FREQUENCY CONVERTER FC101 (QUICK GUIDE)

Similar documents
FREQUENCY CONVERTER FC102 (QUICK GUIDE)

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

User Guide VLT Parallel Drive Modules

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Operating Instructions Extended Cascade Controller MCO 101

1 Extended and Advanced Cascade Controller Option 3

MAKING MODERN LIVING POSSIBLE. Quick Guide. VLT HVAC Basic Drive Cascade Control *MG18F102*

Vacon HVAC100 Commissioning Guide

MAKING MODERN LIVING POSSIBLE. Quick Guide VLT HVAC Basic Drive

AF-60 LP TM Micro Drive. Programming Guide

MAKING MODERN LIVING POSSIBLE. VLT AQUA Drive Cascade Controller Options MCO 101/102 Operating Instructions

AF-600 FP TM Fan & Pump Drive. (230V to 60HP, 460/575V to 125HP Operating Instructions

Taco System Logic (TSL)

P216. Condenser fan speed controller. Product bulletin. Features

MAKING MODERN LIVING POSSIBLE. Instruction VLT HVAC Basic Drive Cascade Controller

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Installation Instructions

Control system for rotary heat exchanger EQRB, L=3,4

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

P216 Series Condenser Fan Speed Controller

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

Operating Instructions

SMVector Additional I/O Module Installation and Operation Manual

Installation and Wiring Instructions... 9

Genset control and protection with safety system

Operating Instructions

TR150 DRIVE STANDARD FEATURES

OPERATING INSTRUCTION

EQ5 SERIES Quick Start Guide for Constant Torque Applications

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

NICOTRA Gebhardt EKE E-IM EKE E-IM S. Operating manual EC-Controller BA-EKE /2012

I/O module (Expansion module)

TPE, TPED Series 2000

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Standard Cascade Controller Setup... 38

RXTP ROOM TEMPERATURE

WARNING ELECTRICAL SHOCK HAZARD

SMVector Additional I/O Module Installation and Operation Manual

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Control D. Controller Module for Proportional Valve Control. Installation Manual

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Autoranging True RMS Multimeter User Manual

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Voltsys Inverter Control Unit

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Modbus RTU Option Card for VLT 5000/6000 Adjustable Frequency Drive

RXTH DUAL ROOM SENSOR / SWITCH

Genset Controller Unit Model EMS - GC10. Installation Manual Section

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

Installation Guide VLT Programmable I/O MCB 115

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

AF-60 LP TM Micro Drive

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Tachometer Panel, PE3

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

Q9 ASD LOW VOLTAGE DRIVE

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

INGERSOLL RAND Fixed Speed/Variable Speed Conversion COMMISSIONING AND OPERATION MANUAL

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

DC / AC True RMS Watt Clamp DMM

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

Compressor Controller MAM 890

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Peristaltic Cased Tube Pump

Altivar 21 Programming and Operation Guide

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Instruction Manual. Modbus RTU VLT 5000 VLT 6000 HVAC

Optidrive Applications Support Library

User Guide. IP20 & IP66 (NEMA 4X) AC Variable Speed Drive. Installation and Operating Instructions. 1 Quick Start Up kW (0.

Installation, Operation and Maintenance Manual

Communicative controller for VAV systems

Optidrive VTC Modbus RTU Register Map

1. Safety Danger Warnings Earthing and earth fault protection... 4

CURRENT PROTECTION RELAY SMPR-1

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

300XAC. Quick Start Guide. Modular AC Power Source MODELS 310XAC, 320XAC, 340XAC, 360XAC

DeviceNet Drive Profile CFW-09

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

Instruc on Manual. Series S3. Industrial Inverter IP20 IP66

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

VLT Micro Drive. Ready Set Go!

Voltsys Inverter Control Unit

VLT 8000 AQUA. Installation. Mechanical installation

AC Variable Speed Drive

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Supplementary operating instructions for your air curtain system Controller TMC 500

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

Transcription:

FREQUENCY CONVERTER FC101 (QUICK GUIDE) INSTALLATION AND MAINTENANCE Content Page Safety instructions 2 IT system 3x230VAC 2 Connections 3 Control unit (LCP) 4 Manual operation 4 Reverse the direction of rotation 4 More information 4 Wiring diagram 5 Basic configuration 6 PID regulation 7

2 Installation and maintenance SAFETY INSTRUCTIONS Check that the frequency converter is correctly connected to earth. Do not pull out the mains or motor contacts or other power connections when the frequency converter is connected to the power supply grid. Protect the user from mains voltage. Protect the motor against overload in accordance with national and local regulations. The leakage currents to earth exceed 3.5 ma, see the Design guide on the enclosed CD. The [Off/Reset] button is not an isolator switch. It does not disconnect the frequency converter from the mains. WARNING! Warning high voltage The frequency converter is subject to highly dangerous voltages when it is connected to the mains. Incorrect installation of the motor or frequency converter can lead to material damage, serious personal injury or death. Follow the instructions in this manual as well as local and national provisions and safety regulations. Voltage (V) WARNING! Discharge time! Frequency converters have DC bus capacitors that can hold a charge even after the mains voltage has been disconnected. Prevent electrical hazards by disconnecting the mains voltage, disconnecting permanent magnet motors and DC bus supplies, including battery backup, UPS and DC bus connections for other frequency converters. Wait until the capacitors have fully discharged before carrying out maintenance or repairs. Read more about the discharge waiting times in the table below. Starting to service or repair the unit immediately after cutting the power supply, without waiting for the specified period, can lead to death or serious personal injury. Output range (kw) Minimum waiting time (min) 3 x 200 0,25 3.7 4 3 x 200 5.5 45 15 3 x 400 0,37 7.5 4 3 x 400 11 90 15 WARNING! Installation at heights For installation at height, contact FläktGroup regarding PELV. TAKE CARE! Residual current device: This product can cause a direct current in the protective earth conductor. When using a residual current device as additional protection, use only a type B residual current device (delayed) on the input side of this product. See also Danfoss application note for the MN90G RCD. The protective earthing of the frequency converter and the use of RCDs must always follow national and local regulations. TAKE CARE! IT system (3x230VAC) When installing the FC101 on an isolated system (IT system, 3x230VAC) set parameter 14-50 to [0] Off. Press [Main Menu] twice. Navigate using the [ ] [ ] and [OK] buttons until parameter 14 50 is displayed (select 14 **, then 14 5* and lastly 14 50). Set this parameter to [0] Off.

Installation and maintenance 3 For 0.25 11kW the RFI switch must be opened by removing the screw (1) on the side of the frequency converter before energising it. See figure beside. CONNECTIONS DIAGRAM 1 2 3 8 1 RS 485 2 Supply 3 Protective earth 4 Cable clamps 5 Motor 6 UDC (not in use) 7 7 Relay outputs 8 I/O 6 5 4

4 Installation and maintenance CONTROL UNIT (LCP) A. Alphanumeric display 1. Parameter number and name. 2. Parameter value 3. Menu number 4. Direction of rotation of the motor 5. Triangle labelling of the status menu, quick menu or main menu. 1 2 3 4 6 A B Com. 1-20 Motor Power [5] 0.37kW - 0.5HP Setup 1 Menu Status Quick Menu Main Menu 130BB765.11 5 B. Menu buttons Menu button for selecting the status menu, quick menu or main menu. C. Navigation and indication 6. LED Com: Data traffic over the bus 7. LED On (green): Control unit in operation 8. LED Warn. (yellow): Warning indication. 9. LED Alarm (red): Alarm indication. 10. [Back]: Returns to the previous step or level [ ] [ ] [ ]: Navigation between parameters and for changing parameters or local references. 12. [OK]: Selecting parameters and saving set values 10 7 8 9 C D On Warn. Alarm Hand On Back OK Off Reset Auto On 13 14 15 11 11 12 11 11 D. Control buttons with LEDs 13. [Hand/On]: Starting the motor for local control using the control unit 14. [Off/Reset]: Stopping the motor and resetting alarms. 15. [Auto/On]: Allow control via control terminals or the communication bus MANUAL OPERATION Press [Hand/ON] to start Press [ ] [ ] to set the speed Press [OFF/Reset] to stop Press [Auto/ON] to return to automatic operation REVERSE THE DIRECTION OF ROTATION If necessary the direction of rotation can be reversed using parameter 1-06. When connection is correct 0 = clockwise and 1 = anti-clockwise. MORE INFORMATION This quick guide contains the basic information needed to install and operate the frequency converter. There is more information available on the enclosed CD.

Installation and maintenance 5 WIRING DIAGRAM L1 L2 L3 N PE F1 91 92 93 95 L1 L2 L3 PE U V W PE 96 97 98 99 Danfoss FC101 +24V 12 +24V 13 DIG IN 18 DIG IN 19 COM 20 DIG IN 27 DIG IN 29 DIG IN 32 DIG IN 33 DIG IN 37 +10V 50 A IN 53 A IN 54 COM 55 A OUT 42 COM 39 R2 R1 01 02 03 04 05 06 RS-485 com 61 RS-485 + 68 RS-485-69 + - + - Relay output 0 Alarm NO/NC (Param. 5-40.0) Relay output 1 Start Start Reference 0 10VDC (FW standard) Actual value PID regulation Run Indicator NO/NC (Param. 5-40.1) M The basic configuration (FläktGroup standard) relates to 0...10 VDC control via terminal block 53. To activate the internal PID regulator see page 6. The sensor is connected to terminal block 54. SIGNALS Designation Type Terminal block Start Potential-free closure 12-18 Control signal 0...10VDC 53 Pressure/flow sensor 0...10VDC (4...20mA) 54 COM For analogue in (Terminal blocks 53, 54) 55 Alarm R1 NO/NC 01, 02, 03 Operation R2 NO/NC 04, 05, 06

6 Installation and maintenance BASIC CONFIGURATION FOR ASYNCHRONOUS MACHINES (FLÄKTGROUP STANDARD) When the frequency converter is energized for the first time the language can be selected. Obviously this can be changed later. After the configuration guide (FC101 Wizard) is started for 0...10VDC control by pressing [OK] again. If you intend instead to use the internal PID regulator, press [Back] and continue to the next page in the quick guide. Step Parameter Description TF FF 6-15** T53 High Ref./Feedb. Value Same as 3-03 Same as 3-03 1 0-01 Language English English 2 0-03 Regional settings International International 3 0-06 GridType 200-240 V/50 Hz/IT-grid 380-440 V/50 Hz 4 1-10 Motor construction Asynchron Asynchron See order 5 1-20 Motor Power [kw] 6 1-22 Motor Voltage [V] 7 1-23 Motor frequency [Hz] 8 1-24 Motor current [A] See motor plate 9 1-25 Motor nominal speed [rpm] 10 1-42 Motor cable length 50m 50m 11 4-12 Motor speed low limit 0 Hz 0 Hz 12 4-14**) Motor speed high limit Same as 3-03 Same as 3-03 13 3-41 Ramp 1 ramp-up time 14 3-42 Ramp 1 ramp-down time 15 1-73 Flying start Enable Enable 30s 40s 16 6-19 T53 Mode Voltage Voltage 17 6-10 T53 Low voltage 0.07 V 0.07 V 18 6-11 T53 High voltage 10 V 10 V 19 3-02 Min reference 0 Hz 0 Hz 20 3-03 Max reference Hz Hz 21 5-40.0 Function of relay 1 Alarm Alarm 22 5-40.1 Function of relay 2 Drive running Drive running do not change do not change 23 1-29 Automatic motor adaptation Enable Enable Complete Complete AMA AMA **) If the Motor speed high limit is to be set higher than 50 Hz then 6-15 must first be changed to the same value from the Main menu. If the Motor speed high limit is to be set higher than 100 Hz then 4-19 and 6-15 must first be changed to the same value from the Main menu. When using CentriFlow 3D, you need to enter 1-06 and change the direction of rotation to [1] inverse. Configuration carried out by Date The configuration guide can be reactivated at any time. Press [Menu] until the indicator in the display points to Quick menu. Start the configuration guide (FC101 Wizard) by pressing [OK]. Danfoss factory reset Press [Menu] until the arrow points to Main menu. Navigate using the [ ] [ ] buttons and [OK] until the 14-22 parameter is displayed (select 14-**, then 14-2* and lastly 14-22). Set this parameter to 2 and then switch off the mains voltage. When the frequency converter is re-energised the parameters will have returned to their factory settings and alarm 080 is generated. Press [Off/Reset] to acknowledge this.

Installation and maintenance 7 PID REGULATION OF ASYNCHRONOUS MACHINES To configure the frequency converter for operation using the internal PID regulator press [Menu] until the indicator in the display points to Quick menu. Press the [ ] [ ] buttons to select Close loop setup. Then start the configuration guide for PID regulation by pressing [OK]. Step Parameter Description TF FF 1 0-03 Regional settings International International 2 0-06 GridType 200-240 V/50 Hz/IT-grid 380-440 V/50 Hz 3 1-00 Configuration mode Closed loop Closed loop 4 1-10 Motor construction Asynchron Asynchron 5 1-20 Motor Power [kw] 6 1-22 Motor Voltage [V] 7 1-23 Motor frequency [Hz] See motor plate 8 1-24 Motor current [A] 9 1-25 Motor nominal speed [rpm] 10 4-12 Motor speed low limit 0 Hz 0 Hz 11 4-14**) Motor speed high limit Hz Hz 12 3-41 Ramp 1 ramp-up time 13 3-42 Ramp 1 ramp-down time 30s 40s 14 1-73 Flying start Enable Enable 15 3-02 Min reference 0 % 0 % 16 3-03 Max reference % % 17 3-10 Preset reference % % 18 6-29 Terminal 54 mode (Voltage/Current) 19 6-20(6-22)* T54 low voltage [V] (Current [A])* 0.07V/4mA 0.07 V/4mA Setpoint See sensor 20 6-24 T54 low feedback [%] 0 % 0 % 21 6-21(6-23)* T54 high voltage [V] (Current [A])* 10V/20mA 10V/20mA 22 6-25 T54 high feedback [%] 100 % 100 % 23 6-26 T54 Filter time constant 1 s 1 s 24 20-81 PI Normal/Inverse control Normal Normal 25 20-83 PI Start speed [Hz] 0 Hz 0 Hz 26 20-93 PI Proportional gain 1.5 1.5 27 20-94 PI Integration time [s] 30 s 30 s Adjust if necessary 28 1-29 Automatic motor adaptation Enable Enable complete complete *) The parameter in question in the Quick menu depends on the function selected using the parameter 6 29. **) If the Motor speed high limit is to be set higher than 50 Hz then 3-03 and 6-15 must first be changed to the same value from the Main menu. If the Motor speed high limit is to be set higher than 65 Hz then 4-19, 3-03 and 6-15 must first be changed to the same value from the Main menu. AMA AMA Configuration carried out by Date

8 Installation and maintenance MODBUS RTU IN EQ If Modbus RTU is used in eq AHU for controlling drives, they must be set according to the table below. Configuration Parameter Description Value 8-30 Protocol [2] Modbus RTU 8-31 Address Supply fan: 60 Exhaust fan: 70 8-32 Baudrate [2] 9600 8-33 Parity / Stop bits [2] No parity, 1 Stop bit PARALLEL OPERATION When two frequency converters are to operate in parallel, one must be configured as master and the other as slave. After this, connect the two frequency converters together as indicated below. Configuration, master Parameter Description TF FF 6-70 Signal terminal block 45 4-20mA 4-20mA 6-71 Function, terminal block 45 Reference Reference Configuration, slave Parameter Description TF FF 6-19 Selection of reference signal ma ma 6-14 Output frequency equivalent to 4mA 0 Hz 0 Hz 6-15 Output frequency equivalent to 20mA Hz Hz Connection Master Slave 45 53 55 55