Relay setting toolbox

Similar documents
Relay configuration and setting tool package

Relay Product Engineering Tools

CAP 505 Relay Product Engineering Tools Installation and Commissioning Guide

Communicate IT Software module DR-COM. Buyer s Guide

Power Products. Protection and Control IED Manager PCM600 Product Guide

REM 543 Machine Terminal. User s Guide for Modbus Configurations

Terminal tool box CAP 540*1.2

MV Process Application Library LIB 510. Product Guide

CAP 505. User s Guide

Communication Gateway COM 500. Product Guide

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

Protection and Control IED Manager PCM600 Product Guide

Communication Gateway COM 610. Product Guide

Protection and Control IED Manager PCM600 Product Guide

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

User s Manual CAP 531*1.5 Configuration and Programming tool

Connectivity Packages. User's Guide - ANSI Version

Earth-fault Relay SPAJ 110 C. Product Guide

XEROX. CopyCentre / WorkCentre Pro Auditron Report Software. User Manual

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

PSM 505. Inform IT Power System Monitoring. Stand-alone Fault Analysis and Evaluation Tool. Technical Data. Introduction.

Quick Start Guide PCM600 for Relion 650/670 Series

Relay Setting Tools CAP 501 Operator s Manual

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles

High impedance protection relay

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Data communication and reporting unit

General characteristics of C-type relay modules

Feeder protection relay SPAA 121 C. Product Guide

Modbus Remote Communication Protocol for REM 54_. Technical Description

Residual overvoltage relay

RER 123 Bus Connection Module. Technical Description

Unocode 399 * * * * The very best in code cutting or copying. Machine built to CE (European Community) safety standards.

Data communication and reporting unit

Synchro-check relay. Application

Installation and Operating Instructions

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

SM/SACO for SMS 010 User s Guide SMS 010 SACO library

DPT - EN1 R1 Users Manual

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

Substation automation products. MicroSCADA Pro for substation automation

PHARO User Configuration Software UCS USER MANUAL Rev.0-15/07/ pharo.reer.it

Sage BusinessWorks v8.0 System Standards

INSTALLATION AND USER GUIDE

SREDU Double Connection Option Card for Lon Star Coupler RER 111

Grid Automation Controller COM600 How it fits into the Smart Grid?

SYS 500 Installation 1MRS MEN. Notice 1. Notice 2. Notice 3. Trademarks

This chapter explains about the SmartOperator, the CTI system supported by the DCS Gateway system.

Trace Debug Tools Version 1.2 Installation Guide

Installing MachineShop... 2

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Control Solutions MICRO-DCI COMMUNICATION SERVICES

NDA ISSUE 1 STOCK # MATWorX 32 User s Guide. December, NEC America, Inc.

MicroSCADA Pro DMS 600 *4.1 System Overview. Technical Description

COM600 Station Automation Series MNS is Connectivity (OPC) 3.2. User's Guide

Protection System Simulator SIM600. Installation Manual

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference.

Arc protection relay. Features Three-phase overcurrent function. Application

Perle 594M Getting Started

Operating Instructions

Arc protection relay. Features Three-phase overcurrent function. Application

REX 521 Protection Relay Operator s Manual

PCM-9342 EVA-X SBC with PC/104, VGA/ TTL/LVDS Ethernet/USB 2.0 and SSD Startup Manual

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

Enterprise Guide Version 2.0 for Windows

LABEL MATRIX TEKLYNX VERSION 8 I N S T A L L A T I O N

VM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES

EbixONE Microsoft Solution System, Network, and Software Requirements

ArcInfo Desktop 8.3 System Requirements

Sentinel UltraPro Version (Windows) Release Notes

FX Tools Express Software Package

EP1000 A E-Port Communications Gateway

DAQ-System for DynoWare

Standard System Specifications

SiloTrack V3.0. Inventory Management Software. Server & Client Software Demonstration Guideline.

Power Products. Station Automation COM600 Product Guide

StoneGate Management Center Release Notes for Version 4.2.1

ArbExpress AXW100 Waveform Creation and Editing Tool for Tektronix AWG/AFG Installation Manual

General Specifications

DocSTAR v3.3 Software Installation Guide Page 1

Sage BusinessWorks Accounting 2012 System Standards

Operating Instructions

DEFINITY IP Softphone Release 1 Getting Started

IBM ViaVoice for Windows, Release 8 Family of Products, Spanish Language Version, Delivers Improved ViaVoice Performance

2006 Sony Corporation Printed in China (1) Quick Start Guide NW-E002F / E003F / E005F / E002 / E003 / E005

Feeder protection relay

Solution Developer Marketing: AS/400 Introduction CBT Self-Study Courseware from Course Technology, Inc.

REVISIONS * The manual number is given on the bottom left of the back cover.

MCS Workstation Software Installation Guide

Joint Fleet Maintenance Manual

LNT 505 Installation and Commissioning Manual

IBM Workstation APL2 for Multiplatforms V2 Includes Productivity Enhancements and Linux Support

INDeX Technical Update

ArcReader 8.3 System Requirements

Relion 611 series. 611 series Type Test Certificate

ABB ABB Oy, Distribution Automation

Transcription:

Relay setting toolbox CAP 501 Issued: May 1999 Status: Updated Version B/06.11.2001 Data subject to change without notice Features General parameter setting support for ABB protection relays and terminales range of products for distribution applications User friendly tool management Parameter file upload/download and compare function Parameter file printing support Manually initiated uploading of disturbance recorder data Versatile integration of disturbance data evaluation tools of your choice Easy switching between verified setting groups or setting banks Reset of protection relay Presents relay indications, measurement, calculated values and registered values. Direct cable connection to a protection relay or a terminal using SPA communication protocol Flexible tree-structure navigator Excellent commissioning tool Easy to upgrade to support new functions and products All tools and documentation provided on one CD Application The CAP 501 Relay Setting Tool Package is aimed for commissioning, maintenance, service and monitoring of the process and its secondary equipment in distribution substations. The package includes following tool functions: Parameter setting and archiving Compare between parameter settings in the relay and the archive Upload and download of paramer setting files Printing of parameter setting files Edit history of parameters Protection relay setting bank switching Reset of protection trip function Upload of disturbance recorder files Upload of registered, measured and calculated values Multi layered tree structure navigator As the tools in CAP 501 are fully consistent with CAP505 stand-alone tool packages, SMS 510 substation monitoring system and the LIB500 application libraries, work generated by CAP 501 can easily be reused in a larger SMS system or in a full-fledged SA system. The range of protection and control terminals with SPA communication supported in CAP 501 Revision 2.1.1: The entire SPACOM range including SACO annunciators The Multipurpose Relay Series REJ/REU 5 The REF 541/543/545 Integrated Protection and Control Terminals The REM 543/545 Integrated Machine Protection and Control Terminals The The REX 521 Integrated Protection and Control Terminal The REC 501/523 Control Terminals 1

Relay setting toolbox CAP 501 Further information about CAP 501 and its application in single relay applications and in local and remote system solutions can be found in the full product documentation on the product CD-ROM. Design Categorization of the software parts The CAP 501 product consists of a base system with a navigator on which support tools for the protection and control terminals are run Base System Kernel software, navigator, communication configuration, additional base tools and services are providing a framework for the object types and tools. Fig. 1 CAP 501 Navigation window Fig. 3 Recorder tool window Relay setting tool Including all functions belonging to parameter, register- and input values and reset functions. The package include one tool for SPACOM products and one tool for all other terminals. Fig. 4 DR tool window Fig. 2 Relay setting tool REMMI Disturbance recorder tool Includes the functionality corresponding to upload of disturbance recordings. Separate disturbance evaluation tools which can be started from the CAP 501 package are available from ABB. System configuration The tool package is delivered on a CD which can be installed on a PC with Win NT operating system. The Win 2000 support is sheduled to Q4 2001. The PC communicates to the protection relay or terminal using the SPA protocol via a product specific cable connected between the PC,s COM port and the communication interface of the relay. The communication is always point to point. 2

Relay setting toolbox CAP 501 A separate cable package 1MRS 15100 is available including following cables: 5HOD\ &DEOH 7\SH REF 541/543/545 REM 543/545 REC 523 REX 521 1MKC950001 SPTO front connection SPA-ZP 17A3 RS 232 - RS 232 SPCR front connection SPACOM 100/300 series SPA-ZP 5A3 RS 232 - TTL connector SACO except SACO 148D4 SPAC 300/500/600 rear SPA-ZP 6A2 RS 232 - RS 485 connection SACO except for SACO 148D4 SPA-ZP 21A Connection cable for SPA-ZP 6A2 to screw terminal Opto Document files CAP 501 documentation in PDF format and an installer for installing the Acrobat Reader from Adobe Corporation are included on the CD. The Acrobat Reader is needed to view the documentation 3

Relay setting toolbox CAP 501 Technical data CAP 501 v.2.1.1 sets the following hardware and software requirements for the PC: 6RIWZDUHUHTXLUHPHQWV Operating system Network Microsoft(r)1 Windows NT(r)2 4.0 Workstation or higher. On Windows NT 4.0, it is highly recommended to have the Service Pack 5 installed. Operating system network software installed with at least one network protocol (e.g. TCP/IP) +DUGZDUHUHTXLUHPHQWV,WHP 0LQLPXP 5HFRPPHQGHG Processor Pentium 3 133 MHz Pentium II 200 MHz Memory 64 MB 128 MB Display SVGA, 800x600, 256 colours SVGA, 1024x768, 256 colours File system NTFS file system on the installation drive Hard disk space 150 MB 250 MB Serial ports Two COM ports Parallel ports Optionally one parallel port for printing purposes CD-ROM drive Any device supported by the operating system. Required for installation Mouse Any device supported by the operating system Network adapter card Any device supported by the operating system Ordering The following alternatives are available: CAP 501 version v.2.1.1. tool package CD-ROM is delivered free of charge with a protection relay or terminal when requested. If ordered separately, an order handling fee will be charged. Ordering number: 1MRS151019 A set of communication cables for all supported protection relays and terminals is available. Odering number: 1MRS151000 Microsoft is a registered trademark of Microsoft Corporation. Windows NT is a trademark of Microsoft Corporation. Intel and Pentium are registered trademarks of Intel Corporation. IBM and AT are registered trademarks of International Business Machines Corporation. All other product names are trademarks, registered trademarks, or service marks of their respective owners. 4

ABB Oy P.O. Box 699 FIN-65101 Vaasa, Finland Tel +358 10 224 000 Fax +358 10 224 1094 www.abb.com/substationautomation