SWITCHGEAR MODELS CEP 14 / 15

Similar documents
Air-insulated medium-voltage secondary distribution switchgear

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

PDI Modular Compact Remote Power Panel

MCR 3. POWER EQUIPMENT MCR 3 I Constant Current Regulator. Microprocessor Controlled Constant Current Regulator. Compliance with Standards.

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Safe monitoring relays

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

Earth-fault Relay SPAJ 110 C. Product Guide

3RV1 Circuit-Breakers

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Switch Disconnectors, Main and EMERGENCY-STOP Switches

The right solution for every home

SIRCO Load break switches for power distribution from 125 to 5000 A

Package Substation. The efficient solution for your electrical distribution network

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

Microprocessor protection and automation devices

Section 4 Ground-Fault Protection Devices

Innovation on Medium Voltage Switchgear

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Circuit Breakers Type CTI 25M, CTI 45MB

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

UEMC 41 Motor Operating Device

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Adaptors Busplug Low Voltage Switchboard Equipment

Synchro-check relay. Application

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Specification Sheet: HT SERIES

Innovation for MV distribution

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

IDIS. Medium-Voltage Components. Intelligent Density Information System. Operation - Replacement Technical Instruction

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Uninterruptible Power Supplies

MIC-2 MKII, Multi-instrument DATA SHEET

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

Extension module for lighting control

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

Residual overvoltage relay

MOTOR PROTECTION CIRCUIT BREAKERS

TECHNICAL DESCRIPTION

Safe timer relay/contact expansion modules

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Refurbished 1U 19in Rackmount LCD Console with Integrated 8 Port KVM Switch

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Residual Current Devices drcm Digital

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Feeder protection relay SPAA 121 C. Product Guide

SLI 15 INVERTER SERIES, 1500 W

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ABB AG - EPDS. Gas-insulated switchgear Type ZX2

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

QUINT-PS/ 1AC/24DC/20/CO

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

60103 Circuit Breaker

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Electrical Actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

TP&N DISTRIBUTION BOARD TYPE B RANGE

Specification Voltage Limiting Device

Power Control Systems

1510 MOTOR CONTROLLERS

Electrical Actuators

DIRIS N300/N600 Network analysers Network quality control and analysis system

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

SPM Series Plug-in Surge Protection

High Safety low voltage switchgears For maximum requirements far beyond all standards.

Prisma Plus System P Cubicles up to 4000 A

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Blue e+ chillers with the principle

SECTION SWITCHBOARDS

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Safety Systems Safety Integrated

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Transcription:

PRODUCT LEAFLET SWITCHGEAR MODELS CEP 14 / 15 For network 950 V - 3,200 V - 5,500 V - 6,600 V Switchgear with three compartments Outgoing feeder contactor Switchgear with two compartments Outgoing feeder contactor 1 60 11952-04/08/2014

2

SWITCHGEAR MODELS CEP 14 / 15 SUMMARY GENERAL INTRODUCTION... 4-5 FIELD OF APPLICATION, STANDARDS... 5 RANGE OF SWITCHGEARS... 6 EXAMPLE OF CONFIGURATION... 7 SWITCHGEAR CHARACTERISTICS... 8-14 ELECTRICAL CHARACTERISTICS... 16 ELECTRICAL CIRCUIT DIAGRAM... 17 DIMENSIONS and WEIGHTS... 18 CABLE ROUTING... 19 LOCKING and SAFETY... 20-21 LOW-VOLTAGE CABINET... 22 SERVICE and TRAINING... 23 3

Introduction Work with a French manufacturer Since 1973, AUGIER has been designing and manufacturing a range of CEP switchgears at its production facility in Carros, France. Global references CEP switchgears are installed worldwide on lighting applications and other load demands. A detailed list of references is available on request. Quality Assurance AUGIER is ISO 9001 certified since 1995. The implementation of quality checks with these switchgears calls for: Stringent checks at every stage of the manufacturing process Tests to assure compliance with applicable technical standards Technical Support AUGIER service team is available to provide technical assistance for: Switchgears commissioning Operational training Equipment maintenance A range of compatible switchgears As part of the Augier management process, you will be kept informed of the status of every component of the switchgear. The measuring function lets you track the consumption of every outgoing feeder on the network. Safe and secure to use Your safety is our priority. The concept of a pluggable carriage linked to a padlocking system ensures that access is very simple and entirely safe. Compatible with existing switchgear Compact The footprints of CEP 14/15 switchgears are identical to those of previous generations. Existing switchgears can be easily upgraded to benefit from the latest CEP 14/15 switchgear technology. Switchgears with a footprint of 750x950 mm give 4

CEP 14 / 15 SWITCHGEARS CEP 14: single-phase network - CEP 15: 3-phase network FIELD OF APPLICATION: AUGIER switchgears are specifically designed to power extensive 950V, 3200V, 5500V, 6600V networks. The switchgear compartments can be equipped with a cut out switch or appropriate contactor depending on the operating voltage. The control and protection devices used may be required to operate 2,000 times a year or more. The equipment offered by AUGIER delivers many functions, including the following: Protection at maximum intensity, even when faults occur far away from the transformer substation Selection of sophisticated triggers between the network s protection elements Heavy duty o p e r a t i o n capability. P r o t e c t i o n against earth faults AUGIER s solution to increase the reliability of your installed equipment was to create a switchgear that uses: A 1kV or 7.2kV contactor with high isolating capability. The simplicity of the electrical control unit and the robust mechanical and electrical structure of its contactors give these devices, designed for intensive operation, long-term reliability under normal operating conditions. The isolation device can be in sulphur hexafluoride (SF 6), or in vacuum or in the air Indirect TI protection (overload fault) and earth fault are controlled by microprocessor Direct protection is provided by fuses with high rupturing capacity. INTRODUCTION: A switchgear can include two or three stacked compartments. You choose the function of a compartment to suit requirements. The full cabinet is in the protected category, IP 3XC, grey-coloured, RAL 7035 and 7016, and is for indoor use. The frames are made of folded and welded steel sheets and the separations are made of welded or screwed steel sheets. The switchgears have a compact design. Example of a switchgear including 3 compartments (three distinct functions): Width 750 x Depth 950 x Height 2060 mm. The compartments with pluggable carriage perform the visible cut-out essential for safety. Due to their design, the switchgears do not require rear access. To open the doors and to remove the mobile carriages completely, a gap at the front measuring roughly 1200 mm is sufficient (minimum: 1000 mm). The complete isolation of an outgoing feeder is achieved by unplugging the contactor carriage and by closing the earthing switch and the cut out circuit switch on the outgoing feeder cable. A switchboard panel is made up of several switchgears placed side by side, joined together electrically by a busbar located in the busbar compartment. STANDARDS: CEP 14/15 AUGIER switchgears comply with the recommendations contained in technical standards: CEI - NF EN 62271-1: High-voltage equipment - Section 1: shared specifications. CEI - NF EN 62271-200: Equipment in a metal enclosure for AC voltages greater than 1kV and less than 52 5

THE RANGE OF CEP 14 / 15 SWITCHGEARS Isolating switches SA SATA STA SC SD Incoming isolating switch Incoming isolating switch and Auxiliary transformer Auxiliary transformer Isolating switch Coupling isolating switch Outgoing feeder isolating switch The contactors CA CC D N S Incoming contactor Coupling contactor Outgoing feeder contactor Normal/emergency contactor FUNCTION NAME USE Page Incoming isolating switch SA Connection to power transformer, no voltage cut-out. 8 Incoming isolating switch and Auxiliary transformer SATA Function of incoming isolating switch plus power supply to auxiliaries on the substation. 5 kva power, single-phase 230 V. 8 Coupling isolating switch SC In combination with the incoming isolating switch, the coupling isolating switch makes it possible to install two transformers to secure the substation. 9 Outgoing feeder isolating switch SD Power supply to the network. no-voltage cut-out. Network protection exclusively fuse-based. 9 Auxiliary transformer Isolating switch STA Power supply to auxiliaries at the substation. 5 kva power, single-phase 230 V. 10 Spare outgoing feeder RD Pre-equippd to install an outgoing feeder contactor in future. 10 Incoming contactor CA Connects to power transformer, load cut-out, remote control possible. 11 Coupling contactor CC In combination with the incoming contactors, the coupling contactor makes it possible to install two transformers to protect the substation. 11 Outgoing feeder contactor D Power supply to a network. Load cut-out, fuse protection associated with maximum current protection and protection against earth faults. 12-13 Normal / emergency contactor NS Automatic switching to emergency power supply if there is no power from the normal source. 14 Empty V Empty compartment, cannot be retrofitted. 15 6

CEP 14 / 15 SWITCHGEARS - Example of configuration Power supply to network outgoing feeders from a single transformer Transformer substation SA D D Transformer 400 V / MV step-up HV/MV step-down MV network MV/LV transformer Power supply to network outgoing feeders from two transformers Transformer substation SATA D D SC D SATA Transformer 400 V / MV step-up HV/MV step-down MV network MV/LV transformer 7

Characteristics of the switchgears: INCOMING ISOLATING SWITCH: SA SA Used to achieve general isolation downstream the main transformer. Basic equipment: Fixed part comprising: The set of vertical busbars, 300 A- calibre, twin-phase or 3-phase. The earthing switch. The lateral bush routing the incoming cable. The connection panels for the incoming cable, attached by sleeves. The 300 A-calibre connection points. The manually controlled metal shutter preventing access to the busbar connection points when the door is open. Movable part: Comprising an isolating switch carriage switch carriage and moving of door until downstream device is not earthed. Optional accessories: Striker fuses of an appropriate calibre for the power of the transformer. Fuses installed on the isolating switch carriage. With signalling device on melting fuse on terminal output. Size of fuse available from 2 to 160 A. Monitoring pack (CTM: Centralised Technical Management) comprising: Output voltage MV on the terminal. LED voltage indicators Compartment for low incoming isolating switch Additional equipment: LED voltage indicators. Locking: Locks by padlock on the downstream device to prevent the operation of isolating Characteristics of the switchgears: INCOMING ISOLATING SWITCH AND AUXILIARY TRANSFORMER: SATA SATA The SATA performs all the functions of the incoming isolating switch as well as delivering power to the auxiliary transformer substations. Basic equipment: Identical to the incoming isolating switch Additional equipment: A single-phase transformer, dry isolation, power 5kVA, ratio 3200 V, 5500 V or 6600 V / 230 V. One or two HRC fuses to protect the primary fuse on the auxiliary transformer from short circuits. LV equipment: a 25A - 300 ma differential circuit breaker installed on the door. Incoming isolating switch equipped with HRC Optional accessories: Identical to the incoming isolating switch. 8

Characteristics of the switchgears: COUPLING ISOLATING SWITCH: SC SC This compartment is used to connect two powered semi-busbars, each one via an incoming Basic equipment: Fixed part comprising: The vertical busbars, 300 A-calibre, twinphase or 3-phase. The right-hand lateral bush routing the incoming cable. The 300 A-calibre connection points. The two manually controlled upstream/ downstream metal shutters that prevent access to the busbar connection points when the door is open. moving, the transformers from becoming parallel-aligned and the door from opening. Optional accessories: Carriage plugged in position with return of information to the terminal. Movable part: Comprising a isolating switch carriage Top compartment Coupling isolating switch Locking: Padlock on the incoming isolating switches prevents the carriage from Characteristics of the switchgears: OUTGOING FEEDER ISOLATING SWITCH: SD SD Connected upstream of the outgoing feeder, this isolating switch permits various functions, including: Network cut-out, powering down of the network Fuse protection of outgoing feeder Basic equipment: Fixed part comprising: The vertical busbars, 300 A-calibre, twinphase or 3-phase. The earthing switch. The right-hand lateral bush routing the outgoing cable. The connection panels for the outgoing cable, attached by sleeves. The 300 A-calibre connection points. The manually controlled metal shutter preventing access to the busbar connection points when the door is open. Movable part: comprising a isolating switch carriage Locking: Padlock on the upstream device, preventing the live isolating switch carriage from moving. Additional equipment: LED voltage indicators. Striker fuses of an appropriate calibre for the power of the outgoing feeder being supplied. Fuses installed on the isolating switch carriage. With signalling device on melting fuse on terminal output. Size of fuse available from 2 to 160 A. Optional accessories: Unipolar protection relay mounted on the compartment door. CTM Monitoring pack: Output voltage MV on terminal Carriage plugged in position and position 9

Characteristics of the switchgears: ISOLATING SWITCH and AUXILLARY TRANSFORMER: STA STA Used to deliver power to auxiliaries on the substation. The transformer is mounted on a Basic equipment: Fixed part comprising: The vertical busbars, 300 A-calibre, twin-phase or 3-phase. The right-hand lateral bush routing the incoming cable. The 300 A-calibre connection points. The manually controlled metal shutter preventing access to the busbar connection points when the door is open. Locking: Padlock on the downstream device prevents the carriage from moving and the door being opened until the downstream device is not earthed. Movable part: A single-phase transformer, dry isolation, power 5kVA, ratio 3200 V, 5500 V or 6600 V / 230 V. One or two HRC fuses to protect the primary fuse on the auxiliary transformer from short circuits. Low-voltage equipment with a differential circuit breaker, 25A - 300, installed on the door. Lower compartment equipped with an isolating switch for the auxiliary transformer. Characteristics of the switchgears: SPARE OUTGOING FEEDER : RD Compartment pre-equipped to install an outgoing feeder contactor in future. Basic equipment: This compartment comprises the framework of an outgoing compartment, without either a carriage or low-voltage equipment, and without current transformers. When required, it can be equipped with a carriage, the current transformers and the compartment door can be replaced by a complete door comprising LV devices. Fixed part comprising: The vertical busbars, 300 A-calibre, twinphase or 3-phase. The right-hand lateral bush routing the incoming cable. The 300 A-calibre connection points. The manually controlled metal shutter preventing access to the busbar connection points when the door is open. 10

Characteristics of the switchgears: INCOMING CONTACTOR: CA CA Connected downstream of the main transformer, the incoming contactor allows various options, including: The load cut-out from all the network s outgoing feeders Fuse protection of the transformer Remote control of engagement of the contactor Lower compartments: Incoming contactor Basic equipment: A fixed part comprising: The vertical busbars, 300 A-calibre, twin -phase or 3-phase, interlinking the compartments. The connection panels for the incoming cables, attached by sleeves. An earthing switch. The connection points and the metal shutter prevent access to the live busbars when the door is open. A movable part: Comprising a pluggable carriage with an SF6, 400A-calibre, 230 V or 48 V- power supply contactor, as well as high rupturing capacity striker fuses, sizes available range from 2 to 160A. Locking: Mechanical: preventing access to interior of compartment while the contactor is not open, and with the earthing switch closed. With padlock on the upstream feeder device, preventing the earthing switch from closing. Inspection control part: Using PCBs and microprocessor, allowing: Control of the contactor Management of the melting fuse for leakage of gas to SF6 Visualisation and configuration by screen Additional equipment: LED voltage indicators. Signalling and triggering device on melting fuse. RS 485/RS 232 serial connection. Information on management of incoming contactor, outputs on terminals and other need-based configurable information. Optional accessories: Position carriage plugged in and position of the earthing switch on the terminals. Characteristics of the switchgears: COUPLING CONTACTOR: CC CC This compartment is used to connect two semi-busbars, each powered by a main transform- Basic equipment: A fixed part comprising: The vertical busbars, 300 A-calibre, twinphase or 3-phase, interlinking the compartments. The connection points and the metal shutter prevent access to the live busbars when the door is open. A movable part: Comprising a pluggable carriage containing an SF6, 400A-calibre, 230 V or 48 V-power supply contactor. Locking: Mechanical: preventing access to the interior of compartment while the contactor is not open Electrical with the incoming contactors. Inspection control part: Using PCBs and microprocessor, allowing: Control of the contactor Management of the leakage of SF6 gas. Visualisation and configuration by touch screen Additional equipment: RS 485/RS 232 serial connection. Information on management of coupling contactor, outputs on terminals and other need-based configurable information. Optional accessories: 11 Carriage plugged in position on the

Characteristics of the switchgears: OUTGOING FEEDER CONTACTOR: D D Connected downstream of the network s outgoing feeder, the outgoing feeder contactor allows various functions, these include: The powering up of the outgoing feeder thanks to its electrical durability, capable of 100,000 movement cycles. Fuse protection of the outgoing feeder associated with a unipolar protection device and maximum intensity. Switchgear with two compartments Outgoing feeder contactor Basic equipment: A fixed part comprising: A busbar compartment, size 300A, interlinking the compartments. The connection panels for the outgoing cables, attached by sleeves. An earthing switch. The connection points and the metal shutter prevent access to the live busbars when the door is opened. A phase-based current transformer and a unipolar earth fault. A movable part: Comprising a pluggable carriage with an SF6, 400A-calibre, 230 V or 48 V-power supply contactor, as well as high rupturing capacity striker fuses, sizes to fit the network outgoing feeder power. Locking: Optional accessories: Mechanical: prevents access to the interior of compartment while the contactor is not opened and with the earthing switch closed. Protection and inspection control: Using PCBs and microprocessor, allowing: Control of the contactor Excess intensity protection of phases and unipolarity, of extensive networks. Measure of active power and reactive power by phase of voltage, total and partial power consumed, the power factor, the time in operation, the number of cycles and information about the presence of MV voltage. Measure with a precision of class 1 (+- 1%). Visualisation and configuration by touch screen DFTEP: Diurnal network monitoring. The DFTEP option enables the insulation of network cables to be monitored when they are not in use. It prevents the outgoing feeder contactor from closing whenever there is an insulation fault on the network. The DFTEP requires a TNRS type neutral regime. Additional locking action, releases a special key that can be used to unlock the viewing grid, or the locking device on the network transformer terminals. Astronomical clock to control lighting. Position carriage plugged in and position of the earthing switch on the terminals. Related information 4-2 0 m A ( i nt e ns it y, u ni pol a r c u r r e n t, The protection programme was specifically devised for networks that provide external power to lighting systems. Additional equipment: LED voltage indicators Signalling and triggering device on melting 12

Characteristics of the switchgears: Operating principle of the protection and inspection control of the outgoing feeder contactor: Every outgoing feeder contactor is factory preconfigured according to the network data provided. All the data and settings are displayed on a 7-inch TFT screen with a touch panel enabling all parameters to be read in clear format. Refer to the installation and maintenance documentation N 60 11901 which details the Set engagement timing from 0 to 20 minutes in increments of 1 second. Set engagement prevention timing from 0 to 1 second in increments of 0.1 second. Back up and update outgoing feeder setting parameters, straight onto a memory stick. functions indicated below. Operating mode: Access to the setting menus: The intuitive touchscreen interface allows quick setup of all parameters. Common actions performed by the operator: Set the protection threshold for line current from 0 to 200A in increments of 1 A, for each phase. Set the protection threshold for unipolar current from 0 to 20 A. Adjusted in increments of: 10 ma from 0 to 1A, 100 ma from 1 to 1A, 1 A from 10 to 20 A, After a fault that caused disengagement, move to Stop position, eliminate the fault and press the button to reset the protection devices. Then power up the system in manual mode before switching to automatic mode. If the automatic engagement c o n t r o l i s i n p l a c e, t h e c o n t a c t o r will remain engaged. The advantages of the management system for an outgoing feeder contactor: The management programme included as standard, the operation with STEP II carrier power remote control system. Online display of current levels. If the zero sequence current or the line current is greater than the controlled protection threshold, the contactor opens, an error message is displayed and LED indication for presence of voltage USB port connector Viewing port for position of earthing switch 7-inch TFT screen with touchpanel Contactor carriage handle. Viewing port for unplugging contactor carriage. Earthing switch handle. Measuring function: Measurement of the three phase Display active power Display reactive power Display power factor (cos phi) 13

Characteristics of the switchgears: NORMAL / EMERGENCY CONTACTORS: NS N S Connected downstream of two electrical power sources, the normal/ emergency contactor permits various options, including: Automatic switching to emergency power supply if there is no power from the normal source. The load cut-out from all the network s outgoing feeders Fuse protection of the source Short-circuiting and earthing of cables and connection to electrical power Automatismes Design: Switchgear with three compartments comprising two incoming contactors and one compartment receiving operational automation. Basic equipment for each incoming contactor: of compartment while the contactor is not opened, and with the earthing switch closed. Padlock on the upstream feeder device, prevents the earthing switch from closing. Electrical, prevents the two contactors from closing simultaneously. Emergengy Normal Normal/emergency A fixed part comprising: A busbar compartment, 300 A-calibre The connection panels for the incoming cables, attached by sleeves. An earthing switch. The connection points and the metal shutter prevent access to the live busbars when the door is open. A movable part: Comprising a pluggable drawer with an SF6, 400A-calibre, 230 V or 48 V-power supply contactor, as well as high rupturing capacity striker fuses, sizes to fit the source power, maximum 160A. Locking: Mechanical: prevents access to interior Inspection control part: Using PCBs and microprocessor, allowing: Control of the contactor Management of the melting fuse or leakage of SF6 gas Measurement of voltage. Visualisation and configuration by touchscreen. Additional equipment: LED voltage indicators. Signalling and disengagement on melting fuse. RS 485/RS 232 serial connection. Information on management of incoming Automation function: Installed in a dedicated compartment, the automation function allows the system to switch into emergency mode if there is a lack of voltage on one of the three phases, or a leakage of SF6 on the normal contactor. Whenever an absence of voltage is detected on the normal circuit, the automation function allows the system to switch to the emergency circuit. If voltage is restored to the normal circuit, the normal/emergency switchgear returns to its initial position, with priority given to the normal contactor. On a melting fuse, the automation function will inhibit the change from normal to emergency. 14

Characteristics of the switchgears: STEPII compartment: MCEP Compartment equipped with a coupling module permitting the information to be transmitted by the powerline communication in the event of the STEP II remote control system being used. Characteristics of the switchgears: RELIFT compartment: RH Installed below a switchgear with three compartments, the relift compartment enables the height of a CEP14-15 switchgear to be restored with an existing old generation of switchgear (model CEP 7 to 9) with a height of 2250 mm. Characteristics of the switchgears: EMPTY compartment: V Compartment not used, without equipment, closed by a door. This compartment is intended to CEP15 switchgears comprising Two incoming isolating switches with auxiliary transformer One coupling isolating switches Five outgoing feeder contactors One spare outgoing feeder Control cabinet for lighting and monitoring 15

CEP 14 / 15 SWITCHGEARS - electrical characteristics Electrical characteristics: These characteristics apply in operating temperatures of between 0 C and +55 C and at altitudes of less than 1000 metres. Operating voltage : Class 7.2 kv Nominal frequency : 50 Hz Dielectric behaviour : 20 kv - 50 Hz - 1 minute Nominal intensity : 300 A Current transformer: Transformer with dry insulation. Ratio : 100/0.1 Power : 0.05 VA Class : 10P10 7.2-kV contactor: Cut-out device for SF6 based on rotating arc design. Calibre : 400 A Cut-out capacity : 10 ka eff Electrical control : Electro-magnet 230 V-50 Hz On-call consumption : 900 VA Holding consumption : 40 VA Mechanical endurance : 300 000 movements Earth fault detection device: Ratio : 20/0.2 Power : 0.1 VA Class : 10P10 AUGIER 7.2 kv FUSES HRC fuses: High rupturing capacity fuses of an appropriate calibre for the outgoing Compliant with standards: IEC 60282-1 DIN 43625 power level. Calibre Size Reference 2 Contact us 4 Contact us 6 10 23516 10 10 23517 16 53 x 258 10 22975 20 10 23518 25 10 23519 32 10 23520 40 10 23521 50 10 23522 63 68 x 258 10 23523 80 10 23524 100 10 23525 125 85 x 258 10 23526 160 10 23527 16

Electrical circuit diagram for CEP 15 outgoing feeder contactor Refer to the drawings supplied with your equipment to see the specific characteristics of the 17

CEP 14 / 15 SWITCHGEARS - dimensions Switchgear with two compartments 2 compartments switchgear Switchgear with three compartments 3 compartments switchgear Dimensions and weight Width (mm) Depth (mm) Height (mm) Weight (kg) Switchgear with 2 750 950 1420 350 Switchgear with 3 750 950 2060 520 18

CEP 14 / 15 SWITCHGEAR - cable routing Switchgear with two or three compartments - cable routing to ground, mounting cable routing and mounting Example Civil engineering installation - cable routing to ground 19

CEP 14 / 15 SWITCHGEARS - locking devices The locking devices are mechanical, operational and appropriate to the configuration of the panel. These prevent, most importantly: The carriage being unplugged or plugged with the contactor closed. The earthing switch and circuit breakers being closed with the carriage contactor plugged in. The access door to the equipment being opened when the earthing switch is open. The earthing switch handle can be locked. This prevents the carriage from being plugged back in when the earthing switch is closed. Moreover, a Ronis type of lock enables the compartment to be locked in closed position, preventing access to the interior of the compartment. Optional: An additional Ronis lock can be associated with a watch locking key, permitting access to the Example of locking function: Panel powered by two transformers Two incoming switchgear and auxiliary transformer SATA1 and SATA2 A switchgear coupling: SC Five network outgoing feeder contactors: D CELLULES CEP 14 / 15 - Sécurité Volet... CEP15 switchgear Locking Example Locking with padlock on earthing switch. 20

CEP 14 / 15 SWITCHGEARS - locking devices Example of locking function: Panel powered by a main transformer An incoming isolating switch and auxiliary transformer: SATA Locking Devices CEP15 switchgear Locking Example CEP 14 / 15 SWITCHGEARS - safety Your safety is our priority. Double safety: Access to the interior of a compartment is only possible after having: Moved the unpluggable contactor Performed the locking sequence The isolating switches and contactors are mounted on an unpluggable carriage. A mechanical fixture linked to movement of the unpluggable carriage enables the busbar to be isolated by a closed protective shutter. 21

CONTROL CABINET AND POWER SUPPLY TO LOW VOLTAGE AUXILIARIES ON THE TRANSFORMER SUBSTATION Powered by one or more of the auxiliary transformers on the substation, the low voltage cabinet provides: The power supply to electrical auxiliaries at the substation Upstream disengagement to a transformer fault Control of the lighting Basic equipment: Door features: A general multi-function switch for auto-stopmanual A programmable logic controller serving the automation functions An alarm and transformer fault indicator A voltage indicator on the 230 V auxiliary power source A fall-back p o s i t i o n v o l t a g e i n d i c a t o r on the 24 V auxiliary p o w e r source Design: Switch cabinet made of 20/10 mm steel sheet, designed for an internal installation scenario. Topcoat of light grey RAL 7035 Closed by a door equipped with a lock 4 wall-mounted fittings Dimensions 600 x 600 x 200 mm or 1000 x 800 x 300 mm depending on the equipment. Unbalanced current fault relay A 30 ma differential circuit breaker for supplying power to one or more power sockets Control of downstream disengagement in response to a transformer fault Wiring and terminal connector strips Programmable logical controller: Power supply 230 V AC or 24 V DC, Number of inputs and outputs suitable for the configuration of the substation. Programmed controller supplied to assure control of lighting, enabling alarms and faults to be viewed on the controller screen, specifically: Temperature alarm Pressure fault Temperature fault Gas disengagement fault Optional equipment: An astronomical clock A choice of 230 V automatic inversion unit Monitoring equipment for the substation. Internal features: A 300 ma differential circuit breaker for general protection Circuit breakers intended to supply power to: Normal lighting of the substation and emergency lighting The standalone 24 V or 48 V DC block The switch cabinet itself Comment: The equipment in the cabinet can change according to the equipment configuration of the substation. 22

CEP 14 / 15 SWITCHGEARS: related services Advice and documentation: Specialists are here to listen to you and to propose the best possible options from the list of equipment. The switchgears are delivered in factory-configured condition according to the replaced technical elements. Each switchgear is supplied with: Notification of commissioning of the mechanical section, enabling the switchgear to be installed Notification of commissioning of the control parts explaining the configuration and use of the graphic user interface. Connection diagram Locking diagram Electrical circuit diagram On-site commissioning support for switchgears: Augier technical staff are there to support you when you start up the equipment line-up. This commissioning process also involves: Checking the locking functions Checking the wiring options Checking protection devices and testing their function. Servicing and maintenance: We recommend arranging for servicing and maintenance of the switchgears once a year. An Augier technician can do this for you. Length of time involved in this work: One day per series of three compartments. Training: Augier is a certified training organisation. Certification N 93060176606 Training provided on-site, on the hardware and equipment used on a daily basis. 23

With a view to making continuous improvements, the manufacturer reserves the right to modify models without prior notice. AUGIER IS CERTIFIED IN ACC. WITH ISO 9001 SINCE 1995 24