximizing take the log, penalize roughness, and then find the image f that maximizes L.

Update Equation: Poisson Model MLEM OSC and many more

Native OSC Converges Slowly OSC 8 OSC 128 FBP σ=44 HU σ=67 HU (C=0, W=100) OSC 128 FBP (C=0, W=150) OSC 4

Proper Initialization Helps! OSC 4, initialized with OSC 4, initialized with constant value matched FBP OSC 4, initialized with smooth FBP (C=0, W=150) σ=67 HU σ=33 HU (C=0, W=100) FBP image subtracted. Insufficient image quality Same noise as FBP 50% less noise than FBP

Ordered Subsets Divide one iteration into S sub-iterations. Each of these S subsets covers N/S projections. During one iteration all subsets and therefore all projections are used exactly once. Per iteration the volume is updated S times (once per sub-iteration). An up to S-fold speed-up can be observed.

Ordered Subsets Illustration for N = 32 Projections Conventional procedure without subets (S = 1) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Ordered subsets with S = 8 sub-iterations 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Ordered Subsets 29 30 31 27 28 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 N Projections = 32, Ordered Subsets: N Subsets = 8

Sequence Can be Generated Using Simple Bit Reversal 0 -> 0 1 -> 16 2 -> 8 3 -> 24 4 -> 4 5 -> 20 6 -> 12 7 -> 28 8 -> 2 9 -> 18 10 -> 10 11 -> 26 12 -> 6 13 -> 22 14 -> 14 15 -> 30 16 -> 1 17 -> 17 18 -> 9 19 -> 25 20 -> 5 21 -> 21 22 -> 13 23 -> 29 24 -> 3 25 -> 19 26 -> 11 27 -> 27 28 -> 7 29 -> 23 30 -> 15 31 -> 31

Iterations S = 1 (no subsets) S = 32 (ordered subsets) 512 iterations 16 iterations 512 iterations 16 iterations C = 0 HU, W = 1000 HU

Image Updates S = 1 (no subsets) S = 32 (ordered subsets) 512 updates 512 updates 512 updates 512 updates C = 0 HU, W = 1000 HU

What Makes Iterative Recon Attractive? No need to come find an analytical solution Works for all geometries with only small adaptations Allows to model any effect Allows to incorporate prior knowledge noise properties (quantum noise, electronic noise, noise texture, ) prior scans (e.g. planning CT, full scan data, ) image properties such as smoothness, edges (e.g. minimum TV) Handles missing data implicitly (but not necessarily better) Phase-correlated Feldkamp High dimensional TV minimization 1 1 L. Ritschl, S. Sawall, M. Knaup, A. Hess, and M. Kachelrieß, Phys. Med. Biol. 57, Jan. 2012

Iterative!= Iterative In many cases artifact correction is iterative Higher order beam hardening correction Cone-beam artifact correction Scatter correction Practical iterative reconstruction approaches often use empirical solutions combine iterative with analytical reconstruction combine iterative or analytical reconstruction with image restoration Phase-correlated Feldkamp Low dose phase-correlated (LDPC) recon 1 1 S. Sawall, F. Bergner, R. Lapp, M. Mronz, A. Hess, and M. Kachelrieß, MedPhys 38(3), 2011

Aim: less artifacts, lower noise, lower dose Iterative reconstruction Reconstruct an image. Regularize the image. Does the image correspond to the rawdata? If not, reconstruct a correction image and continue. SPECT + PET are iterative for a long time. Until recently, the computational demand prohibited to use iterative recon in CT. First CT product implementations AIDR (adaptive iterative dose recuction, Toshiba) ASIR (adaptive statistical iterative reconstruction, GE) idose (Philips) Iterative Reconstruction IRIS (image reconstruction in image space, Siemens) VEO, MBIR (model-based iterative reconstruction, GE) SAFIRE (sinogram-affirmed iterative reconstruction, Siemens)

Conventional reconstruction at 100% dose Iterative reconstruction and restoration at 40% dose Images provided by Siemens Healthcare, Forchheim, Germany

Conventional reconstruction at 100% dose Iterative reconstruction and restoration at 40% dose Images provided by Siemens Healthcare, Forchheim, Germany

Conventional reconstruction at 100% dose Iterative reconstruction and restoration at 40% dose Images provided by Siemens Healthcare, Forchheim, Germany

100% dose 50% dose 50% dose + IRIS Image courtesy of Prof. Dr. Michael Lell, Erlangen, Germany

Summary Conventional recon at 100% dose Analytical image reconstruction is compute efficient requires new solutions for new trajectories is what most images are reconstructed with Iterative image reconstruction requires much more computational effort allows to easily model constraints allows to incorporate prior knowledge Practical modern solutions often are a combination of analytical and iterative recon are offered by the major manufacturers of diagnostic CT Iterative reconstruction and restoration at 40% dose Images provided by Siemens Healthcare, Forchheim, Germany

Thank You! This presentation will soon be available at www.dkfz.de/ct. The iteration videos were prepared by my colleague Christian Hofmann.