Rack cooling solutions for high density racks management, from 10 to 75 kw

Similar documents
IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

IT COOLING DATA CENTER COOLING THE MILESTONE OF GREEN DATA CENTER COOLING TECHNOLOGY

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

IT Air Conditioning Units

Reliability and extended operation

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Efficiency of Data Center cooling

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Climaveneta for Data Center. The Milestone Of Green Data Center Cooling Technology

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Total Modular Data Centre Solutions

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Precision Cooling Mission Critical Air Handling Units

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

2018 Product overview

Liquid Cooling Package LCP Cooling Systems

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Close-coupled cooling

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

Rack & Enclosure Systems

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liquid Cooling Package LCP Cooling Systems

Communication Register Map - Uniflair Cooling

Ecoflair Air Economizers

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

MOLLIER DIAGRAM CAN BE IMPROVED!

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Data Center Optimized Controls

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Industry leading low energy evaporative fresh air cooling.

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Switch to Perfection

SmoothAir Modular Precision Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Ecotel Free Cool 5-15kW

Welcome Association of Energy Engineers to the Microsoft Technology Center

Rittal Cooling Solutions A. Tropp

Thermal management. Thermal management

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

Introducing the Heat Wheel to the Data Center

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

4-step Chiller and Heat Pump Controller

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert DCW CATALOGUE

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert PDX from 15 to 120 kw

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

LCP Hybrid Efficient performance with heat pipe technology

High Efficient Data Center Cooling

Liebert. DCL up to 35 kw. Modular Rack Cooling

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert HPM from 4 kw to 100 kw

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

New Design Strategies for Energy Saving. Intelligent free-cooling

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Scalable, Secure. Jason Rylands

Liebert PDX from 15 to 120 kw

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Next Generation Cooling

Overcoming the Challenges of Server Virtualisation

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

ecoenergy Innovation Initiative Research and Development Component Public Report

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

Virtualization and consolidation

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

How to Increase Data Center Efficiency

Perfect Cooling. A perfect climate for high performance servers

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

MEASURE MONITOR UNDERSTAND

Data Center Trends: How the Customer Drives Industry Advances and Design Development

84 kw, Tier 3, Direct Expansion, 937 ft 2

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Transcription:

Rack cooling solutions for high density racks management, from 10 to 75

Superior efficiency, high reliability, low energy consumption Modern data center are characterized by 24/7 operation all year long. Climaveneta has developed its own answer: efficient and reliable cooling units for the management of high density racks. 2 l 3 CRC

Hot Spot management Scalability and Modularity CRC unit stands for ideal integration to manage high density severs (blade servers), better known as hot-spots. The advantages are: < Extra cooling where it is needed < Direct Expansion systems with Inverter technology or chilled water version available < Modulating Air flow, thanks to EC high efficiency fans. The fans adapt to the thermal load detected by sensors positioned in the hot and cold aisles < Perfectly compatible with most of racks and ready for expansion of the cooling system The CRC units have been developed to be coupled with modern racks in data centers, allowing: < More versions available, suitable for 42U and 47U racks < GREAT SCALABILITY of the cooling system, as the units easily adapt to the real thermal load of the server < MODULARITY of the cooling system and rapid Upgrade of the Data Center capacity Active free cooling The CRC units combine the efficiency of a hydronic system for heat dissipation together with the use of new generation EC fans, allowing EER values over 100. High Density blade servers cooling systems with single or dual circuit allow the use of warm water with a temperature > 15 C. This contributes to improve all those free-cooling systems performances even in places which are normally considered too hot for such efficient systems. In the CRC Dual Circuit version, while the primary circuit (circuit 1) could be water cooled via an external dry cooler in order to maximize the free cooling benefits, the secondary backup circuit (circuit 2) can be easily combined with a Freecooling chiller to obtain best values in terms of REDUNDANCY & EFFICIENCY. Redundancy and Reliability Modern data centers have to guarantee an efficient 24/7 operation in order to eliminate the risks of malfunctioning and failure. The total redundancy of the system is therefore of utmost importance for the highest realiability of the data center. The new Dual Coil version has been developed to guarantee the 100% backup thanks to: double cooling coil and double regulation valve which are ccompletely independent. The reliability of the system is also increased by the use of automatic switch for dual power supply feed for a CONTINUOUS and REDUNDANT power supply.

Versions Four versions. Four specific technologies specially designed to ensure superior efficiency and reliability. CRCX Direct Expansion Version CONFIGURATIONS CRCX-I - Direct Expansion Rack Cooler IN-ROW CRCX-E - Direct Expansion Rack Cooler ENCLOSURE The CRCX unit joins the efficiency of a new Direct Expansion system with the use of the Inverter Technology and the latest brushless DC electric motor. Good performance and high efficiency are the result of the adoption of advanced technologies: Savings up to 30% compared to traditional systems < The Inverter DC technology on the Scroll compressor with the new generation brushless motor < The electronic thermostatic valve: it allows to improve the inverter compressor performance, and the frigorific cycle optimisation < New generation EC brushless fans ultralight < Completely sensible load (SHR=1) <'HOT SWAPPABLE' EC fans from the front < Easy handling due to integrated wheels CRCC Chilled water version CONFIGURATIONS CRCC-I - Chilled Water IN-ROW CRCC-E - Chilled Water ENCLOSURE In the hydronic version the cooling is provided by external chillers and dry coolers, to better use the freecooling system. Good performance and high efficiency are the result of the adoption of advanced technologies: bigger savings 25% thanks to the adaptive set point according to the real thermal load < New generation EC brushless fans ultralight < 3 way or 2 way (optional) modulating valves < Capacity from 16 to 74 < Optimal integration with Climaveneta Freecooling chillers < 'HOT SWAPPABLE' EC fans from the front < Easy handling due to integrated wheels 4 l 5 CRC

CRCD Dual Fluid Version CONFIGURATIONS CRCD-I - Direct Expansion Dual Fluid Rack IN-ROW CRCD-E - Direct Expansion Dual Fluid Rack ENCLOSURE The Dual Fluid Rack Cooler features two separate circuits for the highest redundancy in cooling capacity. Thanks to a system ensuring 100% back-up, the high reliability of the system is always guaranteed, also in emergency situations. 100% backup Reliability all year long < Inverter DC Scroll compressor featuring last-generation electronic-switching brushless motor < Electronic expansion valve to ensure superior performance of the inverter compressor and frigorific cycle optimisation < New generation ultralight fans, with EC brushless motor < Complete sensible load (SHR=1) < Easy handling due to integrated wheels < Hot swappable EC fans from the front CRCF Free Cooling Version CONFIGURATIONS CRCF-I - Direct Expansion Rack with indirect free cooling IN-ROW CRCF-E - Direct Expansion Rack with indirect free cooling ENCLOSURE The CRCF Rack Cooler ensures high levels of energy efficiency thanks to the combination of the direct expansion system with the indirect free cooling mode. The CRCF unit works in free cooling mode when the outside temperature allows to use the outdoor air as a source of indirect cooling. The simultaneous operation of the expansion system and the water system contributes to increase the overall efficiency. of the year in free 60% cooling mode < Inverter DC Scroll compressor featuring last-generation electronic-switching brushless motor < Electronic expansion valve to ensure superior performace of the inverter compressor and frigorific cycle optimisation < New generation ultralight fans, with EC brushless motor < Complete sensible load (SHR=1) < Easy handling due to integrated wheels < Hot swappable EC fans from the front

Configurations Modern data centers are characterised by specific requirements: specific room dimensions, redundancy, easy adaptation to preexisting structures. This is why Climaveneta has developed two CRC configurations: In-row and Enclosure. In-Row CRCC-I: Chilled Water CRCX-I: Direct Expansion CRCD-I: Dual Fluid CRCF-I: Free Cooling In the InRow configuration the treated air is sucted in the back of the unit from the hot aisle of the Data Center (35 C), with great advantages in terms of energy efficiency and increased cooling capacity. The air is then cooled and delivered to the cold aisle (18-20 C) - i.e. the front side of the rack. Features and Benefits Design < Back-Up system for power and cooling < Hot swappable EC fans from the front < Scalability and modularity < Data Center extension Energy Savings < Cooling only where it is needed < Optimised management of the system < Extreme flexibility (applicability to 42U & 47U racks) Highly efficient Operation < Reduced space occupancy (0,39 m 2 ) < Plug & Play connections for a quick and easy installation < User-friendly Cascade System for electrical panel maintenance < Humidification System (optional) Ideal for hot/cold aisles 6 l 7 CRC

Enclosure CRCC-E: Chilled Water CRCX-E: Direct Expansion CRCD-E: Dual Fluid CRCF-E: Free Cooling In the Enclosure configuration both the servers and the conditioners are coupled on the same structure, avoiding the mixing of indoor and outdoor air and the consequent efficiency reduction. The air is directly treated inside the rack; sucted at 46 C, cooled down to 25-30 C and then delivered back to the servers. This increases energy saving thanks to the low amount of treated air. Features and Benefits Design < Back-Up system for Power and Cooling < Hot swappable EC fans from the front < Scalability and modularity < Data Center extension Energy Savings < Increased energy savings thanks to the low amount of treated air < Optimised blade management < Extreme flexibility (applicability to 42U & 47U racks) Highly efficient Operation < Reduced space occupancy (1,8 m 2 ) < Plug & Play connections for a quick and easy installation < User-friendly Cascade System for electrical panel maintenance < Humidification System (optional) Ideal for removing hot spots in stand alone systems

Technological choices DC Inverter compressor for the CRCX, CRCF and CRCD versions The inverter driven compressor, through the variable frequency, modulates the power capacity provided, hence enabling to optimize the performances at part load and increasing the overall efficiency of the system in any condition. Compared to the traditional On/Off compressors the Inverter compressor ensures: < Quick achievement of the desired temperature thanks to the BOOSTER function < Starting current & pick removal due to compressor speed and air flow modulation < Reduced vibrations and low noise levels < Efficient working performance at partial loads EC-PUL fans for all indoor units POLYMERIC ULTRALIGHT FAN The high efficiency EC brushless fan reduces both noise levels as well as energy consumption, and assures a variable air flow at part loads, optimizing the operating costs of the unit. Main features: < Further noise level reduction 4-5 db < Further absorbed power reduction by 15% EC-PUL FANS also for outdoor units -10% -15% -45% The use of EC brushless technology even on the remote motocondenser (optional) fan assures a further average reduction of noise levels by 10%, together with a strong reduction of energy consumption by 45% compared to traditional condensers with AC technology. Plug-in (AC) EC (DC) EC PUL generation (DC) 8 l 9 CRC

Electronic Thermostatic Valve The Direct Expansion CRC units with DC Inverter compressor make use of electronic expansion valve as standard. These valves have a much wider modulation capacity. It stands out for its quality of control and its capacity to quickly reach and maintain the operating stability of the unit. Joined with the INVERTER compressor technology, the valve ensures a quick fluctuation-free regulation, and therefore a highly accurate adjustment to the swings of load and ambient conditions. Ecologic Refrigerant The R-410A represents the most modern and look-ahead choice in refrigerant technology: it clearly contributes to make the ICT GREEN since it complies with environmental friendly policies and provide enhanced cooling efficiency. The R-410A represents the most efficient long-term solution; it contributes to increase the energy efficiency up to 5-6% compared to the R-407c refrigerant, avoiding air pollution. Evolution Control TEGRATED DYNAMIC MANAGEMENT OF THE TEMPERATURE The units are provided with a new algorithm called IDM-INTEGRAL DYNAMIC MANAGEMENT, which allows to avoid the stratification of the air temperature inside the rack through the use of 4 integrated and independent sensors (2 for aspiring and 2 for leaving). On the basis of the real load in each single blade, the sensors contribute to improve the ventilation efficiency, working where it is requested. This helps to maximize the energy efficiency. L IDM guarantees the optimal air temperature and humidity management via a dynamic system able to avoid local condensation thus maintaining SHR = 1-

Technical data CRCX Direct Expansion Version Model Power Supply Power abs compressor Power abs condensation fan Power abs evaporator fan Air flow m 3 /h EER No. circuits Dimensions Indoor unit HxPxL mm Outdoor unit HxPxL mm CRCX-I + i-hcat 0051 0071 0121 0151 0251 230V/1N/50Hz* 400V/3N/50Hz* 400V/3N/50Hz* 400V/3N/50Hz* 400V/3N/50Hz* max min. max min. max min. max min. max min. 10,63 4,72 16,59 6,78 28,62 11,76 37,20 21,88 57,47 27,29 9,61 4,72 15,67 6,78 27,37 11,76 37,20 21,16 57,47 27,29 2,63 0,77 4,56 1,17 7,19 1,81 9,5 4,37 14,4 4,05 0,31 0,31 0,6 0,6 1,2 1,2 1,12 1,12 1,68 1,68 0,16 0,04 0,304 0,064 0,860 0,090 0,98 0,28 2,6 0,51 1500 900 2700 1200 4200 1800 7000 3500 12000 6000 3,43 4,21 3,03 3,7 3,1 3,8 3,21 3,79 3,07 4,37 1 1 1 1 1 2100x1000x300 2100x1000x300 2100x1000x300 2100x1000x600 2100x1000x600 1240x420x900 1200x550x1450 1700x550x1450 1865x1195x1825 1865x1195x2395 Performances at the following conditions: 35 /27% U.R. and 35 C outdoor temperature CRCX Direct Expansion Version Model Power Supply Power abs compressor Power abs condensation fan Power abs evaporator fan Air flow m 3 /h EER No. circuits Dimensions Indoor unit HxPxL mm Outdoor unit HxPxL mm CRCX-E + i-hcat Performances at the following conditions: 46 /16% U.R. and 35 C outdoor air temperature CRCC Chilled Water Version CRCC-I Model 0020 0025 0035 0036 Power Supply 230V/1N/50Hz* 16,14 20,52 24,60 20,95 16,14 20,52 24,60 20,95 Water pressure drops kpa 30,00 35,00 40,00 70,00 Water flow m 3 /h 2,77 3,53 4,23 3,60 Power abs evaporator fan 0,516 0,688 0,860 0,860 Air flow m 3 /h 2520 3360 4200 4200 No. circuits Dimensions 1 1 1 2 Indoor unit HxPxL mm 2100x1000x300 Performances at the following conditions: 35 /27% U.R. and 10 /15 C water temperature * 60Hz versions available The data in the table refer to the above power supply 0051 0071 0121 0151 0251 230V/1N/50Hz* 400V/3N/50Hz* 400V/3N/50Hz* 400V/3N/50Hz* 400V/3N/50Hz* max min. max min. max min. max min. max min. 11,84 5,64 18,71 8,19 33,02 14,09 44,11 25,83 68,38 33,12 11,84 5,64 18,71 8,19 33,02 14,09 44,11 25,83 68,38 33,12 2,68 0,73 4,65 1,15 7,4 1,81 9,81 4,4 14,95 3,99 0,31 0,31 0,6 0,6 1,2 1,2 1,12 1,12 1,68 1,68 0,16 0,04 0,3 0,06 0,86 0,09 0,98 0,28 2,6 0,51 1500 900 2700 1200 4200 1800 7000 3500 12000 6000 3,8 5,2 3,37 4,52 3,5 4,54 3,70 4,45 3,56 5,36 1 1 1 1 1 2100x1200x300 2100x1200x300 2100x1200x300 2100x1200x600 2100x1200x600 1240x420x900 1200x550x1450 1700x550x1450 1865x1195x1825 1865x1195x2395 * 60Hz versions available The data in the table refer to the above power supply 0040 0050 0060 0055 400V/3N/50Hz* 38,45 46,9 58,2 47,12 38,45 46,9 58,2 47,12 68 38 56 62 6,61 8,06 10 8,1 1,73 2,12 2,6 2,64 8000 8800 12000 10500 1 1 1 2 2100x1000x600 * 60Hz versions available The data in the table refer to the above power supply CRCC Chilled Water Version CRCC-E Model 0020 0025 0035 0036 Power Supply 230V/1N/50Hz* 20,44 26,06 31,25 26,79 20,44 26,06 31,25 26,79 Water pressure drops kpa 30,00 40,00 45,00 80,00 Water flow m 3 /h 2,93 3,74 4,49 3,85 Power abs evaporator fan 0,52 0,69 0,86 0,86 Air flow m 3 /h 2520 3360 4200 4200 No. circuits Dimensions 1 1 1 2 Indoor unit HxPxL mm 2100x1200x300 Performances at the following conditions: 46 /16% U.R. and 14 /20 C water temperature 0040 0050 0060 0055 400V/3N/50Hz* 49,27 60 74,71 60,69 49,27 60 74,71 60,69 75 42 63 69 7,07 8,62 10,73 8,71 1,73 2,12 2,6 2,64 8000 8800 12000 10500 1 1 1 2 2100x1200x600 * 60Hz versions available The data in the table refer to the above power supply 10 l 11 CRC

CRCD Dual Fluid Version Model Power supply Performance (DX) Compressor power abs Condensing unit s fan power abs EER Performance (CW) Water flow l/h CRCD pressure drop kpa Fans Air flow m 3 /h Indoor unit s fan power abs Dimensions Indoor unit HxPxL mm Outdoor unit HxPxL mm CRCD-I + i-hcat air cooled (1) Performances at the following conditions: 35 C/27% U.R., 35 C outdoor air temperature (2) Performances at the following conditions: 46 C/16% U.R., 35 C outdoor air temperature (3) Performances at the following conditions: 35 C/27% U.R., 10 /15 C water temperature CRCD-E + i-hcat air cooled (4) Performances at the following conditions: 46 C/16% U.R., 14 /20 C water temperature * 60Hz versions available The data in the table refer to the above power supply CRCF Free Cooling Version CRCF-I + i-hcft water cooled CRCF-E + i-hcft water cooled Model Power supply Performance (DX) Compressor power abs compressor Condensing unit s fan power abs EER Performance (FC) Water flow l/h CRCF pressure drop kpa Pump power abs i-hcft available pressure kpa Fans Air flow m 3 /h Indoor unit s fan power abs Dimensions Indoor unit HxPxL mm Outdoor unit HxPxL mm 0051 0071 230V/1N/50Hz* 400V/3N/50Hz* max (1) min (1) max (1) min (1) 10,95 4,55 13,99 6,93 10,24 4,55 13,99 6,93 2,64 0,77 3,58 1,17 0,31 0,31 0,6 0,6 3,35 4,06 2,87 3,76 Performance (3) Performance (3) 9,53 17,7 9,53 17,7 1640 3040 14,9 45,7 max min max min 1500 700 3360 1500 0,32 0,04 0,69 0,072 2100x1000x300 1240x420x900 2100x1000x300 1200x550x1450 0051 0071 230V/1N/50Hz* 400V/3N/50Hz* max (1) min (1) max (1) min (1) 11,29 4,66 14,67 7,16 10,38 4,66 14,67 7,16 2,41 0,69 3,08 1,06 0,6 0,6 1,2 1,2 3,02 2,68 2,73 2,61 Performance (3) Performance (3) 9,89 17,7 9,89 17,7 2370 3070 28,7 46,6 0,41 0,41 86 92 max min max min 1500 700 3360 1500 0,32 0,04 0,69 0,072 2100x1000x300 1200x550x1450 2100x1000x300 1700x550x1450 0051 0071 230V/1N/50Hz * 400V/3N/50Hz* max (2) min (2) max (2) min (2) 12,7 5,4 16,71 8,41 12,7 5,4 16,71 8,41 2,71 0,74 3,65 1,15 0,31 0,31 0,6 0,6 3,80 4,95 3,38 4,62 Performance (4) Performance (4) 12,10 22,6 12,10 22,6 1740 3240 16,3 50,1 max min max min 1500 700 3360 1500 0,32 0,04 0,69 0,072 2100x1200x300 1240x420x900 2100x1200x300 1200x550x1450 0051 0071 230V/1N/50Hz * 400V/3N/50Hz* max (2) min (2) max (2) min (2) 12,93 5,51 17,52 8,7 12,93 5,51 17,52 8,7 2,5 0,64 3,11 1,03 0,6 0,6 1,2 1,2 3,38 3,26 3,24 3,21 Performance (4) Performance (4) 12,48 22,8 12,48 22,8 2670 3570 35,9 59,6 0,41 0,41 77 81 max min max min 1500 700 3360 1500 0,32 0,04 0,69 0,072 2100x1200x300 1200x550x1450 2100x1200x300 1700x550x1450 (1) Performances at the following conditions: 35 C/27% U.R., 30/35 C condensing water temperature (2) Performances at the following conditions: 46 C/16% U.R., 30/35 C condensing water temperature (3) Performances at the following conditions: 35 C/27% U.R., input water FC 10 C (4) Performances at the following conditions :46 C/16% U.R., input water FC 14 C * 60Hz versions available The data in the table refer to the above power supply

CRC_09-2014_ENG