Model Number Structure

Similar documents
Model Number Structure

Model Number Structure

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Solid State Relays with Failure Detection Function

S82S (3/7.5-W Models)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Model Number Structure

Number of input channels

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Connecting Sockets, Mounting Brackets, DIN Rails

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model A7BS

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

CSM_PYF S/P2RF- -S_DS_E_2_5

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Ordering Information. Interface Converter K3SC. List of Models

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

E4C-UDA CSM_E4C-UDA_DS_E_12_2

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

Model NPN output PNP output Standard. configuration

Model Number Structure

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Model Number Structure

Model Number Structure

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Model Number Structure

Electroformed Probe Pins XP3A

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model Number Structure

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Indicator (Square) Ultra Bright LED Type

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

Ordering Information. Interface Converter K3SC. List of Models

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Conductive Level Controller

Model Number Structure

Dimension A. Dimension B

NX-TS. NX-series Temperature Input Unit

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Model Number Structure

NJ-Series Power Supply Unit NJ-PA/PD

Model Number Structure

E2K-X4ME1 2M E2K-X4ME2 2M

NPN output. 200 mm. Type Cable length Model Remarks

M16-J M16-A M16-T

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

Indicator (Square) Ultra Bright LED Type

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Three-phase Phase-sequence Phase-loss Relay

NYM. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Smart Sensors with Ultra-High-Speed Color CCD Cameras mm to mm (variable) mm to mm (variable)

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Handheld Reader Writer

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

NX-DA CSM_NX-DA_DS_E_3_1

Intelligent Flag Amplifier

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

Knob-type Selector Switches

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

Single-phase Voltage Relay

D4GS-N CSM_D4GS-N_DS_E_7_4

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Transcription:

Digital Panel Meter CSM DS_E_4_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display with 14.2-mm-high LEDs. Detects and displays root-mean-square value of half-wave rectified current. Confirms to EMC standards EN61010-1 (IEC61010-1). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Note: This Panel Meter does not support scaling. Model Number Legend - 1 2 3 4 1, 2. Input Code 3. Series No. V5: 0 to 199.9 mv 1: Current series V6: 0 to 1.999 V 4. Supply Voltage V7: 0 to 19.99 V 4: 100 to 120 VAC V8: 0 to 199.9 V 5: 200 to 240 VAC V9: 0 to 400 V A6: 0 to 1.999 ma A7: 0 to 19.99 ma A8: 0 to 199.9 ma A9: 0 to 1.999 A Ordering Information List of Models Models with Line Monitor Range Measuring ranges Supply voltage 100 to 120 VAC 200 to 240 VAC AC voltage 0 to 199.9 V -V814 -V815 0 to 400 V -V914 -V915 1

Models with Signal Monitor Range Measuring ranges Supply voltage 100 to 120 VAC 200 to 240 VAC AC voltage 0 to 199.9 mv -V514 -V515 0 to 1.999 V -V614 -V615 0 to 19.99 V -V714 -V715 AC current 0 to 1.999 ma -A614 -A615 0 to 19.99 ma -A714 -A715 0 to 199.9 ma -A814 -A815 0 to 1.999 A -A914 -A915 Note: The -V8@@ and -V9@@ do not conform to CE marking standards. Accessories (Order Separately) Name Appearance Model Water-resistive Soft Front Cover K32-L49SC Terminal Cover K32-L49TC Watertight Cover Y92A-49N Note: 1. Use the Mounting Bracket included with the for mounting. 2. The Terminal Cover is used for finger protection. It has no relation to water resistance. 2

Specifications Ratings Supply voltage 100 to 120 VAC (50/60 Hz); 200 to 240 VAC (50/60 Hz) Operating voltage range 15% to +10% of supply voltage Power consumption 4 VA (at max. load) Insulation resistance 10 MΩ min. (at 500 VDC) between external terminal and case Dielectric strength 2,000 VAC min. for 1 min between input terminal and power supply 2,000 VAC min. for 1 min between external terminal and case Noise immunity ±1,500 V on power supply terminals in normal or common mode Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions Shock resistance Malfunction: 98 m/s 2 for 3 times each in 6 directions Destruction: 294 m/s 2 for 3 times each in 6 directions Ambient temperature Operating: 10 to 55 C (with no icing) Storage: 20 to 65 C (with no icing) Ambient humidity Operating: 35% to 85% (with no condensation) Ambient operating atmosphere No corrosive gas EMC (EMI) EN61326+A1 Industry Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/-2 Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/-2 (EMS) EN61326+A1 Industry Immunity ESD: EN61000-4-2: 4 kv contact discharge (level 2) 8 kv air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz) (level 3) Immunity Fast Transient Noise: EN61000-4-4: 2 kv (power line) (level 3) Approved standard Note: The -V8@@ and -V9@@ do not conform to CE marking standards. Characteristics Immunity Burst Noise: 1 kv line to line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kv line to line 2 kv line to ground (power line) Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180, 100% (rated voltage) Conforms to EN61326+A1, EN61010-1 (IEC61010-1) Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted. Input signal AC voltage/current A/D conversion method Double integral method Root-mean-square value indication Root-mean-square value of half-wave rectified current detected Sampling period 2.5 times/s Display refresh period 2.5 times/s Max. displayed digits 3 1/2 digits (1999) Display 7-segment red LED Decimal point display position Selected with slide switch (see note 1) Overflow display Overflow: 1@@@ Zero suppression Not supported. External control Process value hold (terminals on rear panel short-circuited) Degree of protection Front panel: IEC IP51 (see note 2) Case: IEC IP20 Terminals: IEC IP00 Note: 1. Only for models with signal monitor. 2. IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive accessories. 3

Measuring Ranges Monitor Input range Measuring range Max. resolution Input impedance Accuracy Max. permissible load Line monitor AC voltage 0 to 199.9 V 100 mv 10 MΩ ±0.3%rdg ±1 digit (see note 1) Signal monitor Note: 1. With 100% input. ±0.3% FS±1 digit when the input is less than 35% FS. 2. The above accuracy is at an input frequency range of 40 Hz to 1 khz and an ambient temperature of 23±5 C. 3. A large error will result if a signal that is not a sine wave is used (e.g., a signal from thyristor control). 500 V 0 to 400 V 1 V 10 MΩ ±0.3%rdg ±1 digit 500 V AC voltage 0 to 199.9 mv 100 μv 10 MΩ ±0.3%rdg ±1 digit 250 V 0 to 1.999 V 1 mv 10 MΩ ±0.3%rdg ±1 digit 250 V 0 to 19.99 V 10 mv 1 MΩ ±0.3%rdg ±1 digit 250 V AC current 0 to 1.999 ma 1 μa 100 Ω ±0.5%rdg ±1 digit 50 ma 0 to 19.99 ma 10 μa 10 Ω ±0.5%rdg ±1 digit 150 ma 0 to 199.9 ma 100 μa 1 Ω ±0.5%rdg ±1 digit 500 ma 0 to 1.999 A 1 ma 0.1 Ω ±0.5%rdg ±1 digit 3 A Connections External Connections 1 2 3 4 5 6 7 8 9 AC signal input GND HOLD Unused AC power supply Note: Terminals 2 and 3 of the models are not internally insulated. Connect a relay with high contact reliability and insulation (with a minimum load current of 0.3 ma) or a photocoupler with high insulation (with a residual voltage of 1 V max. and a current leakage of 0.1 ma max.) to these terminals for external control. Nomenclature Display Unit name 10 3 10 2 10 1 No decimal point Select the decimal position with the slide switch under the cover on the front panel (signal monitor only). Remove the front panel by using a flat-blade screwdriver or your fingernail in the two notches at the bottom. Note: The decimal position cannot be changed for the -V81@ or -V91@. 4

Dimensions Note: All units are in millimeters unless otherwise indicated. Panel Cutouts 92 +0.8 0 98 92 45 +0.6 0 75 min. 48 43 120 min. Note: The values above are recommended values. Do not group-mount the meters at intervals less than the recommended ones. LED Indicator Size 96 3.5 66 The uses M3.5 terminals. 7.8 mm 14.2 mm Application Examples gh AC Voltage Measurement When voltage exceeding the maximum voltage in the standard range is measured (for example: more than 400 V), a divider or potential transformer (PT) is connected externally. Large AC Current Measurement When AC current exceeding 2 A is measured, a current transformer (CT) is connected externally. Input Digital panel meter Input Digital panel meter PT CT 5

Safety Precautions Refer to Safety Precautions for All Digital Panel Meters. Precautions for Safe Use The front panel cover is removed when setting the decimal point position or performing calibration. Do not, however, touch any parts other than the slide switches or adjustment knob or come close to any metal parts. Precautions for Correct Use Mounting Recommended panel thickness is 1 to 3.2 mm. Mount the Digital Panel Meter by attaching the mounting bracket supplied as an accessory from the rear of the Digital Panel Meter, hook the mounting bracket to the Digital Panel Meter securely, and tighten the mounting screws by turning them clockwise with a tightening torque of 5 kgf cm (0.49 N m). For dismounting, loosen the screws and widen the hooks. Always attach the Mounting Bracket before wiring the terminals. Also, always remove the wiring before removing the Mounting Bracket. Mount the Digital Panel Meter as horizontally as possible. Never use the Digital Panel Meter in locations where corrosive gas (particularly sulfide or ammonia gas) is generated. As much as possible avoid use of the Digital Panel Meter in a location subject to severe shock or vibration, excessive dust, or excessive moisture. Select a mounting location where the Digital Panel Meter can be used at an ambient operating temperature 10 to 55 C. No product is shipped with the unit label attached. Select a unit label from the sheet provided, and attach it to the Digital Panel Meter. Calibration Calibrate the Digital Panel Meter regularly so that the Digital Panel Meter can maintain processing accuracy. Use a standard signal generator with an accuracy of 99.99% min. for calibration. For the precise calibration methods, refer to the Instruction Sheet for the Digital Panel Meter. After the front panel cover is removed to calibrate the or set the decimal position, do not touch components other than the slide switch and calibration adjustor. Keep metal objects off the after the cover is removed, especially when power is turned on. Accessories (Order Separately) Water-resistive Soft Front Cover Before mounting the Digital Panel Meter to a panel, attach the waterresistive soft front cover and mounting bracket to the Digital Panel Meter properly so that the Digital Panel Meter will maintain IP51 water-resistive standards. Before you calibrate Digital Panel Meters, remove the water-resistive soft front cover. Refer to the operation manual included with the Digital Panel Meter for the calibration procedure. Soft Cover Mounting Bracket Note: Be sure to use the Water-resistive Soft Front Cover and mounting bracket together. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2014.2 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2014 All Right Reserved.