Central Processing Unit (CPU) Replacement

Similar documents
Snap Server 4400 Power Supply

HP rp5700 Repair Central Processing Unit(CPU) Replacement

Adding or Replacing a PCI Card

Dell PowerEdge R940. Upgrading the dual processor to quad processor system

120Ra-1 Pentium III Processor Installation Insert

Wiwynn SV Maintenance User Manual

Mac mini Mid 2011 Heat Sink Replacement

Replacing the SATA PCI Controller Card

Written By: John Sutton

ASSET LGA1366 Top-side Probe

Contivity Extranet Switch Installing Hardware Options Guide

FreeNAS Mini and Mini XL Network Upgrade Kit

Field-Replaceable Units

Installing the NVR Connectivity and 2nd CPU Kits 1

Assembly Instructions: ASUS* Z62F

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

HP ProLiant DL165 G7 Server

Wiwynn SV320 Maintenance User Manual

Oracle <Insert Picture Here>

RMX 2000 MPM to MPM+ Migration Procedure

Computer Assembly Step by Step DRAFT

Written By: Nicholas Ouimet

Installing System Board Options

Figure 4-29 Removing the CPU compartment cover

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

imac Intel 21.5" EMC 2389 Stand Replacement

Dell Inspiron XPS and Inspiron 9100 Service Manual

Installation Guide. Copyright 2005 MSI Computer Corp.

Encore XT Manual Gun Upgrade Kit

Upgrading LVDS Cables Instruction Sheet

Dell Inspiron 660 Owner s Manual

Samsung Galaxy Tab Wi-Fi Motherboard

After completing this chapter, you will meet these objectives:

Removing and Replacing Parts

Written By: Walter Galan

Removing and Installing the ISA and the ISM

Replacing/Upgrading Mac Pro Processors (Early 2008)

OnePlus 5 Screen and Digitizer Assembly Replacement

Installing and Removing SDRAM and DRAM

imac Intel 20" EMC 2105 and 2118 SSD

ALIENWARE AURORA SERVICE MANUAL 01/

TravelMate 6493 Series Disassembly Instruction

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Upgrade & Replacement

RMX 2000/4000 MPMx Migration Procedure

PC9/P9 CPU Card Replacement

Tower to Rack and Rack to Tower System Conversion Guide

RMX 2000/4000 MPMx Migration Procedure

Written By: Andrew Bookholt

Replacing a Disk Drive

Dell EMC PowerVault MD3460 Storage Arrays

Acer Aspire 5100 Motherboard Replacement

Installation & Replacement

Dell Precision Workstation T7610 Owner's Manual

Removing and Replacing Chassis Components

Megatouch FORCE Monitor Chassis Board Replacement

Quantum DXi4700 Capacity Upgrade Guide

Mac mini Mid 2011 Hard Drive Replacement

Upgrade & Replacement

RMX 2000/4000 MPMx Migration Procedure

Medion Akoya MD Heat Sink

Replacing an Advanced Power and Cooling (APC) Unit

Product End-of-Life Disassembly Instructions

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Dell Precision M4600 Owner's Manual

Chassis (FRU) Replacement Guide

Samsung Galaxy S10 Motherboard

Managing Individual Components

Dell Precision Tower 7910 Owner's Manual

0. Silicon Graphics O2 and Silicon Graphics Octane R12000 CPU Upgrade Information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

HP Compaq 6730b Display Replacement

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Maintaining the ERX System

A5000 2Mb RAM Upgrade Fitting Instructions

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Sony Xperia XZ Premium Motherboard Replacement

Installing a Network Module

Installing a Network Module

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Dell Inspiron N5110 Service Manual

HP Pavilion dv7-6c90us Cooling fan Replacement

Chapter 4 Replacement Procedures

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Hardware Replacement Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

SCv3000 and SCv3020 Storage System. Owner s Manual

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Dell Latitude 14 Rugged Extreme 7404 Owner's Manual

Installing the Server into a Rack

Replacement Instructions

Acer Aspire 5742 Motherboard Replacement

IBM. Rack Installation Instructions

4.1 General. 4 Replacement Procedures

Acer Aspire 5742 Screen Assembly

Rack Installation Instructions

Transcription:

Central Processing Unit (CPU) Replacement Written By: Dozuki System 2018 gunnerautomotive.dozuki.com/ Page 1 of 17

INTRODUCTION OdXAkjljPNWbtqrS.pdf TOOLS: test (1) 7.5 " Machinist's Scale (1) 2018 gunnerautomotive.dozuki.com/ Page 2 of 17

Step 1 20 Seconds The server can be powered off remotely or on the hardware itself. Remote Power Down: Login to the server to power it off. shutdown -h now;exit Hardware Power Down: Press and hold the power switch for at least three seconds, as annotated. 2018 gunnerautomotive.dozuki.com/ Page 3 of 17

Step 2 Disconnect the 10G SFP+ Cable Disconnect the 10G SFP+ cable from the network interface controller. Use the pull-tab to disconnect the cable. Step 3 Remove the Server from the Rack Grasp the server as shown. Pull the retention plunger upwards. Begin sliding the server out of the rack. 2018 gunnerautomotive.dozuki.com/ Page 4 of 17

Step 4 Disconnect the Ethernet Cable Disconnect the Ethernet cable from the server. Press the tab on the end of the cable to release it. Step 5 Remove the Server Counter the weight of the server, as shown. Completely remove the server from the rack. 2018 gunnerautomotive.dozuki.com/ Page 5 of 17

Step 6 Engage the server lid, as shown. Push the lid towards the rear of the server. Lift the cover. Step 7 The heatsink may be hot. Loosen four screws. Select screws in a diagonal fashion. To loosen, use about two screwdriver rotations. 2018 gunnerautomotive.dozuki.com/ Page 6 of 17

Step 8 Continue to unscrew the screws holding the heat sink to the CPU until you can remove it. Step 9 Grab the heatsink as shown. Lift the heatsink off the CPU. 2018 gunnerautomotive.dozuki.com/ Page 7 of 17

Central Processing Unit (CPU) Replacement Release: v1.0-2018-10-08 Step 10 Grab the right CPU socket retention lever, as shown. Press the lever down and away from the CPU. The CPU socket retention lever is spring loaded. Keep pressure on the lever as it lifts. Step 11 Release the left lever. 2018 gunnerautomotive.dozuki.com/ Page 8 of 17

Central Processing Unit (CPU) Replacement Release: v1.0-2018-10-08 Step 12 Grab the CPU, as shown. Lift the CPU. Step 13 Engage the CPU retention housing, as shown. 2018 gunnerautomotive.dozuki.com/ Page 9 of 17

Step 14 Obtain an isopropyl alcohol cloth. Hold the CPU by its edges. The CPU may have a blue shroud. If so, hold it by the shroud. Step 15 Continue wiping the CPU with the alcohol-soaked cloth to remove the thermal compound. Multiple passes may be needed to completely remove all of the thermal compound. 2018 gunnerautomotive.dozuki.com/ Page 10 of 17

Step 16 Obtain a heatsink stencil. Seat the stencil on the bottom of the heatsink (as shown). Seating the stencil may require some force. Step 17 Apply thermal compound, as shown. 2018 gunnerautomotive.dozuki.com/ Page 11 of 17

Step 18 Lift the stencil off of the heatsink. The stencil may require some force to lift. Step 19 Align the arrow printed on the CPU so that it matches the arrow on the CPU socket gate. Place CPU in socket, and close the socket gate. Socket gate close process is opposite of removal. 2018 gunnerautomotive.dozuki.com/ Page 12 of 17

Step 20 Lower heatsink onto the CPU. Visually align the heatsink while lowering. Step 21 Tighten (4) screws. This process is opposite of removing the heatsink. It is necessary to apply pressure to the heatsink while tightening (4) screws. Further installation process is opposite of removal. 2018 gunnerautomotive.dozuki.com/ Page 13 of 17

Step 22 Install the lid on the server. The installation process is opposite of the removal process. Step 23 Slide the server back into the rack. Lift the green retention pin to clear the chassis. Connect all previously disconnected peripheral cables. Slide the server until the green retention pin snaps downwards, locking the server. Press the power button. 2018 gunnerautomotive.dozuki.com/ Page 14 of 17

Step 24 Slide the Server into the Rack Slide the server into the rack. The retention plunger does not need to be pulled upward during installation. The server is secure when the retention plunger snaps shut. Step 25 Connect the 10G SFP+ Cable Connect the 10G SFP+ cable into the network interface controller. 2018 gunnerautomotive.dozuki.com/ Page 15 of 17

Step 26 Connect the Ethernet Cable Connect the Ethernet cable to the server. Step 27 Press the power button. This work is licensed under a Creative Commons Attribution 4.0 International License. This document was last generated on 2018-10-11 10:32:00 PM. 2018 gunnerautomotive.dozuki.com/ Page 16 of 17

2018 gunnerautomotive.dozuki.com/ Page 17 of 17