Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Similar documents
Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

For Sales and Support call KMParts.com (866)

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Disconnect Switches. Safe Switching and Disconnecting

15, 6" panel PC with capacitive multi-touch (PCT), 2xEthernet, 2xUSB3.0, 1xRS232, 1xRS485, Galileo Runtime License

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Electronic timer CT-ARS.11

TeSys IEC Contactors and Overload Relays

Electronic timer CT-ERD.12

TeSys contactors From 115 to 2750 A

Electronic timer CT-ERS.21

CS8 Industrial Control Relays

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-AHD.22

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

Contact protection relay

UL 489 DIN Rail Miniature Circuit Breakers

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

UL 489 DIN Rail Miniature Circuit Breakers

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

1.4. Pushbuttons and Indicating Lights. Product Overview

Motor protection relays

1492-SP Supplementary Protectors

Datasheet - SRB 301LC/B-24V

Switching relay CT-IRE with 1 c/o (SPDT) contact

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

3 Pole Contactors with AC operating coils

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Allen-Bradley 700-K40E-DJ

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Datasheet - SLB 200-C04-1R

Installation / Control Technique

Micro Contactor MA Series

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Ultra Slim Relays 24

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

TeSys protection components

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Messaging module CP-C MM

Datasheet SRB301ST 24V (V.2)

Datasheet - SRB 402EM-24V

Three-phase monitoring relay

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

002 Easy Control Relays System Overview

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Protection Equipment

RM4TR31 three-phase network control relay RM4-T - range V

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

QUINT-PS/ 1AC/24DC/20/CO

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

CS7 Industrial Control Relays

02/11/2015

Thermistor motor protection relay CM-MSS.11

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

K-Line Mini - Contactors, Overload Relays and Accessories

WEG Contactors - CWM and CWME Series

RM4TA32 three-phase network control relay RM4-T - range V

SPST-NO SPDT DPST-NO DPDT

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Transcription:

Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor relays Description Basic devices with positive operation contacts Connection technique Screw terminals Rated operational current AC-15 Contacts 220 V 230 V 240 V I e A 4 380 V 400 V 415 V I e A 4 N/O = Normally open 3 N/O N/C = Normally closed 1 NC Contact sequence Code number and version of combination Distinctive number 31E Can be combined with auxiliary contact module DILA-XHI(V) Actuating voltage 24 V DC Voltage AC/DC DC operation Suppressor circuit built-in Instructions Contact numbers to EN 50011 Coil terminal markings to EN 50005 built-in suppressor circuit' Technical data General Standards IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA Lifespan, mechanical DC operated Operations x 10 6 20 Maximum operating frequency Operations/h 9000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25 - +60 Enclosed C - 25-40 Ambient temperature, storage C - 40-80 Mounting position Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Basic unit with auxiliary contact module g N/O contact g 7 N/C contact g 5 01/26/2018 Eaton 276379 ED2018 V40.0 EN 1 / 8

Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight DC operated kg 0.294 Terminal capacities mm 2 Screw terminals Contacts Solid 2 mm 1 x (0,75-4) 2 x (0,75-2,5) Flexible with ferrule 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) Solid or stranded AWG 18-14 Stripping length mm 10 Terminal screw M3.5 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1 x 6 Max. tightening torque Nm 1.2 Positive operating contacts to ZH 1/457, including auxiliary contact module Yes Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to EN 61140 between coil and auxiliary contacts V AC 400 between the auxiliary contacts V AC 400 Rated operational current A Conventional free air thermal current, 1 pole AC-15 Open at 60 C I th =I e A 16 220 V 230 V 240 V I e A 4 380 V 400 V 415 V I e A 4 500 V I e A 1.5 DC current Notes Switch-on and switch-off conditions based on DC-13, time constant as specified. DC L/R 15 ms Contacts in series: A 1 24 V A 10 1 60 V A 6 2 60 V A 10 1 110 V A 3 3 110 V A 6 1 220 V A 1 3 220 V A 5 DC L/R 50 ms Contacts in series: A 3 24 V A 4 3 60 V A 4 3 110 V A 2 3 220 V A 1 Control circuit reliability Failure rate λ <10-8, < one failure at 100 million operations (at U e = 24 V DC, U min = 17 V, I min = 5.4 ma) Short-circuit rating without welding Maximum overcurrent protective device 220 V 230 V 240 V PKZM0 4 01/26/2018 Eaton 276379 ED2018 V40.0 EN 2 / 8

380 V 400 V 415 V PKZM0 4 Short-circuit protection maximum fuse 500 V A gg/gl 10 Current heat loss at I th DC operated W 0.85 Magnet systems Voltage tolerance DC operated Notes Smoothed DC, three-phase bridge rectifiers or smoothed double-wave rectification Pick-up voltage Pick-up voltage min. x U c 0.8 Pick-up voltage max. x U c 1.1 at 24 V: without auxiliary contact component (40 C) Pick-up x U c Voltage tolerance, DC coil without auxiliary contact module, min. pickup voltage x U c 0.7 Power consumption DC operation Without auxiliary contact module Pick-up x U c 1.3 DC operated Pull-in = sealing W 2.6 duty factor % DF 100 Changeover time at 100 % U S (recommended value) DC operated closing delay ms Switching times, DC operated, max. closing delay ms 31 DC operated N/O contact opening delay ms Switching times, DC actuated make contact Opening delay, max. ms 12 Rating data for approved types Auxiliary contacts Pilot Duty AC operated A600 DC operated P300 General Use AC V 600 AC A 15 DC V 250 DC A 1 Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 15.5 Heat dissipation per pole, current-dependent P vid W 1 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 2.6 Heat dissipation capacity P diss W 0 Operating ambient temperature max. C -25 Operating ambient temperature max. C 60 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 01/26/2018 Eaton 276379 ED2018 V40.0 EN 3 / 8

10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Contactor relay (EC000196) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Contactor relay (ecl@ss8.1-27-37-10-01 [AAB716011]) Rated control supply voltage Us at AC 50HZ V 0-0 Rated control supply voltage Us at AC 60HZ V 0-0 Rated control supply voltage Us at DC V 24-24 Voltage type for actuating DC Rated operation current Ie, 400 V A 4 Connection type auxiliary circuit Screw connection Mounting method DIN-rail/screw Interface No Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 3 Number of auxiliary contacts as normally closed contact, delayed switching 0 Number of auxiliary contacts as normally open contact, leading 0 With LED indication No Number of auxiliary contacts as change-over contact 0 Manual operation possible No Approvals Product Standards IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No 01/26/2018 Eaton 276379 ED2018 V40.0 EN 4 / 8

Characteristics 1: Suppressor 2: Auxiliary contact module 01/26/2018 Eaton 276379 ED2018 V40.0 EN 5 / 8

Component lifespan (operations) Ie = Rated operational current 01/26/2018 Eaton 276379 ED2018 V40.0 EN 6 / 8

Component lifespan (operations) Ie = Rated operational current Dimensions 01/26/2018 Eaton 276379 ED2018 V40.0 EN 7 / 8

Contactor with auxiliary contact module Assets (Links) Declaration of Conformity 00002560 Instruction Leaflets IL03407013Z2012_03 Additional product information (links) IL03407013Z (AWA2100-2126) Contactors IL03407013Z (AWA2100-2126) Contactors UL/CSA: Approved rating data ftp://ftp.moeller.net/documentation/awa_instructions/il03407013z2012_03.pdf http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84 01/26/2018 Eaton Industries GmbH http://www.eaton.eu 01/2018 by Eaton Industries GmbH Eaton 276379 ED2018 V40.0 EN 8 / 8