PSI-MODEM-SHDSL/SERIAL

Similar documents
PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/SERIAL Copper Extender

PSI-GPRS/GSM-MODEM/RS232-QB

PSI-GPRS/GSM-MODEM/RS232- QB

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

onlinecomponents.com

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-CVS NC

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC)

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

This data sheet is only valid in association with the IL SYS INST UM E user manual.

FL COMSERVER /422/485

MINI-PS AC/10-15DC/8

Valueline Industrial PC

PSI-MOS-RS422/FO 850 T

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ETD-BL-1T-OFF-CC- 10S

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

PSI-MOS-PROFIB/FO 850 T

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

FL MC 2000E (SM40) LC

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description

TRIO-DIODE/12-24DC/2X10/1X20

Extract from the online catalog

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

IB IL 24 DI 16 IB IL 24 DI 16-PAC

PHOENIX CONTACT

IBS IL 24 BK RB-T-2MBD

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PHOENIX CONTACT - 10/2009

Extract from the online catalog

PHOENIX CONTACT - 05/2007

QUINT-PS-3x AC/24DC/10

QUINT-PS/ 1AC/24DC/ 5

PSI-MOS-PROFIB/FO 850 T

FL MC 10/100BASE-T/FO-660

PHOENIX CONTACT - 01/2007

Extract from the online catalog

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description

PHOENIX CONTACT - 07/2006

IBS IL 24 RB-LK-2MBD:

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI MCR-SL-MUX-V8-FLK 16

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

PHOENIX CONTACT Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

QUINT-BUFFER/24DC/24DC/40

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

IB IL AO 2/SF... Inline terminal with two analog outputs. AUTOMATION Data sheet 6655_en_06. 1 Description

IB IL 24/48 DOR 2/W-XC-PAC

onlinecomponents.com

PHOENIX CONTACT - 12/2007

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

PI-EX-ME-2NAM/COC-24VDC

STEP-PS/1AC/24DC/1.75

ILC 200 IB ILC 200 IB-PAC

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

MACX MCR-EX-SD LP(-SP)

PI-EX-ME-2NAM/COC-120VAC

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

SUBCON-PLUS-PROFIB...

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

QUINT-PS AC/24DC/10

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

QUINT-PS/ 1AC/24DC/20/CO

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

PSR DC/ESP4/2X1/1X2

MACX MCR-EX-SL-NAM-R(-SP)

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Transcription:

PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices via inhouse cables. Distances of over 20 km can be covered given low data rates and good line characteristics, see Figure 1 on page 5. The modem operates transparently of the protocol and supports RS-232, RS-422 and RS-485 W2 interfaces. All devices have two ports. Point-to-point, redundant point-to-point, line and star structures can be set up without problem. The clearly visible LEDs on the front of the device provide on-site technicians with quick device diagnostics. Every device also has integrated diagnosis functions and a log book. Two individually configurable digital outputs are available for alarm generation for external devices. They can be parameterized using the configuration software. Power is supplied via USB cable, which enables device configuration without external 24 V power supply. 1.1 Features Areas of application Suitable for in-house cables, not for the public telephone network Point-to-point connection Star structure Line structure, up to 255 devices technology Symmetrical data transmission Two ports Up to 15.3 Mbps (2-conductor), 30 Mbps (4-conductor) RS-232 interface (9-pos. D-SUB) RS-232, up to 230.4 kbps Automatic DCE/DTE switch over RS-485 W2/422 interface (COMBICON plug) RS-422, up to 2000 kbps RS-485 W2, up to 2000 kbps RS-485 W2: termination resistor, can be enabled/ disabled Alarm outputs Two digital outputs, can be configured individually The configuration software additionally allows Online diagnostics Guided project configuration Log book function Saving and printing of project and device configurations NOTE: A combination of different modems (e.g. -SERIAL with -Ethernet), is not possible. Make sure that you are always working with the current documentation. This is available for download from www.phoenixcontact.net/catalog. This data sheet is valid for all products listed on the following page:

PSI-MODEM-/SERIAL 2 Ordering data Modem Description Type Order No. Pcs. / Pkt. permanent line modem, for point-to-point, line, and star structures on in-house 2 and 4-wire cables PSI-MODEM-/SERIAL 2313669 1 Accessories Description Type Order No. Pcs. / Pkt. System power supply unit, primary-switched Input voltage range Nominal output voltage Nominal output current 45 Hz... 65 Hz 85 V AC... 264 V AC 24 V DC ±1% 1.5 A MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1 DIN rail connector (2 required) ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561 1 RJ45 (RJ12/RJ11) attachment plug with surge protection for analog telecommunications DT-TELE-RJ45 2882925 1 interfaces. Can alternatively be snapped onto DIN rails. USB cable, USB type A/mini-USB type B, 5-pos., 1 m long PSI-CA-USB A/MINI B/1METER 2313575 1 m USB cable, USB type A/mini-USB type B, 5-pos., 3 m long CABLE-USB/MINI-USB-3,0M 2986135 3 m RS-232 cable, for connecting the modem to a 9-pos. device interface, 2 m long 9-pos. D-SUB/9-pos. D-SUB (socket/socket) PSM-KA9SUB9/BB/2METER 2799474 2 m RS-232 cable, for connecting the modem to a 9-pos. device interface, 0.5 m long 9-pos. D-SUB/9-pos. D-SUB (socket/socket) Adapter cable for connecting the IB IL RS232 and IB IL RS232-PRO Inline communication terminals to an interface converter, e.g., modem, COM server, Bluetooth or fiber optics PSM-KA9SUB9/BB/0,5METER 2708520 0.5 m PSM-KAD-IL RS232/9SUB/B/0,8M 2319200 0.8 m 3 Technical data Supply Supply voltage Nominal current consumption LED indicator Switching outputs 18 V DC... 30 V DC via plug-in COMBICON screw terminal block 24 V DC ±5% (alternative or redundant, via DIN rail connector and system power supply) 5 V DC (configuration only, via mini-usb type B) < 180 ma at 24 V VCC (green LED) Steady light: operation Flashing at 1 Hz: supply via USB (for configuration) 2 x U Nom /150 ma (the digital outputs cannot be used for power supply via the DIN rail connector), short-circuit-proof interface 2 x 2-pos. COMBICON plug-in screw terminal block Type interface according to ITU-T G.991.2.bis 4-wire operation 64 kbps... 30 Mbps (manual setting of the data rate) 384 kbps... 11.39 Mbps (automatic detection of the data rate) 2-wire operation 32 kbps... 15.3 Mbps (manual setting of the data rate) 192 kbps... 5.696 Mbps (automatic detection of the data rate) Over 20 km possible at lower data rates and with good cable quality Connection data (conductor cross section) 0.2 mm²... 2.5 mm² (24-14 AWG) Status and diagnostic indicators 2 x LINK, 2 x STAT (DSL data traffic port A and port B) DIAG (yellow LED), diagnostic messages ERR (red LED), errors TERM (yellow LED), only relevant for RS-485 RS232 (yellow LED) 104460_en_02 PHOENIX CONTACT 2

PSI-MODEM-/SERIAL RS-232 interface 9-pos. D-SUB plug Type RS-232 interface, according to ITU-T V.28, EIA/TIA-232, DIN 66259-1 Can be freely parameterized from 92 bps... 230.4 kbps 15 m, maximum Supported protocols Software handshake (Xon/Xoff), hardware handshake (RTS/CTS), 3964Rcompatible, Modbus RTU/ASCII, transparent protocol - other protocols supported Data format/encoding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length RS-422 interface Plug-in and screw connection via COMBICON plug Type RS-422 interface, according to ITU-T V.11, EIA/TIA-422, DIN 66348-1 Can be freely parameterized from 92 bps... 2 Mbps 1200 m, maximum Supported protocols Modbus RTU/ASCII and others, transparent protocol Data format/encoding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length RS-485 interface Type Supported protocols Data format/encoding Plug-in and screw connection via COMBICON plug RS-485 interface, according to EIA/TIA-485, DIN 66259-4/RS-485 2-wire Can be freely parameterized from 92 bps... 2 Mbps 1200 m, maximum Modbus RTU/ASCII and others, transparent protocol Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length USB interface (configuration/diagnostics) Mini-USB type B, 5-pos. Type USB 2.0 5 m, maximum, only for configuration and diagnostics General data Ambient temperature range Operation (no other modules supplied via the device): Freestanding (40 mm spacing) -20 C... +60 C Connected in series (low power dissipation of modules connected in series) -20 C... +55 C Connected in series (without restrictions) -20 C... +50 C Operation (other modules supplied via the device (1.5 A, maximum)) -20 C... +45 C Storage/transport -40 C... +85 C Housing ME 35 with 5-pos. bus contact and ground contact Material PA 6.6-FR, V0, green Dimensions (H x W x D) 99 x 35 x 114.5 mm Weight 205 g Functional earth ground Housing contact to DIN rail Degree of protection IP20 Electrical isolation DIN EN 50178 (Supply // RS-485, RS-422 // DSL port A // DSL port B // FE) 104460_en_02 PHOENIX CONTACT 3

PSI-MODEM-/SERIAL General data [...] MTBF according to Telcordia standard 1004 years Telcordia standard, 25 C ambient temperature, 21% operating cycles (5 days a week, 8 hours a day) 199 years Telcordia standard, 40 C ambient temperature, 34.25% operating cycles (5 days a week, 8 hours a day) Test voltage 1.5 kv AC, 50 Hz, 1 min. Vibration resistance According to IEC 60068-2-6: 5g, 150 Hz Shock resistance 15g in each space direction, according to IEC 60068-2-27 Noise emission EN 55011 Noise immunity EN 61000-6-2 Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC UL, USA/Canada UL 508 listed in preparation Manufacturer's declaration EN 50121-4 (Railway applications - Electromagnetic compatibility, Part 4: Emission and immunity of the signaling and telecommunications apparatus) Exceptions include installations within the 3 m area and safety-related devices. For these devices, there are further requirements according to EN 50121-4 Table 1, Note 1. Section 1, Paragraph 3 of EN 50121-4 applies. Phoenix Contact QUINT power supply units are to be used directly on the device. Conformity assessment according to directive 94/9/EC X II 3 G Ex nac IIC T4 X 104460_en_02 PHOENIX CONTACT 4

PSI-MODEM-/SERIAL 4 Range The maximum possible transmission speed greatly depends on the cable length, the cable cross section, and the cable type. 16.0 14.0 12.0 data rate (Mbps) 11.0 10.0 8.0 6.0 4.0 PE 0.4 mm (0.13 mm²) PE 0.9 mm (0.64 mm²) PE 1.4 mm (1.54 mm²) 2.0 0.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20 Figure 1 km Dependence of the maximum data rate (Mbps) on the line length in a 2-conductor connection Figure 1 illustrates the dependency of the maximum data rate on the distance with three cable types. Higher ranges can be achieved with high quality cables and larger diameter cables. Phoenix Contact's industrial permanent line modems permit data rates in 2-conductor operation from 32 kbps to 15.3 Mbps. Data rates of up to 30 Mbps are possible in 4-conductor operation. permanent line modems are suitable for in-house cables, not for public telephone networks. 104460_en_02 PHOENIX CONTACT 5

PSI-MODEM-/SERIAL 5 Application examples 5.1 Point-to-point connection 5.3 Star structure 2 Wire B... B... E 4 Wire A C A C D F Line 1 For more information, please refer to the UM EN PSI-MODEM-/SERIAL user manual. 5.2 Line structure A Line 2 B C D E F Atypical application cases are also supported, e.g. the linear structure of multiple RS-232 interfaces or a mixed operation using different interfaces. The customer does, however, then need his custom protocol. The modem transmits the data protocol transparently. The devices are connected via the DIN rail connector (T-BUS) in the head station. The DIN rail connector supports RS-485. It can not be used with RS-232 and RS-422. In order to configure a star structure, you must create several line structures. In the example, you need to create two line structures, each consisting of three devices. For more information, please refer to the UM EN PSI-MODEM-/SERIAL user manual. For more information, please refer to the UM EN PSI-MODEM-/SERIAL user manual. 104460_en_02 PHOENIX CONTACT 6

PSI-MODEM-/SERIAL 6 Use in potentially explosive areas The PSI-MODEM-/SERIAL is intended for use in potentially explosive atmospheres that require category 3G equipment. Special conditions Observe the specified conditions for use in potentially explosive areas. Install the device in suitable housing with IP54 protection, minimum, that meets the requirements of EN 60079-15. Disconnect the block power supply before:: Snapping it on or disconnecting it Connecting or disconnecting cables. The mini-usb configuration interface may only be used if it has been ensured that there is no potentially explosive atmosphere present. Connection to the D-SUB interface is only permitted if the screw connection is fully tightened. Only devices which are designed for operation in zone 2 potentially explosive areas and are suitable for the conditions at the installation location may be connected to the signal circuits in zone 2. 104460_en_02 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 7 www.phoenixcontact.com