Symbio Microscope. L1500 Series. Biological Upright Compound Microscopes. Operating Manual

Similar documents
Polarization Microscope. Omano OM349P Series. User Guide

OMM200 and OMM200T. Metallurgical Microscope

M40 Microscope User s Manual

User Manual. Binocular Compound LED Microscope. MicroscopeNet.com

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

M20 Metallurgical Microscope User s Manual. Fein.

For documentation, both instruments are available with a trinocular head which permits mounting of a video or digital camera system.

Mi50 Inverted Microscope User s Manual. Fein.

Instruction Manual. B1 Series. Copyright 02/02 Motic Microscopes, European Division

BIOLOGICAL MICROSCOPE

Binocular Compound Microscope Instruction Manual

For documentation the instrument is available with a trinocular head which permits mounting of a video or digital camera system.

INSTRUCTION MANUAL POLARIZING & ORE MICROSCOPES. Polarizing Microscopes. Ore Microscopes. Model: NYMC62B00

LABOMED, INC. APPLICATION

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

Richter Optica. Instructions for Models: UX1B Binocular and UX1T Trinocular Laboratory and University Biological Microscope

Seilerscope COMPOUND MICROSCOPE USER S MANUAL

Fisher Scientific Microscopes

R40POL Microscope User s Manual

3025 MICROSCOPE SERIES INSTRUCTIONS

Compound Microscope Instruction Manual

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Operation Manual. VWR Inverted Microscope. (Version 1.0.0) VWR Inverted Microscope VWR Inverted Microscope.

M50 and M50RT Series. Brightfield / Darkfield Metallurgical Microscopes

Teaching Microscope Instruction Manual OMTM85 and OMTM85L

optech Reflected Metallurgical Microscope Model SM lnstruction Manual OPTICAL TECHNOLOGY

Innovative Solutions in Material Test Equipment

Instruction Manual. B3 Series. Copyright 02/02 Motic Microscopes, European Division

Operation Manual. for Micromas ter I Micros copes. T his manual covers catalog numbers : S 11031, S 11033, and S 11035

Comprehensive Scope 2. Instruction Manual T-19011C - Monocular T-19021C - Dual Viewing T-19031C - Binocular T-19041C - Trinocular

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

BINOCULAR MICROSCOPES

Richter Optica. Instructions for Model: MDS1 Compound Microscope

ACCURACY SIMPLICITY EFFICIENCY

User Manual. Trinocular Stereo Microscope

Compound microscopes KERN OBF-1 OBL-1

Use of the Binocular Microscope

Eco D-ELS-4 Stereo Microscope. Instruction Manual

Operation Manual (Version 1.0.0)

Transmission Polarizing Microscope OM239

BA210 BASIC BIOLOGICAL. Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

EXAMET-4 MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Delphi-X Observer HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECE(S) HEAD MULTIHEAD SYSTEM FACE-TO-FACE DUAL HEAD SYSTEM PRODUCT DATASHEET

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

MICROSCOPE USER MANUAL

M40 and M40RT Series. Metallurgical Microscopes

Swift SM100 Series Stereo Microscope

User Manual. Trinocular Stereo Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Richter Optica. Instructions for Model: HSX1 High School Microscope

Richter Optica. Instructions for Model F-1 Compound Microscope

Palomar. Metallurgical Microscopes. Palomar Metallurgical Microscopes

3002 MICROSCOPE SERIES. microscopes are engineered to the highest quality standards ACCU-SCOPE. Delivering Quality thru Vision

PF Series Fluorescence Microscope

Great Bay Community College Document Number: Corporate Drive Revision Number: 3

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

148 Series. User s Manual

INSTRUCTIONS FOR MODEL C-1028 COMPOUND MICROSCOPE

Polarizing Microscope LPM-A10. Features. Applications. Specifications

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, TX Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Microscopy Redefined. Fisher Scientific Premier Microscopes

EXAMET-5 MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

X-LED TM. B-350 Series B-350. Advanced biological microscopes for teachers. Advanced biological microscopes for teachers B-350

Lab 4 - The Microscope

OPTIKA EDUCATIONAL MICROSCOPES. ECOVISION SERIES - Entry-level biological microscopes for students page 5

Operation Manual (Version 1.0.0)

Optech microscopes. Science & Educational

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Microscopes. Passion for Science PAGE PAGE PAGE PAGE PAGE

Fein. RB50 Series Research Microscopes

POLARIZING MICROSCOPE LPM-A1 Series.

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Delphi-X Observer HIGHLIGHTS TECHNICAL SPECIFICATIONS EYEPIECES STANDARD HEAD FACE-TO-FACE DUAL HEAD SYSTEM ERGONOMIC TILTING HEAD MULTIHEAD SYSTEM

HumaScope Line. CoreLab DX. Affordable Microscopes Fitting to Your Needs. HumaScope Line

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

OPTIKA. INDUSTRY Series. Metallurgical and measuring microscopes. Metallurgical and measuring microscopes

INTRODUCTION - VetScan HDmicroscope

SM-6 Series. User s Manual

SeBa Digital Imaging Systems

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

BA210 Basic Biological Microscope

National Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210) INSTRUCTIONS FOR

Compound microscope KERN OBE-1

Leica BM E. Compound Microscope System Great discoveries begin with vision.

Lab 5 Microscopy. Introduction. Carrying the Microscope. Depth of Focus. Parts of the Compound Microscope. Magnification

OPTIKA. fluo Series Upright and inverted epi-fluorescence microscopes

OPTIKA. educational microscopes

available with b-350 series Advanced Biological Microscopes for Teachers 27

CCIS (Colour Corrected Infinity System) The microscope stand BA300

MANUAL Series ZOOM STEREO MICROSCOPE MANUAL

GX Microscopes. Biological Upright Compound Microscopes Range. Research Routine University Teaching. Digital. Hobbyists Students GXM L3200B

Sunny Instruments. E5 Series Biological Microscope

2014 EUROPE PRICE LIST EN ES DE BA310E SERIES. Canada China Germany Spain USA

Transcription:

Symbio Microscope L1500 Series Biological Upright Compound Microscopes Operating Manual 1

The GXM L1500 Series of biological microscopes are high quality instruments equipped with high grade, glass objectives in steel barrels which can be achromatic (model GXML1500A) or economic plan achromatic (model GXML1500B) and wide field eyepieces. They can be supplied with monocular, binocular or trinocular heads providing the observer with a bright, clear image and a wide field of view. These highly robust microscopes are suitable for scientific research, routine work in hospitals and government agencies and are especially popular as teaching tools in universities and colleges. SPECIFICATIONS 1.Eyepieces Type Magnification Focus(mm) Field(mm) Remark Wide field eyepiece 10X 25 φ18 Plan eyepiece 16X 15.6 φ11 Optional 2.Objectives Type W.D(mm) Magnification N.A Achromatic Semi-Plan Achromatic or Semi- Plan Achromatic 4X 0.1 37.4 23.1 10X 0.25 6.6 4.1 40X 0.65 0.64 0.6 100X(oil) 1.25 0.19 0.38 3.Total Magnification Total Objectives Magnification 4X 10X 40X 100X Eyepieces 10X 40X 100X 400X 1000X 16X 64X 160X 640X 1600X 4. Condenser numerical aperture: 1.25; 5. Stage cross travel range: longitudinal 35mm traverse 75mm; 6. Fine focusing knob: minimum division 0.002mm; 7. Interpupillary-distance adjustment range: from 53mm to 75mm; 8. Light sources: using a 6V 20W-halogen or LED lamp brightness adjustment; 9. Power supply: can be operated on AC 220V 50HZ or AC 110V 60HZ. 2

COMPONENTS 3

Fig.1 Fig.2 4

INSTALLATION Fig.3 MAKING OBSERVATIONS 1. Press the power switch on the side I. Place a specimen on the stage 2. Select the 10X objective into position by turning the nosepiece, then focus the specimen which is on the stage; 3. Adjust interpupillary distance and diopter whilst observing through the binocular eyepieces; 4. Adjust the up & down position of the condenser, light control and aperture diaphragm in order to obtain the optimal illumination effect. Select the 4X or 10X objective, bring down the condenser using the condenser s rack and pinion knob to obtain symmetrical light; 5. When selecting other objectives turn the nosepiece and refocus slightly with the fine focusing knob. When use the 100X objective, make be sure to put a drop of cedar wood oil between the objective and the specimen. 5

COMPONENT FUNCTIONS 1. Adjust of interpupillary distance Put the specimen on the stage and ring the specimen into exact focus. Adjust the interpupillary distance of binocular until the right-left field of view can be composed one. (Fig.4) Fig.4 2. Adjustment of diopter Fig.5 Put the specimen on the stage. Turn the 40X objective to working position. Firstly, observe at right column with right eye, adjust coarse-fine focusing knob to image clearly. Secondly, observe at left column with left eye, adjust the diopter control 1 to image clearly. ( Fig.5) 3. Coarse/Fine focusing Fig.6 The instrument used coaxial coarse/fine focusing mechanism. The adjustable tensional knob 4 used for adjusting the tension of the coarse focusing knob 3 to prevent the stage from naturally sliding down. The limit knob 1 prevents accidental specimen/objective contact. 2 is fine focusing knob.( Fig.6) 6

4. Stage The convenient specimen holder 1 on stage is used for holding slide glass 2, lengthwise knob3/cross knob 4 are coaxial, the stage move expediently.( Fig.7) Fig.7 5. Moving the condenser The condenser is moved up or down via turning up-down knob 1. The condenser can be taken down easily if unscrews the condenser holding screw2, filter plate places on the filter seat 4. (Fig.8) Fig.8 6. Power switch and adjustable brightness Turn on the power switch 6; adjust the light control 5 until image can be observed comfortably. (Fig.8) Note: Do not let the light control stay at the highest intensity position or it will reduce the life-span of the lamp. 7. Aperture diaphragm Switch on the power, put the specimen on the stage, then turn the 10X objective into the working position, observe with 10X eyepieces. Turning the up/sown condenser knob and reach the image of field diaphragm. Then Fig.9 concenter field diaphragm and optical axis with adjusting screw 2. Turn the ring 1 of field diaphragm when the field diaphragm more than the field of eyepiece. Using 4X objective, the adjust method as so. (Fig.9) 7

8. CHANGING THE LAMP (NOT NECESSARY FOR LED MODELS) AND FUSE(Fig.10) 1. Switch off the power supply and pull out the plug of electrical wire. 2. Incline the microscope, loose the screw 2 of fixing lamp base boards 3 on the middle part of bottom, and removes lamp baseboard from bottom. Fig.10 3. Pull out the old lamp from lamp base4. 4. Insert the new lamp into lamp base. Check it is properly connected. 5. Clean the new lamp with methanol. 6. Reinstall lamp base board on the bottom with the screw. 7. To check the positioning of the lamp, plug in the cable, turn on the power supply, select a low power objective, adjust condenser, and make the light enter the field of view. If the light is offset from the center of the field of view, loosen the screw and slightly and move the lamp base to make the lamp centered, then tighten the screw. 8. Unplug from the mains. Loosen the screw of fuse, remove the bad fuse, mount the new fuse, and tighten the screw. The specification of fuse:φ5,0.5a MAINTENANCE 1. Cleaning the optics Clean the optics using lens tissue or soft fabric immersed in methanol. Clean off excess immersion oil from the 100X objective after every use. 2.Cleaning the painted parts The dust on the painted parts can be removed by a lint free cloth or blower brush, for the grease spots, the gauze immersed slightly with methanol is recommended. 3. Avoid disassembling the microscope Being a precise instrument, do not disassemble the microscope casually that may cause serious damage to its performance. 4. Being not used Cover the microscope with a dust cover and store in dry place. We recommend that storage all objectives and eyepieces should be in closed container with drying agent. 8

SYMBIO MICROSCOPES SLIDER PHASE CONTRAST KITS USER MANUAL Example Phase Objectives Slider-Type Phase contrast condensers with inserts 9

Introduction The Symbio microscope is supplied with a flashboard phase contrast set containing x10 and x40 phase flashboards. When viewing with phase contrast, the flashboard corresponding to the lens magnification should be inserted into the slot in the condenser (see flashboard phase contrast set picture above). The microscope condenser has been set up and aligned at the factory and should not need any significant user adjustments. The Centering Telescope can be used to check the alignment of the flashboards in the condenser (see diag. 1.). If the flashboards are out of alignment, they can be centered using the condenser adjustment screws (see Fig. 1. In the Operating Manual) When you wish to make observations using phase contrast phase contrast you need to select a phase contrast objective and ensure that the phase contrast condenser is mounted with the corresponding phase contrast plate inserted which must have the same magnification indicated on it as the objective currently selected. See below example: Operating Procedure 1. Select a phase contrast objective, insert the corresponding phase contrast plate in position, adjust the condenser knob to move the condenser into the optimum position. 2. Place a specimen slide on the stage, and focus onto the specimen. 3. Remove one eyepiece and insert the centering telescope 2, as in diag 1-a 4. Look through the phase telescope and observe the dark ring 3 and bright ring 4, as in diag 1c 5. If the ring edges are not clear enough, adjust the phase telescope extension ring 1 to bring it into focus. 6. Phase contrast observation requires that the center of dark and bright rings are perfectly concentric. If they are not concentric (non-concentricity is shown in diag 1-c), adjust the centering screws of the phase plate 5 as shown in diag 1b, the correct observed setting should be as shown in diag 1-d 7. When you have completed the phase ring alignment remove the centering telescope and insert the eyepiece. Please Note: When you change to a different power objective, the phase system will require re-adjustment to ensure optimum phase contrast performance. 10

1 2 a c 3 4 b 5 Diag 1. d 11