S800 I/O ABB Automation

Similar documents
Industrial IT. General Information and Installation. 800xA - Control and I/O S800 I/O. Version 4.1

iologik 4000 Series (M) Modules

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

iothinx 4500 Series (45MR) Modules

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

DeltaV S-series Traditional I/O

Submittal Data Sheet WAGO Node for itm

S800 I/O. Modules and Termination Units with Intrinsic Safety Interface. Power and productivity for a better world TM

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

Omega and Red Lion team-up!

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

List of Components Versions for Safetec SFT-9000 systems

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Cube67 - Modular I/O station

Industrial Automation with PLC. LM MICRO SERIES PLC Selection Guide

Cube20. Application-oriented. Installation-friendly. Efficient

DeltaV M-series Traditional I/O

Compact 800 Our control applications are simple and effective

AC 800M for Compact Product Suite Outline of all modules

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

MTL8000-2/x Series Modular I/O

Intrinsic Safety Control Drawing

DeltaV SIS TMConditioning Components

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Backplane. Allen-Bradley. System integration. Backplane

Intrinsically Safe Barriers

DeltaV M-series Traditional I/O

Automation Unit TM 1703 ACP. SICAM 1703 flexible for all applications. Answers for energy.

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Remote I/O Modules EH-RIO2 Series

Backplane. System integration. Backplane

Features and Benefits. Certifications

RS-485 I/O Modules: ADAM-4000

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

FEATURES DESCRIPTION FEATURES

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

General information. Display. Supply voltage. Input current

TX-I/O Product Range. Features. Description. Document No January 24, 2007

POINT I/O Family. Chapter. Overview

DeltaV M-series Traditional I/O

EXOcompact. Third generation freely programmable controllers

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

On-Machine Modular I/O

DeltaV Electronic Marshalling

PXR Series Advanced Self-Tuning Temperature and Process Controllers

SIMATIC. Distributed I/O Device ET 200iSP. Preface, Contents. Product Overview Getting Started with Commissioning. Configuration Options.

S-series Electronic Marshalling

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Redundant System Redundant System P9-1-1

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

Wall-/Pipe Mounted Universal Process Indicator

Expansion Module HZS 541-1S

TURCK Modular Industrial I/O System

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

S-series IS Electronic Marshalling

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Backplane. System integration. Backplane

EXOcompact. Freely programmable controller

PAC BI-DP BIM and 8701-CA-BI Carrier

Features and Benefits. Certifications

AC 800M Controllers Outline of all modules

icex-cmtm General specs and Installation guide

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP

5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS

Multifunction Transducer MT440

M-series Traditional I/O

SCADAPack. I/O Expansion & Communication Modules

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

S-series Electronic Marshalling

SAI Active Universal Pro

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

Modulus Selection Guide January 1, 2019 Industrial Control Links, Inc.

CI541 PROFIBUS Communication Interface Module

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage

8B SLX300 Data Acquisition System

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

SmartSlice. System Configuration

MIC-2 Multi-instrument DATA SHEET

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Transcription:

S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 1

S800 I/O S800 I/O 3 : Fieldbus Communication Interface (FCI) I/O Module Module Termination Unit (MTU), Compact or Extended version 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 2

S800 I/O CI830 PROFIBUS - DP I/O / / I/O I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 3

S800 I/O MTU 2, 50 250 2 DIN- / I/O- I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 4

S800 I/O FCI I/O I/O MTU MTU S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 5

S800 I/O MTU 2 ~ ~ = + - 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 6

S800 I/O MTU ~ = + ~ - 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 7

S800 I/O FCI I/O Modules Internal bus Superv. 24V A Superv. 24V B A B 24 V D.C. Isolation; - I/O Module to I/O bus, - I/O Module to I/O Module - Isolation channel to channel ( or group) Overload/current protection Optional PROFIBUS-DP RS485 I I AI AO DI 24 V DO 220 V DO 24 V Class 1, Division 2 Certified 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 8

S800 I/O SD811, 110-230 V a.c., 24V d.c. 2,5A SD812, 110-230 V a.c., 24V d.c. 5A SD811 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 9

S800 I/O Electrical safety IP20, Ventilated modules Overvoltage category, U < 50V, II IEC664 (50V isolation voltage) Overvoltage category, U > 50V, III IEC664 (250V isolation voltage) Meets EC EMC directives (CE Marked) Ambient Temperature +55 C Horizontal mounted modules (both compact & extended MTU) +40 C Vertical mounted modules (compact MTU, +55 C for Extended MTU) Corrosive gases According to ISA class G2 (1000Å/28 days) pollution degree 2 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 10

S800 I/O CI830 I/O 2) I/O 3) 162 mm (6,4 ) 104 mm (4 ) 84 mm (3,3 ) 58 mm (2,3 ) 20 mm (0,79 ) 20 mm (0,79 ) 120 mm (4,7 ) Height = 122 mm (4,8 ) 1) Height = 122 mm (4,8 ) 1) 1) Including height of DIN-Rail 2) Compact MTU (2-wire connection) 3) Extended MTU (3-wire connection) 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 11

S800 I/O ModuleBus & I/O Clusters ModuleBus FCI I/O ModuleBus FCI I/O ModuleBus FCI I/O-clusters FCI I/O-modules PROFIBUS-DP I/O-station Electrical ModuleBus Optical ModuleBus Optical modem I/O-modules I/O-cluster 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 12

S800 I/O modulebus 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 13

Optical ModuleBus & I/O Clusters I/O 12 I/O Modules I/O Fiber Optic ModuleBus S800 I/O Station Cluster 1 TB820 Optical Modem Cluster 2 to Cluster 7 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 14

Options - Fiber Optic ModuleBus TB820 ModuleBus Modem ModuleBus ModuleBus Modems 7 12 I/O 24 I/O I/O 384 DI/DO 192 AI/AO Fiber Optic ModuleBus TB820 Optical Modem S800 I/O Station Cluster 1 Cluster 2 to Cluster 7 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 15

Electrical ModuleBus TK801, Extension Cable, length 0,3, 0,6, 1,2 m (1, 2, 4 ft.) FCI Bus Terminator TB 807 TB 805, Extension cable outlet TB 806, Extension cable inlet Maximum 2.5 meters (8.2 ft.) TK801, Extension cables, 0,3m (1ft.) 0,6m (2 ft.) 1,2m (4 ft.) TB805, Module bus Outlet TB806, Module bus Inlet TB 807 Module bus Termination 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 16

Electrical ModuleBus Extension cable TK801 with Outlet TB805 and Inlet TB806 Extension cable used in a S800 I/O-Station 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 17

Optical ModuleBus & I/O Clusters - Simplex Connection I/O Station Maximum length of any cable is: 15m (49 Ft.) for Plastic Fiber 200m (667 Ft.) for HCS Glass Fiber Rx Tx Cluster 1 TB820 Cluster 2 TB820 Cluster 3 TB820 Cluster 7 TB820 Rx Tx Rx Tx Rx Tx Rx Tx Simplex FCI TB820 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 18

Optical ModuleBus & I/O Clusters - Duplex Connection I/O Station Maximum length of any cable is: 15m (49 Ft.) for Plastic Fiber 200m (667 Ft.) for HCS Glass Fiber Rx Tx Cluster 1 TB820 Rx Tx Cluster 2 TB820 Rx Tx Cluster 3 TB820 Rx Tx Cluster 7 TB820 Rx Tx Rx Tx Rx Tx Rx Tx Duplex I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 19

Optical ModuleBus & I/O Clusters - Mixed Connection I/O Station Maximum length of any cable is: 15m (49 Ft.) for Plastic Fiber 200m (667 Ft.) for HCS Glass Fiber Rx Tx Cluster 1 TB820 Rx Tx Cluster 2 TB820 Rx Tx Cluster 3 TB820 Rx Tx Cluster 7 TB820 Rx Tx Rx Tx Rx Tx 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 20

PROFIBUS Dual Media Provides Redundant Physical Path for PROFIBUS data Protects against loss of communication due to cable break PROFIBUS-DP Dual Media Controller RLM 01 S800 I/O Station 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 21

S800 I/O 32 I/O 24 I/O I/O Physical bus: RS-485 up to 12 Mbit/s Maximum PROFIBUS-DP length =< 1200m Controller S800 I/O Station PROFIBUS-DP S800 I/O Station Optical Modulebus 1-7 S800 I/O Station 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 22

Analog I/O Modules Available AI810 8 ch Analog Input Current Source, 0(4)-20mA, 0-10V, 12 bits, Accuracy 0.2%, Isolation: 1 group of 8 AI820 4 ch Analog Input -20-+20mA, -10-+10V, -5-+5V, 12 bits, Accuracy 0.2%, Isolation: 1 group of 4 AI830 8 ch RTD Input 100 ohm Pt, Ni, Cu, 120 ohm Ni, 0-400 ohm resistor, 15 bits, Accuracy 0.1% AI835 8 ch (7+1 cold junct) Thermocouple Input Type B, C, E, J, K, N, R, S, T, +/-75mV, 14 bits, Accuracy 0.2% AI890 8 ch Analog input with integrated Intrinsic safe interface 0(4)-20mA, 12 bits, Accuracy 0.1%, Isolation: 1 group of 8 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 23

Analog I/O Modules Available AO810 8 ch Analog Output 0(4)-20mA, 14 bits, Accuracy 0.2%, Isolation: 1 group of 8 AO820 4 ch Isolated Analog Output -20-+20mA, -10-+10V, -5-+5V, 12 bits, Accuracy 0.2%, Isolation: Individual AO890 8 ch Analog Output with integrated Intrinsic safe interface 0(4)-20mA, 12 bits, Accuracy 0.1%, Isolation: 1 group of 8 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 24

Binary I/O Modules Available DI810 16 ch Binary Input 24 VDC, Isulation: 2 groups of 8 DI811 16 ch Binary Input 48 VDC, Isulation: 2 groups of 8 DI814 16 ch Binary Input (current source) 24 VDC, Isulation: 2 groups of 8 DI820 8 ch Binary Input 110 VDC / 120 VAC, Isulation: Individual DI821 8 ch Binary Input 220 VDC / 230 VAC, Isulation: Individual DI890 8 ch Binary Input With integrated Intrinsic Safe barrier Namur or contact, Isulation: Individual DP820 2 ch Pulse counter 0,25 Hz...1,5 MHz 5/24 VDC, Isulation: Individual 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 25

Binary I/O Modules Available DO810 16 ch Binary Output (transistor source) 24 VDC, 0.5 A, Isulation: 2 groups of 8 DO814 16 ch Binary Output (transistor sink) 24 VDC, 0.5 A, Isulation: 2 groups of 8 DO815 8 ch Binary Output (transistor source) 24 VDC, 2 A, Isulation: 2 groups of 4 DO820 8 ch Binary Output (Relay N.O) 5-250 V AC/DC, 3A, Isulation: Individual DO821 8 ch Binary Output (Relay N.C) 5-250 V AC/DC, 3A, Isulation: Individual DO890 4 ch Binary Output with integratred Intrinsic safe interface 12 VDC, 40 ma, Isulation: Individual 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 26

S800L I/O Modules Available AI801 8 ch Analog Input Current Source, 0(4)-20mA, 0-10V, 12 bits, Accuracy 0.2%, Isulation: 1 group of 8 AO801 8 ch Analog Output 0(4)-20mA, 12 bits, Accuracy 0.2%, Isulation: 1 group of 8 DI801 16 ch Binary Input 24 VDC, Isolation: 1 group of 16 DO801 16 ch Binary output 24 VDC, 0.5 A, Isolation: 1 group of 16 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 27

Slide Presentation Information Sheet About the Presentation Title: Control IT S800 I/O Brief: S800 I/O Basic concept Intended Audience: Usage Restrictions: Release : Feb. 1, 2000 No. of Pages: 32 About the Author First edition Revised Special Instructions: Please provide the above information on all presentations. This slide can then be hidden and will not show or print. 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 28 Customer (Management), SI, Sales None Patrick Cao : Patrick-peng.cao@cn.abb.com