Air Damper Actuators Modbus RTU

Similar documents
Air Damper Actuators Modbus RTU

VAV Compact Controller Modbus RTU

Electromotive actuators for valves

Rotary actuator for ball valves KNX / PL-Link

Rotary version, three-position control

Rotary actuators for ball valves

Air damper actuators

Fast running actuators for air dampers

VAV compact controller

VAV modular controller

Handheld Tool for VAV compact and modular controllers

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Electromotoric actuators for stroke valves

VAV compact controller KNX / PL-Link

Digital input modules

VAV compact controller GDB181.1E/3 GLB181.1E/3

OpenAir Rotary damper actuators without spring return GDB/GLB Technical basics

TXM1.8RB. TX-I/O Blinds module

BACnet/IP Web Interface

VAV modular controller

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Super universal modules

Interface converter for VAV compact controllers

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Electromotive actuators for combi valves

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Mobile Data Collector

Airflow Pressure Sensor

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Room unit with PPS2 interface

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Fume Hood Cable Sash Sensor

Electromotoric actuators

Touch Panels 10.1" and 15.6"

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Power consumption In operation At rest For wire sizing

RMZ790. Operator Unit. Building Technologies. Synco 700

Technical data sheet. Technical data

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

Electromotoric actuator

Electromotoric actuators

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Technical data sheets

Island bus expansion module

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Climatix programmable controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Room Temperature Controller

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Technical data. Safety notes. Product features

Resistance measuring module

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power supply module, bus connection module

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Network node WTT56.. A6V _en--_c Building Technologies

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

QSA2700D / QSA2700 / AQS2700 Fine dust room sensor Basic Documentation

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Room unit with PPS2 interface

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Semi flush-mounted room temperature controllers with LCD

Variable Flow Rate Control Unit

AEW Pulse Adapter. Building Technologies

N05010/N10010 NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / 2-POSITION CONTROL SPECIFICATIONS

OpenAir TM VAV compact controller G..B181.1E/3 VAV modular controller ASV181.1E/3. Technical Basics. Infrastructure & Cities

RA Electric Rotary Actuator 20 Nm to 60 Nm for butterfly valves

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Web interface BACnet/IP

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

HVAC&R controller. Climatix C600. POL648.x0, POL688.x0, POL69x.x0

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

OpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return

Heating Circuit Controller

Touch Panels 10.1" and 15.6"

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Actuators for CAV control lers

N0524/N1024, N POS/N POS

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Transcription:

s OpenAir Air Damper Actuators Modbus RTU GEB.., GIB.. Non-spring return types Damper actuators 15 Nm / 35 Nm (non-spring return) with Modbus communication GEB.. 15 Nm nominal torque GIB.. 35 Nm nominal torque Modbus RTU communication Operating voltage AC 24 V For air-handling units (AHU) and other ventilation applications 2017-02-17 Building Technologies

Functions Function Communication Description Modbus RTU (RS-485), not galvanically separated Functions - Setpoint and actual position 0..100% Supported baudrates Supported transmission formats Termination - Override control Open / Close / Min / Max / Stop - Setpoint monitoring and backup mode 9.6, 19.2, 38.4, 57.6, 78.4, 115.2 kbaud 1-8-E-1, 1-8-N-1-, 1-8-O-1, 1-8-N-2 120 Ω electronically switchable Type summary Product no. Stock no. Operating voltage Positioning signal GEB161.1E/MO S55499-D298 6 VA / 5.5 W max.1) AC 24 V Modbus RTU GIB161.1E/MO S55499-D299 8 VA / 8 W max. 1) 1) max. = actuator rotates Power consumption Posit. time Manual adjuster Position feedback 150 s Yes Yes Accessories / Spare parts GEB.. GIB.. Please refer to data sheet N4697 Please refer to data sheet N4699 Ordering (Example) Product no. Stock no. Description Amount GEB161.1E/MO S55499-D298 Damper actuator Modbus 1 + accessories (shaft inserts, etc.) Equipment combinations Product no. Stock no. Doc. type Doc. number POL424.50/STD S55394-C245-A100 Datasheet Q3973 POL424.70/STD S55394-C247-A100 Operating manual P3973 POL635.00/STD BPZ:POL635.00/STD Datasheet Q3230 Operating manual P3903 POL638.00/STD BPZ: POL638.00/STD Datasheet Q3900 POL638.70/STD S55396-C387-A100 Operating manual P3903 2 / 14 Building Technologies 2017-02-17

Product documentation Title Topic Document ID Rotary damper actuators without spring return GEB.. Rotary damper actuators without spring return GIB.. Detailed information about rotary actuators (15 Nm) Detailed information about rotary actuators (35 Nm) Z4621 Z4626 Climatix AHU Application Application description A3975 Installation Instruction Installation of types with external Modbus interface A6V101006034 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Notes Safety Caution National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage. Observe national provisions and comply with the appropriate safety regulations. Mounting Note: Do not open the damper actuators Mounting positions IP54 protection in following mounting positions IP54 90 3 / 14 2017-02-17 Building Technologies

Commissioning Workflow 1 The devices are especially designed for using the Climatix push-button configuration as described in document A3975 1). The bus configuration can alternatively be parameterized by the local HMI, cf. page 5. During commissioning check/set the following: Bus configuration (address, baudrate, transmission mode, and optionally termination). The default address 255 allows to mount and power multiple actuators at the same time without interfering with each other. Damper actuator parameters (opening direction, position limits, position adaptation etc.) can be checked via the Modbus register. 1) The documents can be downloaded from http://siemens.com/bt/download Workflow 2 The devices can be configured over bus if the pre-commissioning settings allow for a connection between the Modbus master / programming tool and peripheral devices (i.e. nonconflicting addresses and matching baudrate / transmission format). Full configuration over bus: If the address is unique per segment when powered up, the device can be accessed by the Modbus master (or programming tool) and the address and other parameters can then be set to the definitive values. Partial configuration over bus: If the address is not unique per segment when powered up, each device must get a non-conflicting address before connecting it to the bus, either by using the address input with push button (cf. page 6) or by setting the address to 246 with push button press > 5s und < 10s (cf. page 5). After addressing all devices, the remaining configuration can be done over the bus using the default settings for baudrate (auto-baud) and transmission mode for the Modbus master. Overwriting the bus configuration over bus uses a timeout. If 1 = Load is not written into Reg 768 within 30 seconds, all values are discarded. Example: Table shows bus configuration registers before and after changing them over bus. Reg. Name Pre-commissioning New value (ex.) 764 Modbus Address 246 12 765 Baudrate 0 = auto 1 = 9600 766 Transmission Format 0 = 1-8-E-1 3 = 1-8-N-2 767 Termination 0 = Off 0 = Off Maintenance Disposal 768 Bus Conf. Command 0 = Ready 1 = Load The damper actuators are maintenance-free. Disconnect the electrical connections from the terminals if you want to work at the device. The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Warranty Technical data on specific applications are valid only together with products listed under "Equipment combinations". rejects any and all warranties in the event that third-party products are used. 4 / 14 Building Technologies 2017-02-17

HMI (Human-Machine Interface) Push-button operation Activity Push-button operation Confirmation Display current address (starting with lowest address digit) Turn bus termination on / off Press button < 1s 1-digits: red 10-digits: green 100-digits: orange If termination is switched on, LED flashes 1x blue after address display Example: 124 = 4x red, 2x green, 1x orange turn on 1. press 3x LED flashing and flickering stops (termination mode) 2. press 1x shortly LED flashes 1x blue 3. press button until LED shines red LED shines red (confirmation) 4. release button LED off Address display LED flashes 1x blue after address display Normal operation Enter Modbus address with pushbutton Enter push-button addressing mode (for use with Climatix TM controllers) turn off 1. press 3x LED flashing and flickering stops (termination mode) 2. press button until LED shines red LED shines red (confirmation) 3. release button Normal operation Press button > 1s and < 5s See chapter Push-button addressing below 1. Press button > 5s and < 10s 2. Release button LED shines red and gets dark after 5s LED shines orange Reset to factory settings Press button > 10s LED flashes orange LED colors and patterns Color Pattern Description Green 1s on / 5s off Normal operation ( life pulse ) without bus traffic flashing Normal operation ( life pulse ) with bus traffic Orange / green 1s orange / 1s green Device is in override control Orange 1s on / 1s off Bus parameters not yet configured 1s on / 5s off Backup mode entered Red Steady Mechanical fault, device jammed or manual override 1s on / 5s off Internal error 0.1s on / 1s off Invalid configuration, e.g. Min = Max Blue Flashes 1x after address display Bus termination is set active. 5 / 14 2017-02-17 Building Technologies

Resetting the device by push button 1. Press button for >10s LED starts flashing orange 2. Release button while LED still flashes LED keeps flashing for 3s 3. If the button is pressed within these 3s, the reset is cancelled. 4. After those 3s LED shines red (reset), then the device restarts. Push-button addressing Display current address (starting with lowest address digit) The Modbus address can be set without a separate tool by using the push-button and LED. To display the current address, press button <1s. Colors 1-digits: red 10-digits: green 100-digits: orange Example for address 124: LED Note The address is entered and shown starting with lowest address digit, see figure above. (124 in the example is starting with 4x red) Set new address (starting with lowest address digit) 1. Enter addressing mode: press button > 1s until LED shines red, then release button (before LED gets dark). 2. Enter digits: press button n-times LED flashes per button press (feedback). Colors: 1-digits: red / 10-digits: green / 100-digits: orange 3. Store digits: press button until LED shines in color of following digits release button, 4. Save address: press button until LED shines red (confirmation) release button. An address can be stored at any time, i.e. after setting the 1-digits, or after setting the 1- and the 10-digits. 5. Entered address is repeated one times for confirmation. Note: If button is released before LED shines red, the address is discarded. 6 / 14 Building Technologies 2017-02-17

Examples Set address 124 : 1. Enter addressing mode 2. Set 1-digits: Press button 4-times LED flashes red per button press 3. Store 1-digits: press button until LED shines green release button 4. Set 10-digits: Press button 2-times LED flashes green per button press 5. Store 10-digits: press button until LED shines orange release button 6. Set 100-digits: Press button 1-times LED flashes orange per button press 7. Store address: press button until LED shines red release button address is stored and displayed 1x for confirmation Set address 50 : 1. Enter addressing mode 2. Skip 1-digits: Hold button pressed until LED shines green release button 3. Set 10-digits: Press button 5-times LED flashes green per button press 4. Store address (skip 100-digits): hold button pressed until LED shines red release button address is stored and displayed 1x for confirmation Set address 5 : 1. Enter addressing mode 2. Set 1-digits: Press button 5-times LED flashes green per button press 3. Store address: press button until LED shines red address is stored and displayed 1x for confirmation 7 / 14 2017-02-17 Building Technologies

Modbus registers Reg. Name R/W Unit Scaling Range / enumeration Process Values 1 Setpoint RW % 0.01 0..100 2 Override control RW -- -- 0 = Off / 1 = Open / 2 = Close 3 Actual position R % 0.01 0..100 3 = Stop / 4 = GoToMin / 5 = GoToMax 256 Command RW -- 0 = Ready / 1 = Adaption / 2 = Selftest 3 = ReInitDevice / 4 = RemoteFactory Reset Parameters 257 Opening direction RW -- -- 0 = CW / 1 = CCW 258 Adaptive Mode RW -- -- 0 = Off / 1 = On 259 Operating Mode RW -- -- 1 = POS 260 MinPosition RW % 0.01 0..100 261 MaxPosition RW % 0.01 0..100 262 Actuator Running Time R s 1 150 513 Backup Mode RW -- -- 0 = Go to BackupPosition 514 Backup Position RW % 0.01 0..100 1 = Keep last position 2 = Disabled 515 Backup Timeout RW s 1 0..65535 516 Startup Setpoint RW % 0.01 0..100 764 Modbus Address RW -- -- 1..247 / 255 = unassigned 765 Baudrate RW -- -- 0 = auto / 1 = 9600 / 2 = 19200 3 = 38400 / 4 = 57600 / 5 = 76800 6 = 115200 766 Transmission Format RW -- -- 0 = 1-8-E-1 / 1 = 1-8-O-1 2 = 1-8-N-1 / 3 = 1-8-N-2 767 Bus Termination RW -- -- 0 = Off / 1 = On 768 Bus Conf. Command RW -- -- 0 = Ready / 1 = Load / 2 = Discard 769 Status R -- -- See below, Register 769 Status Device information 1281 Factory Index R -- -- 1282-83 Factory Date R -- -- 1284-85 Factory SeqNo R -- -- 1409-16 TypeASN [Char_16..1] R -- -- 1) The documents can be downloaded from http://siemens.com/bt/download Cf. product documentation Z4621 / Z4626 1) Register 769 Status Status Bit 00 1 = reserved Bit 06 1 = Adaption done Bit 01 1 = Backup mode active Bit 07 1 = Adaption in progress Bit 02 1 = reserved Bit 08 1 = Adaption error Bit 03 1 = reserved Bit 09 1 = Selftest failed Bit 04 1 = Mechanical fault, device Bit 10 1 = Selftest passed jammed or manual override Bit 05 1 = Nom. lifetime exceeded Bit 11 1 = Invalid configuration 8 / 14 Building Technologies 2017-02-17

Supported function codes Function codes 03 (0x03) Read Holding Registers 04 (0x04) Read Input Registers 06 (0x06) Write Single Register 16 (0x10) Write Multiple registers (Limitation: Max. 120 registers within one message) Technical data Power supply Operating voltage G..B161.1E/MO AC 24 V ± 20 % (SELV) or AC 24 V class 2 (US) Frequency Power consumption Actuator holds Actuator rotates at 50 Hz GEB161.1E/MO GIB161.1E/MO GEB161.1E/MO GIB161.1E/MO 50/60 Hz 1.5 W 1.1 W 6 VA / 5.5 W 8 VA / 8 W Function data Running time for rotary angle 90 (motor operation) G..B161.1E/MO 150 s Nominal torque GEB.. 15 Nm GIB.. 35 Nm Maximum torque GEB.. 30 Nm Nominal / maximum rotation angle GIB.. 75 Nm 90 / 95 ± 2 Direction of rotation Adjustable over bus Clockwise (CW) / Counter-clockwise (CCW) Communication Communication protocol Modbus RTU RS-485, not galvanically separated Number of nodes Max. 32 Address range 1...247 / 255 Transmission formats Default: 255 1-8-E-1 / 1-8-O-1 / 1-8-N-1 / 1-8-N-2 Default: 1-8-E-1 Baudrates (kbaud) Auto / 9.6 / 19.2 / 38.4 / 57.6 / 76.8 / 115.2 Termination Default: Auto 120 Ω electronically switchable Default: Off Connection cables Cable length Power supply / Communication 0.9 m Number of cores and cross-sectional area 5 x 0.75 mm 2 9 / 14 2017-02-17 Building Technologies

Degree of protection Degree of protection Degree of protection acc. to EN 60529 (see also chapter Mounting above) Safety class Safety class acc. to EN 60730 III Environmental conditions Applicable standard IP54 IEC 60721-3-x Operation Climatic conditions Class 3K5 Mounting location Indoors Temperature general -32 55 C Humidity (non condensing) < 95 % r. h. Transport Climatic conditions Class 2K2 Temperature -32 70 C Humidity < 95 % r. h. Storage Climatic conditions Class 1K3 Directives and Standards Product standard Electromagnetic compatibility (Application) Temperature -5 45 C Humidity < 95 % r. h. EN60730-x For residential, commercial and industrial environments GEB161.1E/MO GIB161.1E/MO EU Conformity (CE) A5W00004376 1) A5W00004368 1) RCM Conformity A5W00004377 1) A5W00004369 1) EAC Conformity UL, cul Environmental compatibility Dimensions / Weight Eurasia conformity for all G..B variants UL 873 http://ul.com/database The product environmental declarations CE1E4621en 1), CE1E4626en 1) and A6V101083254en 1) contain data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Weight (w/o packaging) GEB.. 1.2 kg Dimensions (w/o bus interface) GIB.. GEB.. GIB.. 2.2 kg 81 x 192 x 63 mm 100 x 300 x 67.5 mm Suitable drive shafts GEB.. (round / square shaft) 6.4 20.5 mm / 6.4...13 mm GIB.. (round / square shaft) Min. drive shaft length 1) The documents can be downloaded from http://siemens.com/bt/download 8.0 25.6 mm / 6.0...18 mm 20 mm 10 / 14 Building Technologies 2017-02-17

Diagrams Internal diagrams The damper actuators are supplied with a prewired connecting and communication cable. All interconnected devices must be connected to the same G0. Core desig. Core color Terminal code Description 1 red (RD) G System voltage AC 24 V 2 black (BK) G0 System neutral AC 24 V 6 violet (VT) REF Reference (Modbus RTU) 8 grey (GY) + Bus + (Modbus RTU) 9 pink (PK) - Bus - (Modbus RTU) Note The operating voltage at terminals G and G0 must comply with the requirements under SELV or PELV. Safety transformers with twofold insulation as per EN 61558 required; they must be designed to be on 100 % of the time. 11 / 14 2017-02-17 Building Technologies

Dimensions GEB.. 141 42 10.6 20 113 GEB...1 Dia.5 Dia. 6.4...20.5 Square 6.4...13 60 81 31.5 Dia.10.5 168 180 19 192 60 Taptite M6 x 16 12 2 Mounting bracket 15 3 30 4621M01en 30 GIB.. 300 197 73 P1...P3 1...9 S1...S6 900 85,8 61,5 Ø 8... 25,6 mm ν 6... 18 mm 27,6 24,8 max.17,5 Taptite M6 x 16 max. 95 100 min. 100 67.5 210 150 4x8,5 71 min. 7 230 2 16 35,4 6x ø4,4 ø13 min. 60 min. 200 4626M03 3 35,4 4x ø5 20 15,5 External Modbus Interface A6V101006034M01 X = 220 mm Dimensions in mm 12 / 14 Building Technologies 2017-02-17

13 / 14 2017-02-17 Building Technologies

Issued by Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Switzerland Ltd, 2016 Technical specifications and availability subject to change without notice. Dokument-ID Ausgabe 2017-02-17