3D Echocardiography Development Timeline

Similar documents
This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up.

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software

Chapter 32 3-D and 4-D imaging in Obstetrics and Gynecology

Volumetric Analysis of the Heart from Tagged-MRI. Introduction & Background

GE Healthcare. Vivid E9 XDclear. with

GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

7D Cardiac Flow MRI: Techniques & Automation of Reconstruction

High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions

Chapter 9 Conclusions

Robust Live Tracking of Mitral Valve Annulus for Minimally-Invasive Intervention Guidance

GE Healthcare. Vivid E9 XDclear. with. healthymagination. GE imagination at work

Technical Principles of Transthoracic Three-Dimensional Echocardiography

4D Auto MVQ (Mitral Valve Quantification)

IHE Cardiology Technical Framework Supplement. Evidence Documents Profile. Cardiology Options: Stress Testing CT/MR Angiography

WE DEVELOPED A NOVEL MULTI-BEAT image fusion technique using

Embedded Systems. Cristian Rotariu

Accurate Regression-based 4D Mitral Valve Segmentation from 2D MRI Slices

Motion Compensation from Short-Scan Data in Cardiac CT

Lecture 6: Medical imaging and image-guided interventions

Corso di laurea in Fisica A.A Fisica Medica 4 TC

EchoPAC Software Only v201

연구용유방초음파질관리 원광대학병원김혜원

VEVO 2100 Sole Source Specifications

Using TeraRecon intuition Viewer with STAT Quick Reference Guide

Tomographic Reconstruction

SONOS 7500/5500 Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision D.1

Mindray. Hand-carried Diagnostic Ultrasound System. Expanding the Envelope of Performance and Flexibility

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Robust Spatio-Temporal Registration of 4D Cardiac Ultrasound Sequences

Medical Image Processing: Image Reconstruction and 3D Renderings

Digital Image Processing

Image Guidance and Beam Level Imaging in Digital Linacs

4DM Packages. 4DM Packages & License Types. Information to help you order the appropriate licenses for your site.

A powerful, software-based beamformer image reconstruction platform

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Modeling Mitral Valve Leaflets from Three-Dimensional Ultrasound

4D Cardiac Reconstruction Using High Resolution CT Images

Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex

Philips SPECT/CT Systems

VEVO 1100 Sole Source Specifications

Deep dive into SR: Key Object Selection and Radiation Dose Report

Quick Guide. EPIQ 7 Ultrasound System. English

icatvision Quick Reference

Tissue Doppler gated (TDOG) dynamic three-dimensional ultrasound imaging of the fetal heart

Total Variation Regularization Method for 3D Rotational Coronary Angiography

The Near Future in Cardiac CT Image Reconstruction

Respiratory Motion Estimation using a 3D Diaphragm Model

MR Advance Techniques. Vascular Imaging. Class III

csound 2.0 Vivid E95 gehealthcare.com Background

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Image Guidance of Intracardiac Ultrasound with Fusion of Pre-operative Images

A Framework for Real-time Left Ventricular tracking in 3D+T Echocardiography, Using Nonlinear Deformable Contours and Kalman Filter Based Tracking

Cardiac Disease Recognition in Echocardiograms Using Spatio-temporal Statistical Models

Ch. 4 Physical Principles of CT

Learning Anatomical Image Representations for Cardiac Imaging

VieW 3D. 3D Post-Processing WorKstation THE THIRD DIMENSION. Version 3.1

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Certificate in Clinician Performed Ultrasound (CCPU)

997-10, Daechi-dong, Gangnam-gu, Seoul, , Korea Tel: Fax:

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

03:47:29PM S3194 # MHz 180mm YNHH. MSc Thesis. 3D Transesophageal Echocardiography using a fast-rotating transducer. Kyriakos Nathanail

The Supreme 3D/4D Ultrasound. The Supreme 3D/4D Ultrasound. CT-V20-ICM

Chapter 9 Field Shaping: Scanning Beam

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.

A Virtual Reality Training System for Pediatric Sonography

FINDING THE TRUE EDGE IN CTA

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Combination of Markerless Surrogates for Motion Estimation in Radiation Therapy

US 1.

Compressed Sensing for Rapid MR Imaging

Mohammad Baharvandy & Sina Fazelpour

19 CP Replace uses of "data set" that do not refer to the PS3.5 defined meaning

Computer-Aided Diagnosis in Abdominal and Cardiac Radiology Using Neural Networks

Motion artifact detection in four-dimensional computed tomography images

Computer-Tomography I: Principles, History, Technology

Visualisation : Lecture 1. So what is visualisation? Visualisation

HPC Infrastructure for and Simulations of Impact of Drug-Induced Arrhythmias in Living Hearts

Tomography at all Scales. Uccle, 7 April 2014

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

Role of Parallel Imaging in High Field Functional MRI

10 Working With Setup Tools

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

Adaptive Multiscale Ultrasound Compounding Using Phase Information

Hitachi Medical Systems America, Inc. Hitachi Medical Corporation

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

Robust Segmentation and Volumetric Registration in

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Magnetic Resonance Elastography (MRE) of Liver Disease

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

ECG MACHINES. Kizlon Medical. Website:

10 Working With Setup Tools

Brilliance CT Big Bore.

Acknowledgments and financial disclosure

SISCOM (Subtraction Ictal SPECT CO-registered to MRI)

The Usage of Optical Flow Algorithm to the Problem of Recovery Contour of the Left Ventricle of the Human Heart on the Ultrasound Image Data

Transcription:

3D Acquisition Strategies and Display Lissa Sugeng, MD, MPH Associate Professor of Medicine Director of the Yale Echo Lab and Echo Core Lab (YCRG) And Peter Flueckiger, MD Advanced Imaging Cardiology Fellow Yale School of Medicine-Dept. Cardiovascular Medicine New Haven, CT A-Mode 1950 3D Echocardiography Development Timeline Gated 3D 1970-1990 Fully-Sampled Matrix 2003 Sparse Array Matrix 1997 1

Real-Time Three-Dimensional Echocardiography Fully-Sampled Matrix 2003 Fully-Sampled Matrix TEE 2007 The Ideal Acquisition 1 Beat High Volume Rate High Spatial Resolution 2

Components of Acquisition Mode of Acquisition Beats (Single vs Multi-beat) Gain Settings Modes of Acquisition Narrow-Angled Zoom Full-Volume 3

Narrow Angled Acquisition Narrow Angled Acquisition Narrow-Angled Partial Volume One beat acquisition Steerable sector Lateral Elevation 4

Zoom Zoomed Acquisition (TTE) Partial Volume 1-6 beat acquisition Adjustable Sector Zoomed Acquisition (TEE) 5

Zoomed Acquisition Advantages: Focus on structural pathology Higher spatial and temporal resolution Disadvantage: Loss of spatial orientation Wide-Angled Acquisition 6

Wide-Angled Acquisition Method: Matrix Array Probe Stitch Volume Wide-Angled Scan 1 beat 6 beat Components of Acquisition Mode of Acquisition Narrow Sector Focused Sector (Zoom) Wide Sector Beats Single Beat Multibeat (2,4,6, HVR) Gain Settings 7

1 Beat Acquisition 2 Beat Acquisition 8

4 Beats Acquisition Beats 6 Beats 9

High Volume Rate (HVR) Multibeat High Volume Rate (HVR) 10

Single vs Multi- Beat Single Beat Overcomes rhythm and respiratory gating artifacts Multi Beat Higher temporal resolution Poor temporal resolution Requires optimal patient, provider conditions Susceptible to gating issues Components of Acquisition Mode of Acquisition Narrow Sector Focused Sector (Zoom) Wide Sector Beats Single Beat Multibeat (2,4,6, HVR) Gain Settings 11

Optimize 2D and 3D (Gain and TGC) Reduce Overall Gain Adjust TGC Factors To Consider During Acquisition What is your region of interest? Valve (or small structures) Chamber (or large stlurctures) What is important? Spatial Resolution Volume Rate Or both Are there rhythm or respiratory issues? No ECG available/ Atrial fibrillation/ irregular rhythms Intubated patient Breath holds 12

Valvular Ds. Small structure Region of Interest ROI Small Volume High Volume Rate High Spatial Resolution Region of Interest ROI Valvular Ds. Chamber Small Volume High Volume Rate High Spatial Resolution Large Volume Highest Volume Rate Good Spatial Resolution 13

Optimizing 3DE Operator The Patient Sonographer Machine Acquisition Requirements Good Quality Volume Data Operator Well trained in TEE and 3D TEE Centered Region of Interest Find the right window Use Ante-, Retro-, Left and Right Flexion Steady Imaging 14

Acquisition Requirements Good Quality Volume Data The Patient Patient s Image Quality and Anatomy Presence of Air and Poor contact Hiatal Hernia Esophageal abnormalities Rhythm and Rate Irregular rhythms Heart rate extremes Sedation General Anesthesia Moderate or No Sedation Acquisition Requirements Good Quality Volume Data Operator (Sonographer) Well trained in 2D and 3D TTE Optimal 2D Imaging suboptimal 2D results in suboptimal 3D data sets Appropriate echo window for structure of interest Works within echo lab contraints (time, patient load, etc.) 15

Acquisition Requirements Good Quality Volume Data The Sonographer Knowledgeable about the TEE protocol in addition to 2D and 3D TEE: Collaboration between Echocardiographer and sonographer Good communication Understand 3D workflow Optimizes 2D and 3DE Gain and TGC Goal Optimum Acquisition The Machine Gain Depth Space-Time Adjustment Sector Size Zoom Display Pathology 16

Sector Change Wide Narrow Depth Change Higher Depth Lower Depth 17

Optimizing Spatial and Temporal Resolution MV (high depth) MV Zoom Space Time Balance T1 S1 S2 S3 18

Balancing Spatial Temporal Depth Sector size Zoom Space - Time 3D Color Acquisition Ideal Acquisition for 3D Color Flow 1 Beat High Temporal and Spatial Resolution Large 3D B-mode with Steerable Color Flow 19

Multibeat 3D Color Imaging Increase Volume Rate Single Beat Color Imaging Wide Angled Acquisition Large Color Sector Volume rate 13 vps Zoom Acquisition Narrow Color Sector VR = 23 vps 20

Goal of 3D Color Acquisition Visualize the origin of regurgitation Useful in Paravalvular regurgitation Bileaflet degenerative mitral valve disease Understand the severity of regurgitation or the size of the paravalvular leak Paravalvular Leak 21

Steerable Color Sector (Anterior Paravalvular Leak) Steerable Color Sector (Medial Paravalvular Leak) 22

3D Color Acquisition (Quantitation of Volume Flow) Needs a high Volume Rate Narrow color sector Narrow 3D B-mode sector 3D color can include: Both Mitral and Aortic flow Dedicated Valvular flow 3D Display (Types of Display) Volume Rendering Surface Rendering Wire-Frame 2D Tomographic Slices 23

Volume Rendered Images Displays Anatomy and Pathology Dynamic images Thresholding/ Gain adjustments needed Ideal Volume Rendered Display Display that demonstrates the pathology Automated Orientation depending on the specific structure Quick Cut planes 24

Wire-Framed Rendered Tracing ventricular or atrial chambers Tracing valvular structures No anatomic information Results in length, circumference, area or volumetric measurements Surface Rendered Based on a wire-framed reconstruction Surface is applied over the wire-frame No anatomic detail Provide additional information Timing of events Motion Displacement 25

Surface Rendered (Mitral Valve) Multiplanar Reconstructions (MPR) Single MV slice Multiple LV slices 26

Segmentation or Cut Planes Sector Narrowing the Sector Zoom imaging Cropping Box Cut Planes Auto -crop Box-crop Anatomic cut plane D Art Plane icrop Segmentation 27

Cut-Planes 3D Volume Auto Crop Box Crop Cut-Planes 3D Volume icrop D art / 2 click Crop Plane Crop 28

Dual View (Simultaneous Display of 2 Perspectives ) Stitch Artifact 29

Bovie Artifact Electrical Interference Solution: Stop Cautery Probe 30