IntelliBridge EC10 & EC5 Philips 865115 & 865114 External Devices Configuration Guide A.01.01 Printed in Germany 05/2011 IntelliBridge EC10/EC5 components Each IntelliBridge consists of three components. The IntelliBridge EC10 Module with the drivers The IntelliBridge EC5 ID-Module, which connects to and identifies the specific external device. The connection cable (available in a selection of lengths) Using this Guide This guide describes how to specify an IntelliBridge EC10/EC5 solution for your customer. 1. Go to the table corresponding to the revision of the IntelliVue patient monitor into which the module is to be inserted. 2. Find the row for the external device to which your customer wants to connect. These modules are grouped together. Only a certain number of modules from one group can be used simultaneously by the model of the IntelliVue patient monitor. 3. If the customer wants to use more than one module. in the column corresponding to their model of IntelliVue patient monitor, make sure they do not exceed the number of modules from this group the monitor can support simultaneously. 4. If the customer wants to use more than one module, refer to the last line of the table. In the column corresponding to their model of IntelliVue patient monitor, make sure they do not exceed the maximum number of modules
supported by the model of IntelliVue patient monitor. For further discussion with the customer, and for correct ordering, you will need to know the device driver designation, and the option numbers: 5. From the row for the external device, make a note of The device driver for the the IntelliBridge EC10 Module (for use with the part number 865115) The option number for the IntelliBridge EC5 ID-Module (for use with the part number 865114). 6. Check with the customer what length of connection cable they need. Use this to choose the correct option number for the IntelliBridge EC5 ID-Module (for use with the part number 865114). #L01 Connection Cable 1.5 m #L02 Connection Cable 3 m #L03 Connection Cable 10 m Example 1 A customer has an MP90, Rev G, wants to use their patient monitor with a Dräger Apollo anaesthesia workstation, a BBraun Space infusion pump system, and an existing VueLink module. From the table for Rev. G (See IntelliVue patient monitor Rev. G on page 3.), in the column for MP60 - MP90, you will find 1 IntelliBridge EC10 module with a Dräger Apollo driver can be used So this is not a problem. 1 IntelliBridge EC10 module with a BBraun Space System driver can be used So this is not a problem. Up to 4 VueLink modules can be used at any time From the bottom line, the MP90 supports up to 4 modules. Therefore, all three modules can be used simultaneously. Indeed, a second VueLink module could also be used if necessary. Example 2 A customer has an MP40, Rev H, wants to use their patient monitor with a Dräger Apollo anaesthesia workstation, an Edwards Vigilance hemodynamic monitor, and an existing VueLink module. From the table for Rev. H (See IntelliVue patient monitor Rev. H on page 4.), in the column for MP40 - MP50, you will find 1 IntelliBridge EC10 module with a Dräger Apollo driver can be used at any time 1 IntelliBridge EC10 module with a Edwards Vigilance driver can be used at any time Up to 2 VueLink modules can be used at any time However, from the bottom line, the MP40 only supports up to 2 modules. Therefore, any two of the three modules can be used in the monitor. Driver Availability - Software and Instructions for Use The Instructions for Use for all drivers are available in the following languages: Czech, Danish, Dutch, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Norwegian, Polish, Portuguese, Romanian, Russian, Simplified Chinese (China), Slovak, Spanish, Swedish, Traditional Chinese (Taiwan), Turkish. The driver software may not be available in all of these languages. 1. Please refer to InCenter, at https://incenter.medical.philips.com. You have to login to InCenter. Follow the instructions if you have no login. If you want to access the Instructions for Use a. Move your cursor over the heading Service, then select Products & Solutions, and then Patient Monitoring from the list. b. In the list, scroll down to the heading Bedside Monitors and then in the opening list scroll to Modules / Clinical Measurements, then again an opening list. Scroll to 865114 IntelliBridge EC5 ID-Module and click on it. You now see a list of the available user and service materials, and in which languages they are available. If you want to access the firmware and drivers a. Move your cursor over the heading Service, then select Software, and then Software downloads > Patient Monitoring from the list. b. In the list, scroll down to the heading Bedside Monitors and then in the opening list scroll to Modules / Clinical Measurements, then again an opening list. Scroll to 865115 IntelliBridge EC10 and click on it. You now see a list of the available folders, from which you can download the drivers or firmware. Please also check your local regulatory and business requirements for permission to sell. 2
IntelliVue patient monitor Rev. G Rev. G.01 or higher is needed External device drivers External Device Maximum configurable Numerics Waves Pumps Device Driver EC5 Option Number EC10 firmware revision a MP40 - MP50 MP60 - MP90 b Number of IntelliBridge EC10 modules supported Anesthesia Demo c 12 4 - IB-ED400-A.0 #400 0844 Draeger Apollo 12 3 - IB-ED402-A.0 #402 0844 Draeger Babylog VN500 12 4 - IB-ED213-A.1 #213 1020 Draeger Evita 4 12 3 - IB-ED203-A.0 #203 0844 Draeger Evita V500 12 4 - IB-ED206-A.1 #206 1020 Draeger Evita XL 12 3 - IB-ED202-A.0 #202 0844 Draeger Pallas 12 3 - IB-ED403-A.0 #403 0844 Draeger Primus 12 3 - IB-ED401-A.0 #401 0844 Edwards Vigilance 12 0 - IB-ED701-A.0 #701 0844 Edwards Vigilance II 12 0 - IB-ED702-A.0 #702 0844 Edwards Vigileo 10 0 - IB-ED703-A.0 #703 0844 GE Engström 12 4 - IB-ED217-A.0 #217 1020 Maquet FLOW-i 12 4 - IB-ED411-A.0 #411 0844 Maquet SERVO-i 12 4 - IB-ED209-A.0 #209 0844 Maquet SERVO-s 12 3 - IB-ED210-A.0 #210 0844 Puritan Bennett 840 c 12 0 - IB-ED201-A.0 #201 0844 Ventilator Demo c 12 4 - IB-ED200-A.0 #200 0844 from this group from this group BBraun Space System - - 12 IB-ED501-B.0 #501 1020 External device connected up to 6 d up to - n/a using VueLink 2 d up to 2 up to 4 Maximum number of supported modules (from all groups combined) 2 4 a Minimum required firmware revision b The MP60/MP70 has two integrated slots for plug-in modules. You can use the integrated slots for 1x IntelliBridge EC10 module 1x Vuelink module, or 1x IntelliBridge EC10 module and 1x Vuelink module. c Works with software revision G.00 and later. d Depends on what the external device provides and what the VueLink driver supports. Recommendation The newest EC10 firmware revision is backward compatible with all drivers. It is strongly recommended to always use the latest EC10 firmware revision. 3
IntelliVue patient monitor Rev. H External device drivers External Device Maximum configurable Numerics Waves Pumps Device Driver EC5 Option Number EC10 firmware revision a MP60 - MP90 b, MP40 - MP50 MX series Number of IntelliBridge modules supported Open Interface up to 6 c up to 8 c up to 2 c 0 - IB-ED101-A.0 #101 #102 #103 #104 #105 #106 1020 up to 2 up to 4 Anesthesia Demo 12 4 - IB-ED400-A.0 #400 0844 Draeger Apollo 12 3 - IB-ED402-A.0 #402 0844 Draeger Babylog VN500 12 4 - IB-ED213-A.1 #213 1020 Draeger Evita 4 12 3 - IB-ED203-A.0 #203 0844 Draeger Evita V500 12 4 - IB-ED206-A.1 #206 1020 Draeger Evita XL 12 3 - IB-ED202-A.0 #202 0844 Draeger Pallas 12 3 - IB-ED403-A.0 #403 0844 Draeger Primus 12 3 - IB-ED401-A.0 #401 0844 GE Engström 12 4 - IB-ED217-A.0 #217 1020 Maquet FLOW-i 12 4 - IB-ED411-A.0 #411 0844 Maquet SERVO-i 12 4 - IB-ED209-A.0 #209 0844 Maquet SERVO-s 12 3 - IB-ED210-A.0 #210 0844 Puritan Bennett 840 12 0 - IB-ED201-A.0 #201 0844 Ventilator Demo 12 4 - IB-ED200-A.0 #200 0844 from this group from this group BBraun Space System d - - 12 IB-ED501-B.0 #501 1020 Edwards Vigilance 8 0 - IB-ED701-A.0 #701 0844 Edwards Vigilance II 8 0 - IB-ED702-A.0 #702 0844 from this Edwards Vigileo 8 0 - IB-ED703-A.0 #703 0844 group from this group IntelliVue TcG10 2 0 - IB-ED301-A.0 #301 1020 External device connected up to 6 c up to 2 c - n/a using VueLink up to 2 up to 4 Maximum number of supported modules (from all groups combined) 2 4 a Minimum required firmware revision b The MP60/MP70 has two integrated slots for plug-in modules. You can use the integrated slots for 1x IntelliBridge EC10 module 1x Vuelink module, or 1x IntelliBridge EC10 module and 1x Vuelink module. c Depends on what the external device provides and what the device driver for the device using the IntelliBridge Open Interface or the VueLink driver supports. d Works with software revision H.15 and later. 4
Recommendation The newest EC10 firmware revision is backward compatible with all drivers. It is strongly recommended to always use the latest EC10 firmware revision. 5
Philips Healthcare is part of Royal Philips Electronics How to reach us www.philips.com/healthcare healthcare@philips.com fax: +31 40 27 64 887 0366 IntelliBridge EC10/EC5 complies with the requirements of the Council Directive 93/ 42/EEC of 14 June 1993 (Medical Device Directive). Asia +852 2821 5888 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 North America +1 425 487 7000 800 285 5585 (toll free, US only) Please visit www.philips.com/ 2011 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in The Netherlands. 4535 642 63451 May 2011