Brownlee SPP. HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology

Similar documents
REACH FOR MORE CHOICES IN LC ANALYSIS. FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

More Chemistries, More Choices For Your Toughest Separation Challenges

NEW! Roc LC Columns: The Reliable Cornerstone for Your LC Lab

HiQ sil TM HPLC Columns

SIMPLIFY. QUANTIFY. The Flexar SQ 300 MS. Spare Probe Assemblies / Dielectric Capillary. Calibration Solutions. Test Kits.

Guard Columns ---- HPLC Column Catalog

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

Technical Overview. Introduction

until now. NEW ZORBAX Eclipse Plus LC Columns No LC column has ever reliably produced such symmetrical peaks for basic compounds...

ANALYTICAL NovoGROM COLUMNS 3.0, 4.0, and 4.6 mm i.d.

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Save Money. Kromasil Columns packed by Phenomenex

Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio

SEMI-PREPERATIVE- and PREPARATIVE NovoGROM HPLC-Columns to 10.0 cm i.d. -

Bio Compatibility Kit

Minisart Syringe Filters Removal of Particles and Microorganisms from Liquids and Gases

Flexible Reliable Reproducible Secure Expandable Efficient

HICHROM. Chromatography Columns and Supplies. HPLC Columns & Materials Partisil & Partisphere. Catalogue 8. Hichrom Limited

Introduction to the HPLC ChemStation and Acquisition

Agilent 1260 Infinity Diode Array Detector

Achieve FASTERLC. with Onyx Monolithic Silica HPLC Columns. Featuring: New Onyx HD Columns for Increased Efficiency!

Release Note for Agilent LC and CE drivers Revision A.02.14

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Release Note for Agilent LC and CE Drivers Revision A.02.15

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

CHROMABOND Flash cartridges

Release Note for Agilent LC and CE Drivers Revision A.02.17

Agilent Splitter Kits

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

Agilent 1290 Infinity with ISET

Agilent s Newly Expanded ZORBAX Eclipse Plus LC Column Portfolio

Spark Holland introduces

14. Chromatography Syringes/Microlitre Syringes

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

Release Note for Agilent LC and CE Drivers Revision A.02.16

SOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

Waters 600E Multisolvent Delivery System Quick Start Guide

Educational Microfluidic Starter Kit

Accessories for

Spectrum 10 Spectroscopy Software

Mini vertical unit. Combs

Equipment Overview: Safety:

S800 Spectrawave Visible Diode Array Spectrophotometer

Upchurch Scientific Nano Flow Sensor User s Guide

Flash Chromatography. Sorbtech Purity Flash Cartridges. EZ Flash Cartridges. EZ Flash Systems. Flash Chrom.

Sepacore X10 / X50 system Technical data sheet

Spark Holland introduces

Agilent Instrument Control Framework (ICF) Update A Driver Update 1 (DU1) Hot Fix 2 (HF2)

Guidebook for Installation and Familiarization. HP 1100 Series Combinatorial Chemistry Analysis System

Dissolution Testing PT DT70

Agilent 6100 Series Quad LC/MS System

Agilent SD-1 Purification Solution

Agilent 1290 Infinity 2D-LC Solution

HPLC Basics, Equipment, and Troubleshooting

True Blue Performance

User Manual. Agilent 1260 Infinity HPLC-Chip Cube Interface (G4240A )

Over. Year of Service. 2017/2018 Product Catalog. Chromatography. Research Supplies

Trends in HPLC column technology and their application

Huqun Liu, Varian Inc., Lake Forest CA

Chromatography Data System

ChromQuest 5.0 Quick Reference Guide

Cellular Imaging and Analysis

Agilent 1290 Infinity with ISET

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Penetration - Bitumen Method - PNR 12 (automatic)

Sniffer 9100 Series. GC-O GC/MS-O, State of the art... GC-Olfactometry Method for Food, Flavor and Fragrances. Principle

C190-E092A Prominence Gel Permeation Chromatography System Shimadzu High Performance Liquid Chromatograph

Agilent 1290 Infinity 2D-LC-Solution

HITACHI LACHROM ELITE

Cliquid and MPX Driver Software. Byron Kieser Director Small Molecule System Solutions

Using the Chromeleon Summit 2 Tandem Operation Wizard

PLATINblue MSQ Plus. Connection Guide V6951A UHPLC/HPLC. Mass spectrometry

Product Catalog. EasySampler EasySampler Unattended, Representative Sampling

Easidew Portable Hygrometer

Automated Fraction Re-Analysis Does it really make sense?

Customers should provide all necessary operating supplies upon request of the engineer.

Agilent InfinityLab LC Series 1290 Infinity II Preparative Column Compartment

The Perfect Fit for Over 40 Years

eprep Sample Preparation Workstation

Manual HPLC-4 Alliance-UV

Overview INTELLIGEN ULV DISPENSE SYSTEM. Advanced two-stage system enabling superior dispense and filtration of ultra-low viscosity fluids

Cecil Dissolution 4/9/06 4:51 pm Page 1 DISSOLUTION SYSTEMS

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

2 CHROMATOGRAPHY. Specifications. t Go To TOC jacketed column shown with optional flow adapter.

Singlemode SC Connector Kits Polymer Crimp Body. Housing Boot. 3.0 mm Jacketed. Simplex Blue Blue. Duplex Blue Blue

3M Purification Inc. 3M High Flow Series Filter System for Residential & Commercial Applications

DNA Shearing with E220 Focused-ultrasonicator.

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Specification. Radiamatic Detectors and Accessories

Wafer Handling Tools Vacuum Wands

columns IonSwift MAX-100 Anion-Exchange Column

ComingSoon FulNMRCatalog visitwilmad.com todownload

CHROMATOGRAPHY CHROMATOGRAPHY. A World of Expertise, in your hands

Agilent GC/MSD Instructions

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1)

Transcription:

Brownlee SPP HPLC and UHPLC Column Solutions with Superficially Porous Particle Technology

Say goodbye to the limitations of traditional columns. Break free from the constraints of your Liquid Chromatography instrument. With Brownlee Superficially Porous Particle (SPP) columns, you can achieve sharper peaks and faster separation results without changing instruments, worrying about high backpressure or compromising column longevity. With their unique particle composition, only Brownlee SPP columns offer you the freedom to push your process farther: Generate UHPLC-like separations on a standard HPLC system. Achieve ultra fast performance and efficiency on your UHPLC system. Number 3000 2500 2000 1500 1000 500 0 Brownlee SPP Particle Size Distribution Average = 2.77 microns Standard Deviation = 6% Example of a 3-micron commercial packing Average = 3.78 microns Standard Deviation = 19% -500 1 2 3 4 5 6 7 Particle Diameter, microns Compared to traditional columns, the narrow particle size distribution of Brownlee SPP columns results in sharper peak resolution. Run samples in a fraction of the time of conventional 3 µm or 5 µm particle columns. Realize significant savings through faster method development, column longevity and use of less mobile phase solvent. Easily optimize or convert any instrument, including HPLC or UHPLC systems from PerkinElmer, Agilent, and other manufacturers. SPP Particle Technology 0.5 µm 1.7 µm 2.7 µm Smaller in size and innovative in design, superficially porous particles are made by fusing a porous silica layer to a solid inner core. Innovative to the core Brownlee SPP columns generate fast separations and superior results because of their breakthrough particle design and size. Unlike other columns that use 3 µm fully porous particles, Brownlee SPP columns use 2.7 µm particles comprised of a thin outer shell of high-quality porous silica fused to a solid inner core. This advanced design allows for a shorter diffusion path, which reduces the time solute molecules spend inside the particles while passing through the stationary phase. This, in turn, keeps backpressure to a minimum and improves column efficiency. In addition, the combined particle density and narrow particle size distribution improves column durability and reduces eddy diffusion of solute molecules. It all adds up to sharper peaks, faster separation and greater resolution, time and time again. 2

Super separating power Compared to columns of the same length packed with 3 µm particles, Brownlee SPP columns deliver over 90% more separating power (plates), and almost three times the separating power of columns packed with 5 µm particles for a similar cost. Brownlee SPP columns deliver more separating power Sub-2 µm Brownlee SPP 2.2 µm 3 µm 0 50,000 5 µm 3.5 µm 100,000 150,000 200,000 250,000 N/Meter Note: N/Meter values were calculated at the optimum mobile phase linear velocity for each of these stationary phases. Efficiencies all the way At PerkinElmer, we understand the importance of time demands with your workflow. That s why our SPP columns are designed to help you achieve greater efficiencies with minor to no instrument modification. By maintaining their resolving power at high flow rates, Brownlee SPP columns allow for higher sample throughput with enhanced results. In a recent study, SPP columns separated seven compounds in less than 48 seconds with better than baseline resolution for all peak pairs. * In fact, an incremental 50% improvement in efficiency may be achieved on your traditional analytical 400 bar HPLC system with no instrument modification. And with instrument optimization, you can enjoy system performance that rivals a UHPLC system at pressures up to 9000 p.s.i. But Brownlee SPP columns don t just save valuable process time; they provide significant cost and environmental savings as well. The SPP design allows for less solvent consumption and reduced waste disposal. Plus, the columns are compatible with 2 µm inlet frits, so you can use traditional solvents and sample preparation, while enjoying the same ease-of-use of 5 µm particle columns. For UHPLC system users, there s no need to purchase specialized filters. HOW THE UNIVERSITY OF TENNESSEE SEPARATED FROM THE PACK. When the University of Tennessee Center for Renewable Carbon wanted to speed up their process, we worked with them to optimize their Flexar LC with Brownlee SPP columns. Within two hours, we reduced their run time from 60 minutes to under 10 minutes while improving resolution. The durability and longevity to go the distance The demands of high-speed applications make it difficult for most columns to perform consistently over time. Brownlee SPP columns, however, feature an advanced design that can handle the pressure. First, the particles have an extremely narrow size distribution range. Second, the particles are more consistent in size than conventional particles, allowing them to be more easily and securely packed into the column. The resulting columns are extremely rugged, reproducible and reliable so much so that tests show they can handle over a thousand injections for numerous applications. * Study based on Fast Separation of Benzoic acids. Brownlee SPP: C18, 2.7 µm x 4.6 x 50 mm. Mobile Phase: 55% Methanol, 45% 25mM sodium phosphate, ph 2.5. Flow rate: 2.2 ml/min. Temperature: ambient (24 C). Pressure: 4,700 psi, 320 bar. Sample: 1) Uracil 2) Phthalic Acid 3) Impurity 4) 2-Flourobenzoic 5) 3-Nitrobenzoic acid 6) 3-Flourobenzoic acid 7) m-toluic Acid www.perkinelmer.com/spp 3

Performance For Every Phase Brownlee SPP 2.7 µm Columns Diameter/Length Part Number Diameter/Length Part Number Diameter/Length Part Number C18 2.1 x 20 mm N9308400 2.1 x 30 mm N9308401 2.1 x 50 mm N9308402 2.1 x 75 mm N9308403 2.1 x 100 mm N9308404 2.1 x 150 mm N9308405 3.0 x 20 mm N9308406 3.0 x 30 mm N9308407 3.0 x 50 mm N9308408 3.0 x 75 mm N9308409 3.0 x 100 mm N9308410 3.0 x 150 mm N9308411 4.6 x 20 mm N9308412 4.6 x 30 mm N9308413 4.6 x 50 mm N9308414 4.6 x 75 mm N9308415 4.6 x 100 mm N9308416 4.6 X 150 mm N9308417 C8 2.1 x 20 mm N9308418 2.1 x 30 mm N9308419 2.1 x 50 mm N9308420 2.1 x 75 mm N9308421 2.1 x 100 mm N9308422 2.1 x 150 mm N9308423 3.0 x 30 mm N9308424 3.0 x 50 mm N9308425 3.0 x 75 mm N9308426 3.0 x 100 mm N9308427 3.0 x 150 mm N9308428 4.6 x 20 mm N9308429 4.6 x 30 mm N9308430 4.6 x 50 mm N9308431 4.6 x 75 mm N9308432 4.6 x 100 mm N9308433 4.6 x 150 mm N9308434 HILIC 2.1 x 30 mm N9308435 2.1 x 50 mm N9308436 2.1 x 75 mm N9308437 2.1 x 100 mm N9308438 2.1 x 150 mm N9308439 3.0 x 30 mm N9308440 3.0 x 50 mm N9308441 3.0 x 75 mm N9308442 3.0 x 100 mm N9308443 3.0 x 150 mm N9308444 4.6 x 30 mm N9308445 4.6 x 50 mm N9308446 4.6 x 75 mm N9308447 4.6 x 100 mm N9308448 4.6 x 150 mm N9308449 Peptide ES-C18 2.1 x 30 mm N9308450 2.1 x 50 mm N9308451 2.1 x 75 mm N9308452 2.1 x 100 mm N9308453 2.1 x 150 mm N9308454 3.0 x 30 mm N9308455 3.0 x 50 mm N9308456 3.0 x 75 mm N9308457 3.0 x 100 mm N9308458 3.0 x 150 mm N9308459 4.6 x 30 mm N9308460 4.6 x 50 mm N9308461 4.6 x 75 mm N9308462 4.6 x 100 mm N9308463 4.6 x 150 mm N9308464 PFP 2.1 x 20 mm N9308465 2.1 x 30 mm N9308466 2.1 x 50 mm N9308467 2.1 x 75 mm N9308468 2.1 x 100 mm N9308469 2.1 x 150 mm N9308470 3.0 x 30 mm N9308471 3.0 x 50 mm N9308472 3.0 x 75 mm N9308473 3.0 x 100 mm N9308474 3.0 x 150 mm N9308475 4.6 x 30 mm N9308476 4.6 x 50 mm N9308477 4.6 x 75 mm N9308478 4.6 x 100 mm N9308479 4.6 x 150 mm N9308480 Phenyl-Hexyl 2.1 x 20 mm N9308481 2.1 x 30 mm N9308482 2.1 x 50 mm N9308483 2.1 x 75 mm N9308484 2.1 x 100 mm N9308485 2.1 x 150 mm N9308486 3.0 x 30 mm N9308487 3.0 x 50 mm N9308488 3.0 x 75 mm N9308489 3.0 x 100 mm N9308490 3.0 x 150 mm N9308491 4.6 x 30 mm N9308492 4.6 x 50 mm N9308493 4.6 x 75 mm N9308494 4.6 x 100 mm N9308495 4.6 x 150 mm N9308496 4

Diameter/Length Part Number Diameter/Length Part Number Diameter/Length Part Number RP-Amide 2.1 x 20 mm N9308497 2.1 x 30 mm N9308498 2.1 x 50 mm N9308499 2.1 x 75 mm N9308500 2.1 x 100 mm N9308501 2.1 x 150 mm N9308502 3.0 x 30 mm N9308503 3.0 x 50 mm N9308504 3.0 x 75 mm N9308505 3.0 x 100 mm N9308506 3.0 x 150 mm N9308507 4.6 x 30 mm N9308508 4.6 x 50 mm N9308509 4.6 x 75 mm N9308510 4.6 x 100 mm N9308511 4.6 x 150 mm N9308512 C18 Guard Column Packs 2.1 x 5 mm, 3 pk N9308513 3.0 x 5 mm, 3 pk N9308514 4.6 x 5 mm, 3 pk N9308515 C8 Guard Column Packs 2.1 x 5 mm, 3 pk N9308522 3.0 x 5 mm, 3 pk N9308523 4.6 x 5 mm, 3 pk N9308524 HILIC Guard Column Packs 2.1 x 5 mm, 3 pk N9308525 3.0 x 5 mm, 3 pk N9308526 4.6 x 5 mm, 3 pk N9308527 Peptide ES-C18 Guard Column Packs 2.1 x 5 mm, 3 pk N9308528 3.0 x 5 mm, 3 pk N9308529 4.6 x 5 mm, 3 pk N9308530 PFP Guard Column Packs 2.1 x 5 mm, 3 pk N9308531 3.0 x 5 mm, 3 pk N9308532 4.6 x 5 mm, 3 pk N9308533 Phenyl-Hexyl Guard Column Packs 2.1 x 5 mm, 3 pk N9308519 3.0 x 5 mm, 3 pk N9308520 4.6 x 5 mm, 3 pk N9308521 RP-Amide Guard Column Packs 2.1 x 5 mm, 3 pk N9308516 3.0 x 5 mm, 3 pk N9308517 4.6 x 5 mm, 3 pk N9308518 Guard Column Holder N9308534 Brownlee SPP Phases And Applications UHPLC Phases * Pore Size (Å) Coverage (µmol/m^2) ph Range Temp Limit ( C) C18 90 3.5 2 to 9 60 C8 90 3.7 2 to 9 60 HILIC 90 N/A 2 to 8 60 Peptide ES-C18 160 2.0 1 to 8 90 PFP (pentafluorophenylpropyl) 90 3.6 2 to 8 60 PhenylHexyl 90 3.0 2 to 9 60 RP-Amide 90 3.0 2 to 9 60 Applications General Purpose Octadecyl phase for reversed phase separations. General Purpose Octyl phase for reversed phase separations when less retention than a C18 is desired. General purpose bare silica column for normal phase and HILIC applications. Sterically protected ligand (isobutyl - side chains), results in an Extra Stable bonded phase at low ph where most peptide separations are performed. Highly retentive and selective for protonated basic analytes and molecules containing aromatic moities. Alternative selectivity to alkyl bonded phases, recommended for aromatic groups. Compatible with highly aqueous mobile phases to facilitate the retention and separation of polar compounds. Excellent phase for significantly increasing the retention and selectivity of acids, for symmetrical peak shapes of bases, zwitterions and other polar compounds. Chromatographic Properties A high-purity column that exhibits excellent peak shape for a wide range of compounds. High purity reversed phase packing that exhibits excellent peak shape for a wide range of compounds. High purity silica substrate. The 160 Angstrom pore size was specially chosen for the molecular weight range of peptides. The ligand was chosen due to its sterically protected bonding technology that inhibits acid hydrolysis of the siloxane bonds, even under extremes of high temperature and low ph. End-capped pentafluorophenyl with a propyl spacer. Base-deactivated for good peak shapes when separating basic compounds. Hexyl spacer provides optimal flexibility for phenyl ring to facilitate π-π interactions with solutes. Base-deactivated phase with a polar group within the alkyl bonded phase. Provides unique selectivity and a high level of base deactivation while reducing or eliminating the need for mobile phase additives. * Maximum pressure 9,000 p.s.i. for all columns. ** All particle sizes are 2.7 µm. Not end-capped. All others end-capped. www.perkinelmer.com/spp 5

Brownlee SPP columns can be used to enhance the performance of virtually any HPLC or UHPLC system. Our OneSource Service Engineers are certified on all leading manufacturer instruments and can help optimize your instrument's performance with minor modifications combined with our Brownlee SPP columns. PerkinElmer Flexar/Series 200 Analytical System Optimization Kits for Ultimate Performance For both Flexar UHPLC and Series 200 conventional LC systems (non-uhplc), we have created and tested two optimization kits for SPP column applications: one for UV/Vis systems (N2920191) and one for PDA systems (N2920193). With Brownlee SPP optimization kits, which contain smaller diameter tubing and a 2.4 ul flow cell, users can significantly minimize band broadening for enhanced operation on conventional LC systems. N2920191 for Series 200 LC or Flexar UHPLC systems with UV/Vis detector Description Quantity Part Number Ferrule 1/16 inch 2 00873032 Tubing.005 ID 316 Stainless Steel (SS (50 cm) 1 02507060 Fingertight 1-piece Nut and Ferrule 1 09920513 Nut 10-32 CPI Stainless Steel Gland for 1/16 inch Tubing 2 N2916202 Tubing 30 inch.004 ID 1/16 OD Peek (black) 1 N2916260 Flowcell Assembly for UV/Vis 6 MM 2.4 ul 1 N2920127 N2920193 for Series 200 LC or Flexar UHPLC systems with PDA detector Description Quantity Part Number Ferrule 1/16 inch 2 00873032 Tubing.005 ID 316 Stainless Steel (50 cm) 1 02507060 Fingertight 1-piece Nut and Ferrule 1 09920513 Nut 10-32 CPI Stainless Steel Gland for 1/16 inch Tubing 2 N2916202 Tubing 30 inch.004 ID 1/16 OD Peek (black) 1 N2916260 Flowcell Assembly for PDA 6 MM 2.4 ul 1 N2920128 6

Agilent Optimization Kits Brownlee SPP columns offer Agilent 1100 users the opportunity to obtain enhanced performance from their existing HPLC instrument. Our SPP columns deliver resolution and speed similar to sub-2 µm UHPLC columns, but generate only 40% to 50% of the backpressure. By combining high efficiency and lower backpressure, Brownlee SPP columns make it possible to get UHPLC-like performance from conventional 400-bar equipment, such as the Agilent 1100. PerkinElmer has created and tested eight optimization kits for your Agilent systems. Description Part Number Description Part Number Extra column volume (ECV) - STD Autosampler and Variable Wavelength Detector (VWD) Optimization Kit Needle Seat Capillary, 0.12 mm ID capillary, 1.2 µl Semi-Micro Cell Assembly Seat Capillary 0.12 x 100 mm, 0.8 mm OD Carrier for Heat Exchanger Thermostatted Column Compartments (TCC) SL ECV - STD Well Plate Autosampler and Diode Array Detector / Multiple Wavelength Detector (DAD/MWD) 1100 DAD Cell Assembly, 6 mm, 5 ul, 120 bar Seat Capillary 0.12 x 100 mm, 0.8 mm OD SS Capillary 0.12 x 100 mm, 0.8 mm OD ZECVSTDVWD ZECVSTDWPDADMWD ECV - STD Autosampler and DAD/MWD ZECVSTDDADMWD Needle Seat Capillary, 0.12 mm ID capillary, 1.2 µl 1100 DAD Cell Assembly, 6 mm, 5 ul, 120 bar Seat Capillary 0.12 x 100 mm, 0.8 mm OD ECV - STD Well Plate Autosampler and VWD ZECVSTDWPVWD Semi-Micro Cell Assembly Seat Capillary 0.12 x 100 mm, 0.8 mm OD SS Capillary 0.12 x 100 mm, 0.8 mm OD Ultra Low ECV - STD Autosampler and VWD Needle Seat Capillary, 0.12 mm ID capillary, 1.2 µl Micro Flow Cell, 5 mm, 1 ul, 40 bar High Temperature Heat Exchanger, 1.6 µl, 0.12 mm ID Ultra Low ECV - STD Well Plate Autosampler and DAD/MWD Micro Flow Cell 2 ul, 3 mm path High Temperature Heat Exchanger, 1.6 µl, 0.12 mm ID SS Capillary 0.12 x 100 mm, 0.8 mm OD ZULECVSTDVWD ZULECVSTDWPDADMWD Ultra Low ECV - STD Autosampler and DAD/MWD ZULECVSTDDADMWD Needle Seat Capillary, 0.12 mm ID capillary, 1.2 µl Micro Flow Cell 2 ul, 3 mm path High Temperature Heat Exchanger, 1.6 µl, 0.12 mm ID Ultra Low ECV - STD Well Plate Autosampler and VWD ZULECVSTDWPVWD Micro Flow Cell, 5 mm, 1 ul, 40 bar High Temperature Heat Exchanger, 1.6 µl, 0.12 mm ID SS Capillary 0.12 x 100 mm, 0.8 mm OD www.perkinelmer.com/spp 7

Whether you need help choosing the right SPP columns for your LC instrument, assistance with installation, or restocking your inventory, PerkinElmer is ready to assist you with trained customer service representatives and experienced field service engineers. But we don t stop there. Brownlee SPP columns are just one of the many analytical solutions we offer to power your process. We boast an industry-leading portfolio that encompasses instruments, accessories, consumables, supplies, training and service. It s a breadth of capabilities that enables you to have a single supplier for all your laboratory needs at every stage of your workflow. So you can benefit from greater responsiveness, superior reliability and dramatic cost savings. Our OneSource Laboratory Services division even takes it a step further. With more than 1,500 trained and certified field service engineers and service personnel around the world, OneSource offers the most comprehensive range of professional laboratory services in the industry, including complete care programs for virtually every technology and manufacturer. So turn to PerkinElmer. For the experience. For the confidence. For the better. Couple SPP With Leading Instrumentation For Ultimate Laboratory Efficiency Series 200 HPLC Flexar HPLC and UHPLC PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2011, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009796_01 Printed in USA