RS-FS-N01 Wind speed transmitter user's Guide (485type)

Similar documents
RS-FX-N01 wind transmitter user's Guide (485type)

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Carbon Monoxide Sensor - ModBus

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

RS-WS-N01-TR Soil moisture temperature operation instruction (Type 485)

Flex Series User Guide

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

TRANSDUCER T4311, T4411

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Metal Debris Sensor Manual. Index. 1. Brief Introduction. 2. Main Technical Parameters

PDW30 Point-To-Point Wireless Bridge

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

RXTP ROOM TEMPERATURE

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

T2314, T2414. Instruction Manual

Copyright: December 2017 Nidec Issue: E

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

DC BRUSHLESS MOTOR CONTROLLER BLSD-20/BLSD-50

T2314, T2414. Instruction Manual

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485

Golander Peristaltic Pump MODBUS Communication Instruction

ENVIRONMENTAL MONITORING & CONTROL

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Interface Module XC Modbus Protocol Converter / User Manual

Zone Pressure Touch Sensor - Standard Range

Environdata FA ma Converter Guide

Temperature and humidity module DHT11 Product Manual

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Analog signal to RS485 or RS232 Converter, A/D Converter

Suitable for detecting transparent films or transparent bottles

ENVIRONMENTAL MONITORING & CONTROL

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

Signal Isolators & Conditioners

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

Signal Isolators & Conditioners

Linear Position Transducer HLT 1000-R2

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

1. Introduction. 2. Installation MODBUS INTERFACE

HD B. [ GB ] Precision Barometer

E2Q4 Square Proximity Sensor

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

SUN KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Hello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with ModBus RTU Communication Protocol.

Inclinometer. 4-20mA and RS232

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

Screw. Nut Guide. Features

RS485 MODBUS Module 6RO

KTA-250 Anemometer Alarm Card

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

AUD-340 Installation Guide

RTD Temperature acquisition converter WJ25

PSM-2 POWER SUPPLY MODULE INSTRUCTIONS

ETT 312 Build-In Touch Terminal

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Black Body Calibration Source User Manual

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

TMT470L Temperature Transmitter

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

COGNEX. Checker SensorView. Quick Reference Guide

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

MU110-6U. Analog output module 6 channel. User guide

AB300-Series Automated Filter Wheels

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

IFC 100 Supplementary instructions

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Lightning Stitch Assembly

mbc082 Bus Converter

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

Removal and Installation8

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Signal Isolators & Conditioners

Zone Pressure Touch (ZPT) Sensor - Standard Range

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

SGJ Cable Actuated Sensor Industrial CANBus J1939

E105 1/2-ATR Short Fan cooled VME Enclosure

8000 Sports Scoreboards

Transcription:

RS-FS-N01 Wind speed transmitter user's Guide (485type) Issue: V1.0 1

2

Context 1. Introduction... 4 2. Installation instructions...5 3. Configure the software installation and use... 6 4. Communication Protocol...7 5. Common Problems and Solutions... 9 6. Contact... 10 7. Document History... 10 8. Dimensions... 10 3

1. Introduction 1.1 Product Overview RS-FS-N01 wind speed transmitter, compact and lightweight, easy to carry and assemble, design cups can be efficiently obtain information about the wind speed, high-quality aluminum alloy housing, external spray plating process, has good anti-corrosion, anti- Erosion and other characteristics, to ensure long-term use of the transmitter without rust phenomenon, at the same time with the internal smooth bearing system to ensure the accuracy of information collection. Is widely used in greenhouse, environmental protection, weather stations, ships, docks, breeding and other environmental wind speed measurement. 1.2 Features Range: 0-30m / s, the resolution of 0.1m / s Anti - electromagnetic interference treatment Using the bottom of the outlet way, completely Du air plug rubber pad aging problem, long-term use is still waterproof The use of high-performance imported bearings, rotating resistance is small, accurate measurement Aluminum case, mechanical strength, high hardness, corrosion resistance, long-term use in outdoor rust Equipment structure and weight have been carefully designed and distributed, the inertia is small, responsive ModBus-RTU standard communication protocol, easy access, 1.3 Main Specifications DC power supply (default) Transmitter circuit operating temperature 10 ~ 30V DC -20 ~+60, 0 % RH ~ 80% RH 485 (modbus) protocol Baud Rate: 2400, 4800 (default), 9600 Communication Interface Data bit length: 8 Parity mode: none Stop bit length: 1 4

The default ModBus Address: 1 Support Function : 03 parameter settings Resolution Measuring range Be configured with software provided by the configuration 485 0.1 m / s 0 ~ 30m / s Dynamic Response Time 0.5s Start the wind speed 0.2m / s 2. Installation instructions 2.1 Equipment installation check Equipment List: transmitter equipment 1 four mounting screws certificate, warranty card, service card, etc. 12V / 2A 1 water supply station (optional) USB to 485 (optional) 485 terminating resistor (optional) 2.2 Interface Description Wide voltage power input 10 ~ 30 V can. Note that the signal line 485 when the terminal A \ B two lines can not be reversed, the bus between multiple devices must not conflict. 2.3 Electrical wiring Electricity source Line color brown black Description A positive power supply (10 ~ 30 V DC) Negative power supply through letter yellow 485 -A blue 485 -B 5

2.4 Description field wiring When a plurality of types of devices 485 connected to the same bus, the field wiring have certain requirements, refer to the specific data packet "485 field wiring device manual." 2.5 Installation Using mounting flange, threaded flange connector tube so that the lower portion of the wind speed sensor is firmly fixed on the flange, the chassis Ø65mm, open Ø6mm four mounting holes are circumferentially Ø47.1mmusing only bolts to securely in the bracket On the whole set of instruments, to maintain the best level, to ensure the accuracy of wind speed data, flange connection easy to use, able to withstand greater pressure. 2.6 Considerations 1. Never disassemble, but can not touch the sensor core, so as to avoid damage to the product. 2. The device as far away from the interference power, in order to avoid inaccuracies in the measurement, such as inverter, motor, installation, disassembly must disconnect the power transmitter into the water cut-off can lead to irreversible changes in the transmitter. 3. Prevention of chemicals, oil, dust and other directly against the sensor, not the condensation, long-term use in extreme temperatures to prevent thermal shock. 3. Configure the software installation and use 3.1 Software Selection Open the data package, select "Debug Software" --- "485 parameter configuration software" to find Open it. 3.2 parameter settings 1, select the correct COM port ( "My Computer - Properties - Device Manager - Port" inside view COM port), a figure below lists several different names drive 485 converter. 6

2, just take a single piece of equipment and power-up, click on the software testing baud rate, the software will test the current baud rate and device, the default baud rate is 4800bit / s, the default is0x01. 3, the needs to be modified according to the use and the baud rate, and can query the current state devices. 4, if the test is unsuccessful, recheck the wiring and equipment 485 driver installation. 4. Communication Protocol 7

4.1 The basic parameters of Communications Manual wind speed transmitter (485 type) Ed 8-bit binary Data bits 8 Parity bit no Stop bit 1 Error checking CRC (cyclic redundancy ) 2400bit / s, 4800bit / s, 9600 bit / s can be set, the default setting Baud rate is 48 00bit / s 4.2 Frame format definition data Using M odbus - RTU communication protocol, in the following format: Initial structure 4 byte time = 1 byte function = 1 byte Data area = N bytes Error checking = 16-bit CRC End structure 4 byte time Address : for the of the transmitter, the communication network is the only (factory default 0x01). Function Code: The host command functions such directions, the transmitter has used only the function 0x03 (read data register). Data area: data area is the specific communication data, note data of 16bits endian! CRC : two-byte checksum. Host query frame structure: function Register start Register Check Check length low high 1 byte 1 byte 2 bytes 2 bytes 1 byte 1 byte Slave Answer Frame Structure: function Valid bytes area Data Second data area The first data region N Check 8

1 byte 1 byte 1 byte 2 bytes 2 bytes 2 bytes 2 bytes 4.3 Register Address Register PLC or content operating configuration 0000 H 40001 Instantaneous wind speed Upload the data to the true value 10 times 4.4 protocol examples and explanation Read only Example: reading device PM values of 0x01 Inquiry frame: function Start Data Check Check length low high 0x 01 0x0 3 0x00 0x00 0x00 0x0 1 0x 84 0x 0 A Answer frame: (E.g., to read the current wind speed 8.6m / s) function Returns the number of valid bytes Current wind speed values Check low Check high 0x 01 0x0 3 0x0 2 0x0 0 0x 56 0x 38 0x 7A Wind speed calculation: Current wind speed: 0056 H (hexadecimal) = 86 => Winds = 8.6m / s 5. Common Problems and Solutions 5.1 device can not connect to a PLC or PC possible reason: 1) computer has multiple COM ports, port selection is not correct. 2) device error, or there is a duplicate device (factory default all 1). 3) The baud rate, parity, data bits, stop bits error. 4) The master polling interval and response wait time is too short, it is required more than 200ms provided. 9

5) 485 has turned off, or A, B line reversed. 6) the number of devices or the wiring too long, to be near the power supply, plus booster 485, while increasing 120 Ω termination resistor. 7) USB drive switch 485 is not installed or damaged. 8) equipment damage. 6. Contact Post :250101 Tel:+86-531-58720832 Fax:+86-531-67805165 Website : 7. Document History V1.0 documents created. 8. Dimensions 10

11