Testing for SLA Compliance of business services over DOCSIS 3.1

Similar documents
The Essentials of Ethernet Service Activation

The Essentials of Ethernet Service Activation

Viavi Solutions Ethernet Testing

CAN EMTC IOT BE SUPPORTED OVER THE HFC NETWORK

Developing Standards for Metro Ethernet Networks

Performance Assurance Solution Components

Technical Specification MEF 27. Abstract Test Suite For. May 20 th, 2010

Hands-On Metro Ethernet Carrier Class Networks

Metro Ethernet Design and Engineering for CO

Technical Specification MEF 6. Ethernet Services Definitions - Phase I. June 2004

SD-WAN AND BEYOND: DELIVERING VIRTUAL NETWORK SERVICES

ecpri Transport Network V1.0 ( )

The Essentials of Ethernet Service Activation

NetAnalyst Test Management Software Automated, Centralized Network Testing. NetComplete Service Assurance Solutions Portfolio

DOCSIS FOR LTE SMALL CELL BACKHAUL ADDRESSING PERFORMANCE AND THROUGHPUT REQUIREMENTS FOR MOBILE BACKHAUL

Service Definition Internet Service

Carrier Ethernet Installation. the Path to Excellence

Technical Specification MEF 10. Ethernet Services Attributes Phase 1. (Obsoletes MEF 1 and MEF 5) November 2004

Layer 2 Performance Measurement and Reporting Regime

Arthur Moll BDM. Transport and Datacom. May Introducing EtherSAM. Ethernet Service Activation Methodology

Final draft ETSI EN V1.1.0 ( )

DragonWave, Horizon and Avenue are registered trademarks of DragonWave Inc DragonWave Inc. All rights reserved

Technical Specification MEF 14. Abstract Test Suite for Traffic Management Phase 1. November, 2005

ISCOM RAX 711 (B) Ethernet Demarcation Device

L2CONNECT 2.0 E-ACCESS

JULY 2016 ISCMAG.COM VOLUME 34, ISSUE 7

Virtualizing Managed Business Services for SoHo/SME Leveraging SDN/NFV and vcpe

DATA SHEETS. Unpublished. Datasheet: OneTouch AT 10G Network Assistant Performance Testing

Examining the Practicality of Ethernet for Mobile Backhaul Through Interoperability Testing

Evolving Telecommunications to Triple Play:

Ethernet based Broadband Access Networks

Ericsson ip transport nms

MPX100 Intelligent Ethernet Test Probe

Central Office Testing of Network Services

ISCOM2948GF-4C Intelligent Ethernet Service Aggregation

ACCEDIAN NETWORKS. White Paper & Case Study ROI & Benefits from NID-enabled Ethernet Services. ROI & Benefit Highlights

IP SLA Service Performance Testing

Mobile Backhaul Business Class Ethernet Wave Division Multiplexing Aggregation Switching SERVICE PROVIDER

The functions, goals and benefits of 802.3ah OAM Ethernet Fiber Access with Network Interface Devices

Metro Ethernet Services A Technical Overview Ralph Santitoro

Broadband and Last Mile Networks

RAX711-L Multi-service Network Terminal

NETWORK SERVICES: ETHERNET WAN ETHERNET SERVICES PRODUCT PORTFOLIO SUMMARY DOCUMENT

MOVING BEYOND THE STANDARD: CREATING ADDITIONAL BANDWIDTH THROUGH EXTENDING DOCSIS 2.0. Jack Moran, Distinguished Member of the Technical Staff

MEF-CECP Certification Exam Blueprint "D"

WHITE PAPER. Latency & Jitter WHITE PAPER OVERVIEW

FLASHWAVE 5320 Ethernet Services Platform

NS-090. Carrier Ethernet Based on MPLS-TP SERIES NS: NEW TECHNOLOGIES. PTCL Specifications NS-090 PAKISTAN TELECOMMUNICATION COMPANY LIMITED

The Micro Packet ONP: Leveraging Today s Optical Network For Next-Generation Ethernet Access

L2VPN Support on Cable

Broadband Data, Video, Voice and Mobile Convergence Extending the Triple Play. Yigal Bitran, Chief Technology Officer

Service description ETHERNET

Deploying IPTV and OTT

IP SLA Service Performance Testing

MetroEthernet Options

Computer Networks and the internet. Daniel Graham Ph.D

INDOOR SMALL CELLS: AGGREGATION AND BACKHAUL ENHANCE QUALITY OF EXPERIENCE AND STREAMLINE OPERATIONS

LIGHTS! Broadband Basics

Testing Carrier Ethernet SLA s. Mark Mullins Carrier Ethernet Marketing Manager

Alcatel-Lucent 1850 TSS Product Family. Seamlessly migrate from SDH/SONET to packet

WHEN RF AND IP CLASH THE REALM OF DOCSIS & VOIP TROUBLESHOOTING BY BRADY VOLPE, THE VOLPE FIRM FORMALLY OF SUNRISE TELECOM

Cisco ASR 1000 Series Aggregation Services Routers: QoS Architecture and Solutions

Secure PTP - Protecting PTP with MACsec without losing accuracy. ITSF 2014 Thomas Joergensen Vitesse Semiconductor

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

Universal Network Demarcation. Enabling Ethernet and wave services with the Nokia 1830 PSD. Application note. 1 Application note

Hardware Description

DPoE in MSO Network. SCTE Piedmont Chapter. Presented by Jorge Figueroa Sr. Systems Engineer

CONNECTICUT ACCESS SERVICE TARIFF. The Southern New England Original Page 23-1 Telephone Company d/b/a Frontier Communications of Connecticut

Chapter 1: introduction

esam - Performance Assessment

IP Core Expertise From WireIE

Alcatel-Lucent 9500 Microwave Packet Radio (ETSI Markets)

MOTOROLA EXPEDIENCE TECHNICAL OVERVIEW

Product Overview. EchoVault SLA EMS SLA Creation & Management System

Header Compression Capacity Calculations for Wireless Networks

Enable Networks UFB Services Agreement Bitstream Services: Service Description for Multicast Service

Cable s Role in the 5G Evolution

END-TO-END SERVICE OAM. Carrier Ethernet White Paper

Service Definition E-Line Service

TECHNICAL REPORT. CPE Architecture Recommendations for Access to Legacy Data Networks. DSL Forum TR-032. May 2000

end systems, access networks, links 1.3 network core

Making metro Ethernet services carrier class. A White Paper from Telco Systems

EZ ETHERNET A SIMPLE, EASY-TO-CONNECT ALTERNATIVE FOR LOW-BANDWIDTH ETHERNET ACCESS

Schedule to Data Products Service Appendix Service Level Agreement

Performance Management Reporting User Guide for EPMR

Technical Specification MEF 1. Ethernet Services Model, Phase November 2003

Multi-Dimensional Service Aware Management for End-to-End Carrier Ethernet Services By Peter Chahal

XGT G Ethernet Tester

Metro Ethernet for Government Enhanced Connectivity Drives the Business Transformation of Government

Introduction to Quality of Service

BV-110 Verifier MULTIFUNCTIONAL CPE AND CELL SITE SERVICE ASSURANCE VERIFIER

Telecom Learning. Technology

HigH THrougHpuT MeeTs Low TCo. THe etherhaul TM wireless BaCkHauL. 4Gon Tel: +44 (0) Fax: +44 (0)

Configuring Quality of Service

5G: an IP Engineer Perspective

PTP650 Synchronous Ethernet and IEEE1588 Primer

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 2

Broadband Backhaul Asymmetric Wireless Transmission

CUSTOMER DATA FORMAT REQUIREMENTS

Product Technical Specification

Transcription:

Testing for SLA Compliance of business services over DOCSIS 3.1 A Technical Paper prepared for SCTE/ISBE by Robert J. Flask Sr. Product Line Manager Viavi Solutions 5808 Churchman Byp. Indianapolis, IN 46203 317-614-8125 robert.flask@viavisolutions.com 2017 SCTE-ISBE and NCTA. All rights reserved.

Title Table of Contents Page Number Introduction 4 Content 4 1. DOCSIS and Ethernet SLA Testing 4 1.1. Legacy DOCSIS 5 1.1.1. Best Effort Services SMB 5 1.2. Metro Ethernet service 6 1.2.1. Key Components of Ethernet service activation SLA testing 6 1.2.2. Ethernet KPI verification 6 1.2.3. What are the key tests 7 1.2.4. Operation Administration and Monitoring (OAM) 9 1.3. How DOCSIS 3.1 enables improved Ethernet services 9 1.3.1. DTP DOCSIS Timing Protocol 9 2. Best Practices for SLA testing 11 2.1. PTP/DTP timing 12 2.2. OWD measurements for Mobile Backhaul SLA s and Carrier Ethernet 13 2.3. Using automation with remote probe to speed up service activation 13 Conclusion 15 Abbreviations 15 Bibliography & References 16 List of Figures Title Page Number Figure 1 - Multiple EVC s over the DOCSIS network 4 Figure 2 - DOCSIS Network is Last Mile Portion of the Ethernet Service 5 Figure 3 - DTP Clock System 9 Figure 4 - DOCSIS System Works Like Boundary Clock 10 Figure 5 - DTP System Skew And Error Budgets 10 Figure 6 - Best practices for complete service activation 12 Figure 7 - OWD and 1588V2 testing connection using GPS source 12 Figure 8 - PTP/DTP One Way Delay Testing with External GPS reference 13 Figure 9 - Example of SLA Testing with Automation for Efficient Turn Up and Activation 14 List of Tables Title Page Number Table 1 - Example of typical local Metro Ethernet service requirements 6 Table 2 - Example of typical local Ethernet SLA over DOCSIS 3.0 6 2017 SCTE-ISBE and NCTA. All rights reserved. 2

Table 3 - Service Tests for validating Ethernet SLA s 8 Table 4 - DTP System Timing Error Budget (table 10-9 CM-SP-MULPIv3.1-I11-170510 11 2017 SCTE-ISBE and NCTA. All rights reserved. 3

Introduction Communications and data service growth is driving the demand for Ethernet services. Many Ethernet services, such as cellular backhaul have stringent Service Level Agreement (SLA) requirements. SLA requirements are verified at time of turn-up and can be monitored in the background. With the extensive reach and coverage of the Hybrid Fiber Coax (HFC) networks, cable operators are well positioned to utilize DOCSIS as a delivery method for Ethernet services. Legacy DOCSIS systems including DOCSIS 3.0 have limitations that prevent it from being used for timing critical Ethernet services. DOCSIS 3.1 has added additional mechanisms that if designed and implemented can provide capability to provide Ethernet services to stringent services such as Advanced LTE backhaul. Best practices for Ethernet service SLA compliance can be implemented that include turn up and automation to simplify the process. There are various testing standards used for validating business service SLA s including RFC-6349, RFC-2544, Y.1564, Y.1731. Many of these standards weren t very relevant with DOCSIS 3.0 but now are likely to become part of the repertoire of DOCSIS 3.1 Ethernet service deployments. Content 1. DOCSIS and Ethernet SLA Testing DOCSIS is by nature a shared environment. When providing Ethernet services over DOCSIS, only a portion of the DOCSIS network capacity is being utilized for the customer. The DOCSIS network can be viewed as the User Network Interface (UNI). Multiple customers will use the DOCSIS network simultaneously, including residential data services and voice service. Providing a dedicated Ethernet service to a business entails the creation of an Ethernet Virtual Circuit (EVC) that utilizes a portion of the overall UNI. The most typical way of supporting Business Services Over DOCSIS (BSOD) today is via Layer 2 VPN support. CableLabs specifies guidelines for operators to offer MEF compliant Layer 2 Transparent LAN services (TLS) to commercial enterprises. Note that the sum of all of the EVC s for guaranteed SLA service must be less than the overall UNI speed. This creates challenges for sharing a portion of a DOCSIS network with SLA business services and high capacity best-effort services. Figure 1 - Multiple EVC s over the DOCSIS network The DOCSIS network is only a portion of what the Ethernet service resides in. Rarely does a customer only need Ethernet service within the DOCSIS portion of the network. As shown in Figure 2 the DOCSIS portion is typically just the last mile. 2017 SCTE-ISBE and NCTA. All rights reserved. 4

Figure 2 - DOCSIS Network is Last Mile Portion of the Ethernet Service 1.1. Legacy DOCSIS Existing DOCSIS services up through DOCSIS 3.0 had capacity, architecture, and design limitations that limited the opportunities where DOCSIS could be effectively used for SLA based Ethernet business services. Asymmetric capacity limitations limited the speed of service that could be offered and performance metrics regarding latency (frame delay), and jitter (frame delay variation). The timing accuracy for DOCSIS 3.0 systems prevented the use of DOCSIS for cellular backhaul, LTE, and Advanced LTE. 1.1.1. Best Effort Services SMB DOCSIS fits well into the Small to Medium Business that mostly requires solid and consistent Internet services. Throughput tests with capability to validate best effort pipe speeds is critical to make sure impairments aren t impacting the capacity. Typically, operators will provision with about 10 % Excess Information Rate above the stated service level to ensure Speedtest throughputs meet or exceed the advertised upload/download speeds. But with best effort services there typically aren t any penalty clauses regarding speeds. More typically, the SLA s for best effort service surround availability and Mean Time To Repair (MTTR). 2017 SCTE-ISBE and NCTA. All rights reserved. 5

To ensure real life customer experience for a best effort service, RFC-6349 testing is recommended. This will identify the customers actual layer 4 TCP throughput and also identify any configuration or TCP efficiency issues. RFC 6349 testing can show the effects of traffic shaping that may be occurring. 1.2. Metro Ethernet service 1.2.1. Key Components of Ethernet service activation SLA testing Ethernet business services can vary from being a basic best effort internet service, like a traditional home cable modem, to a high-performance Ethernet service with guaranteed performance with SLA requirements for availability, MTTR, Latency/Frame Delay (FD), Jitter/Frame Delay Variation (FDV), Throughput (Committed Information Rate (CIR)/ Excess Information Rate (EIR), and frame loss. Ethernet business services typically require some level of SLA. A typical SLA for a local Metro Ethernet service is show in Table 1 for Ethernet services and standard mobile backhaul service. Frame Delay Table 1 - Example of typical local Metro Ethernet service requirements KPI Ethernet Services Mobile Backhaul services Frame Delay Variation < 2 ms Frame Loss 6.25 x 10-6 Throughput 99.99% Availability 99.995% Mean-time to repair typical 5 ms - best effort up to 30 ms 2 hours ( max 4 hours) < 8 ms typical 5 ms Comparatively, with legacy DOCSIS 3.0 the SLA levels are much relaxed. Particularly the Frame Delay and the Frame delay variation. Table 2 shows a typical example of an SLA over an existing DOCSIS 3.0 network. Note that the Frame Delay allowance is even higher than typical best effort Ethernet services. Table 2 - Example of typical local Ethernet SLA over DOCSIS 3.0 KPI Frame Delay <60ms Frame Delay Variation < 12 ms Frame Loss < 0.1% Throughput 95% Availability 99.9% Mean-time to repair 4 hours 1.2.2. Ethernet KPI verification DOCSIS Ethernet Services Validation of SLA requirements require testing and monitoring. Common practice is for initial testing via a field meter at install and service turn up. Often the field testing is combined with automated or centralized test through remote test heads or software agents to make a faster and more consistent test practice. 2017 SCTE-ISBE and NCTA. All rights reserved. 6

1.2.3. What are the key tests To verify and test to the SLA, various tests are used for Metro Ethernet services depending on the service type and SLA. Table 3 shows a list of common tests that are used for validating the varying SLA requirements. 2017 SCTE-ISBE and NCTA. All rights reserved. 7

Table 3 - Service Tests for validating Ethernet SLA s Service Activation Test Description Comment Connectivity, Throughput and Auto-Negotiation RFC-2544 Single Stream Pipe test Verify basic connectivity Verify best effort throughput Validate auto negotiation settings to identify half/full duplex limitations Industry-standard service activation test for single-service Ethernet and IP (i.e. pipe test) Measures key performance indicators and bandwidth profile such as: throughput, latency, packet Jitter, frame loss, and committed burst size (CBS) Y.1564 The industry standard service activation test for multi-service Ethernet and IP ( Triple Play ) Measures KPIs and bandwidth profile such as: CIR, EIR (Throughput) Frame Delay (FD), Latency Frame Delay Variation (FDV), Jitter Frame Loss Rate (FLR) Committed Burst Size (CBS), Policing Layer 2 Control Plane Confirm transparent forwarding of Ethernet traffic through the providers network RFC-6349 Automated and repeatable TCPthroughput test per IETF RFC 6349 standards, including key performance metrics of TCP efficiency and Buffer delay Y.1731 Performance monitoring and PM protocol. Can be used for service testing including loopback, frame delay, frame delay variation, frame loss Pre-Check prior to complete SLA testing. Commonly done at service activation with loop-back of remote device. This is an out of service test Testing in both directions, both independently and concurrently (independent transmissions from both ends) for bi-directional testing is critical to determine which direction is not meeting the SLA. Single ended loopback modes cannot isolate which direction. Commonly done at service activation with loop-back of remote device. Testing in both directions both independently and concurrently (independent transmissions from both ends) for bi-directional testing is critical to determine which direction is not meeting the SLA. Single ended loopback modes cannot isolate which direction. This is an out of service test Done at field turn-up. Typically instrument turn up with loopback from remote device Can be virtualized with centralized reporting. This can be done in-service but utilizes full bandwidth Useful in remote automation 2017 SCTE-ISBE and NCTA. All rights reserved. 8

1.2.4. Operation Administration and Monitoring (OAM) 802.11ag Connectivity Fault Management which is part of the Operational Administration and Maintenance (OAM) protocol allows maintenance and management of each EVC regardless of the transport layer. This allows operators to partition the network across the different boundaries and thirdparty operators. Y.1731 Performance Monitoring OAM protocols allow for devices to have some continuous remote monitoring activities. Y.1731 provides in-service performance monitoring to measure KPI s like frame delay, frame delay variation, frame loss. Y.1731 can also provide fault management capabilities including remote loopback. Y.1731 can be an important part of automated turn-up testing as well. 1.3. How DOCSIS 3.1 enables improved Ethernet services Gigabit services offerings are now available with DOCSIS 3.1 systems. A system that utilizes two 192 MHz wide OFDM downstream channels as well as two 96MHz wide OFDM-A upstream channels is capable of supplying over 2.5 Gbps downstream and 1Gbps upstream of shared capacity. The CableLabs specification for DOCSIS 3.1 devices and services took into consideration the desire to deploy business services over DOCSIS. The new modulation schemes provide improved data efficiency and signaling, and the addition of the DOCSIS Timing protocol provides steady and consistent point to point timing and clock accuracy at the CM egress point. 1.3.1. DTP DOCSIS Timing Protocol The DOCSIS timing protocol provides the ability for the CMTS to reference a timing protocol source and provide the clock on the output of the CM to the end device. DTP is based on the Precision Timing Protocol (PTP) of IEEE-1588-2008 with a few modifications Figure 3 - DTP Clock System When implemented, DTP allow the CMTS and CM to appear as a single DOCSIS system to the outside world. This allows the DOCSIS system to appear as a Boundary clock. This allows the Ethernet system to compensate and minimize the effects of any system delays or frame delay variances. The system delays that are calculated are added to the timestamp, which effectively negates the delays. Delays and variances are issues that made legacy DOCSIS inoperable for most business class services. 2017 SCTE-ISBE and NCTA. All rights reserved. 9

Figure 4 - DOCSIS System Works Like Boundary Clock DTP provides the capabilities and facilities for service providers to design and implement a system. Operators will need to do the DTP tuning and system optimization to meet their desired needs. One consideration is the modem to modem/system to system skew. This variance in modem behavior can be one of the largest sources of timing error in the error budget. Figure 5 - DTP System Skew And Error Budgets CableLabs has provided error budgets for the DTP systems to meet different levels of systems to support deployments such as LTE advanced. Table 4 shows system error budget for the different portions of where errors come in the DOCSIS network. 2017 SCTE-ISBE and NCTA. All rights reserved. 10

Table 4 - DTP System Timing Error Budget (table 10-9 CM-SP-MULPIv3.1-I11-170510 Parameter Level I System (GPS location requirements) Level II System (Relaxed positioning) Level III System (LTE Advanced Macro Cell + addnl. Level IV System (LTE Advanced macro cells and small cells Level V System Current DOCSIS implementation T-cmts-error +/- 20 ns +/- 40 ns +/- 150 ns +/- 200 ns +/- 500 ns T-cm-error +/- 20 ns +/- 40 ns +/- 200 ns +/- 300 ns +/- 500 ns T-docsis-error +/- 40 ns +/- 80 ns +/- 350 ns +/- 500 ns +/- 1000 ns T-source-skew 5 ns 10 ns 100 ns 200 ns 500 ns T-hfc-error +/- 7.5 ns +/- 15 ns +/- 50 ns +/- 150 ns +/- 250 ns T-cm-cm-skew 100 ns 200 ns 900 ns 1500 ns 3000 ns 1.3.1.1. HFC error portion Looking at Table 4 on error budget it can be seen that the HFC error is one of the smaller components. This is due to the consistent nature of HFC propagation delay. DTP/PTP account for the delays and variations from CMTS to CM due to fiber propagation delay, coax delay and remote node data conversion delays. 2. Best Practices for SLA testing Best practices for SLA compliant Ethernet Service activation include physical layer through application layer testing. Full KPI testing including RFC-2544 or Y.1564 is recommended to validate proper EVC functionality. It is recommended to do testing of the Layer 2 Control Plane to validate that the control plane traffic flows transparently from end to end and ensure that the control plane traffic flows. As a test to validate the actual end user customer experience and optimize any customer equipment, RFC-6349 tests are recommended. The RFC-6349 tests throughput at layer 4 TCP traffic which is what actual client users will be experiencing. 2017 SCTE-ISBE and NCTA. All rights reserved. 11

2.1. PTP/DTP timing Figure 6 - Best practices for complete service activation For technicians and engineers who must install Carrier Ethernet, Ethernet Backhaul, and PTP (IEEE 1588v2) circuits (like the DOCSIS DTP), testing the OWD, and 1588v2 performance referenced to CDMA and/or GPS receivers can save hours of troubleshooting by detecting asymmetric traffic ensuring proper handoffs for time-sensitive service-critical (mobile) applications. This solution can attain accuracies 10 times greater than most common SLAs, permitting service providers and operators to differentiate their offering and allowing network planners better understand delay tolerances affecting their applications. Figure 7 - OWD and 1588V2 testing connection using GPS source 2017 SCTE-ISBE and NCTA. All rights reserved. 12

2.2. OWD measurements for Mobile Backhaul SLA s and Carrier Ethernet Measuring highly accurate one-way metrics, including OWD and packet jitter, in an Ethernet/IP backhaul scenario improves application troubleshooting and ensures thorough testing and verification of SLAs. Devices at the very edge of the network still can experience asymmetric delays. For example, in a mobilevoice application, increased delay may cause edge devices to buffer the information, thus smoothing out the speech. Unfortunately, unequal or asymmetrical delay can cause one side of the conversation to sound perfectly clear, while the other side appears to constantly talk over the speaker. Avoiding this requires verifying the OWD metric during installation and recording the measurement for future monitoring and troubleshooting as necessary. OWD measurements are important in validating the DOCSIS DTP system design supports the proper type of service and for example support an LTE advanced backhaul situation. Figure 8 - PTP/DTP One Way Delay Testing with External GPS reference 2.3. Using automation with remote probe to speed up service activation Service turn up normally involves sending a technician to the site to do the initial connection and activation. It is recommended to have the technician do an initial abbreviated connectivity and brief service test to ensure all EVC configurations and switch configurations are working properly. Lengthy testing can then be kicked off using virtual probes or physical hardware probes that can automate the RFC testing and be running multiple tests in parallel. 2017 SCTE-ISBE and NCTA. All rights reserved. 13

Figure 9 - Example of SLA Testing with Automation for Efficient Turn Up and Activation Example of best practice for a typical workflow on cell site activation: Tech goes to a cell site Tech tests RF and DOCSIS network for proper operation and Throughput Tech install DOCSIS 3.1 Modem/Gateway Virtual Probe or HW probe is placed in wait for loopback mode Tech run s an abbreviated RFC-2544 test with a couple of frame sizes and only throughput testing to check for connectivity 15minute timeframe Tech installs NID (if separate from D3.1 modem) & Cell Site Gateway Tech notifies the SYSTEM that there is connectivity and initiates test from Virtual Probe or HW probe. Full RFC-2544 test is run to NID/Customer equipment o NOTE 1: This could be run from both directions: Portable to Virtual probe or Virtual Probe to Portable o NOTE 2: A quick test should be run on each configured VLAN Value of the workflow: Keeps Techs moving and working Sites turned up faster Allows for full testing of EVC configuration (QOS, CIR, CBS, EIR, EBS, PIR, Frame Delay, Frame Delay Variation, and Frame Loss) 2017 SCTE-ISBE and NCTA. All rights reserved. 14

Conclusion Legacy DOCSIS prior to DOCSIS 3.1 had limitations that prevented it from being a serious contender as a delivery mechanism for high performance SLA compliant Ethernet services. DOCSIS 3.1 provided additional signaling and timing mechanisms into the standard that equipment vendors and operators can leverage to create DOCSIS 3.1 systems capable of supporting key Ethernet services such as Advanced LTE. In particular, the DTP adoption of Ethernet PTP timing eliminates the problems associated with the delays and delay variations in legacy DOCSIS by making the entire DOCSIS system look like a border clock. When enabling SLA services, there are a set of best practices to validate the KPI s associated with the Ethernet circuit. Traditional tools, including RFC-2544 and Y.1564 are the cornerstone of EVC validation. Higher level Layer 2 control plane and RFC-6349 user experience validation should also be included. Service Activation for the EVC s can be optimized with automation using a testing solution that leverages virtual test probes and/or hardware test probes so technicians can rapidly progress from activation to activation. Abbreviations AP bps BERT BSOD CBS CIR CM CMTS CPE DTP EVC EIR FD FDV FEC FLR HFC Hz ISBE KPI L2VPN LTE MEF MTTR NID OAM OWD access point bits per second Bit Error Rate Test Business Service Over DOCSIS Committed Burst Size Committed Information Rate Cable Modem Cable Modem Terminating System Customer Premise Equipment DOCSIS Timing Protocol Ethernet Virtual Circuit Excess Information Rate Frame Delay Frame Delay Variation forward error correction Frame Loss Rate hybrid fiber-coax hertz International Society of Broadband Experts Key Performance Indicator Layer 2 Virtual Private Network Long Term Evolution (wireless service) Metro Ethernet Forum Mean Time To Repair Network Interface Device Operational Administration and Maintenance One Way Delay 2017 SCTE-ISBE and NCTA. All rights reserved. 15

RFC SCTE SLA TLS UNI VLAN Request For Comment Society of Cable Telecommunications Engineers Service Level Agreement Transparent LAN service User Network Interface Virtual Local Area Network Bibliography & References Data-Over-Cable Service Interface Specifications, DOCSIS 3.1, MAC and Upper Layer Protocols Interface Specification, CM-SP-MULPIv3.1-I11-170510, May 10, 2017 Data-Over-Cable Service Interface Specifications Business Services over DOCSIS, L2VPN Development Guidelines Technical Report, CM-TR-L2VPN-DG-V01-121206 Metro Ethernet Forum: Bandwidth Profiles for Ethernet Services, Ralph Santitoro One-Way Delay and PTP (IEEE 1588v2) Test Applications, Viavi Solutions http://www.viavisolutions.com/en-us/literature/one-way-delay-and-ptp-ieee-1588v2-test-applicationsproduct-and-solution-briefs-en.pdf The Essentials of Ethernet Service Activation Five important tests explained, Viavi Solutions http://www.viavisolutions.com/en-us/literature/essentials-ethernet-service-activation-overview-productand-solution-briefs-en.pdf The Essentials of Ethernet Service Activation Single-Service Enhanced RFC-2544, Viavi Solutions http://www.viavisolutions.com/en-us/literature/enhanced-rfc-2544-single-service-test-product-andsolution-briefs-en.pdf The Essentials of Ethernet Service Activation Multi-Service Y.1564 SAMComplete, Viavi Solutions http://www.viavisolutions.com/en-us/literature/y1564-samcomplete-multi-service-test-product-andsolution-briefs-en.pdf The Essentials of Ethernet Service Activation RFC 6349 TrueSpeed Layer 4 TCP Throughput, Viavi Solutions http://www.viavisolutions.com/en-us/literature/rfc-6349-test-truespeed-product-and-solution-briefsen.pdf 2017 SCTE-ISBE and NCTA. All rights reserved. 16