SIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation

Similar documents
Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Electronic Temperature Controller. Instruction Manual Version

MINI MCR-SL-MUX-V8-FLK 16

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

PHOENIX CONTACT - 05/2007

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

INSTALLATION GUIDE Ultrasonic Sensors Series UFP

SCHMIDT Programming Tool SS 20.4xx Instructions for Use

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

Operating instructions. Standstill monitor A / / 2011

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Stepper motor driver HEM-545 last change:

Type ME43. Quickstart

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

Flow Sensor SONOFLOW CO.55

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

INSTALLATION GUIDE Ultrasonic Sensors Series UPA

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

MDM 011-Z1 Regen Resistor

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

USB I/O-CARD WITH 32 INPUTS

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PHOENIX CONTACT - 01/2008

Installation manual plugs and connectors with screw connection (16/32 A)

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

OPERATING INSTRUCTIONS

R&S ZN-Z15x Calibration Units User Manual

MATRIX LED LED User Manual Please read the instructions carefully before use

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

micromax R Getting Started Guide

SINCOS. Linear Stepper Motor Power Stage. Manual 2066-A006 GB

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

SMART-e Document Rev1

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Assembly Instructions scancontrol 2700/2750 (500)

B63/ NS MS. EtherNet/IP LINK

R&S ZN-Z5x Calibration Units User Manual

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

to 12a Added Standard and Electrical requirements for UL table 1.1

Installation and Maintenance

Temposonics Magnetostrictive Linear Position Sensors

MCU-9201MT22 venetian blind controller

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Stepper motor driver Tiny-Step II Last change:

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

GV204 Impulse Splitter for Incremental Encoders

SeriBox. antrax Datentechnik GmbH

I/O module, analogue outputs and universal inputs

USBoard. Operating Manual. Version November USBoard-OperatingManual Neobotix GmbH all rights reserved 1 of 25

Operating Instructions ND 287

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

DP500IP 1AC/ DP500IP 3AC Manual

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

OPT2011. High-performance distance sensor. Operating Instructions

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

IC Scanner ICS 105. User manual. Copyright November 2013 LANGER EMV-Technik GmbH IC Scanner ICS 105/1216

BP16 Backplane for MAL Amplifiers

Installation instructions Ethernet switch EC / / 2011

Hardware Manual RM CANview

EPS 06 in rear housing type A1

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

CP 64 BD15 CP 64 PD15

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Operating Instructions Differential Pressure Transducer PS27

EATON 5S 850/1200/1600

Cube LAN Gateway. Operating manual BC-LGW-O-TW

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Channel Switch CS. General Operating, Maintenance and Installation Manual

PCAN-B10011S Bus Converter High-speed CAN to Truck-Trailer CAN. User Manual V2.0.0

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

modunet292: novanet-ethernet interface

PHOENIX CONTACT - 07/2006

MSI-RM2 Safety Relays


Operating Manual. English. Digital-Analog Converter DACON8-UMB.

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

Operating instructions RFID evaluation unit DTE / / 2016

PTZ Control VMC Joystick

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

* _1118* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Interface Adapter USM21A

SCHMIDT Sensor interface PROFIBUS Instructions for use

Operation Manual for Sensor Interface LCV-USB2

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Transcription:

USER MANUAL ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation

2 Index 1. Features and Applications... 3 1.1 Functions of the ADJUSTMENT TOOL... 3 1.2 Dynamic Offset and Amplitude Control (Online Compensation)... 3 1.3 Scope of Delivery... 3 1.4 Suitable Encoders... 3 2. Safety... 4 2.1 General Information... 4 2.2 Notes on Legal Requirements... 5 2.3 Notes on Transport, Storage and Handling... 5 2.4 Notes on Operation... 5 3. EPIFLEX Software... 6 3.1 EPIFLEX - Installation Guide... 6 3.2 EPIFLEX - Range of Functions... 7 3.3 Advanced Software Settings... 10 4. Wiring Diagram... 11 4.1 Connecting Variants of the Diagnostic Connector... 11 4.2 Connection of the Encoder to the ADJUSTMENT TOOL Hardware... 12 5. Electronic Signal Adjustment... 13 5.1 Hints to the Automatic Signal Adjustment... 14 6. Interface Settings... 15 7. Pin Assignment of the Diagnostic Connector... 15 8. Troubleshooting... 16 9. Ordering Information... 17

3 1. Features and Applications Before delivery the encoders from NUMERIK JENA will be tested and electronically adjusted under ideal mounting conditions. Furthermore, the sensor modules offer the possibility of an electronic signal adjustment after the mounting into the application. This allows the user to optimize the encoder signals regarding to the mechanical mounting conditions (tolerances). The ADJUSTMENT TOOL and the related EPIFLEX software was designed to simplify and make the signal adjustment more effective. 1.1 Functions of the ADJUSTMENT TOOL Automatic signal adjustment / optimization and programming of the sensor module Display of the sinusoidal counting signals with amplitude, offset and phase position Enables evaluation of the mechanical mounting conditions Display and adjustment of the index signal 1.2 Dynamic Offset and Amplitude Control (Online Compensation) The encoders of NUMERIK JENA are equipped with a dynamic amplitude and offset control (online compensation). The analog diode signals will be corrected to their nominal values in real time. This reduces measuring errors caused by contamination of the scale tape as well as from inaccuracies in the guide way. The phase position between the sine and cosine signals and the position of the index signal are not influenced by the online compensation. With help of the EPIFLEX Software the preadjusted nominal values of the online compensation can be influenced (see chapter 3). 1.3 Scope of Delivery ADJUSTMENT TOOL black box Diagnostic cable to connect the measuring system USB cable to connect a PC USB - D-SUB - adapter cable (15-pin) Exchangeable 8-pin plug connectors 1.4 Suitable Encoders The ADJUSTMENT TOOL is suitable for the following NUMERIK JENA - products: LIA Series LIK Series Kit L2 / L4 RIK 4 Kit R4 RIA Series

4 2. Safety 2.1 General Information Make sure to familiarize yourself thoroughly with the contents of the user manuals and data sheets before installing and starting up the encoder! The encoders as well as the accessory are guaranteed to function if the mounting and operating conditions are maintained as stated in the respective user manuals and data sheets. NUMERIK JENA GmbH is not liable for damages caused by unauthorized handling of the encoders and the accessory. Any unauthorized handling leads to forfeiture of all warranty claims! Connect NUMERIK JENA encoders only to subsequent electronics whose power supply is generated from PELV systems (EN 50178). NUMERIK JENA encoders fulfill the requirements of standard IEC 61010-1 only if the power is supplied from a secondary circuit with current limitation as per IEC 61010 3rd Ed., Section 9.4 or with power limitation as per IEC 60950-1 2nd Ed., Section 2.5 or from a Class 2 secondary circuit as specified in UL1310.* The stated mounting tolerances must be maintained in order to achieve the accuracies listed in the specifications! If the machine tolerances exceed the tolerances stated in the user manuals or data sheets, malfunctions during operation can occur and lead to measuring errors. NUMERIK JENA GmbH does not assume any liability for any damages or operating errors caused by incorrect mounting and/or startup operations. Please consider user manuals, data sheets and safety instructions of devices from other manufacturer which will be used in combination with encoders and accessories from NUMERIK JENA to ensure a reliable operation. Please pay attention to the safety instructions and warning symbols in the user manuals and data sheets from NUMERIK JENA!! Danger to the device or to the function of the device! Pull the plug! Highly inflammable! * In place of IEC 61010-1 3rdEd., Section 9.4, the corresponding sections of standards DIN EN 61010-1, EN61010-1, UL 61010-1 and CAN/CSA-C22.2 No. 61010-1 can be applied and in place of IEC 60950-1 2nd Ed., Section 2.5 the corresponding sections of standards DIN EN60950-1, EN60950-1, UL60950-1, CAN/CSA-C22.2 No. 60950-1 can be applied.

5 2.2 Notes on Legal Requirements The encoders and accessories from NUMERIK JENA conform to EC standards and carry the CE mark. The encoders and accessories from NUMERIK JENA fulfill the requirements of the (German) Product Safety Act (ProdSG) from November 8 th, 2011. Standards (ISO, EN, etc.) apply only where explicitly stated in the respective user manual or data sheet of the product. This user manual supersedes all previous editions, which thereby become invalid. The basis for ordering from NUMERIK JENA is always the valid edition of the user manual or data sheet at that time when the contract is made. 2.3 Notes on Transport, Storage and Handling The products from NUMERIK JENA must be transported and stored in the original packaging only! 2.4 Notes on Operation Do not connect or disconnect plugs if the power is on!! The encoders and accessories from NUMERIK JENA must be operated with the supply voltage stated in the respective user manual or data sheet only. Comply with applicable PIN assignment if auxiliary electronic units (e.g. controller or display) are connected!

6 3. EPIFLEX Software The EPIFLEX software was especially designed for the ADJUSTMENT TOOL. It offers the user versatile possibilities to bring the encoder into service. It also allows the user to display the sensor signals and evaluate them without using an oscilloscope or other expensive hardware. Furthermore it is possible to program respectively optimize the encoder to the existing mounting conditions automatically. The EPIFLEX software is available for free via download on the NUMERIK JENA website under www.numerikjena.de. Furthermore, one can order the software with an optional USB flash drive. The EPIFLEX software is suitable for the following operating systems: Windows 7 / 8 (32 or 64 bit) 3.1 EPIFLEX - Installation Guide Unzip the downloaded installation file or connect the optional USB flash drive to your PC. Run the setup file and follow the instructions shown in the installation window. Image 1 For software updates please visit our website. In our download portal you will always find the latest version for free. We provide these software packages usually as a zipped folder. Please unzip this folder after the download, run the setup file and follow the installation instructions. If an older software version is installed, it is not necessary to uninstall it before. ATTENTION! Please install the software first, only then connect the ADJUSTMENT TOOL to your PC!

7 3.2 EPIFLEX - Range of Functions 1 2 3 4 5 6 7 8 9 Image 2 1 Opens a file with saved parameter 2 Saves current parameters to a file 3 Reads the data from the connected sensor module 4 Saves the current parameters to the connected sensor module permanently 5 Undoes the last changed settings after connecting / saving 6 Window for counting signals Green area: shows the tolerance limits Red circle: shows the signal optimum Blue circle: shows the actual signal as a Lissajous figure 7 Starts the automatic signal adjustment 8 Button for the online compensation (ON / OFF) 9 Sensor number

8 Index Signal Window 10 11 12 13 14 15 Image 3 10 Signal window for the index impulse Green signal period: Sine signal Red signal period: Cosine signal Blue signal: Index impulse 11 Controller for adjustment of the index Change of position 12 Controller for adjustment of the index Change of width 13 Drop-down menu for signal output (interface) 1 V PP (for sensor modules with and also without integrated signal interpolation) 3 V PP (for sensor modules with external interpolation electronics / PCB) 14 Controller to change the time base of the software oscilloscope 15 Readout for the time-based value

9 Adjustment - Tab With Adjustment - Tab it is possible to do a manual signal adjustment. The online compensation must be deactivated. The following parameter which have direct influence to the counting signals (Lissajous-figure) can be adjusted: LED current Sine offset Cosine offset Signal amplitude of the sine signals* Signal amplitude of the cosine signals Image 4 Online Compensation - Tab With help of the Online Compensation - Tab it is possible to influence the preadjusted nominal values of the online compensation. However, normally this is not necessary. The online compensation must be activated. The online compensation adjusts the amplitudes of the sine and cosine signals dynamically. For monitoring functions the range of adjustment of the sine and cosine amplitude parameters can be visualized by activating the option Update Controls. Because of a permanent data communication signal errors can occur. Therefore this option should not be activated permanently.* Image 5 Options - Tab The Options - Tab allows to activate or deactivate the error or monitoring signal (NAS). Furthermore the interface of the scanning head (1 V PP or RS 422), the speed index of the sensor module and the counting direction can be changed.* By using a RS 422 sensor w/o signal interpolation it is necessary to adjust the interface. Only then the counting signals can be displayed. If the automatic signal adjustment will be started this adjustment is not necessary. In this case the interface will be set automatically. Image 6 Among other things the Options - Tab displays ID and serial number of the sensor module.* * Encoders with external interpolation electronics or depending on the kind of the integrated sensor amplifier, these options will possibly not be supported.

10 3.3 Advanced Software Settings By using the key combination [Ctrl] + [Shift] + [S] an additional window for advanced settings will be shown. In the settings window one can activate or deactivate the following settings: Set Online Compensation after automatic adjustment Force 1V PP setting at start of automatic adjustment Restore interface setting after automatic adjustment Warn if adjustment is canceled Show Sum control in index signal window (restart of EPIFLEX 2015 is required) Language settings, automatic or manual (English / German) Image 7

11 4. Wiring Diagram The encoders from NUMERIK JENA have an 8-pin diagnostic connector for signal evaluation and for adjustment. Depending on the model, this connector is either in the scanning head (LIA 20 measuring systems only) or in the D-Sub connector. The code on the ID label indicates the location of the connector. ATTENTION! The power supply must be shut off when connecting or disconnecting the diagnostic connector! Connect the diagnostic connector to the diagnostic socket as shown in the graphics with the connecting variants. Please pay attention to the white marking on the diagnostic connector! For encoders with signal processing (interpolation) in the scanning head, the head s housing cover must be removed carefully. If the signal is processed in the connector, then the connector must be opened. 4.1 Connecting Variants of the Diagnostic Connector D-Sub Connector Scanning Head 1 2 Diagnostic Socket Connector PCB D-Sub Connector Scanning Head Diagnostic Socket Connector PCB: RS 422 with interpolation Please use diagnostic socket 2! Connector PCB: 1V PP or RS 422 without interpolation Scanning Head PCB (LIA 20) Connector PCB Diagnostic Socket Diagnostic Socket Scanning Head PCB (LIA 20) Scanning head PCB: RS 422 with interpolation Scanning head PCB: 1V PP or RS 422 without interpolation Image 8

12 4.2 Connection of the Encoder to the ADJUSTMENT TOOL Hardware D-Sub Connector Adapter Cable Connector PCB Diagnostic Socket D-Sub Connector Scanning Head or Diagnostic Socket Scanning Head PCB (LIA 20) PC USB USB USB Black Box Diagnostic Socket Image 9 ATTENTION! Please pay attention to the following during the signal adjustment: Any noise disturbances which are interfering with the measuring system can lead to incorrect signal settings. This will cause non-optimal signal parameters during function. During the signal adjustment the signals of the encoder should not be used to control the drive motor. Unintentional misadjustments could cause wrong signal values in the controller and lead to malfunction of the drive system. The stage should be moved without motorized drive during the signal adjustment. If a motorized drive is necessary, a manual operation has to be used. Encoder system, stage, ADJUSTMENT TOOL and controller must have the same ground and earth potential. For safety purposes use the included USB - D-SUB - adapter cable during the adjustment to supply the measuring system with power over your PC, not your controller! If you are not in possession of the USB - D-SUB - adapter cable, you can order it separately from NUMERIK JENA.

13 5. Electronic Signal Adjustment With the EPIFLEX software you are able to adjust signal influencing parameters manually (see page 7). Ocassionally, that can be inconvenient, time-consuming and imprecise. Therefore, the EPIFLEX software provides an automatic adjustment function which allows you to adjust and optimize all parameter settings automatically very fast as well as easy. To start the automatic adjustment please proceed as described in the following: 1. 2. 3. 4. 5. Click on the green Start - Button to start the automatic adjustment procedure. Subsequently a status window appears. Please follow the instructions displayed in the status window! Move the read head to the scale back and forth. In doing so it is important to cross a reference mark to ensure that the system can also adjust this parameter correctly. Please cross the reference mark in both directions! At the bottom of the main window a green progress bar will be displayed. This bar shows the progress of the adjustment. The status window displays the progress of each adjusted parameter. If the adjustment is done, please click on the Save - Button. By doing so the new adjusted parameter will be saved to the sensor module. Image 10 ATTENTION! Before you start the electronic adjustment please pay attention to any contamination on the scale. This can affect the adjustment process negatively. Clean the surface of the scale with a soft microfibre cloth and acetone if necessary.

14 5.1 Hints to the Automatic Signal Adjustment The movement of the measuring system during the automatic signal adjustment should be as steady as possible. In the window for the index impulse 2 to 6 signal periods should be displayed. Otherwise adjust the movement speed or regulate the time base of the software oscilloscope, please. If the status window displays the message Missing signals or too less/many periods to calculate the parameters, it is an indication that the movement of the measuring system is too slow or too fast. In this case please adjust the movement speed in an appropriate way. Furthermore, you should pay attention that you cross the reference mark during the movement. If you get error messages in the status window after the adjustment it may have several reasons. In this case please start the automatic adjustment procedure again to verify a legitimate failure. Additionally, please pay attention to our mounting instructions in the data sheet of the measuring system. Often, problems occur because of a transgression of the mechanical mounting tolerances. In chapter 8 we have compiled some potential error causes. If these error causes do not apply to your application, please contact us. Image 11 If the automatic adjustment procedure is finished successfully, you can use the encoder at full capability. If you change something regarding your mounting conditions afterwards, e.g. disassembling and renewed assembling of the scanning head, it is recommended to do the automatic adjustment again.

15 6. Interface Settings The EPIFLEX software recognizes the output interface of the sensor automatically during startup of the automatic signal adjustment. If the EPIFLEX software is used to check the sensor signals only, possibly an interface setting must be done (see page 6 and 7). Following settings are valid: Signal processing Interface Output interface 1 V PP 1 V PP Scanning head 1 V PP / 3 V PP RS 422 with interpolation RS 422 RS 422 with interpolation 1 V PP 1 V PP Connector 3 V PP RS 422 with interpolation RS 422 RS 422 with interpolation Chart 1 7. Pin Assignment of the Diagnostic Connector Pin Signal Description 1 SCL Serial Clock (white marking on diagnostic connector) 2 SDA Serial Data 3 RI Index rough impulse 4 U m Middle voltage 5 A+ Sine+ 6 B+ Cosine+ 7 CS not used 8 GND GND Chart 2

16 8. Troubleshooting We have listed some possible error causes and solutions below. If this is not helpful, please contact the technical support of NUMERIK JENA GmbH or one of our authorized representations. You will find respective contact data on the NUMERIK JENA webside www.numerikjena.de. Error Possible cause Solution Incorrect sensor values Sensor data deleted. Everything set to standard values (0 or 255) Incorrect sensor settings Please contact NUMERIK JENA Load the sensor values again Amplitude or offset cannot be changed with the controllers Online compensation is active Switch off the online compensation Amplitude or offset are not changed by mechanical adjustment Online compensation is active Switch off the online compensation No reference mark detected Mounting of the scanning head outside permitted tolerances Position and size of the rough pulse outside permitted tolerances Check the mounting conditions Set the rough pulse correctly Double index impulse Mounting of the scanning head outside permitted tolerances Rough pulse too wide Check the mounting conditions Set the rough pulse correctly No rough index pulse visible on the oscilloscope Position value greater than Width Position must be less than Width Chart 3

17 9. Ordering Information Name Scope of delivery / Description Order-no. ADJUSTMENT TOOL ADJUSTMENT TOOL black box Diagnostic cable to connect the measuring system USB cable to connect a PC USB - D-SUB - adapter cable (15-pin) Exchangeable 8-pin plug connectors 344220-33 Optional Single Components Name Description Order-no. EPIFLEX software - USB flash drive External flash drive with saved EPIFLEX software 686802-02 USB - D-SUB - adapter cable (15-pin) to supply the measuring system with voltage via PC 341693-0M 8-pin plug connector to connect the diagnostic cable with the diagnostic socket 348958-01 USB - D-SUB - adapter cable (15-pin) Required components (not included): PC with OS Windows 7 / 8 (32 or 64 bit)

NUMERIK JENA GmbH Im Semmicht 4 07751 Jena Germany Phone: +49 3641 4728-0 Fax: +49 3641 4728-202 E-Mail: info@numerikjena.de www.numerikjena.de Subject to change without prior notice. version 03_3 2016 & NUMERIK JENA GmbH