RT2Y Compact temperature switch intrinsic safety

Similar documents
RT2E Compact temperature switch Explosion proof

Gas-actuated thermometer Stainless steel version Model 73

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Series Panel Mounted Control Devices

Series 3730 Electropneumatic Positioner Type

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Variable Area Flowmeter DATASHEET

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

DR7100 SERIES Supplementary instructions

Instruction Manual. T3110 T3110L T3110Ex

Material pressure (bar) (Cv (US) kv x 1,2 Seat

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Series 3730 Type Electropneumatic Positioner

Threaded resistance thermometer Miniature design Model TR10-D

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

SideControl Positioner

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

Float Switches with Permanent Magnet For Vertical Installation Model RSM

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

21D Allfluid pressure switch, electromechanically actuated

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Inductive sensor NI3-EG08K-Y1-H1341

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Inductive sensor BI1.5-EG08-Y1-H1341

Contact Dial Thermometers

Capacitance level switches LS 210 LS 220

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

SMARTLINE RM76 Supplementary instructions

PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Linear Luminaire with LED Series 6412/5

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Inductive sensor BI1.5-EG08-Y1-H1341

Installation & Operation Manual

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

Safety instructions Overvoltage protection B81-35

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Operating Instructions

5 Fieldbus Technology

Resistance thermometer With spring-loaded tip Model TR55

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Linear Luminaire with LED Series 6012/5

LS 6600 Technical Datasheet

Technical Data. General specifications. Rated operating distance s n 3 mm

Grounding Monitoring Device Series 8485

KOBOLD PDA Series Digital Pressure Transmitter

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Installation & Operation Manual

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

KOBOLD TDA Series Digital Temperature Transmitter

PHOENIX CONTACT - 01/2008

DTB-1. Digital Thermometer Battery Powered

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Technical Information Promonitor NRF560

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Inductive sensor with analog output BI15-M30-LI-EXI

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

HERION SERIES Indirect solenoid actuated spool valves

PROFIBUS-PA Positioner Type 3785

Grounding Monitoring Device Series 8485

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Conveyor Belt Alignment Switches from IDEM

Safety switches with separate actuator

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Bimetal spiral. Graduation: Scale angle Over-temperatures (occasionally allowed) Pointer. Dial. Accuracy (according to EN 13190) Class 1

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Flow. Flow. N/en

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Product Summary. Display instrumentation for use in hazardous and safe areas. visit our website Loop Powered Indicators.

red-y industrial series Thermal Mass Flow Meters and Controllers for Gases

Pressure switch, Differential pressure switch RT

Digital electropneumatic positioner

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Dial Thermometer. Particularities. Brief description. Technical data. Page 1/6. Data Sheet

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

General Specifications

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Standard enclosure for Remote I/O Series 8150

ExCos-P Pressure sensor 20 Pa Pa

Inductive sensor BI5-EM18-Y1X-H1141

Transcription:

ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications Power generation safety equipment Water treatment Valve and compressor control Technical Data Temperature range -46... 0 to 160... 250 Temperature Process : -46... +250 mbient : -30... +70 (T5) -30... +55 (T6) Storage : -40... +70 Repeatability E conformity Protection rating IP 66 (EN 60529) Process connection Bulb Scale Weight Body Housing Mounting Ground connection ± 1% F.S. / constant temperature cycle Low Voltage Directive LVD 2006/95/E TEX Directive 94/9/E Stainless steel 1.4404 (316L) Stainless steel 1.4404 (316L) Ø 9.5 mm Internal graduated scale 0.960 kg + transmission Zamak black painting Plastic P6, blue Wall mounting 2 x M5 screws Via internal terminal block Electrical Via internal terminal block with cable gland for connection Ø 5.5 to 8.5 mm Electrical function See ordering code details in page 5 djustment Internal adjustment possible for set point TEX Type examination certificate LIE 03 TEX 6160X EN 60079-0: 2012 (internal conformity analysis) EN 60079-11: 2012 Marking 0081 I M 1 Ex ia I Ma II 1 G Ex ia II T6 or T5 Ga Electrical data U max = 30 Vdc I max = 66 m P max = 0.5 W i = Negligible ; L i = Negligible Options ustomer specific set point adjustment ode SETP Mounting on 2" pipe ode 0407 Stainless steel tag plate and wire ode 9941 Lead seal of the housing ode 8990 Page 1 / 5

ompact temperature switch intrinsic safety Principle vapour filled flexible sensing element actuates a microswitch by means of a piston. The set point is adjusted by means of a compressible spring installed in opposition. N N N T P Set point and reset point must be between 10% and 90% of the selected scale. Standard factory adjustment Setpoint at 50% of the scale on falling temperature ustomer specific factory adjustment (option SETP) The following specifications have to be given with the order: Setpoint value djustment on falling or raising temperature N N N djustable ranges Micro-switch dead band 1) Scale T max ode Fixed dead band M 10% 90% -46... 0 40 40 5 4-20... 20 60 41 5 4 0... 45 80 42 3.5 3 40... 120 145 43 6 6 100... 180 190 44 7 5.5 20... 90 120 45 11 11 160... 250 290 46 6.5 5 70... 150 175 48 11 8 1) The value of the dead band is depending on the value of the set point. This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For other set points the dead band value can be calculated by linear interpolation between the values at 10% and 90%. Page 2 / 5

ompact temperature switch intrinsic safety Micro switches characteristics Switch code M Gold contact 6 Vdc 10... 50 m 12 Vdc 10... 50 m 24 Vdc 10... 50 m 30 Vdc 10... 50 m 48 Vdc N/ 110 Vdc N/ 220 Vdc N/ 115 Vac N/ 250 Vac N/ Dielectric rigidity between contacts and ground 2000 V Electrical connections Micro switch N Blue Terminal block Hazardous area Zone 0, 1, 2 ertified safety barrier Non hazardous area OM Red White Yellow / green N or N Rc 1 + Supply Screen For max. ambient temperature according to temperature classes T5 and T6 refer to technical data on page 1. The installation must be made in an intrinsically safe circuit whose certified electrical safety parameters do not exceed any of the values U max, I max and P max given in the electrical data on page 1. ll necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's temperature to such that it reaches the self-ignition temperature of the gas in which it is used. Page 3 / 5

ompact temperature switch intrinsic safety Dimensions (mm) Direct mount temperature switches 97 2 grooves 5,5 27/ 2 plats flats 68 E Ø 8 Temperature switches with capillary 73,5 98 33 33 K ±2% K ±2% S = Bulb length (temperature sensitive part) = dditional stem length (min. 25 mm) P = Immersion length (P = S + ) K = apillary length (only TD1, TD2, TD3) E = Extension between process connection and housing only TRDE1 and TRDE2 For version TD1 there is no additional stem length ( = 0). The sliding connection is mounted on the capillary. P ± 3 Ø 9,5 100 S Ø 2,6 Ø 8 Ø 8 P ± 3 TRDE 1/2 S Ø 9,5 S TD1 TD2 TD3 Stainless steel sliding male connection (TD2/3, TRDE1/2) Stainless steel sliding male connection (TD1) Thread and sizes Thread and sizes lamping nut Process connection lamping ring F B H L F G 1/2 1/2 NPT H 18 21 L 36 40 17/flat 17/flat B 23/flat 23/flat lamping nut Tightness fittings Process connection B H L F G 1/2 1/2 NPT H 18 21 L 43 46 27/flat 27/flat B 27/flat 27/flat fter tightening of the clamping nut, the stem is fixed in the process connection. Tight up to 40 bar. F Waterproof after tightening mounted on the capillary. Bulb length (S) according to the capillary length (K) and the temperature range (code) apillary ode 40 41 42 43 44 45 46 48 TRDE1 n/a S / mm 100 100 100 100 n/a 100 n/a n/a TRDE2 n/a S / mm 100 100 100 100 100 100 100 100 TD1, TD2, TD3 K = 1...4 m S / mm 100 100 100 100 100 100 100 100 TD1, TD2, TD3 K = 5...7 m S / mm 100 150 150 100 100 150 100 100 TD1, TD2, TD3 K = 8...10 m S / mm 100 200 200 100 100 200 100 100 Versions with S = 150 mm or S = 200 mm are not feasible with P = 150 mm Page 4 / 5

ompact temperature switch intrinsic safety Ordering details RT2Y RT2.. / Model ompact temperature switch RT2 pprovals TEX intrinsic safety Y Type of microswitch 1 SPDT gold contact change over switch M. Temperature range ( ) -46... 0 40-20... 20 41 0... 45 42 40... 120 43 100... 180 (not for TRDE1) 44 20... 90 45 160... 250 (not for TRDE1) 46 70... 150 (not for TRDE1) 48. Type of transmission TD1 Stainless steel capillary without protection 1 TD2 Stainless steel capillary with stainless steel protection 2 TD3 Stainless steel capillary with stainless steel protection and PV coating 3 TRDE1 Rigid transmission with E=65 mm for temperature measurement below 120 TRDE2 Rigid transmission with E=120 mm for all temperature measurement D apillary length (K) Direct mounting (for TRDE1 and TRDE2) 0 1 meter 1 2 meters 2 3 meters 3 4 meters 4 5 meters 5 6 meters 6 7 meters 7 8 meters 8 9 meters 9 10 meters Immersion length (P) Immersion length (P) = Bulb length (S) + additional stem length () P = S + 25 mm (minimum additional stem length = 25 mm, for S see table on page 4) 0 P = 150 mm (not for TD1) 3 P = 250 mm (not for TD1) 4 P = 400 mm (not for TD1) 5 P = 600 mm (not for TD1) 6 P = 1000 mm (not for TD1) D Bulb diameter Ø 9.5 mm Process connection Without 0 G1/2 male (standard) 3 1/2 NPT male 6 Options to be added behind the / (see example below) / Ordering example with options ompact temperature switch TEX intrinsic safety 1 SPDT gold contact change over switch Temperature range -46... 0 Transmission TD2 apillary 1 meter Immersion length 150 mm Bulb Ø 9.5 mm Process connection G1/2 Option: Stainless steel tag plate and wire RT2 Y M. 40. 2 1 3 3 / 9941 Page 5 / 5